Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Cardiothorac Vasc Anesth ; 35(9): 2626-2630, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33334649

RESUMEN

OBJECTIVES: Balloon postdilation (BPD) is one strategy for decreasing paravalvular leakage, but its effect on long-term mortality remains unclear. The authors sought to clarify whether BPD influences long-term mortality of patients with transcatheter aortic valve replacement (TAVR). DESIGN: Single-center retrospective study. SETTING: National heart center; single institution. PARTICIPANTS: Participants were patients who underwent TAVR in the authors' hospital from January 2014 to December 2016. A balloon-expandable Sapien XT or Sapien3, or self-expandable CoreValve or Evolute R, was implanted according to the decision of the surgeon considering degree of calcification of the aortic valve. INTERVENTIONS: No interventions. MEASUREMENTS AND MAIN RESULTS: Multivariate Cox regression analysis and inverse probability weighted estimation were performed using a propensity score to examine whether BPD influenced six-year mortality. Ultimately, 180 patients were analyzed. During the follow-up period, with a median of 1104 (interquartile range: 730-1463) days, 41 patients died and cumulative incidence of mortality at six years was 22.8%. Society of Thoracic Surgeons score (odds ratio [OR]: 2.257, 95% CI: 1.213-4.197, p = 0.010)], BPD (OR: 0.306, 95% CI: 0.098-0.953, p = 0.041), and paravalvular regurgitation of at least moderate-to-mild severity after deploying (OR: 5.407, 95% CI: 1.626-17.978, p = 0.006) were significant factors of mortality. CONCLUSIONS: BPD is associated with reduced six-year mortality.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
2.
J Clin Monit Comput ; 33(5): 767-776, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30406422

RESUMEN

To compare the accuracy and trending ability of the cardiac index (CI) measured by FloTrac/Vigileo™ (CIFT) or derived by the Fick equation (CIFick) using E-CAiOVX (enables continuous monitoring of oxygen consumption) with that measured by thermodilution (CITD) in patients with off-pump coronary artery bypass surgery. Twenty-two patients undergoing elective off-pump coronary artery bypass surgery were included. CIFT and CIFick were determined simultaneously at six time-points during off-pump coronary artery bypass surgery. At each time-point, phenylephrine (50 µg) was administered to increase systematic vascular resistance, with CI measured before and after administration (CITD used as reference method). Agreement of each method was evaluated by Bland-Altman analysis, while trending ability was evaluated by four-quadrant plot analysis and polar plot analysis. By Bland-Altman analysis, CIFT and CIFick showed percentage errors of 49.5% and 78.6%, respectively, compared with CITD. Subgroup analysis showed a percentage error between COFT and COTD of 28.9% in patients with a CI ≥ 2.4 L/min/m2, and 78.1% in patients with a CI ≥ 2.4 L/min/m2. The concordance rate of four-quadrant plot analysis was 93.3% for CIFT and 66.7% for CIFick in datasets where CITD ≥ 2.4 L/min/m2 before and after phenylephrine administration were included. CIFT and CIFick had wide limits of agreement with CITD, and were below acceptable limits for tracking phenylephrine-induced CI changes. However, subgroup analysis showed improved accuracy and trending ability of CIFT when only points where CITD ≥ 2.4 L/min/m2 were included, while there was no improvement in CIFick accuracy or trending ability.


Asunto(s)
Gasto Cardíaco , Monitoreo Intraoperatorio/instrumentación , Monitoreo Intraoperatorio/métodos , Adulto , Anciano , Anciano de 80 o más Años , Puente de Arteria Coronaria Off-Pump , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Oxígeno/metabolismo , Consumo de Oxígeno , Fenilefrina/farmacología , Estudios Prospectivos , Arteria Pulmonar , Reproducibilidad de los Resultados , Termodilución , Resistencia Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA