1.
Radiol Med ; 129(1): 14-28, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37863847

RESUMEN

OBJECTIVE: Exploring the efficacy of a Radiological-Clinical (Rad-Clinical) model in predicting prognosis of unresectable hepatocellular carcinoma (HCC) patients after drug eluting beads transcatheter arterial chemoembolization (DEB-TACE) to optimize the targeted sequential treatment. METHODS: In this retrospective analysis, we included 202 patients with unresectable HCC who received DEB-TACE treatment in 17 institutions from June 2018 to December 2022. Progression-free survival (PFS)-related radiomics features were computationally extracted from HCC patients to build a radiological signature (Rad-signature) model with least absolute shrinkage and selection operator regression. A Rad-Clinical model for postoperative PFS was further constructed according to the Rad-signature and clinical variables by Cox regression analysis. It was presented as a nomogram and evaluated by receiver operating characteristic curves, calibration curves, and decision curve analysis. And further evaluate the application value of Rad-Clinical model in clinical stages and targeted sequential therapy of HCC. RESULTS: Tumor size, Barcelona Clinic Liver Cancer (BCLC) stage, and radiomics score (Rad-score) were found to be independent risk factors for PFS after DEB-TACE treatment for unresectable HCC, with the Rad-Clinical model being the greatest predictor of PFS in these patients (hazard ratio: 2.08; 95% confidence interval: 1.56-2.78; P < 0.001) along with high 6 months, 12 months, 18 months, and 24 months area under the curves of 0.857, 0.810, 0.843, and 0.838, respectively. In addition, compared to the radiomics and clinical nomograms, the Radiological-Clinical nomogram also significantly improved the classification accuracy for PFS outcomes, based on the net reclassification improvement (45.2%, 95% CI 0.260-0.632, p < 0.05) and integrated discrimination improvement (14.9%, 95% CI 0.064-0.281, p < 0.05). Based on this model, low-risk patients had higher PFS than high-risk patients in BCLC-B and C stages (P = 0.021). Targeted sequential therapy for patients with high and low-risk HCC in BCLC-B stage exhibited significant benefits (P = 0.018, P = 0.012), but patients with high-risk HCC in BCLC-C stage did not benefit much (P = 0.052). CONCLUSION: The Rad-Clinical model may be favorable for predicting PFS in patients with unresectable HCC treated with DEB-TACE and for identifying patients who may benefit from targeted sequential therapy.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/patología , Nomogramas , Estudios Retrospectivos , Terapia Molecular Dirigida , Resultado del Tratamiento
2.
J Thromb Thrombolysis ; 52(2): 628-634, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33835336

RESUMEN

To evaluate the age of caval thrombus that experimentally induced in swine by use of magnetic resonance imaging (MRI). Caval thrombus was experimentally created in 15 swine by autologous clot injection assisted with caval net knitting. Serial high-resolution MR images were obtained using magnetic resonance venography (MRV) and T1 high-resolution isotropic volume examination (THRIVE) sequences in a 3.0-T MR system at 1, 7, 14, 21, and 28 days post model creation. At each time point, three pigs were sacrificed and the thrombotic vena cava was processed for histopathological examinations respectively. Caval thrombus was successfully induced in 15 pigs in group A. The signal intensity (SI) change of caval thrombus on THRIVE was age-dependent, with a typical sign of circle or semi-circle hyper-intensity at 7-day-old model while SI of thrombus was lower than that of muscle from day 14 throughout day 28. The histo-pathological findings revealed that RBCs-rich thrombus at day 1 without blue-stained particles, RBCs layers with infiltration of inflammatory cells and sporadically distributed blue-stained particles at 7-day-old thrombus. At day 14, 21 and 28, blue-stained particles became richer, coupled with formation of granulation tissue and fibrous tissue. The swine model in the study is good for age evaluation of venous thrombosis. The peripheral circle or semi-circle hyperintensity on THRIVE indicates the young age of caval thrombus in swine.


Asunto(s)
Trombosis , Trombosis de la Vena , Animales , Imagen por Resonancia Magnética , Porcinos , Vena Cava Inferior/diagnóstico por imagen , Venas Cavas
3.
Microvasc Res ; 123: 81-85, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30576698

RESUMEN

OBJECTIVE: To evaluate perfusion alterations in skeletal muscle in a canine hind limb ischemia model using color-coded digital subtraction angiography (CC-DSA). METHODS: Twelve beagles underwent embolization at the branch of their left deep femoral artery. Right hind limbs were used as the control group. Angiography was performed before and immediately after embolization. Upon CC-DSA analysis, time to peak (TTP) was measured before embolization in both sides of the beagles' hind limbs at the middle iliac artery, and the distant, middle and proximal femoral artery. Regions of interest (ROI) peak and ROI peak time were symmetrically computed in proximal and distal thigh muscles before and immediately after embolization. The data were analyzed and compared using the Wilcoxon signed rank test. RESULTS: Before embolization, ROI peak in the proximal thigh was lower than in the ipsilateral distal thigh, whereas ROI peak time in the proximal thigh was longer than in the distal thigh. In the iliac femoral artery, there was no significant difference in ROI peak, ROI peak time, or TTP between right and left sides. After embolization, ROI peaks in proximal and distal skeletal muscles of the left hind limb were significantly lower than on the contralateral side. ROI peak time was significantly longer in the left proximal and left distal thigh compared to the contralateral side. There were no significant changes in ROI peak or ROI peak time in the right proximal and right distal thigh compared to pre-embolization values. Changes in ROI peak and ROI peak time were larger in the left proximal than in the left distal thigh. CONCLUSION: CC-DSA provided real-time measurement of changes in vascular hemodynamics and skeletal muscle perfusion without increasing X-ray usage or contrast agent dose.


Asunto(s)
Angiografía de Substracción Digital/métodos , Hemodinámica , Isquemia/diagnóstico por imagen , Músculo Esquelético/irrigación sanguínea , Imagen de Perfusión/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Animales , Velocidad del Flujo Sanguíneo , Modelos Animales de Enfermedad , Perros , Femenino , Miembro Posterior , Isquemia/inducido químicamente , Isquemia/fisiopatología , Masculino , Alcohol Polivinílico , Valor Predictivo de las Pruebas , Flujo Sanguíneo Regional , Factores de Tiempo
4.
J Vasc Interv Radiol ; 30(1): 43-48, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30527655

RESUMEN

PURPOSE: To review preliminary efficacy and safety outcomes of mechanical thrombectomy using the Solitaire AB device combined with thromboaspiration for treatment of acute embolic occlusion of the superior mesenteric artery (SMA). MATERIALS AND METHODS: Between October 2015 and October 2017, 9 patients (average age, 77 y; range, 62-84 y) presenting with acute mesenteric ischemia attributable to embolic occlusion at the stem of the SMA were retrospectively evaluated for mechanical thrombectomy using the Solitaire AB device combined with manual thromboaspiration. Adjunctive stent implantation was performed to correct pre-existing atherosclerotic stenosis or as a rapid recanalization solution after unsuccessful thrombectomy. Technical success was defined as successful deployment of the Solitaire device across the thrombus and successful retrieval of the device. Clinical success was defined as successful embolus retrieval and SMA recanalization. Adjunctive procedures and periprocedural complications were noted. Technical success, clinical success, and follow-up outcomes were assessed. RESULTS: Technical success was achieved in all patients. Clinical success was achieved in 7 (78%) patients. An adjunctive stent was required in 3 (33%) patients, including 1 unsuccessful thrombectomy. All patients had notable relief from abdominal pain after the procedure. No device-related complications or distal embolization events were noted during the procedures. Bowel resection was prevented in all patients. In-hospital mortality was 11% (1/9). During median follow-up of 6 months (range, 3-12 months), all surviving patients remained symptom-free, and stent patency was achieved in all patients. CONCLUSIONS: Preliminary outcomes suggest that mechanical thrombectomy using the Solitaire AB device with manual thromboaspiration is associated with rapid, effective, and safe recanalization for acute embolic occlusion at the stem of the SMA.


Asunto(s)
Embolia/cirugía , Arteria Mesentérica Superior/cirugía , Isquemia Mesentérica/cirugía , Oclusión Vascular Mesentérica/cirugía , Stents , Trombectomía/instrumentación , Enfermedad Aguda , Anciano , Anciano de 80 o más Años , Angiografía por Tomografía Computarizada , Embolia/diagnóstico por imagen , Embolia/mortalidad , Embolia/fisiopatología , Diseño de Equipo , Estudios de Factibilidad , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Arteria Mesentérica Superior/diagnóstico por imagen , Arteria Mesentérica Superior/fisiopatología , Isquemia Mesentérica/diagnóstico por imagen , Isquemia Mesentérica/mortalidad , Isquemia Mesentérica/fisiopatología , Oclusión Vascular Mesentérica/diagnóstico por imagen , Oclusión Vascular Mesentérica/mortalidad , Oclusión Vascular Mesentérica/fisiopatología , Persona de Mediana Edad , Datos Preliminares , Estudios Retrospectivos , Circulación Esplácnica , Succión , Trombectomía/efectos adversos , Trombectomía/métodos , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
5.
BMC Cardiovasc Disord ; 18(1): 64, 2018 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-29642860

RESUMEN

BACKGROUND: A permanently indwelling filter in the inferior vena cava (IVC) may induce caval thrombosis, which could develop and evolve from an acute to a chronic phase. The differential diagnosis of acute and chronic thromboses determines the treatment strategy. The role of computed tomography (CT) in diagnosing acute and chronic intra-filter and IVC thromboses has not been well established. This retrospective study summarizes the CT signs that indicate acute and chronic phases of intra-filter and IVC thromboses. METHODS: This study included eight patients who developed a lower-extremity deep venous thrombosis (DVT) and were treated with intracaval filter placement as an alternative to anticoagulation and thrombolysis. During the follow-up, all patients developed an intra-filter thrombosis in the IVC confirmed by CT and/or CT venography (CTV). Demographic and CT data of all patients during the follow-up period were collected for analysis. RESULTS: All patients had normal-appearing IVCs prior to filter placement, as shown on trans-femoral venography. Eight filters (five TrapEase, three OptEase) were placed in the eight IVCs, respectively. Subsequently, IVC-CT or CTV revealed acute intra-filter or IVC thrombosis in all eight patients, manifesting as an intracaval filling defect and thickened IVC wall. Filter protrusion and secondary caval atrophy seen on CT indicated a chronically occluded IVC. CONCLUSIONS: IVC thrombosis may result from filter placement. The chronicity of caval thrombotic occlusion is likely to be associated with filter protrusion and secondary IVC atrophy revealed on CT scans.


Asunto(s)
Extremidad Inferior/irrigación sanguínea , Filtros de Vena Cava/efectos adversos , Vena Cava Inferior/diagnóstico por imagen , Trombosis de la Vena/terapia , Atrofia , Angiografía por Tomografía Computarizada , Humanos , Flebografía/métodos , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Vena Cava Inferior/patología , Trombosis de la Vena/diagnóstico por imagen
6.
J Thromb Thrombolysis ; 45(3): 440-451, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29417407

RESUMEN

To review the clinical evidence for ultrasound-accelerated catheter-directed thrombolysis (UACDT) using the EKOS system in the treatment of deep vein thrombosis (DVT) in terms of case selection, procedural outcomes, clinical outcomes and safety outcomes. A systematic literature search strategy was used to identify the use of the EKOS system in the treatment of DVT using the following electronic databases: MEDLINE, EMBASE, the Cochrane databases and the Web of Science. The references in the relevant literature were also screened. Our literature search identified a total of 16 unique clinical studies. Twelve of the sixteen studies were retrospective case series studies. To date, only one randomised controlled trial (RCT) is available. Overall, UACDT using the EKOS system was performed 548 times in 512 patients. Among all cases, 77-100% achieved substantial lysis (> 50%) based on the different definitions of the individual studies. This treatment modality appears to be safe, as there were no reported procedure-related pulmonary embolisms (PE) and only one procedure-related death was reported. Bleeding events were reported in 14 of the 16 studies, and 3.9% (20/512) of the cases of bleeding were considered major. During the follow-up, post-thrombotic syndrome was observed in 17.1% (20/117) of cases. UACDT using the EKOS system is an effective, safe and promising treatment modality for DVT, but the existing clinical evidence is inadequate to make UACDT using the EKOS system the first-line choice for DVT. Additional prospective large-sample RCTs with long-term follow-ups are warranted to define the role of UACDT using the EKOS system in the treatment of DVT.


Asunto(s)
Terapia Trombolítica/métodos , Trombosis de la Vena/tratamiento farmacológico , Humanos , Ondas Ultrasónicas
7.
J Vasc Interv Radiol ; 27(6): 852-8, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27106733

RESUMEN

PURPOSE: To confirm the feasibility of using time-to-peak (TTP) measurements derived from color-coded digital subtraction angiography (ccDSA) imaging to assess improvements in distal circulation in relation to the ankle-brachial index (ABI). MATERIALS AND METHODS: Nineteen patients who underwent percutaneous transluminal angioplasty and/or stent placement (in 20 lower extremities) were evaluated. A region of interest (ROI) at the proximal superficial femoral artery (SFA) was selected for a reference TTP for quantitative assessments. The ROI measurements of the TTP interval between medial and lateral plantar/dorsalis pedis relative to the reference was regarded as the ΔTTP and used to assess distal hemodynamic improvement achieved by the revascularization. The ABI was obtained with a handheld Doppler ultrasound machine with a manually operated blood-pressure cuff. Correlation between the two methods was analyzed. RESULTS: The ABI improved significantly from 0.44 ± 0.18 to 0.79 ± 0.20 (t = 10.11; P < .0001) after the intervention. TTP, which reflected the blood flow time from the proximal SFA to the foot, became much faster, from 11.86 seconds ± 4.26 to 6.75 seconds ± 2.03 (t = 6.57; P < .001). A good correlation was observed between the improvement ratios of ΔTTP and ABI (r = 0. 863). CONCLUSIONS: TTP measurements derived from ccDSA provide an easy and objective method for assessment of distal hemodynamic changes after endovascular treatment of lower-extremity peripheral arterial disease (PAD). It may provide a quantitative method to assess the adequacy of endovascular interventions and provide more objective suggestions for procedure endpoints, with potentially better clinical outcomes for patients with PAD.


Asunto(s)
Angiografía de Substracción Digital/métodos , Angioplastia de Balón , Índice Tobillo Braquial , Arteria Femoral/diagnóstico por imagen , Hemodinámica , Extremidad Inferior/irrigación sanguínea , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Interpretación de Imagen Radiográfica Asistida por Computador , Anciano , Angioplastia de Balón/instrumentación , Velocidad del Flujo Sanguíneo , Estudios de Factibilidad , Femenino , Arteria Femoral/fisiopatología , Humanos , Masculino , Enfermedad Arterial Periférica/fisiopatología , Valor Predictivo de las Pruebas , Recuperación de la Función , Flujo Sanguíneo Regional , Estudios Retrospectivos , Stents , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Doppler
8.
Artículo en Inglés | MEDLINE | ID: mdl-26429414

RESUMEN

OBJECTIVE: Endoleaks constitute the main concern regarding the use of covered stents in the treatment of intracranial aneurysms. We investigated immediate/late endoleaks after stent-graft placement for the treatment of experimentally created carotid fusiform aneurysm (FA) in a canine model. MATERIAL AND METHODS: Eighteen carotid FAs in nine dogs receiving covered stents were followed. Their procedural and angiographic data were collected immediately and six months after stenting. Univariate analysis and multivariate logistic regression analysis were performed to determine the factors predictive of immediate/late endoleaks. Receiver operating characteristic curve analysis was performed to determine the best cutoff values of the independent factors. RESULTS: All carotid FAs were successfully treated with Willis covered stents and received a six-month follow-up. The rate of immediate and late endoleaks after stenting was 38.89% and 16.67%, respectively. Anchoring length was identified as independent predictor of immediate endoleaks (P =0.037) and its best cutoff value was 3.06 mm (95% confidence interval: 2.39-3.72). No parameters were identified to be independent predictors of late endoleaks. CONCLUSIONS: Treating carotid FAs with Willis covered stents is technically feasible. Most endoleaks heal spontaneously and significantly correlate with anchoring length.


Asunto(s)
Aneurisma/cirugía , Enfermedades de las Arterias Carótidas/cirugía , Endofuga/epidemiología , Procedimientos Endovasculares/métodos , Angiografía , Animales , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Modelos Animales de Enfermedad , Perros , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Estudios de Factibilidad , Estudios de Seguimiento , Modelos Logísticos , Análisis Multivariante , Stents
9.
Eur J Pharm Biopharm ; 202: 114384, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38950718

RESUMEN

Peripheral vascular condition, known as deep vein thrombosis (DVT), is a common ailment that may lead to deadly pulmonary embolism. Inflammation is closely connected to venous thrombosis, which results in blood stasis, leading to ischemia and hypoxia, as indicated by research. The objective of this research was to investigate the mechanism by which exosomes derived from adipose stem cells (ADSCs) prevent deep vein thrombosis. Our data showed that Exo-483 effectively reduced the thrombus weight in DVT rats by intravenous injection. Exo-483 decreased the expression of tissue factor (TF) protein, the influx of inflammatory cells into the thrombosed vein wall, and the levels of cytokines in the serum. Furthermore, Exo-483 suppressed the expression of Mitogen-activated protein kinase 1 (MAPK1) and decreased the expression of NLRP3 inflammasomes. In an oxygen-glucose deprivation (OGD) cell model, the tube-forming and migratory abilities of primary human umbilical vein endothelial cells (HUVEC) and EA.hy926 cells were suppressed by Exo-483 pretreatment.Exo-483 is also linked to regulating Dynamin-related protein 1 (DRP1) production downstream of MAPK1.By decreasing the mitochondrial localization and phosphorylation at the S616 site of DRP1, it diminishes the expression of NLRP3 inflammasomes. Moreover, according to Bioinformatics analysis, miR-483-5p was anticipated to target MAPK1. The research conducted by our team revealed that the miR-483-5p exosome derived from ADSCs exhibited anti-inflammatory properties through the modulation of downstream DRP1-NLRP3 expression by targeting MAPK1.The findings of this research propose that miR-483-5p may be regarded as an innovative treatment target for DVT.


Asunto(s)
Exosomas , Células Endoteliales de la Vena Umbilical Humana , Inflamación , MicroARNs , Trombosis de la Vena , Exosomas/metabolismo , Animales , Trombosis de la Vena/metabolismo , Humanos , MicroARNs/genética , MicroARNs/metabolismo , Ratas , Masculino , Células Endoteliales de la Vena Umbilical Humana/metabolismo , Inflamación/metabolismo , Proteína con Dominio Pirina 3 de la Familia NLR/metabolismo , Proteína con Dominio Pirina 3 de la Familia NLR/genética , Ratas Sprague-Dawley , Dinaminas/metabolismo , Dinaminas/genética , Tejido Adiposo/metabolismo , Inflamasomas/metabolismo , Citocinas/metabolismo , Modelos Animales de Enfermedad , Células Madre/metabolismo
10.
Acad Radiol ; 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38508935

RESUMEN

RATIONALE AND OBJECTIVES: Transarterial chemoembolization (TACE) plus molecular targeted therapies has emerged as the main approach for treating hepatocellular carcinoma (HCC) with portal vein tumor thrombus (PVTT). A robust model for outcome prediction and risk stratification of recommended TACE plus molecular targeted therapies candidates is lacking. We aimed to develop an easy-to-use tool specifically for these patients. METHODS: A retrospective analysis was conducted on 384 patients with HCC and PVTT who underwent TACE plus molecular targeted therapies at 16 different institutions. We developed and validated a new prognostic score which called ABPS score. Additionally, an external validation was performed on data from 200 patients enrolled in a prospective cohort study. RESULTS: The ABPS score (ranging from 0 to 3 scores), which involves only Albumin-bilirubin (ALBI, grade 1: 0 score; grade 2: 1 score), PVTT(I-II type: 0 score; III-IV type: 1 score), and systemic-immune inflammation index (SII,<550 × 1012: 0 score; ≥550 × 1012: 1 score). Patients were categorized into three risk groups based on their ABPS score: ABPS-A, B, and C (scored 0, 1-2, and 3, respectively). The concordance index (C-index) of the ABPS scoring system was calculated to be 0.802, significantly outperforming the HAP score (0.758), 6-12 (0.712), Up to 7 (0.683), and ALBI (0.595) scoring systems (all P < 0.05). These research findings were further validated in the external validation cohorts. CONCLUSION: The ABPS score demonstrated a strong association with survival outcomes and radiological response in patients undergoing TACE plus molecular targeted therapy for HCC with PVTT. The ABPS scoring system could serve as a valuable tool to guide treatment selection for these patients.

11.
Neurol Sci ; 34(7): 1065-70, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22986636

RESUMEN

We report our findings associated with the differential diagnosis of infundibular dilation (ID) versus a small intracranial aneurysm using three-dimensional rotational angiography with volume rendering (3DRA + VR). Angiographic findings associated with IDs found via two-dimensional digital subtraction angiography (2D-DSA) or 3DRA + VR were reviewed for 138 consecutive patients with known or suspected aneurysms. Two readers independently evaluated the results of 2D-DSA and 3DRA + VR according to the same diagnostic criteria. We also evaluated the ability of 3D-DSA to show the spatial relation between IDs and anterior choroidal (AchA)/posterior communicating (PcomA) arteries. 2D-DSA and 3DRA + VR found 41 and 48 IDs, respectively. 2D-DSA missed five AchA and two PcomA IDs. 2D-DSA was significantly inferior to 3DRA + VR for displaying the spatial relation between IDs and AchA/PcomA (P = 0). Thus, 3DRA + VR provides more useful information for distinguishing IDs from aneurysms. The superiority of 3DRA + VR might be because of its ability to display the spatial relation between IDs and AchA/PcomA.


Asunto(s)
Arteria Carótida Interna/diagnóstico por imagen , Imagenología Tridimensional/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Angiografía por Resonancia Magnética/métodos , Neurohipófisis/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Femenino , Humanos , Aneurisma Intracraneal/diagnóstico , Aneurisma Intracraneal/fisiopatología , Masculino , Persona de Mediana Edad , Neurohipófisis/fisiopatología , Radiografía , Adulto Joven
12.
Neurol India ; 61(1): 45-50, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23466839

RESUMEN

BACKGROUND: The covered stent is one of the most promising tools for the treatment of intracranial fusiform aneurysms. We developed an in vivo model of fusiform aneurysms and evaluated the effectiveness of double telescoping Willis covered stents for their treatment. MATERIALS AND METHODS: An external jugular vein graft was anastomosed with the common carotid artery (CCA) to construct the fusiform aneurysm model. After at least 4 weeks, two Willis covered stents were implanted in a telescopic fashion. Angiography follow-up was performed at 2 weeks and 1 and 3 months to examine the grafts. The animals were sacrificed at 1 or 3 months of the follow-up period, and the stents were examined histologically. RESULTS: A total of eight fusiform aneurysms in four canines were created and 16 covered stents were implanted successfully. No technical or device-related difficulties occurred. The angiographic follow-up results showed that six fusiform aneurysms were completely occluded, and a minimal endoleak occurred in two fusiform aneurysms. Histological examination revealed endothelial progress and all aneurysm sacs were filled with thrombi. CONCLUSION: Vein graft anastomosis with CCA to construct a model of fusiform aneurysm may reproduce the clinical conditions. This study demonstrated that the implantation of two Willis covered stents in a telescoping fashion is an effective way to treat an experimental model of fusiform aneurysm.


Asunto(s)
Aneurisma Intracraneal , Stents , Angiografía , Animales , Arteria Carótida Común/diagnóstico por imagen , Perros , Aneurisma Intracraneal/cirugía , Resultado del Tratamiento
13.
Fitoterapia ; 168: 105465, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36863569

RESUMEN

An effort to identify novel active substances of the prepared folium of Epimedium sagittatum Maxim. (PFES) that was an important herb for male erectile dysfunction (ED) was taken. At present, phosphodiesterase-5A (PDE5A) is the most important target of new drugs for the treatment of ED. Therefore, the inhibition ingredients in PFES were systematically screened for the first time in this study. Eleven compounds, including eight new flavonoids and three prenylhydroquinones were isolated: sagittatosides DN (1-11), and their structures were elucidated by spectra and chemical analyses. Among them, a novel prenylflavonoid with oxyethyl group (1) was obtained and three prenylhydroquinones (9-11) were firstly isolated from Epimedium. All compounds were analyzed for the inhibition against PDE5A by molecular docking, and they all showed significant binding affinity as same as sildenafil. Their inhibitory activities were verified, and the results showed compound 6 had significant inhibition against PDE5A1. The isolation of new flavonoids and prenylhydroquinones with inhibitory activities of PDE5A from PFES implied that this herb might be a good source for the treatment of ED agents finding.


Asunto(s)
Epimedium , Flavonoides , Epimedium/química , Epimedium/metabolismo , Simulación del Acoplamiento Molecular , Estructura Molecular , Citrato de Sildenafil/metabolismo
14.
Chin Med ; 17(1): 147, 2022 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-36587222

RESUMEN

BACKGROUND: As known, inhibition of phosphodiesterase 5 (PDE5) has the therapeutic effect on male erectile dysfunction (ED), and the processed folium of Epimedium sagittatum Maxim. (PFES) characterized by 8-isopentenyl flavonoids is a famous herb for treating ED. However, the main flavonoids inhibitory activities, structure-activity relationship (SAR) and signaling pathway have been not systematically studied so that its pharmacodynamic mechanism is unclear. METHODS: We aimed to initially reveal the PFES efficacy mechanism for treating ED. For the first time, 6 main 8-isopentenyl flavonoids (1-6) from PFES were isolated and identified. Then based on HPLC detection, we proposed a novel method to screen inhibitors among them. We further analyze the three-dimensional quantitative structure-activity relationship (3D-QSAR) for those inhibitors. RESULTS: The results were verified by cellular effects of the screened flavonoids. Among 6 compounds, Icariin: (1), 2-O''rhamnosylicaridide II (2) and Baohuoside I (3) were identified with significant activities (IC50 = 8.275, 3.233, 5.473 µM). Then 3D-QSAR studies showed that the replacement of C8 with bulky steric groups as isopentenyl, C3 with positive charge groups and C4' with a hydrogen bond acceptor substituent could increase inhibitory effects. In contrast, the substitution of C7 with bulky steric groups or hydrophilic groups tended to decrease the efficacies. And compounds 1, 2, 3 could increase cGMP level and decrease cytoplasmic Ca2+ of rat corpus cavernosum smooth muscle cells (CCSMCs)by activating PKG. CONCLUSION: 8-isopentenyl flavonoids could be the main pharmacodynamic substances of PFES in the treatment for ED, and some had significant PDE5A1 inhibitory activities so as to activate cGMP/PKG/Ca2+ signaling pathway in CCSMCs, that was related to the substituents at the key sites such as C8, C3, C4' and C7 in the characteristic compounds.

15.
Surg Radiol Anat ; 33(1): 75-80, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20857293

RESUMEN

PURPOSE: Whether an infundibular dilation (ID) is an anatomical variant or a pre-aneurysm has not been clearly determined. The aim of the present study was to evaluate the anatomical change of IDs by use of three-dimensional rotational angiography (3DRA) with volume rendering (VR). METHODS: One-hundred thirty-eight patients with known or suspected aneurysms, treated consecutively, underwent both two-dimensional digital subtraction angiography (2DDSA) and 3DRA with VR. Two readers evaluated the IDs or aneurysms blindly, using 2DDSA and 3DRA, according to the same diagnostic criteria. A 5-point scale of observer confidence was used to determine the presence of IDs or aneurysms. For 3DRA with VR, the relationship between IDs and aneurysms was classified as one of the three types: type I, protrusion or bulge from side wall of IDs; type II, aneurysms involving or enclosing IDs; or type III, aneurysms and IDs coexisting near each other but with some distance between them. RESULTS: The number of IDs found by 2DDSA and 3DRA with VR was 41 and 48, respectively. Five anterior choroidal arteries and two posterior communicating arteries IDs were missed by 2DDSA. According to 3DRA with VR, there were five IDs of type I, nine of type II, and 22 of type III. CONCLUSIONS: The 3DRA with VR appears superior to 2DRA for both diagnosing IDs and displaying the anatomical relationship between IDs and aneurysms. The findings also suggest that some IDs might progress to aneurysms or become a part of them, which should be carefully evaluated prior to operation.


Asunto(s)
Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/etiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Arteria Carótida Interna/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
16.
Abdom Radiol (NY) ; 46(9): 4432-4439, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33866382

RESUMEN

OBJECTIVE: To evaluate the diagnostic accuracy of a contrast-free multimodal magnetic resonance (MR) protocol (including M2DIPEAR, THRIVE, BTFE-SPAIR, and FLAIR sequences) in the detection of iliac vein obstruction with or without thrombosis. MATERIALS AND METHODS: From May 1st, 2015, to May 1st, 2016, a total of 73 patients (aged 51.33 ± 4.21 years) who received both digital subtraction angiography (DSA) and the multimodal MR imaging were included. The protocol of the multimodal MR included M2DIPEAR and BTFE-SPAIR for presenting iliac vein obstruction, and THRIVE and FLAIR for revealing the co-existed thrombosis. Three observers who were blinded to clinical and DSA results independently analyzed all multimodal MR datasets. Per-patient evaluations on presence or absence of iliac vein obstruction were performed to calculate the diagnostic performance of MR imaging (DSA regarded as gold reference) in terms of overall accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Capability to display the co-existing venous thrombus was also evaluated per-MR sequence using a 3-point scale system. RESULTS: Iliac vein obstruction was depicted with DSA in 64 patients. In per-patient evaluation, the multimodal MR imaging yielded accuracy of 95.9% (70/73), sensitivity of 96.9% (62/64), specificity of 88.9% (8/9), positive predictive value of 98.4% (62/63), and negative predictive value of 80% (8/10), respectively. In the multimodal MR sequences, balanced turbo field echo-spectral attenuated inversion recovery (BTFE-SPAIR) sequence was superior to other sequences in depicting the iliac vein configuration, but fluid attenuated inversion recovery (FLAIR) and T1 high-resolution isovolumetric examination (THRIVE) seemed superior in detecting co-existing venous thrombosis. CONCLUSIONS: M2DIPEAR and BTFE-SPAIR sequence can reveal iliac vein obstruction while THRIVE and FLAIR can detect the co-existed thrombosis. The proposed multimodal MR protocol can accurately depict the iliac vein obstruction and accurately detect the co-existing venous thrombosis comparable with that of DSA.


Asunto(s)
Vena Ilíaca , Trombosis de la Vena , Humanos , Vena Ilíaca/diagnóstico por imagen , Angiografía por Resonancia Magnética , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Sensibilidad y Especificidad , Trombosis de la Vena/complicaciones , Trombosis de la Vena/diagnóstico por imagen
17.
Biomed Pharmacother ; 135: 111248, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33450505

RESUMEN

Cordyceps militaris has been widely studied for its various pharmacological activities such as antitumor, anti-inflammation, and immune regulation. The binding of an allergen to IgE-sensitized mast cells in nasal mucosa triggers allergic rhinitis. We found that oral administration of 300 mg/kg of the ethanol extract prepared from silkworm pupa-cultivated Cordyceps militaris fruiting bodies significantly alleviated the symptoms of ovalbumin-induced allergic rhinitis in mice, including sneeze/scratch, mast cell activation, eosinophil infiltration, and Syk activation. The treatment of ethanol extract significantly suppressed the release of ß-hexosaminidase (a degranulation marker) and mRNA expression levels of various cytokines, including IL-3, IL-10, and IL-13 in activated RBL2H3 cells. The ethanol extract and ß-sitostenone, which was purified from the extract, could respectively reduce the Ca2+ ion mobilization in activated RBL-2H3 cells. Furthermore, results collected from western immunoblotting demonstrated that ethanol extract significantly retarded Ca2+ ion mobilization-initiated signaling cascade, which provoked the expression of various allergic cytokines. Also, the extract incubation interfered with P38 as well as NF-kB activation and Nrf-2 translocation. Our study suggested that ethanol extract possessed some natural constituents which could inhibit immediate degranulation and de novo synthesis of allergic cytokines via inhibition of Ca2+ ion mobilization in mast cells in the nasal mucosa of allergic rhinitis mice.


Asunto(s)
Antialérgicos/farmacología , Bombyx/metabolismo , Cordyceps/fisiología , Cuerpos Fructíferos de los Hongos/fisiología , Mucosa Nasal/efectos de los fármacos , Rinitis Alérgica/prevención & control , Animales , Antialérgicos/aislamiento & purificación , Bombyx/embriología , Señalización del Calcio , Degranulación de la Célula/efectos de los fármacos , Línea Celular Tumoral , Citocinas/metabolismo , Modelos Animales de Enfermedad , Etanol/química , Larva/metabolismo , Masculino , Mastocitos/efectos de los fármacos , Mastocitos/inmunología , Mastocitos/metabolismo , Ratones Endogámicos BALB C , Mucosa Nasal/inmunología , Mucosa Nasal/metabolismo , Ovalbúmina , Ratas , Rinitis Alérgica/inducido químicamente , Rinitis Alérgica/inmunología , Rinitis Alérgica/metabolismo , Solventes/química
18.
Neurol India ; 58(6): 908-13, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-21150058

RESUMEN

AIMS: The advent of three-dimensional (3D) rotational angiography (3D DSA) challenged the role of digital subtraction angiography (DSA) as a "gold standard" in the diagnosis of intracranial aneurysms. In this study, we report our experiences in diagnosing intracranial aneurysms by using 3D DSA with volume rendering (VR) technique, particularly focusing on its role in depicting additional aneurysms missed by 2D DSA. MATERIALS AND METHODS: One hundred and thirty-eight consecutive patients with known or suspected aneurysms (54 men, 84 women; median age, 55 years; age range, 18-83 years) underwent both conventional DSA and 3D DSA with VR examination simultaneously. The images of 2D DSA or 3D DSA with VR were evaluated by two observers independently for the presence of aneurysms. Then additional aneurysms were decided and depicted. RESULTS: 3D DSA with VR showed 146 aneurysms in 123 (89.1%) of 138 patients and no aneurysms in 15 patients. 2D DSA showed 115 aneurysms in 110 of 137 patients, with one aneurysm in 106 patients each, 2 in 3 patients each and 3 in 1 patient. After reaching a consensus, there were 31 additional aneurysms detected by 3D DSA with VR. 30 aneurysms were <3 mm in maximum diameter with 3 aneurysms ruptured. These additional aneurysms were located in internal carotid artery (ICA, n = 28, 90.32%), anterior cerebral artery (ACA, n = 3, 9.68%). No additional aneurysms were found in either middle cerebral artery (MCA) or vertebrobasilar and posterior cerebral artery (PCA) systems. CONCLUSIONS: 3D DSA, especially VR images, not only clearly reveals aneurysms and aneurysmal morphology, but also detects additional aneurysms missed by 2D DSA, especially small aneurysms less than 3 mm.


Asunto(s)
Angiografía de Substracción Digital/métodos , Mapeo Encefálico , Angiografía Cerebral/métodos , Imagenología Tridimensional/métodos , Aneurisma Intracraneal/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Aneurisma Intracraneal/patología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
19.
J Thorac Imaging ; 35(4): 260-264, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32032250

RESUMEN

OBJECTIVE: We sought to introduce a localization procedure (methylene blue-stained N-butyl cyanoacrylate and N-octyl cyanoacrylate glue) in localizing pulmonary small nodules and ground-glass opacities before thoracoscopic resection, and to evaluate its efficacy. METHODS: A total of 20 patients with pulmonary small nodules and/or ground-glass opacities, who underwent video-assisted thoracoscopic surgery from August 1, 2017 to March 1 2018, were included in the study. RESULTS: A total of 24 lesions in 20 patients underwent blue-stained glue localization. The success rate of localization was 100%, with a mean dose of 0.04±0.01 mL blue dye and 1 mL glue used for each lesion. The average time for the whole localization procedure was 15.4±6.3 minutes. All lesions were intraoperatively localized by visual inspection in combination with palpation. The complications related to the localization procedure included mild pneumothorax occurring in 9 patients and minor pulmonary hematoma in 4 patients. No pain or distress was reported. CONCLUSIONS: Blue-stained glue injection is technically feasible and safe to localize pulmonary small nodules and ground-glass opacities before thoracoscopic resection.


Asunto(s)
Cianoacrilatos/administración & dosificación , Neoplasias Pulmonares/cirugía , Azul de Metileno/administración & dosificación , Nódulos Pulmonares Múltiples/cirugía , Cuidados Preoperatorios/métodos , Nódulo Pulmonar Solitario/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Cirugía Torácica Asistida por Video
20.
Int J Comput Assist Radiol Surg ; 14(10): 1775-1784, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31367806

RESUMEN

PURPOSE: Digital subtraction angiography (DSA) is a powerful technique for diagnosing cardiovascular disease. In order to avoid image artifacts caused by patient movement during imaging, we take deep learning-based methods to generate DSA image from single live image without the mask image. METHODS: Conventional clinical DSA datasets are acquired with a standard injection protocol. More than 600 sequences obtained from more than 100 subjects were used for head and leg experiments. Here, the residual dense block (RDB) is adopted to generate DSA image from single live image directly, and RDBs can extract high-level features by dense connected layers. To obtain better vessel details, a supervised generative adversarial network strategy is also used in the training stage. RESULTS: The human head and leg experiments show that the deep learning methods can generate DSA image from single live image, and our method can do better than other models. Specifically, the DSA image generating with our method contains less artifact and is suitable for diagnosis. We use metrics including PSNR, SSIM and FSIM, which can reach 23.731, 0.877 and 0.8946 on the head dataset and 26.555, 0.870 and 0.9284 on the leg dataset. CONCLUSIONS: The experiment results show the model can extract the vessels from the single live image, thus avoiding the image artifacts obtained by subtracting the live image and the mask image. And our method has a better performance than other methods we have tried on this task.


Asunto(s)
Angiografía de Substracción Digital/métodos , Aprendizaje Profundo , Técnicas de Diagnóstico Cardiovascular , Procesamiento de Imagen Asistido por Computador/métodos , Artefactos , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA