Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Optom Vis Sci ; 97(12): 1099-1104, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33252540

RESUMEN

SIGNIFICANCE: This review summarizes the main factors of refractive error after silicone oil removal combined with cataract surgery.The post-operative refractive results of silicone oil removal combined with cataract surgery are closely related to the patient's future vision quality. This report summarizes the factors that influence the difference between the actual post-operative refractive power and the pre-operatively predicted refractive power after silicone oil removal combined with cataract surgery, including axial length, anterior chamber depth, silicone oil, commonly used tools for measuring intraocular lens power, and intraocular lens power calculation formulas, among others. The aim of the report is to assist clinical and scientific research on the elimination of refractive error after silicone oil removal combined with cataract surgery.


Asunto(s)
Extracción de Catarata/efectos adversos , Errores de Refracción/etiología , Aceites de Silicona , Succión/efectos adversos , Cámara Anterior/patología , Longitud Axial del Ojo/patología , Endotaponamiento , Humanos , Implantación de Lentes Intraoculares , Errores de Refracción/prevención & control , Pruebas de Visión
2.
J Ophthalmol ; 2018: 7389412, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29850211

RESUMEN

The surgical outcomes of macular holes (MHs) have improved greatly in recent years. The closure rate is as high as 90-100%, but the outcomes of some special types of MHs remain unsatisfactory. Internal limiting membrane (ILM) peeling dramatically improves the anatomic success rate, but recent studies have found that it could also cause mechanical and subclinical traumatic changes to the retina. Dyes are widely used, and apart from indocyanine green (ICG), the toxicities of other dyes require further research. Face-down posturing is necessary for MHs larger than 400 µm, and the duration of this posture is determined by the type of tamponade and the case. The ellipsoid zone has been shown to be highly correlated with visual outcome and recovery. New surgical methods include the inverted ILM flap technique and the ILM abrasion technique. However, they require further research to determine their effectiveness.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA