Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Kidney Int ; 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38964736

RESUMEN

The fluorescent compound relmapirazin has been rationally designed for use in point-of-care measurement of glomerular filtration rate (GFR), with attributes including negligible protein binding, negligible metabolites in vivo, negligible tubular secretion, and excellent chemical and photo stability. Twenty-four nonclinical assays were performed in accordance with FDA requirements yielding negligible toxicology concerns. Here, a clinical study was performed to validate relmapirazin as a GFR tracer in patients by comparison to iohexol. This was evaluated in 120 adults at three clinical sites with eGFR values ranging from normal to Stage 4 chronic kidney disease. Relmapirazin and iohexol were administered intravenously in consecutive boluses to each subject and serial blood samples obtained over the subsequent 12 hours. Plasma concentrations were measured and the corresponding plasma GFR for each agent was determined using a standard two-compartment pharmacokinetic assessment. Urine from each subject was collected for the entire 12-hour study period to measure the amount of administered dose appearing in the urine. A near perfect linear regression correlation was observed between the GFRs measured by these two tracers (r2=0.99). Bland-Altman analysis confirmed agreement between these two measures of GFR (limits of agreement -7.0 to +5.6 mL/min; mean of -0.7 mL/min). The GFR determined by relmapirazin was independent of GFR stratification by chronic kidney disease stage, and importantly by race. The percent of the administered relmapirazin dose recovered in the urine was greater than or equal to that of iohexol with no reported severe adverse events. Thus, relmapirazin may be used as a GFR tracer agent in humans.

2.
Gastro Hep Adv ; 3(4): 491-497, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38813093

RESUMEN

Background and Aims: The dual sugar absorption test as a classic measure of human intestinal permeability has limited clinical utility due to lengthy and cumbersome urine collection, assay variability, and long turnaround. We aimed to determine if the orally administered fluorophore MB-102 (relmapirazin) (molecular weight [MW] = 372) compares to lactulose (L) (MW = 342) and rhamnose (R) (MW = 164)-based dual sugar absorption test as a measure of gut permeability in people with a spectrum of permeability including those with Crohn's disease (CD). Methods: We performed a single-center, randomized, open-label, crossover study comparing orally administered MB-102 (1.5 or 3.0 mg/kg) to L (1000 mg) and R (200 mg). Adults with active small bowel CD on magnetic resonance enterography (cases) and healthy adults (controls) were randomized to receive either MB-102 or L and R on study day 1, and the other tracer 3 to 7 days later. Urine was collected at baseline and 1, 2, 4, 6, 8, 10, and 12 hours after tracer ingestion to calculate the cumulative urinary percent excretion of MB-102 and L and R. Results: Nine cases and 10 controls completed the study without serious adverse events. Urinary recovery of administered MB-102 correlated with recovery of lactulose (r-squared = 0.83) for all participants. MB-102 urine recovery was also tracked with the L:R ratio urine recovery (r-squared = 0.57). In controls, the percentages of L and MB-102 recovered were similar within a narrow range, unlike in CD patients. Conclusion: This first-in-human study of an orally administered fluorophore to quantify gastrointestinal permeability in adults with CD demonstrates that MB-102 is well tolerated, and its recovery in urine mirrors that of percent L and the L:R ratio.

3.
ASAIO J ; 69(7): 702-707, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37071749

RESUMEN

MB-102 is a novel fluorescent tracer agent that is exclusively removed from the body by glomerular filtration. This agent can be detected transdermally to provide a real-time measurement of glomerular filtration rate at the point-of-care and is currently in clinical studies for such. MB-102 clearance during continuous renal replacement therapy (CRRT) is unknown. Its plasma protein binding (~0%), molecular weight (~372 Da) and volume of distribution (15-20 L) suggest that it may be removed by renal replacement therapies. To determine the disposition of MB-102 during CRRT, an in vitro study assessing the transmembrane clearance (CL TM ) and adsorptive clearance of MB-102 was conducted. A validated in vitro bovine blood continuous hemofiltration (HF) and continuous hemodialysis (HD) models were performed using two types of hemodiafilters to evaluate CL TM of MB-102. For HF, three different ultrafiltration rates were evaluated. For HD, four different dialysate flow rates were evaluated. Urea was used as a control. No MB-102 adsorption to the CRRT apparatus or either of hemodiafilters was observed. MB-102 is readily removed by HF and HD. Dialysate and ultrafiltrate flow rates directly influence MB-102 CLTM. Hence MB-102 CLTM should be measurable for critically ill patients receiving CRRT.


Asunto(s)
Terapia de Reemplazo Renal Continuo , Hemofiltración , Humanos , Animales , Bovinos , Hemofiltración/métodos , Adsorción , Diálisis Renal/métodos , Terapia de Reemplazo Renal/métodos , Soluciones para Diálisis/química
4.
ASAIO J ; 69(7): 708-715, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37097973

RESUMEN

Critically ill patients undergoing continuous renal replacement therapy (CRRT) have medical conditions requiring extensive pharmacotherapy. Continuous renal replacement therapy impacts drug disposition. Few data exist regarding drug dosing requirements with contemporary CRRT modalities and effluent rates. The practical limitations of pharmacokinetic studies requiring numerous plasma and effluent samples, and lack of generalizability of observations from specific CRRT prescriptions, highlight gaps in bedside assessment of CRRT drug elimination and individualized dosing needs. We employed a porcine model using transdermal fluorescence detection of the glomerular filtration rate fluorescent tracer agent MB-102, with the aim to assess the relationship between systemic exposure of MB-102 and meropenem during CRRT. Animals underwent bilateral nephrectomies and received intravenous bolus doses of MB-102 and meropenem. Once MB-102 equilibrated in the animal, CRRT was initiated. Continuous renal replacement therapy prescriptions comprised four combinations of blood pump (low versus high) and effluent (low versus high) flow rates. Changes in transdermal detected MB-102 clearance occurred immediately with a change in CRRT rates. Blood side meropenem clearance mirrored transdermal MB-102 clearance ( r2 : 0.95-0.97, p value all <0.001). We suggest transdermal MB-102 clearance provides real-time personalized assessment of drug elimination and could optimize prescription of drugs for critically ill patients requiring CRRT.


Asunto(s)
Antibacterianos , Terapia de Reemplazo Renal Continuo , Animales , Porcinos , Meropenem/farmacocinética , Antibacterianos/farmacocinética , Enfermedad Crítica , Terapia de Reemplazo Renal/métodos
5.
Bioorg Med Chem ; 20(8): 2490-7, 2012 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-22459210

RESUMEN

Novel pyrazine carboxamides bearing hydrophilic poly(ethylene glycol) (PEG) moieties were designed, synthesized, and evaluated for use as fluorescent glomerular filtration rate (GFR) tracer agents. Among these, compounds 4d and 5c that contain about 48 ethylene oxide units in the PEG chain exhibited the most favorable physicochemical and renal clearance properties. In vitro studies show that these two compounds have low plasma protein binding, a necessary condition for renal excretion. In vivo animal model results show that 4d and 5c have a higher urine recovery of the injected dose than iothalamate (a commonly considered gold standard GFR agent). Pharmacokinetic studies show that these two compounds exhibit a plasma clearance equivalent to iothalamate, but with a faster (i.e. lower) terminal half-life than iothalamate (possibly from restricted distribution into the extracellular space due to large molecular size and hydrodynamic volume). Furthermore, the plasma clearance of 4d and 5c remained unchanged upon blockage of the tubular secretion pathway with probenecid, a necessary condition for establishment of clearance via glomerular filtration exclusively. Finally, noninvasive real-time monitoring of this class of compounds was demonstrated by pharmacokinetic clearance of 5c by optical measurements in rat model, which correlates strongly with plasma concentration of the tracer. Hence, 4d and 5c are promising candidates for translation to the clinic as exogenous fluorescent tracer agents in real-time point-of-care monitoring of GFR.


Asunto(s)
Colorantes Fluorescentes/química , Tasa de Filtración Glomerular , Sistemas de Atención de Punto , Polietilenglicoles/química , Pirazinas/química , Animales , Colorantes Fluorescentes/análisis , Colorantes Fluorescentes/síntesis química , Masculino , Estructura Molecular , Pirazinas/análisis , Pirazinas/síntesis química , Ratas , Ratas Sprague-Dawley , Estereoisomerismo , Factores de Tiempo
6.
J Pharm Sci ; 109(2): 1191-1198, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31715178

RESUMEN

MB-102 is a fluorescent tracer agent designed for measurement of point-of-care glomerular filtration rate (GFR) and is currently in clinical studies. MB-102 possesses a strong UV absorbance at 266 nm and 435 nm, and broad fluorescent emission at ~560 nm when excited at ~440 nm. The MB-102 formulation is stable at 2°C-8°C for >3 years. The pKa's of the 2 acid groups are 2.71 and 3.40. Both X-ray crystallography and HPLC confirmed the D, D chirality of MB-102 in solid, in solution, and in the drug formulation. Initial safety and toxicity was published previously [Bugaj and Dorshow, 2015], which enabled the commencement of clinical studies. In vitro studies showed that 4.1% of MB-102 is bound to human plasma proteins, compared to 6.0% for the accepted standard GFR agent iohexol. The blood-to-plasma ratio for MB-102 was 0.590, illustrating minimal distribution of MB-102 into red blood cells. The manufacture of MB-102 under good manufacturing practice yields the designed molecular structure at high purity (>95% wt/wt).


Asunto(s)
Yohexol , Sistemas de Atención de Punto , Tasa de Filtración Glomerular , Humanos , Pirazinas
7.
Biomed Opt Express ; 10(10): 5103-5116, 2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31646033

RESUMEN

The intestinal mucosal barrier prevents macromolecules and pathogens from entering the circulatory stream. Tight junctions in this barrier are compromised in inflammatory bowel diseases, environmental enteropathy, and enteric dysfunction. Dual sugar absorption tests are a standard method for measuring gastrointestinal integrity, however, these are not clinically amenable. Herein, we report on a dual fluorophore system and fluorescence detection instrumentation for which gastrointestinal permeability is determined in a rat small bowel disease model from the longitudinal measured transdermal fluorescence of each fluorophore. This fluorophore technology enables a specimen-free, noninvasive, point-of-care gastrointestinal permeability measurement which should be translatable to human clinical studies.

8.
Sci Rep ; 7(1): 10888, 2017 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-28883476

RESUMEN

The healthy gut restricts macromolecular and bacterial movement across tight junctions, while increased intestinal permeability accompanies many intestinal disorders. Dual sugar absorption tests, which measure intestinal permeability in humans, present challenges. Therefore, we asked if enterally administered fluorescent tracers could ascertain mucosal integrity, because transcutaneous measurement of differentially absorbed molecules could enable specimen-free evaluation of permeability. We induced small bowel injury in rats using high- (15 mg/kg), intermediate- (10 mg/kg), and low- (5 mg/kg) dose indomethacin. Then, we compared urinary ratios of enterally administered fluorescent tracers MB-402 and MB-301 to urinary ratios of sugar tracers lactulose and rhamnose. We also tested the ability of transcutaneous sensors to measure the ratios of absorbed fluorophores. Urinary fluorophore and sugar ratios reflect gut injury in an indomethacin dose dependent manner. The fluorophores generated smooth curvilinear ratio trajectories with wide dynamic ranges. The more chaotic sugar ratios had narrower dynamic ranges. Fluorophore ratios measured through the skin distinguished indomethacin-challenged from same day control rats. Enterally administered fluorophores can identify intestinal injury in a rat model. Fluorophore ratios are measureable through the skin, obviating drawbacks of dual sugar absorption tests. Pending validation, this technology should be considered for human use.


Asunto(s)
Colorantes Fluorescentes/administración & dosificación , Colorantes Fluorescentes/análisis , Tracto Gastrointestinal/fisiología , Mucosa Intestinal/fisiología , Permeabilidad/efectos de los fármacos , Coloración y Etiquetado/métodos , Animales , Modelos Animales de Enfermedad , Tracto Gastrointestinal/efectos de los fármacos , Indometacina/administración & dosificación , Indometacina/toxicidad , Enfermedades Intestinales/inducido químicamente , Mucosa Intestinal/efectos de los fármacos , Ratas , Piel/química , Urinálisis , Orina/química
9.
J Med Chem ; 54(14): 5048-58, 2011 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-21667980

RESUMEN

Various hydrophilic pyrazine-bis(carboxamides) derived from 3,5-diamino-pyrazine-2,5-dicarboxylic acid bearing neutral and anionic groups were prepared and evaluated for use as fluorescent glomerular filtration rate (GFR) tracer agents. Among these, the dianionic d-serine pyrazine derivatives 2d and 2j, and the neutral dihydroxypropyl 2h, exhibited favorable physicochemical and clearance properties. In vitro studies show that 2d, 2h, and 2j have low plasma protein binding, a necessary condition for renal excretion. In vivo animal model results show that these three compounds exhibit a plasma clearance equivalent to iothalamate (a commonly considered gold standard GFR agent). In addition, these compounds have a higher urine recovery compared to iothalamate. Finally, the plasma clearance of 2d, 2h, and 2j remained unchanged upon blockage of the tubular secretion pathway with probenecid, a necessary condition for establishment of clearance via glomerular filtration only. Hence, 2d, 2h, and 2j are promising candidates for translation to the clinic as exogenous fluorescent tracer agents in real-time point-of-care monitoring of GFR.


Asunto(s)
Tasa de Filtración Glomerular , Sistemas de Atención de Punto , Pirazinas/síntesis química , Animales , Proteínas Sanguíneas/metabolismo , Colorantes Fluorescentes/síntesis química , Colorantes Fluorescentes/química , Colorantes Fluorescentes/farmacocinética , Masculino , Ratones , Unión Proteica , Pirazinas/química , Pirazinas/farmacocinética , Ratas , Ratas Sprague-Dawley , Relación Estructura-Actividad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA