Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Pediatr Diabetes ; 23(3): 324-329, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35001477

RESUMEN

BACKGROUND: Highly variable insulin sensitivity, susceptibility to hypoglycemia and inability to effectively communicate hypoglycemic symptoms pose significant challenges for young children with type 1 diabetes (T1D). Herein, outcomes during clinical MiniMed™ 670G system use were evaluated in children aged 2-6 years with T1D. METHODS: Participants (N = 46, aged 4.6 ± 1.4 years) at seven investigational centers used the MiniMed™ 670G system in Manual Mode during a two-week run-in period followed by Auto Mode during a three-month study phase. Safety events, mean A1C, sensor glucose (SG), and percentage of time spent in (TIR, 70-180 mg/dl), below (TBR, <70 mg/dl) and above (TAR, >180 mg/dl) range were assessed for the run-in and study phase and compared using a paired t-test or Wilcoxon signed-rank test. RESULTS: From run-in to end of study (median 87.1% time in auto mode), mean A1C and SG changed from 8.0 ± 0.9% to 7.5 ± 0.6% (p < 0.001) and from 173 ± 24 to 161 ± 16 mg/dl (p < 0.001), respectively. Overall TIR increased from 55.7 ± 13.4% to 63.8 ± 9.4% (p < 0.001), while TBR and TAR decreased from 3.3 ± 2.5% to 3.2 ± 1.6% (p = 0.996) and 41.0 ± 14.7% to 33.0 ± 9.9% (p < 0.001), respectively. Overnight TBR remained unchanged and TAR was further improved 12:00 am-6:00 am. Throughout the study phase, there were no episodes of severe hypoglycemia or diabetic ketoacidosis (DKA) and no serious adverse device-related events. CONCLUSIONS: At-home MiniMed™ 670G Auto Mode use by young children safely improved glycemic outcomes compared to two-week open-loop Manual Mode use. The improvements are similar to those observed in older children, adolescents and adults with T1D using the same system for the same duration of time.


Asunto(s)
Diabetes Mellitus Tipo 1 , Sistemas de Infusión de Insulina , Glucemia , Automonitorización de la Glucosa Sanguínea , Niño , Preescolar , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Sistemas de Infusión de Insulina/efectos adversos
2.
J Pediatr ; 166(3): 764-6, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25575422

RESUMEN

Typical signs of glucocorticoid excess in children are weight gain and poor linear growth. We describe a 2-year-old boy with a cortisol-secreting adenoma who presented with a dramatic decline in head growth. This case underscores concern of adverse effects of excess glucocorticoid on brain growth in very young children.


Asunto(s)
Adenoma/diagnóstico , Neoplasias de las Glándulas Suprarrenales/diagnóstico , Cabeza/crecimiento & desarrollo , Hidrocortisona/metabolismo , Adenoma/sangre , Neoplasias de las Glándulas Suprarrenales/sangre , Cefalometría , Preescolar , Diagnóstico Diferencial , Humanos , Hidrocortisona/sangre , Masculino
3.
J Pediatr ; 164(3): 655-7, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24367986

RESUMEN

A male infant was diagnosed with partial androgen insensitivity caused by a novel mutation in the androgen receptor. At 3.5 months of age, he received 100 mg of testosterone intramuscularly over the course of 3 months to increase phallic size. He developed pubic hair after 5 months and signs of progressive central precocious puberty when re-examined at 17.5 months, which subsequently was suppressed with depot leuprolide.


Asunto(s)
Síndrome de Resistencia Androgénica/tratamiento farmacológico , Andrógenos/efectos adversos , Pubertad Precoz/inducido químicamente , Testosterona/análogos & derivados , Agresión/efectos de los fármacos , Sustitución de Aminoácidos , Síndrome de Resistencia Androgénica/diagnóstico , Síndrome de Resistencia Androgénica/genética , Andrógenos/administración & dosificación , Preparaciones de Acción Retardada , Exones , Hormona Liberadora de Gonadotropina/agonistas , Hemicigoto , Humanos , Hipospadias/etiología , Recién Nacido , Leuprolida/uso terapéutico , Hormona Luteinizante/sangre , Masculino , Mutación , Pene/anomalías , Receptores Androgénicos/genética , Escroto/anomalías , Testosterona/administración & dosificación , Testosterona/efectos adversos , Testosterona/sangre
4.
Diabetes Technol Ther ; 25(9): 652-658, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37252734

RESUMEN

Background: Safety and significant improvement in overall glycated hemoglobin (A1C) and percentage of time spent in (TIR), below (TBR), and above (TAR) glucose range were demonstrated in the pivotal trial of adolescents and adults using the MiniMed™ advanced hybrid closed-loop (AHCL) system with the adjunctive, calibration-required Guardian™ Sensor 3. The present study evaluated early outcomes of continued access study (CAS) participants who transitioned from the pivotal trial investigational system to the approved MiniMed™ 780G system with the non-adjunctive, calibration-free Guardian™ 4 Sensor (MM780G+G4S). Study data were presented alongside those of real-world MM780G+G4S users from Europe, the Middle East, and Africa. Methods: The CAS participants (N = 109, aged 7-17 years and N = 67, aged >17 years) used the MM780G+G4S for 3 months and data of real-world MM780G+G4S system users (N = 10,204 aged ≤15 years and N = 26,099 aged >15 years) were uploaded from September 22, 2021 to December 02, 2022. At least 10 days of real-world continuous glucose monitoring (CGM) data were required for analyses. Glycemic metrics, delivered insulin and system use/interactions underwent descriptive analyses. Results: Time in AHCL and CGM use were >90% for all groups. AHCL exits averaged 0.1/day and there were few blood glucose measurements (BGMs) (0.8/day-1.0/day). Adults in both cohorts met most consensus recommendations for glycemic targets. Pediatric groups met recommendations for %TIR and %TBR, although not those for mean glucose variability and %TAR, possibly due to low use of recommended glucose target (100 mg/dL) and active insulin time (2 h) settings (28.4% in the CAS cohort and 9.4% in the real-world cohort). The CAS pediatric and adult A1C were 7.2% ± 0.7% and 6.8% ± 0.7%, respectively, and there were no serious adverse events. Conclusions: Early clinical use of the MM780G+G4S was safe and involved minimal BGMs and AHCL exits. Consistent with real-world pediatric and adult use, outcomes were associated with achievement of recommended glycemic targets. Clinical Trial Registration number: NCT03959423.


Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Adolescente , Adulto , Niño , Humanos , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Glucosa , Hemoglobina Glucada , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina
5.
Diabetes Technol Ther ; 25(11): 755-764, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37782145

RESUMEN

Background: During MiniMed™ advanced hybrid closed-loop (AHCL) use by adolescents and adults in the pivotal trial, glycated hemoglobin (A1C) was significantly reduced, time spent in range (TIR) was significantly increased, and there were no episodes of severe hypoglycemia or diabetic ketoacidosis (DKA). The present study investigated the same primary safety and effectiveness endpoints during AHCL use by a younger cohort with type 1 diabetes (T1D). Methods: An intention-to-treat population (N = 160, aged 7-17 years) with T1D was enrolled in a single-arm study at 13 investigational centers. There was a run-in period (∼25 days) using HCL or sensor-augmented pump with/without predictive low-glucose management, followed by a 3-month study period with AHCL activated at two glucose targets (GTs; 100 and 120 mg/dL) for ∼45 days each. The mean ± standard deviation values of A1C, TIR, mean sensor glucose (SG), coefficient of variation (CV) of SG, time at SG ranges, and insulin delivered between run-in and study were analyzed (Wilcoxon signed-rank test or t-test). Results: Compared with baseline, AHCL use was associated with reduced A1C from 7.9 ± 0.9% (N = 160) to 7.4 ± 0.7% (N = 136) (P < 0.001) and overall TIR increased from the run-in 59.4 ± 11.8% to 70.3 ± 6.5% by end of study (P < 0.001), without change in CV, time spent below range (TBR) <70 mg/dL, or TBR <54 mg/dL. Relative to longer active insulin time (AIT) settings (N = 52), an AIT of 2 h (N = 19) with the 100 mg/dL GT increased mean TIR to 73.4%, reduced TBR <70 mg/dL from 3.5% to 2.2%, and reduced time spent above range (TAR) >180 mg/dL from 28.7% to 24.4%. During AHCL use, there was no severe hypoglycemia or DKA. Conclusions: In children and adolescents with T1D, MiniMed AHCL system use was safe, A1C was lower, and TIR was increased. The lowest GT and shortest AIT were associated with the highest TIR and lowest TBR and TAR, all of which met consensus-recommended glycemic targets. ClinicalTrials.gov ID: NCT03959423.


Asunto(s)
Diabetes Mellitus Tipo 1 , Cetoacidosis Diabética , Hipoglucemia , Adolescente , Adulto , Niño , Humanos , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/complicaciones , Cetoacidosis Diabética/etiología , Glucosa , Hemoglobina Glucada , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemia/complicaciones , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Resultado del Tratamiento
6.
J Endocr Soc ; 6(5): bvac031, 2022 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-35350394

RESUMEN

We report a successful pregnancy in a young woman with autosomal dominant hypoparathyroidism type 1 (ADH1) due to an activating mutation of the calcium sensing receptor (CASR) (c.2519C>T; p.Ala840Val) who was treated with recombinant human parathyroid hormone (rhPTH)1-34 delivered via continuous subcutaneous infusion using an OmniPod pump. She experienced no tetany or hospitalizations during the pregnancy. Serum calcium levels ranged from 7.2 to 9.8 mg/dL. Due to mild preeclampsia, her infant was delivered at 37 weeks. There were no physical anomalies. The patient continued pump therapy while nursing her daughter, who was ultimately confirmed to have the same CASR mutation. Breastfeeding appeared to protect the infant from significant hypocalcemia without the need for calcium or calcitriol supplementation until weaning at a year of age. A role for parathyroid hormone-related protein (PTHrP) is suggested.

7.
Diabetes Technol Ther ; 24(3): 178-189, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34694909

RESUMEN

Introduction: This trial assessed safety and effectiveness of an advanced hybrid closed-loop (AHCL) system with automated basal (Auto Basal) and automated bolus correction (Auto Correction) in adolescents and adults with type 1 diabetes (T1D). Materials and Methods: This multicenter single-arm study involved an intent-to-treat population of 157 individuals (39 adolescents aged 14-21 years and 118 adults aged ≥22-75 years) with T1D. Study participants used the MiniMed™ AHCL system during a baseline run-in period in which sensor-augmented pump +/- predictive low glucose management or Auto Basal was enabled for ∼14 days. Thereafter, Auto Basal and Auto Correction were enabled for a study phase (∼90 days), with glucose target set to 100 or 120 mg/dL for ∼45 days, followed by the other target for ∼45 days. Study endpoints included safety events and change in mean A1C, time in range (TIR, 70-180 mg/dL) and time below range (TBR, <70 mg/dL). Run-in and study phase values were compared using Wilcoxon signed-rank test or paired t-test. Results: Overall group time spent in closed loop averaged 94.9% ± 5.4% and involved only 1.2 ± 0.8 exits per week. Compared with run-in, AHCL reduced A1C from 7.5% ± 0.8% to 7.0% ± 0.5% (<0.001, Wilcoxon signed-rank test, n = 155), TIR increased from 68.8% ± 10.5% to 74.5% ± 6.9% (<0.001, Wilcoxon signed-rank test), and TBR reduced from 3.3% ± 2.9% to 2.3% ± 1.7% (<0.001, Wilcoxon signed-rank test). Similar benefits to glycemia were observed for each age group and were more pronounced for the nighttime (12 AM-6 AM). The 100 mg/dL target increased TIR to 75.4% (n = 155), which was further optimized at a lower active insulin time (AIT) setting (i.e., 2 h), without increasing TBR. There were no severe hypoglycemic or diabetic ketoacidosis events during the study phase. Conclusions: These findings show that the MiniMed AHCL system is safe and allows for achievement of recommended glycemic targets in adolescents and adults with T1D. Adjustments in target and AIT settings may further optimize glycemia and improve user experience. Clinical Trial Registration number: NCT03959423.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adolescente , Adulto , Anciano , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Persona de Mediana Edad , Adulto Joven
8.
J Pediatr ; 159(4): 566-70, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21592500

RESUMEN

OBJECTIVE: To determine what percentage of diabetes insipidus (DI) in childhood is idiopathic and to assess the natural history of idiopathic DI. STUDY DESIGN: We conducted a retrospective chart review of 105 patients with DI who were born or had DI diagnosed between 1980-1989 at 3 medical centers. A second cohort of 30 patients from 6 medical centers in whom idiopathic DI was diagnosed after 1990 was evaluated retrospectively for subsequent etiologic diagnoses and additional hypothalamic/pituitary deficiencies and prospectively for quality of life. RESULTS: In the first cohort, 11% of patients had idiopathic DI. In the second cohort, additional hypothalamic/pituitary hormone deficiencies developed in 33%, and 37% received an etiologic diagnosis for DI. Health-related quality of life for all the patients with idiopathic DI was comparable with the healthy reference population. CONCLUSIONS: Only a small percentage of patients with DI will remain idiopathic after first examination. Other hormone deficiencies will develop later in one-third of those patients, and slightly more than one-third of those patients will have an etiology for the DI diagnosed. Long-term surveillance is important because tumors have been diagnosed as long as 21 years after the onset of DI. Quality of life for these patients is as good as the reference population.


Asunto(s)
Diabetes Insípida/etiología , Adolescente , Neoplasias del Sistema Nervioso Central/epidemiología , Niño , Preescolar , Estudios de Cohortes , Diabetes Insípida/diagnóstico , Femenino , Histiocitosis de Células de Langerhans/epidemiología , Humanos , Lactante , Masculino , Hormonas Peptídicas/deficiencia , Estudios Prospectivos , Calidad de Vida , Estudios Retrospectivos , Vasopresinas/genética
9.
Curr Opin Pediatr ; 22(4): 501-7, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20489637

RESUMEN

PURPOSE OF REVIEW: Aromatase inhibitors have been reported to increase height prediction in boys with short stature, and in boys and girls with gonadotropin-independent precocious puberty. The following review discusses data published since 2008 regarding the safety and efficacy of aromatase inhibitors in pediatric patients. RECENT FINDINGS: Third-generation aromatase inhibitors in combination with antiandrogens appear effective in preventing bone age advancement and virilization in boys with familial male-limited precocious puberty (FMPP). Letrozole, but not anastrozole, decreased bleeding episodes and bone age advancement in girls with McCune-Albright syndrome (MAS), despite ovarian enlargement. Letrozole-treated boys with idiopathic short stature (ISS) had no loss of bone density but were noted to have more vertebral abnormalities than a placebo group. Two years of letrozole therapy did not increase predicted adult height in pre and peripubertal boys with ISS when re-assessed 4 years after the treatment period. SUMMARY: Aromatase inhibitors together with an antiandrogen appear to be a very promising treatment for FMPP. Further longer-term studies with letrozole are needed in MAS. The prevalence of vertebral deformities should be evaluated prospectively in patients treated with aromatase inhibitors. Adult height data are still lacking in pediatric patients treated with aromatase inhibitors. Two years of therapy in pre and peripubertal short boys does not appear to increase adult height. Hemogram, lipids, and bone density should be periodically assessed in treated patients. Further controlled studies are needed to demonstrate safety and efficacy of aromatase inhibitors in pediatric patients.


Asunto(s)
Desarrollo del Adolescente/efectos de los fármacos , Inhibidores de la Aromatasa/uso terapéutico , Aromatasa/sangre , Desarrollo Infantil/efectos de los fármacos , Trastornos del Crecimiento/tratamiento farmacológico , Adolescente , Niño , Femenino , Trastornos del Crecimiento/enzimología , Humanos , Masculino , Pronóstico , Pubertad Precoz/enzimología , Pubertad Precoz/prevención & control
10.
Eur J Endocrinol ; 183(6): K13-K21, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33112267

RESUMEN

INTRODUCTION: Gain-of-function mutations in the CASR gene cause Autosomal Dominant Hypocalcemia Type 1 (ADH1), the most common genetic cause of isolated hypoparathyroidism. Subjects have increased calcium sensitivity in the renal tubule, leading to increased urinary calcium excretion, nephrocalcinosis and nephrolithiasis when compared with other causes of hypoparathyroidism. The traditional approach to treatment includes activated vitamin D but this further increases urinary calcium excretion. METHODS: In this case series, we describe the use of recombinant human parathyroid hormone (rhPTH)1-84 to treat subjects with ADH1, with improved control of serum and urinary calcium levels. RESULTS: We describe two children and one adult with ADH1 due to heterozygous CASR mutations who were treated with rhPTH(1-84). Case 1 was a 9.4-year-old female whose 24-h urinary calcium decreased from 7.5 to 3.9 mg/kg at 1 year. Calcitriol and calcium supplementation were discontinued after titration of rhPTH(1-84). Case 2 was a 9.5-year-old male whose 24-h urinary calcium decreased from 11.7 to 1.7 mg/kg at 1 year, and calcitriol was also discontinued. Case 3 was a 24-year-old female whose treatment was switched from multi-dose teriparatide to daily rhPTH(1-84). All three subjects achieved or maintained target serum levels of calcium and normal or improved urinary calcium levels with daily rhPTH(1-84) monotherapy. CONCLUSIONS: We have described three subjects with ADH1 who were treated effectively with rhPTH(1-84). In all cases, hypercalciuria improved by comparison to treatment with conventional therapy consisting of calcium supplementation and calcitriol.


Asunto(s)
Hipoparatiroidismo/tratamiento farmacológico , Hipoparatiroidismo/genética , Hormona Paratiroidea/administración & dosificación , Receptores Sensibles al Calcio/genética , Niño , Femenino , Humanos , Hipoparatiroidismo/diagnóstico , Masculino , Proteínas Recombinantes/administración & dosificación , Resultado del Tratamiento , Adulto Joven
11.
Diabetes Technol Ther ; 21(1): 11-19, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30585770

RESUMEN

OBJECTIVE: To evaluate the safety of in-home use of the MiniMed™ 670G system with SmartGuard™ technology in children with type 1 diabetes (T1D). METHODS: Participants (N = 105, ages 7-13 years, mean age 10.8 ± 1.8 years) were enrolled at nine centers (eight in the United States and one in Israel) and completed a 2-week baseline run-in phase in Manual Mode followed by a 3-month study phase with Auto Mode enabled. Sensor glucose (SG), glycated hemoglobin (HbA1c), percentage of SG values across glucose ranges, and SG variability, during the run-in and study phases were compared. Participants underwent frequent sample testing with i-STAT® venous reference measurement during a hotel period (6 days/5 nights) to evaluate the system's continuous glucose monitoring performance. RESULTS: Auto Mode was used a median of 81% of the time. From baseline to end of study, overall SG dropped by 6.9 ± 17.2 mg/dL (P < 0.001), HbA1c decreased from 7.9% ± 0.8% to 7.5% ± 0.6% (P < 0.001), percentage of time in target glucose range (70-180 mg/dL) increased from 56.2% ± 11.4% to 65.0% ± 7.7% (P < 0.001), and the SG coefficient of variation decreased from 39.6% ± 5.4% to 38.5% ± 3.8% (P = 0.009). The percentage of SG values within target glucose range was 68.2% ± 9.1% and that of i-STAT reference values was 65.6% ± 17.7%. The percentage of values within 20%/20 of the i-STAT reference was 85.2%. There were no episodes of severe hypoglycemia or diabetic ketoacidosis during the study phase. CONCLUSION: In-home use of MiniMed 670G system Auto Mode for 3 months by children with T1D, similar to MiniMed 670G system use by adolescents and adults with T1D, was safe and associated with reduced HbA1c levels and increased time in target glucose range, compared with baseline.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina/estadística & datos numéricos , Insulina/administración & dosificación , Adolescente , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea , Niño , Diabetes Mellitus Tipo 1/sangre , Femenino , Hemoglobina Glucada/análisis , Humanos , Masculino , Resultado del Tratamiento
12.
Diabetes Technol Ther ; 20(11): 731-737, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30299976

RESUMEN

BACKGROUND: The Medtronic predictive low-glucose management (PLGM) algorithm automatically stops insulin delivery when sensor glucose (SG) is predicted to reach or fall below a preset low-glucose value within the next 30 min, and resumes delivery after hypoglycemia recovery. The present study evaluated the PLGM algorithm performance of the MiniMed™ 670G system SmartGuard™ "suspend before low" feature in children aged 7-13 years with type 1 diabetes (T1D). METHOD: Participants (N = 105, mean ± standard deviation of 10.8 ± 1.8 years) underwent an overnight in-clinic evaluation of the "suspend before low" feature with a preset low limit of 65 mg/dL. After exercise, frequent sample testing (FST) was conducted every 5 min if values were <70 mg/dL; every 15 min if 70-80 mg/dL; and every 30 min if >80 mg/dL. First-day performance of the Guardian™ Sensor 3 glucose sensor and continuous glucose monitoring system was also evaluated. RESULTS: Activation of the "suspend before low" feature occurred in 79 of the 105 participants, 79.7% (63/79) did not result in SG falling below 65 mg/dL. Mean glucose at activation was 102 ± 19 mg/dL and the initial insulin suspension duration was 87.5 ± 32.7 min. Four hours after insulin resumption, mean reference glucose was 130 ± 42 mg/dL. Mean absolute relative difference between the FST reference glucose and SG values on the first day of sensor wear was 11.4%. For the 26 participants in whom the "suspend before low" feature did not activate, none involved a reference glucose value ≤65 mg/dL, suggesting that the PLGM algorithm performed as intended. CONCLUSION: In children aged 7-13 years with T1D, the "suspend before low" feature of the MiniMed 670G system demonstrated a hypoglycemia prevention rate of nearly 80% after exercise and did not involve rebound hyperglycemia. There were no events of severe hypoglycemia during the evaluation.


Asunto(s)
Algoritmos , Glucemia/análisis , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemia/prevención & control , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Adolescente , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/métodos , Niño , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/complicaciones , Ejercicio Físico/fisiología , Femenino , Humanos , Hiperglucemia/sangre , Hiperglucemia/etiología , Hiperglucemia/prevención & control , Hipoglucemia/sangre , Hipoglucemia/etiología , Insulina/análisis , Masculino , Valores de Referencia , Factores de Tiempo , Resultado del Tratamiento
13.
J Clin Endocrinol Metab ; 92(11): 4154-60, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17711924

RESUMEN

BACKGROUND: Transdermal (TD) estrogen is often preferred over the oral route in postmenopausal and GH-deficient women taking estrogen, but this has not been studied in detail in girls. OBJECTIVE: Our objective was to study the metabolic effects of oral vs. TD estrogen in GH-treated girls with Turner syndrome. DESIGN AND METHODS: Eleven girls with Turner syndrome, mean age 13.4 +/- 0.5 (se) yr, on GH for at least 6 months were recruited. Studies included [(13)C]leucine and d5-glycerol infusions, indirect calorimetry, dual-emission x-ray absorptiometry, and hormone and substrate measurements. They received, in random order, 17beta-estradiol orally (0.5, 1, and 2 mg for 2 wk each) and TD (0.025, 0.0375, and 0.05 mg for 2 wk each), and studies were repeated after each 6-wk course with 4 wk washout in between. RESULTS: Rates of whole-body protein turnover, oxidation and synthesis, lipolysis, lipid and carbohydrate oxidation, and resting energy expenditure were unaffected by either form of estrogen; nor were lipids, insulin, and fibrinogen concentrations affected. Plasma IGF-I concentrations did not change clinically significantly with either form of estrogen, despite higher estrogen concentrations after oral estrogen. Estradiol concentrations did not correlate with any variables measured. CONCLUSIONS: In GH-treated girls with Turner syndrome, neither oral nor TD estrogen adversely affected rates of protein turnover, lipolysis, and lipid oxidation rates or plasma lipids, fibrinogen, or fasting insulin concentrations. There was no clinically significant change in IGF-I concentrations after either form of estrogen. In aggregate, these data suggest that the route of delivery of estrogen does not adversely affect these metabolic effects of GH in young girls with Turner syndrome.


Asunto(s)
Estrógenos/administración & dosificación , Estrógenos/uso terapéutico , Hormona del Crecimiento/uso terapéutico , Síndrome de Turner/tratamiento farmacológico , Administración Cutánea , Administración Oral , Adolescente , Composición Corporal/efectos de los fármacos , Estatura/efectos de los fármacos , Índice de Masa Corporal , Calorimetría Indirecta , Metabolismo de los Hidratos de Carbono/efectos de los fármacos , Preescolar , Proteínas en la Dieta/metabolismo , Estrógenos/sangre , Femenino , Fibrinógeno/metabolismo , Humanos , Proteína 3 de Unión a Factor de Crecimiento Similar a la Insulina/sangre , Factor I del Crecimiento Similar a la Insulina/metabolismo , Cinética , Metabolismo de los Lípidos/efectos de los fármacos , Peroxidación de Lípido/efectos de los fármacos , Lipólisis/efectos de los fármacos , Oxidación-Reducción , Síndrome de Turner/metabolismo , Síndrome de Turner/patología
14.
J Clin Endocrinol Metab ; 92(5): 1697-704, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17327379

RESUMEN

CONTEXT: GnRH analog (GnRHa) therapy for central precocious puberty (CPP) typically involves im injections. The histrelin implant is a new treatment that provides a continuous slow release of the GnRHa histrelin. OBJECTIVE: The objective of the study was to investigate the safety and efficacy of the subdermal histrelin implant for the treatment of CPP in treatment naive and previously treated children. DESIGN: This was a phase III, open-label, prospective study of 1-yr duration. SETTING: The study was conducted at nine U.S. medical centers. PATIENTS: Girls ages 2-8 yr (naive) or 2-10 yr (previously treated) and boys 2-9 yr (naive) or 2-11 yr (previously treated) with clinical evidence of CPP and a pretreatment pubertal response to leuprolide stimulation were eligible. INTERVENTION: A 50-mg histrelin implant was inserted sc in the inner upper arm. MAIN OUTCOME MEASURES: Peak LH after GnRHa stimulation testing and estradiol (girls) and testosterone (boys) were the main outcome measures. RESULTS: Thirty-six subjects (20 naive) were enrolled. By 1 month, peak LH fell from 28.2 +/- 19.97 (naive) to 0.8 +/- 0.39 mIU/ml (P < 0.0001) and from 2.1 +/- 2.15 (previously treated) to 0.5 +/- 0.32 mIU/ml (P < 0.0056). Estradiol suppressed from 24.5 +/- 22.27 (naive) to 5.9 +/- 2.37 pg/ml (P = 0.0016) and remained suppressed in previously treated subjects, as did testosterone. Suppression was maintained throughout the study. No significant adverse events occurred. CONCLUSIONS: The subdermal histrelin implant achieves and maintains excellent suppression of peak LH and sex steroid levels for 1 yr in children with CPP. The treatment is well tolerated. Long-term studies are needed to confirm these results.


Asunto(s)
Hormona Liberadora de Gonadotropina/análogos & derivados , Pubertad Precoz/tratamiento farmacológico , Determinación de la Edad por el Esqueleto , Índice de Masa Corporal , Huesos/diagnóstico por imagen , Mama/crecimiento & desarrollo , Niño , Preescolar , Implantes de Medicamentos , Estradiol/sangre , Femenino , Hormona Folículo Estimulante/sangre , Hormona Liberadora de Gonadotropina/administración & dosificación , Hormona Liberadora de Gonadotropina/efectos adversos , Hormona Liberadora de Gonadotropina/uso terapéutico , Crecimiento/efectos de los fármacos , Humanos , Hormona Luteinizante/sangre , Masculino , Estudios Prospectivos , Testosterona/sangre
15.
J Clin Endocrinol Metab ; 91(6): 2055-61, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16551733

RESUMEN

CONTEXT: Tumor-induced osteomalacia (TIO) is a paraneoplastic syndrome of hypophosphatemia, decreased renal phosphate reabsorption, normal or low serum 1,25-dihydryxyvitamin-D concentration, myopathy, and osteomalacia. Fibroblast growth factor 23 (FGF23) is a phosphaturic protein overexpressed in tumors that cause TIO and is, at least partly, responsible for the manifestations of TIO. OBJECTIVE: The objective of this study was to determine the sensitivity of FGF23 measurements in TIO. DESIGN: FGF23 concentrations were measured on stored samples with three ELISAs. SETTING: This study was conducted at subspecialty referral centers. PATIENTS: Twenty-two patients with suspected TIO, 13 with confirmed tumors, were studied. INTERVENTIONS: There were no interventions in this study. MAIN OUTCOME MEASURE: FGF23 concentration was the main outcome measure of this study. RESULTS: Elevated FGF23 concentrations were detected using the Immunotopics C-terminal assay in 16 of 22 TIO patients (for a sensitivity of 73%), the Immunotopics Intact assay in five of 22 patients (sensitivity, 23%), and the Kainos Intact assay in 19 of 22 patients (sensitivity, 86%). In the 13 patients with confirmed tumors, the sensitivity was higher with all assays: 92% for the Immunotopics C-terminal assay, 38% for the Immunotopics Intact assay, and 100% for the Kainos assay. CONCLUSION: The Kainos Intact assay was the most sensitive, followed by the Immunotopics C-terminal assay. The findings of normal FGF23 concentrations in some patients with TIO may indicate that FGF 23 is not responsible for the hypophosphatemia in these patients or that FGF23 secretion by some tumors is partially responsive to serum phosphate. Normal FGF23 concentrations should be interpreted in relation to the serum phosphate and 1,25-dihydryxyvitamin-D concentrations.


Asunto(s)
Factores de Crecimiento de Fibroblastos/sangre , Hipofosfatemia/sangre , Osteomalacia/sangre , Síndromes Paraneoplásicos/sangre , Adolescente , Adulto , Anciano , Niño , Femenino , Factor-23 de Crecimiento de Fibroblastos , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
16.
J Med Case Rep ; 10: 25, 2016 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-26839063

RESUMEN

BACKGROUND: Hyperinsulinism-hyperammonemia syndrome is the second most common cause of congenital hyperinsulinism and is easily treated with diazoxide; however, the symptoms in our patient were very difficult to control with typical medical therapy. To the best of our knowledge, neither our patient's mutation, nor a case of hyperinsulinism-hyperammonemia presenting with dysmorphic features and intrauterine growth restriction has previously been reported. CASE PRESENTATION: We describe a 2-year-old Hispanic girl with an unusual presentation of dysmorphic features and intrauterine growth restriction who was later found to have hyperinsulinism-hyperammonemia syndrome. Chromosomal microarray analysis revealed no copy number variants but demonstrated a high density of noncontiguous regions of homozygosity consistent with limited outbreeding. Sequencing of her GLUD1 gene revealed a previously undescribed mutation of cytosine to thymine at position 1519 resulting in an amino acid change of histidine to tyrosine at position 507. Although no functional studies were performed, function prediction tools in combination with our patient's phenotype support the hypothesis that the mutation is deleterious. Despite treatment with a maximum dose of diazoxide (15 mg/kg/day), phenobarbital (8.5 mg/kg/day divided twice daily) and a protein-restricted diet, she has global developmental delay, and continues to have seizures and recurrent episodes of hypoglycemia. CONCLUSIONS: It remains unclear if her clinical presentation can be solely explained by hyperinsulinism-hyperammonemia syndrome or is the result of an undiagnosed recessive disorder related to her homozygosity. It is our hope that clinicians may learn from our patient when formulating treatment plans for refractory cases of hyperinsulinism-hyperammonemia and avoid the morbidities associated with delayed diagnosis and treatment.


Asunto(s)
Anomalías Múltiples/genética , Discapacidades del Desarrollo/genética , Glutamato Deshidrogenasa/genética , Hiperinsulinismo/genética , Hipoglucemia/genética , Preescolar , Femenino , Retardo del Crecimiento Fetal , Homocigoto , Humanos , Hiperinsulinismo/tratamiento farmacológico , Hipoglucemia/tratamiento farmacológico , Mutación , Análisis de Secuencia por Matrices de Oligonucleótidos
17.
J Pediatr Endocrinol Metab ; 18(11): 1045-51, 2005 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16459450

RESUMEN

BACKGROUND: Gender is an important determinant that affects the ultimate dose of growth hormone (GH) used for replacement in adult GH deficiency (GHD). Women require larger doses of GH per body weight to achieve comparable age-adjusted serum IGF-I concentrations than do men. OBJECTIVE: To test whether this is entirely a sex steroid effect or biologically inherent in gender. PATIENTS AND METHODS: We examined growth response to GH (0.25-0.35 mg/kg/week) during the first 2 years of therapy in 147 children (44 girls), and in the first 3 years of therapy in 83 of these children (23 girls). Children were aged 3-8 years at onset of therapy, had peak stimulated GH <10 microg/l, and were reported to be prepubertal during the period of analysis. RESULTS: In the relative absence of sex steroid, there was no gender difference in growth velocity SDS or gain in height SDS during 2 or 3 years of GH therapy. CONCLUSIONS: Inherent gender differences in linear growth response to GH prior to puberty may exist, but are not evident in the first years of GH therapy at this GH dose.


Asunto(s)
Hormona del Crecimiento/administración & dosificación , Factores Sexuales , Índice de Masa Corporal , Niño , Preescolar , Estudios de Cohortes , Femenino , Humanos , Masculino , Estados Unidos
18.
J Clin Endocrinol Metab ; 87(2): 735-41, 2002 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-11836313

RESUMEN

The most common cause of congenital adrenal hyperplasia is steroid 21-hydroxylase deficiency. The molecular genetics of this disease are such that genotyping is a potentially useful tool in its diagnosis. An assay was developed using real-time, quantitative PCR to detect deletions of the steroid 21-hydroxylase gene (CYP21A2). This assay was able to detect heterozygous gene deletions with an alpha error rate of less than 5%, with a power greater than 95%. When combined with allele-specific PCR, genotyping for the nine most common mutations can be completed within hours of blood sampling. This technique was used to study subjects with 21-hydroxylase deficiency in North Florida. Twenty-eight subjects with congenital adrenal hyperplasia, seven first-degree relatives and thirteen normal subjects, were characterized. Of 96 chromosomes, 69 abnormal alleles were identified. Among unrelated abnormal alleles, the frequency of specific mutations was 28% for a gene deletion, 24% for the intron 2 splice mutation, 10% for ile172asn, 8% each for val281leu and the exon 6 cluster, and 6% for gln318x mutations. These frequencies, as well as the genotype/phenotype correlation, were similar to those found in comparable populations. The utility of genotyping in the diagnosis of 21-hydroxylase deficiency is increased by the rapidity of the analysis. With quantitative PCR, the need for more expensive and time consuming Southern blot analysis is reduced and limited to the clarification of certain genotypes. Faster results will allow for more timely initiation of appropriate therapy and limit the exposure of potentially unnecessary therapy.


Asunto(s)
Sistemas de Computación , Reacción en Cadena de la Polimerasa/métodos , Esteroide 21-Hidroxilasa/genética , Conservación de la Sangre , Niño , ADN/sangre , ADN/genética , Femenino , Eliminación de Gen , Genotipo , Humanos , Recién Nacido , Masculino , Fenotipo , Mutación Puntual , Valores de Referencia
19.
J Clin Endocrinol Metab ; 88(9): 4095-9, 2003 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12970269

RESUMEN

Cardiac mass and function were evaluated in 10 children with classical GH deficiency. Echocardiograms were performed at baseline, 3, 6, and 12 months after initiation of recombinant human (rh) GH therapy (0.3 mg/kg.wk). Before treatment, left ventricular (LV) mass indexed to body surface area (BSA) was low or low normal (<50 g/m(2)) in five children compared with reference control data. Height SD score (-3.2 +/- 0.9 vs. -1.8 +/- 1.3 yr; P < 0.01), growth velocity SD score (-2.7 +/- 1.6 vs. 5.8 +/- 3.1; P < 0.01), LV mass (36 +/- 9 vs. 60 +/- 30 g; P < 0.02), LV mass/BSA (51 +/- 12 vs. 72 +/- 11 g/m(2); P < 0.01), LV mass/height (36 +/- 9 vs. 54 +/- 15 g/m; P < 0.02), and LV mass/m(2.7) (36 +/- 12 vs. 45 +/- 8; P < 0.05) increased significantly with rhGH therapy. Pretreatment LV mass/BSA correlated inversely with fold increase in LV mass/BSA over the year (r = -0.83; P < 0.01). Load-dependent indices of diastolic performance were normal at baseline and did not change with rhGH therapy. Percentage increase of mean velocity of circumferential shortening, an index of systolic function, correlated with fold increase in LV mass/BSA (r = 0.88; P < 0.02) over the year of rhGH administration. LV mass can be lower than predicted for body size in some children with severe GH deficiency but is responsive to rhGH replacement. LV mass/BSA increases into the normal range during the first year of rhGH therapy. The rate of increase of LV mass is greater than the increase in BSA during rhGH treatment, suggesting that GH could also be a trophic factor for the heart.


Asunto(s)
Hormona del Crecimiento/uso terapéutico , Corazón/crecimiento & desarrollo , Hormona de Crecimiento Humana/deficiencia , Presión Sanguínea/efectos de los fármacos , Estatura , Superficie Corporal , Niño , Preescolar , Ecocardiografía , Femenino , Hormona del Crecimiento/efectos adversos , Corazón/anatomía & histología , Corazón/fisiología , Pruebas de Función Cardíaca , Humanos , Masculino , Tamaño de los Órganos/fisiología , Función Ventricular Izquierda/efectos de los fármacos
20.
Case Rep Pediatr ; 2014: 163848, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24592349

RESUMEN

Primary hyperparathyroidism is a very rare complication following radioactive iodine therapy. There is typically a latency period of more than a decade following radiation exposure and, therefore, it is observed almost exclusively in adults. Consequently, pediatricians are not aware of the association. We present a case of primary hyperparathyroidism due to a solitary parathyroid adenoma occurring in an adolescent male two years following radioactive iodine treatment for papillary thyroid carcinoma. Periodic screening of serum calcium following ablative doses of radioactive iodine for thyroid cancer may be justified even in adolescents.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA