Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Br J Haematol ; 178(2): 220-230, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28573706

RESUMEN

This study aims to guide the integration of serum free light chain (sFLC) tests into clinical practice, including a new rapid test (Seralite® ). Blood and urine analysis from 5573 newly diagnosed myeloma patients identified 576 light chain only (LCO) and 60 non-secretory (NS) cases. Serum was tested by Freelite® and Seralite® at diagnosis, maximum response and relapse. 20% of LCO patients had urine FLC levels below that recommended for measuring response but >97% of these had adequate sFLC levels (oligosecretory). The recommended Freelite® sFLC ≥100 mg/l for measuring response was confirmed and the equivalent Seralite® FLC difference (dFLC) >20 mg/l identified. By both methods, ≥38% of NS patients had measurable disease (oligosecretory). Higher sFLC levels were observed on Freelite® at all time points. However, good clinical concordance was observed at diagnosis and in response to therapy. Achieving at least a very good partial response according to either sFLC method was associated with better patient survival. Relapse was identified using a Freelite® sFLC increase >200 mg/l and found 100% concordance with a corresponding Seralite® dFLC increase >30 mg/l. Both Freelite® and Seralite® sensitively diagnose and monitor LCO/oligosecretory myeloma. Rapid testing by Seralite® could fast-track FLC screening and monitoring. Response by sFLC assessment was prognostic for survival and demonstrates the clinical value of routine sFLC testing.


Asunto(s)
Mieloma Múltiple/diagnóstico , Cuidados Posteriores , Supervivencia sin Enfermedad , Humanos , Inmunoensayo/métodos , Cadenas Ligeras de Inmunoglobulina/metabolismo , Inmunoglobulinas/metabolismo , Mieloma Múltiple/inmunología , Mieloma Múltiple/mortalidad , Recurrencia Local de Neoplasia/diagnóstico , Recurrencia Local de Neoplasia/inmunología , Recurrencia Local de Neoplasia/mortalidad , Sistemas de Atención de Punto , Estudios Retrospectivos , Sensibilidad y Especificidad
2.
Clin Chem Lab Med ; 55(3): 424-434, 2017 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-27505089

RESUMEN

BACKGROUND: Serum free light chains (FLC) are sensitive biomarkers used for the diagnosis and management of plasma cell dyscrasias, such as multiple myeloma (MM), and are central to clinical screening algorithms and therapy response criteria. We have developed a portable, near-patient, lateral-flow test (Seralite®) that quantitates serum FLC in 10 min, and is designed to eliminate sample processing delays and accelerate decision-making in the clinic. METHODS: Assay interference, imprecision, lot-to-lot variability, linearity, and the utility of a competitive-inhibition design for the elimination of antigen-excess ('hook effect') were assessed. Reference ranges were calculated from 91 healthy donor sera. Preliminary clinical validation was conducted by retrospective analysis of sera from 329 patients. Quantitative and diagnostic results were compared to Freelite®. RESULTS: Seralite® gave a broad competitive-inhibition calibration curve from below 2.5 mg/L to above 200 mg/L, provided good assay linearity (between 1.6 and 208.7 mg/L for κ FLC and between 3.5 and 249.7 mg/L for λ FLC) and sensitivity (1.4 mg/L for κ FLC and 1.7 mg/L for λ FLC), and eliminated anomalous results from antigen-excess. Seralite® gave good diagnostic concordance with Freelite® (Roche Hitachi Cobas C501) identifying an abnormal FLC ratio and FLC difference in 209 patients with newly diagnosed MM and differentiating these patients from normal healthy donors with polyclonal FLC. CONCLUSIONS: Seralite® sensitively quantitates FLC and rapidly identifies clinical conditions where FLC are abnormal, including MM.


Asunto(s)
Biomarcadores de Tumor/sangre , Inmunoensayo/métodos , Cadenas kappa de Inmunoglobulina/sangre , Cadenas lambda de Inmunoglobulina/sangre , Mieloma Múltiple/sangre , Humanos , Cadenas Ligeras de Inmunoglobulina/sangre , Límite de Detección , Estándares de Referencia , Reproducibilidad de los Resultados
3.
BMC Nephrol ; 18(1): 247, 2017 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-28728609

RESUMEN

BACKGROUND: Acute kidney injury (AKI) is common in patients with multiple myeloma (MM). Whether serum free light chain (sFLC) measurements can distinguish between myeloma and other causes of AKI requires confirmation to guide early treatment. A rapid and portable sFLC test (Seralite®) is newly available and could reduce delays in obtaining sFLC results and accelerate diagnosis in patients with unexplained AKI. This study evaluated the accuracy of Seralite® to identify MM as the cause of AKI. METHOD: sFLCs were retrospectively analysed in patients with AKI stage 3 as per KDIGO criteria (i.e. serum creatinine ≥354 µmol/L or those on dialysis treatment) (n = 99); 45/99 patients had a confirmed MM diagnosis. RESULTS: The Seralite® κ:λ FLC ratio accurately diagnosed all MM patients in the presence of AKI: a range of 0.14-2.02 returned 100% sensitivity and specificity for identifying all non-myeloma related AKI patients. The sFLC difference (dFLC) also demonstrated high sensitivity (91%) and specificity (100%): an optimal cut-off of 399 mg/L distinguished between myeloma and non-myeloma AKI patients. We propose a pathway of patient screening and stratification in unexplained AKI for use of Seralite® in clinical practice, with a κ:λ ratio range of 0.14-2.02 and dFLC 400 mg/L as decision points. CONCLUSIONS: Seralite® accurately differentiates between AKI due to MM and AKI due to other causes in patients considered at risk of myeloma. This rapid test can sensitively screen for MM in patients with AKI and help inform early treatment intervention.


Asunto(s)
Lesión Renal Aguda/sangre , Lesión Renal Aguda/diagnóstico , Cadenas Ligeras de Inmunoglobulina/sangre , Mieloma Múltiple/sangre , Mieloma Múltiple/diagnóstico , Lesión Renal Aguda/epidemiología , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Mieloma Múltiple/epidemiología , Estudios Retrospectivos , Factores de Tiempo , Adulto Joven
4.
J Immunol Methods ; 478: 112713, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31783021

RESUMEN

BACKGROUND: Polyclonal FLCs can be used as a biomarker of inflammation and immune activation in a range of diseases. This study evaluated the performance of new FLC ELISAs (Seralite FLC ELISA) for the quantitation of polyclonal κ and λ FLC, including comparisons to existing assays. METHODS: Technical performance was assessed for the ELISA and reference ranges were generated using healthy donor serum (N = 91). Patients with a range of conditions associated with polyclonal FLC dysregulation (N = 164) were measured across platforms. RESULTS: The ELISAs generated references ranges of: 8.72-23.0 mg/L κ FLC, and 8.52-25.24 mg/L for λ FLC. ELISAs demonstrated linearity across the calibration range and intra-assay (≤ 8.7%) and inter-assay (≤ 12.3%) imprecision was low. The limit of detection was 0.63 mg/L for κ and 0.57 mg/L for λ FLC. Minimal cross-reactivity was observed for interference agents, alternate FLC and whole immunoglobulin (median change ≤3.6 mg/L). Assays showed good batch-to-batch consistency. For patient samples, methods generated different κ and λ FLC concentrations and differences were seen between methods for the number of patients classified as below, with and above references ranges for κ and λ FLC. There was no significant difference in the FLC sum between the different techniques. CONCLUSIONS: The ELISAs displayed good analytical and technical performance. The quantification of individual κ and λ FLC appears inherently different between platforms. These differences are attenuated if using the FLC sum, which was similar between methods and provided agreement in relation to patients having normal or elevated FLCs.


Asunto(s)
Enfermedades del Sistema Inmune/diagnóstico , Cadenas kappa de Inmunoglobulina/aislamiento & purificación , Cadenas lambda de Inmunoglobulina/aislamiento & purificación , Juego de Reactivos para Diagnóstico , Biomarcadores/sangre , Conjuntos de Datos como Asunto , Ensayo de Inmunoadsorción Enzimática/instrumentación , Ensayo de Inmunoadsorción Enzimática/métodos , Voluntarios Sanos , Humanos , Enfermedades del Sistema Inmune/sangre , Enfermedades del Sistema Inmune/inmunología , Cadenas kappa de Inmunoglobulina/sangre , Cadenas kappa de Inmunoglobulina/inmunología , Cadenas lambda de Inmunoglobulina/sangre , Cadenas lambda de Inmunoglobulina/inmunología , Valores de Referencia , Reproducibilidad de los Resultados , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA