Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 98(6): E963-E967, 2021 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-34156744

RESUMEN

Acute ischemic stroke is a feared complication during cardiovascular procedures associated with high morbidity and mortality if not immediately recognized and treated. We conducted a review of cases at our center where patients experienced an acute, procedure-related ischemic stroke and underwent immediate endovascular stroke treatment by the interventional cardiologists trained in acute endovascular stroke intervention. Baseline demographics, procedural and follow-up data were collected. Three patients were identified in whom the percutaneous procedure (peripheral arterial intervention, transapical NeoChord [NeoChord Inc, Minnesota, USA] implantation and transcatheter aortic valve implantation, respectively) was complicated by an acute embolic ischemic stroke. In all cases, cerebral vessel re-canalization was technically successful with thrombolysis in cerebral infarction (TICI) IIB/III flow. Follow-up computed tomography scans showed no infarct demarcation, oedema or intracranial hemorrhage. One patient survived with no neurological symptoms at 6-month follow-up whereas the two other patients died of unrelated intensive care complications and decompensated heart failure. We conclude that endovascular stroke treatment during cardiovascular interventions can be performed by interventional cardiologists with appropriate training. It offers the unique opportunity to treat cerebral embolization in a time-efficient manner, potentially improving morbidity and mortality of affected patients.


Asunto(s)
Isquemia Encefálica , Cardiólogos , Procedimientos Endovasculares , Accidente Cerebrovascular , Procedimientos Endovasculares/efectos adversos , Humanos , Accidente Cerebrovascular/etiología , Trombectomía , Resultado del Tratamiento
2.
Circ Res ; 124(8): 1228-1239, 2019 04 12.
Artículo en Inglés | MEDLINE | ID: mdl-30732532

RESUMEN

RATIONALE: Subcellular Ca2+ indicators have yet to be developed for the myofilament where disease mutation or small molecules may alter contractility through myofilament Ca2+ sensitivity. Here, we develop and characterize genetically encoded Ca2+ indicators restricted to the myofilament to directly visualize Ca2+ changes in the sarcomere. OBJECTIVE: To produce and validate myofilament-restricted Ca2+ imaging probes in an adenoviral transduction adult cardiomyocyte model using drugs that alter myofilament function (MYK-461, omecamtiv mecarbil, and levosimendan) or following cotransduction of 2 established hypertrophic cardiomyopathy disease-causing mutants (cTnT [Troponin T] R92Q and cTnI [Troponin I] R145G) that alter myofilament Ca2+ handling. METHODS AND RESULTS: When expressed in adult ventricular cardiomyocytes RGECO-TnT (Troponin T)/TnI (Troponin I) sensors localize correctly to the sarcomere without contractile impairment. Both sensors report cyclical changes in fluorescence in paced cardiomyocytes with reduced Ca2+ on and increased Ca2+ off rates compared with unconjugated RGECO. RGECO-TnT/TnI revealed changes to localized Ca2+ handling conferred by MYK-461 and levosimendan, including an increase in Ca2+ binding rates with both levosimendan and MYK-461 not detected by an unrestricted protein sensor. Coadenoviral transduction of RGECO-TnT/TnI with hypertrophic cardiomyopathy causing thin filament mutants showed that the mutations increase myofilament [Ca2+] in systole, lengthen time to peak systolic [Ca2+], and delay [Ca2+] release. This contrasts with the effect of the same mutations on cytoplasmic Ca2+, when measured using unrestricted RGECO where changes to peak systolic Ca2+ are inconsistent between the 2 mutations. These data contrast with previous findings using chemical dyes that show no alteration of [Ca2+] transient amplitude or time to peak Ca2+. CONCLUSIONS: RGECO-TnT/TnI are functionally equivalent. They visualize Ca2+ within the myofilament and reveal unrecognized aspects of small molecule and disease-associated mutations in living cells.


Asunto(s)
Calcio/metabolismo , Cardiomiopatía Hipertrófica/genética , Mutación , Miocitos Cardíacos/metabolismo , Miofibrillas/metabolismo , Sarcómeros/metabolismo , Adenosina Trifosfatasas/antagonistas & inhibidores , Adenosina Trifosfatasas/metabolismo , Adenoviridae , Animales , Bencilaminas/farmacología , Cardiomiopatía Hipertrófica/metabolismo , Cobayas , Técnicas In Vitro , Masculino , Miofibrillas/efectos de los fármacos , Miosinas/efectos de los fármacos , Miosinas/metabolismo , Simendán/farmacología , Transducción Genética/métodos , Troponina I/genética , Troponina I/metabolismo , Troponina T/genética , Troponina T/metabolismo , Uracilo/análogos & derivados , Uracilo/farmacología , Urea/análogos & derivados , Urea/farmacología
3.
Europace ; 22(7): 1036-1043, 2020 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32464648

RESUMEN

AIMS: Evidence regarding post-procedural antithrombotic regimen other than used in randomized trials assessing percutaneous left atrial appendage (LAA) closure is limited. The present work aimed to compare different antithrombotic strategies applied in the real-world EWOLUTION study. METHODS AND RESULTS: A total of 998 patients with successful WATCHMAN implantation were available for the present analysis. The composite ischaemic endpoint of stroke, transitory ischaemic attack, systemic embolism and device thrombus, and the bleeding endpoint defined as at least major bleeding were assessed during an initial period (from implant until first medication change) and long-term period (from first change up to 2 years). The antithrombotic medication chosen in the initial phase was dual antiplatelet therapy (DAPT) in 60%, oral anticoagulation (OAC) in 27%, single antiplatelet therapy (SAPT) in 7%, and no medication in 6%. In the second long-term phase, SAPT was used in 65%, DAPT in 23%, no therapy in 8%, and OAC in 4%. No significant differences were found between the groups regarding the ischaemic endpoint both in the initial period (Kaplan-Meier estimated rate 2.9% for DAPT vs. 4.3% for OAC vs. 3.9% for SAPT or no therapy) and in the second period (4.2% for SAPT vs. 1.8% for DAPT vs. 3.5% for no therapy). With respect to bleeding events, the only difference was found in the initial phase with a higher incidence in patients under SAPT or no therapy. CONCLUSIONS: Tailored antithrombotic treatment using even very reduced strategies such as SAPT or no therapy showed no significant differences regarding ischaemic complications after LAA closure.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Fibrinolíticos , Anticoagulantes/uso terapéutico , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrinolíticos/uso terapéutico , Humanos , Resultado del Tratamiento
4.
Curr Hypertens Rep ; 20(3): 18, 2018 03 19.
Artículo en Inglés | MEDLINE | ID: mdl-29556742

RESUMEN

PURPOSE OF REVIEW: Provision of a summary on the physiologic effects of arteriovenous fistula creation and description of previously published human data on the efficacy of a percutaneously implanted device creating an arteriovenous fistula. Though antihypertensive therapy is effective, some patient's blood pressure remains poorly controlled despite adherence to optimal medical therapy. Moreover, some patients are not compliant with recommended medical therapy due to side effects or personal decision. This has prompted exploration of alternative, device-based antihypertensive therapies including, among others, the percutaneous creation of an arteriovenous fistula. An arteriovenous fistula is accompanied by a number of favorable physiologic changes that may lower blood pressure. These physiologic changes, conduction of the procedure, and previously published human experience are summarized in this review article. RECENT FINDINGS: The results of a recently published trial comparing arteriovenous fistula creation and standard antihypertensive therapy versus standard antihypertensive therapy alone are summarized. Creation of an arteriovenous fistula is accompanied by a significant blood pressure reduction likely related to a reduction in total arterial resistance, perhaps blood volume reduction, inhibition of the baroreceptor reflex, and release of natriuretic peptides. These findings foster further interest in studying the impact of an arteriovenous fistula and arterial blood pressure. The design of a large randomized trial comparing arteriovenous fistula creation to sham control is outlined.


Asunto(s)
Antihipertensivos/uso terapéutico , Derivación Arteriovenosa Quirúrgica/métodos , Hipertensión/cirugía , Derivación Arteriovenosa Quirúrgica/efectos adversos , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea , Hemodinámica/fisiología , Humanos , Hipertensión/tratamiento farmacológico , Arteria Ilíaca/cirugía
5.
Curr Hypertens Rep ; 20(3): 27, 2018 04 09.
Artículo en Inglés | MEDLINE | ID: mdl-29629502

RESUMEN

In the March 2018 issue of Current Hypertension Reports, the second author's name Nathan A. Sobotka was inadvertently left out of the byline. Also, the author names were changed from initials to spelled out. The corrected author list is given above. The original article has been corrected.

6.
Card Electrophysiol Clin ; 15(2): 193-200, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37076231

RESUMEN

Left atrial appendage closure aims to eliminate the stasis component of Virchow triad by eliminating a cul-de-sac that favors thrombosis, particularly when atrial contractility becomes inefficient, such as in atrial fibrillation. Left atrial appendage closure devices have a common objective of sealing the appendage completely, with device stability and avoidance of device thrombosis. Two main device designs have been used to perform left atrial appendage closure: those that use a pacifier design (lobe + disk) and those that use a plug (single lobe) design. This review highlights the potential features and benefits of the single-lobe devices.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Trombosis , Humanos , Estudios de Seguimiento , Resultado del Tratamiento , Ecocardiografía Transesofágica , Fibrilación Atrial/cirugía , Trombosis/prevención & control , Cateterismo Cardíaco
7.
Postepy Kardiol Interwencyjnej ; 19(1): 6-13, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37090217

RESUMEN

Introduction: Today, endovascular treatment (EVT) is the therapy of choice for strokes due to acute large vessel occlusion, irrespective of prior thrombolysis. This necessitates fast, coordinated multi-specialty collaboration. Currently, in most countries, the number of physicians and centres with expertise in EVT is limited. Thus, only a small proportion of eligible patients receive this potentially life-saving therapy, often after significant delays. Hence, there is an unmet need to train a sufficient number of physicians and centres in acute stroke intervention in order to allow widespread and timely access to EVT. Aim: To provide multi-specialty training guidelines for competency, accreditation and certification of centres and physicians in EVT for acute large vessel occlusion strokes. Material and methods: The World Federation for Interventional Stroke Treatment (WIST) consists of experts in the field of endovascular stroke treatment. This interdisciplinary working group developed competency - rather than time-based - guidelines for operator training, taking into consideration trainees' previous skillsets and experience. Existing training concepts from mostly single specialty organizations were analysed and incorporated. Results: The WIST establishes an individualized approach to acquiring clinical knowledge and procedural skills to meet the competency requirements for certification of interventionalists of various disciplines and stroke centres in EVT. WIST guidelines encourage acquisition of skills using innovative training methods such as structured supervised high-fidelity simulation and procedural performance on human perfused cadaveric models. Conclusions: WIST multispecialty guidelines outline competency and quality standards for physicians and centres to perform safe and effective EVT. The role of quality control and quality assurance is highlighted.

8.
Cardiovasc Revasc Med ; 53: 67-72, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37012107

RESUMEN

INTRODUCTION: Today, endovascular treatment (EVT) is the therapy of choice for strokes due to acute large vessel occlusion, irrespective of prior thrombolysis. This necessitates fast, coordinated multi-specialty collaboration. Currently, in most countries, the number of physicians and centres with expertise in EVT is limited. Thus, only a small proportion of eligible patients receive this potentially life-saving therapy, often after significant delays. Hence, there is an unmet need to train a sufficient number of physicians and centres in acute stroke intervention in order to allow widespread and timely access to EVT. AIM: To provide multi-specialty training guidelines for competency, accreditation and certification of centres and physicians in EVT for acute large vessel occlusion strokes. MATERIAL AND METHODS: The World Federation for Interventional Stroke Treatment (WIST) consists of experts in the field of endovascular stroke treatment. This interdisciplinary working group developed competency - rather than time-based - guidelines for operator training, taking into consideration trainees' previous skillsets and experience. Existing training concepts from mostly single specialty organizations were analysed and incorporated. RESULTS: The WIST establishes an individualized approach to acquiring clinical knowledge and procedural skills to meet the competency requirements for certification of interventionalists of various disciplines and stroke centres in EVT. WIST guidelines encourage acquisition of skills using innovative training methods such as structured supervised high-fidelity simulation and procedural performance on human perfused cadaveric models. CONCLUSIONS: WIST multispecialty guidelines outline competency and quality standards for physicians and centres to perform safe and effective EVT. The role of quality control and quality assurance is highlighted. SUMMARY: The World Federation for Interventional Stroke Treatment (WIST) establishes an individualized approach to acquiring clinical knowledge and procedural skills to meet the competency requirements for certification of interventionalists of various disciplines and stroke centres in endovascular treatment (EVT). WIST guidelines encourage acquisition of skills using innovative training methods such as structured supervised high-fidelity simulation and procedural performance on human perfused cadaveric models. WIST multispecialty guidelines outline competency and quality standards for physicians and centers to perform safe and effective EVT. The role of quality control and quality assurance is highlighted. SIMULTANEOUS PUBLICATION: The WIST 2023 Guidelines are published simultaneously in Europe (Adv Interv Cardiol 2023).


Asunto(s)
Procedimientos Endovasculares , Accidente Cerebrovascular , Humanos , Trombectomía/métodos , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/terapia , Terapia Trombolítica/métodos , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Cadáver
9.
Interv Cardiol Clin ; 11(2): 195-203, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35361464

RESUMEN

Left atrial appendage closure aims to eliminate the stasis component of Virchow triad by eliminating a cul-de-sac that favors thrombosis, particularly when atrial contractility becomes inefficient, such as in atrial fibrillation. Left atrial appendage closure devices have a common objective of sealing the appendage completely, with device stability and avoidance of device thrombosis. Two main device designs have been used to perform left atrial appendage closure: those that use a pacifier design (lobe + disk) and those that use a plug (single lobe) design. This review highlights the potential features and benefits of the single-lobe devices.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Dispositivo Oclusor Septal , Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Atrios Cardíacos , Humanos
10.
Struct Heart ; 6(5): 100086, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37288061

RESUMEN

Background: Endovascular baroreflex amplification with the MobiusHD, a self-expanding stent-like device that is implanted in the internal carotid artery, was designed to reduce the sympathetic overactivity that contributes to progressive heart failure with reduced ejection fraction. Methods: Symptomatic patients (New York Heart Association class III) with heart failure with reduced ejection fraction (left ventricular ejection fraction [LVEF] ≤40%) despite guideline directed medical therapy and n-terminal pro-B type natriuretic peptide (NT-proBNP) levels ≥400 pg/mL in whom carotid ultrasound and computed tomographic angiography demonstrated absence of carotid plaque were enrolled. Baseline and follow-up measures included 6-minute walk distance (6MWD), Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ OSS), and repeat biomarkers and transthoracic echocardiography. Results: Twenty-nine patients underwent device implantation. The mean age was 60.6 ± 11.4 years, and all had New York Heart Association class III symptoms. Mean KCCQ OSS was 41.4 ± 12.7, mean 6MWD was 216.0 ± 43.7 m, median NT-proBNP was 1005.9 pg/mL (894, 1294), and mean LVEF was 34.7 ± 2.9%. All device implantations were successful. Two patients died (161 days and 195 days) and one stroke occurred (170 days) during follow-up. For the 17 patients with 12-month follow-up, mean KCCQ OSS improved by 17.4 ± 9.1 points, mean 6MWD increased by 97.6 ± 51.1 meters, a mean 28.4% reduction from the baseline NT-proBNP concentration was found, and mean LVEF improved by 5.6% ± 2.9 (paired data). Conclusion: Endovascular baroreflex amplification with the MobiusHD device was safe and effected positive changes in quality of life, exercise capacity, and LVEF, consistent with observed reductions in NT-proBNP levels.

11.
Cardiovasc Revasc Med ; 42: 28-33, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35443925

RESUMEN

OBJECTIVE: To examine the outcomes of percutaneous closure of large atrial septal defects (ASDs) (≥25 mm). BACKGROUND: Data on long-term results after closure of large ASDs are limited. METHODS: We reviewed the records of 275 consecutive patients who underwent transcatheter closure of large (≥25 mm) ASDs from January 1999 until December 2016 in our center. The most common indication for closure was a large left-to-right shunt. Follow-up (FU) was performed at regular intervals thereafter. Results after closure of ASDs with diameters of 25-30 mm, >30-35 mm and >35 mm were compared. RESULTS: Percutaneous closure was technically successful in 99.6%. Mean FU time was 4.8 years (0-15.5 years). Peri-operative (30-day) adverse events occurred in 20.4% and included death in 0.7% (one unrelated to the procedure and one of unknown cause), device erosion in 0.7%, device embolization in 2.9%, pericardial effusion in 5.5%, air embolism in 0.4%, new onset atrial fibrillation in 10.5%, transient supraventricular tachycardia in 0.4% and fever in 0.7%. Late (>30 days after the procedure) atrial fibrillation occurred in 5.8%. There was one device erosion >15 years after the implantation treated successfully surgically. Complete defect closure was achieved in 95.6%. CONCLUSION: Device closure of large ASDs is feasible, safe and effective with high technical success and low risk of serious periprocedural complications. Nevertheless, in very large defects (>40 mm), both options, surgery and percutaneous closure should be considered. Device or procedural long-term adverse events are rare.


Asunto(s)
Fibrilación Atrial , Defectos del Tabique Interatrial , Dispositivo Oclusor Septal , Adulto , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Estudios de Seguimiento , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/terapia , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
12.
JACC Heart Fail ; 10(10): 744-752, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36175060

RESUMEN

BACKGROUND: Ablation of the right-sided greater splanchnic nerve (GSN) can reduce excessive splanchnic vasoconstriction, potentially improving the handling of volume shifts in patients with heart failure with preserved ejection fraction (HFpEF). OBJECTIVES: The purpose of this study was to assess a novel catheter procedure of right-sided GSN ablation to treat HFpEF: splanchnic ablation for volume management. METHODS: This trial included 11 HFpEF patients (8 women, age 70 ± 8 years) with New York Heart Association functional class II or III symptoms, ejection fraction ≥50%, and elevated pulmonary capillary wedge pressure at rest or with exercise. After splanchnic ablation for volume management, follow-up at 1, 3, 6, and 12 months included 6-minute walk test, Kansas City Cardiomyopathy Questionnaire (KCCQ), and echocardiography. RESULTS: There were no device-related adverse cardiac events or clinical sequelae following right GSN ablation through 12 months. Patients experienced clinical improvements by 1 month that were sustained through 12 months. KCCQ score improved from baseline median 48 (IQR: 35-52) to 65 (IQR: 58-77) at 1 month and 80 (IQR: 77-88) at 12 months (P < 0.05). The 6-minute walk test distance increased from baseline 292 ± 82 m to 341 ± 88 m at 1 month and 359 ± 75 m at 12 months (P < 0.05). The NT-proBNP decreased from a baseline mean of 1,292 ± 1,186 pg/mL to 1,202 ± 797 pg/mL (P = 0.585) at 1 month, to 472 ± 226 pg/mL (P = 0.028) at 6 months, and to 379 ± 165 pg/mL (P = 0.039) at 12 months. CONCLUSIONS: In this open-label, single-arm feasibility study, right-sided GSN ablation was safe and improved mostly subjective clinical metrics in patients with HFpEF over 12 months. (Endovascular GSN Ablation in Subjects With HFpEF; NCT04287946).


Asunto(s)
Insuficiencia Cardíaca , Nervios Esplácnicos , Anciano , Estudios de Factibilidad , Femenino , Insuficiencia Cardíaca/cirugía , Humanos , Persona de Mediana Edad , Presión Esfenoidal Pulmonar , Volumen Sistólico , Prueba de Paso
13.
Dtsch Med Wochenschr ; 146(9): 613-617, 2021 04.
Artículo en Alemán | MEDLINE | ID: mdl-33931840

RESUMEN

Thrombus formation due to atrial fibrillation is the most common cause of embolic stroke. Anticoagulation offers an effective prophylaxis. However, anticoagulation in turn has an inherent increased risk of bleeding. Patients with non-valvular atrial fibrillation who have contraindications for anticoagulation may profit from a closure of the left atrial appendage. The most commonly and best studied devices for this are the WATCHMAN™ and the AMPLATZER Amulet™ Occluders.In this How-To article, the aim is to offer a general overview of the indications, contraindications and complications as well as the implantation and postoperative management of patients receiving LAA closure by example of the WATCHMAN FLX™ Occluder.


Asunto(s)
Apéndice Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos , Dispositivo Oclusor Septal/efectos adversos , Fibrilación Atrial/complicaciones , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/instrumentación , Procedimientos Quirúrgicos Cardíacos/métodos , Humanos , Trombosis/etiología , Trombosis/prevención & control
14.
Cardiovasc Revasc Med ; 28S: 158-160, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-32888838

RESUMEN

Stroke remains an important risk during transcatheter aortic valve implantation (TAVI). Though the use of the double-filter Sentinel cerebral protection system (Boston Scientific, Marlborough, MA, USA) may lower the stroke risk, the deployment of this device requires manipulation within the aortic arch and cranial arch vessels potentially causing dislodgment of atherosclerotic debris in the process thereby possibly offsetting its benefit with regards to reducing cerebral embolization. Apart from patient selection, minimizing maneuvering during deployment may improve the safety of device deployment. In this context, we illustrate a case using three-dimensional computed tomography (CT) - overlay to facilitate Sentinel cerebral protection system deployment during TAVI. Emphasis in this case rests on demonstration of how aforementioned periprocedural imaging may facilitate negotiation of anatomical variants and avoid inadvertent cannulation of an anomalous left vertebral artery originating from the aortic arch. Imaging guidance with this concept may minimize device manipulation and reduce the risk of cerebral embolization. Further systematic evaluation is needed to demonstrate whether this approach improves clinical outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Embolia Intracraneal , Reemplazo de la Válvula Aórtica Transcatéter , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Embolia Intracraneal/diagnóstico por imagen , Embolia Intracraneal/etiología , Embolia Intracraneal/prevención & control , Imagen Multimodal , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Arteria Vertebral/diagnóstico por imagen , Arteria Vertebral/cirugía
15.
Cardiovasc Revasc Med ; 30: 72-75, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33097460

RESUMEN

BACKGROUND: A patent foramen ovale (PFO) has been associated with embolic strokes and transient ischemic attacks (TIAs). Catheter closure of PFO is effective in preventing recurrent events. Residual shunts and procedure or device related complications can occur, including atrial fibrillation and thrombus formation. This study examines the initial experience with a new PFO closure device, the IrisFIT PFO-Occluder (Lifetech Scientific, Shenzhen, China). METHODS: 95 patients with indications for PFO closure underwent percutaneous closure with the IrisFIT PFO-Occluder. The primary endpoint was the rate of accurate device placement with no/small residual shunt at 3 or 6 months follow-up. All patients underwent transoesophageal echocardiography (TEE) after 1 to 6 months. In case of a residual shunt, an additional TEE was performed after 12 months. Clinical follow-up was performed up to a mean of 33.1 ± 3.6 months. RESULTS: The device was successfully implanted in 95 (100%) patients with no relevant procedural complications. At final TEE follow-up (7.6 ± 3.9 months) the effective closure rate was 96.8% with 1 moderate and 2 large residual shunts. There were 8 cases of new onset atrial fibrillation and 2 TIAs. There were no cases of device embolization or erosion. CONCLUSION: The IrisFIT occluder is a new PFO closure device with several advantages compared to other devices. In this small study cohort, technical success rate, closure rate and adverse event rate were comparable to other devices. The rate of new onset atrial fibrillation was higher in comparison to other studies and warrants further investigation.


Asunto(s)
Foramen Oval Permeable , Ataque Isquémico Transitorio , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Cateterismo Cardíaco/efectos adversos , Estudios de Seguimiento , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/diagnóstico por imagen , Foramen Oval Permeable/cirugía , Humanos , Ataque Isquémico Transitorio/etiología , Ataque Isquémico Transitorio/prevención & control , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
16.
Cardiovasc Revasc Med ; 24: 77-86, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32958438

RESUMEN

Renal sympathetic denervation using conventional non-irrigated radiofrequency catheters has potential technical shortcomings, including limited penetration depth and incomplete circumferential nerve damage, potentially impacting therapeutic efficacy. Against this background, second generation multi-electrode, radiofrequency and ultrasound renal denervation systems have been developed to provide more consistent circumferential nerve ablation. Irrigated catheters may allow deeper penetration while minimizing arterial injury. In this context, catheter-based chemical denervation, with selective infusion of alcohol, a potent neurolytic agent, into the perivascular space, may minimize endothelial, intimal and medial injury while providing circumferential neurolysis. Animal studies demonstrate pronounced renal norepinephrine level reductions and consistent renal nerve injury after perivascular alcohol infusion using the Peregrine Catheter. Early clinical studies demonstrated significant blood pressure reductions and a reasonable safety profile. Randomized sham-controlled trials (NCT03503773, NCT02910414) are underway to examine whether the aforementioned theoretical advantages of alcohol-medicated denervation with the Peregrine System™ Kit translate into clinical benefits.


Asunto(s)
Ablación por Catéter , Hipertensión , Animales , Antihipertensivos/uso terapéutico , Presión Sanguínea , Ablación por Catéter/efectos adversos , Catéteres , Hipertensión/cirugía , Riñón/cirugía , Arteria Renal/diagnóstico por imagen , Arteria Renal/cirugía , Simpatectomía
17.
EuroIntervention ; 17(12): e1033-e1040, 2021 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-34219662

RESUMEN

BACKGROUND: Residual peri-device leakage (PDL) is frequent after left atrial appendage occlusion (LAAO). Little is known about management strategies, procedural aspects and outcomes of interventional PDL closure. AIMS: The aim of this study was to assess the safety and feasibility of PDL closure after LAAO. METHODS: Fifteen centres contributed data on baseline characteristics, in-hospital and follow-up outcomes of patients who underwent PDL closure after LAAO. Outcomes of interest included acute success and complication rates and long-term efficacy of the procedure. RESULTS: A total of 95 patients were included and a cumulative number of 104 leaks were closed. The majority of PDLs were detected within 90 days (range 41-231). Detachable coils were the most frequent approach (42.3%), followed by the use of the AMPLATZER Vascular Plug II (29.8%) and the AMPLATZER Duct Occluder II (17.3%). Technical success was 100% with 94.2% of devices placed successfully within the first attempt. There were no major complications requiring surgical or transcatheter interventions. During follow-up (96 days [range 49-526]), persistent leaks were found in 18 patients (18.9%), yielding a functional success rate of 82.7%, although PDLs were significantly reduced in size (pre-leak sizemax: 6.1±3.6 mm vs post-leak sizemax: 2.5±1.3 mm, p<0.001). None of the patients had a leak >5 mm. Major adverse events during follow-up occurred in 5 patients (2 ischaemic strokes, 2 intracranial haemorrhages, and 1 major gastrointestinal bleeding). CONCLUSIONS: Several interventional techniques have become available to achieve PDL closure. They are associated with high technical and functional success and low complication rates.


Asunto(s)
Dispositivo Oclusor Septal , Estudios de Factibilidad , Humanos , Dispositivo Oclusor Septal/efectos adversos
18.
Cardiovasc Revasc Med ; 21(11S): 54-59, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32771400

RESUMEN

Transcatheter mitral valve-in-ring implantation (TMViR) poses unique challenges when compared to valve-in-valve implantation due to the large variation in the different annuloplasty rings used. Annuloplasty rings are often classified according to whether they are complete or incomplete, rigid, semi-rigid, or flexible, and whether their three-dimensional geometry is saddle-shaped or flat. A limited number of annuloplasty rings are available which are adjustable allowing the surgeon to increase or decrease the size of the ring once it has been sutured in place. To our knowledge there has been no description of TMViR in such adjustable complete rings and recommendations on THV sizing and implantation are not available on the Valve-in-Valve application. Here we report a case of TMViR in an adjustable annuloplasty ring (Attune ring, Abbott, Chicago, IL, USA) and review the literature on TMViR.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral , Chicago , Humanos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Diseño de Prótesis
19.
Cardiovasc Revasc Med ; 21(6): 726-729, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32171678

RESUMEN

BACKGROUND: Outcomes after transcatheter aortic valve implantation (TAVI) have been demonstrated to be at least equivalent in the short term compared to surgical valve implantation (SAVI). However, Conduction abnormalities are more common after TAVI than SAVI and the need for permanent pacemaker implantation is more common after TAVI with the currently commercially available self-expanding valves than after SAVI. Temporary pacemaker implantation may be associated with inability to ambulate, lead migration or perforation and infection. Depending on the monitoring system, some arrhythmias may not be detected. We examined the feasibility and safety of permanent pacemaker lead implantation connected to an external generator in patients undergoing TAVI at our institution. METHODS: This is a retrospective analysis of consecutive patients (between April 1st 2014 and April 30th 2016) at a single center without permanent pacemaker at the time of TAVI who underwent implantation of a permanent pacemaker lead after TAVI connected to an external generator. Focus was the examination of feasibility and safety of our aforementioned approach. In addition, data analysis was performed separating patients into two groups depending on whether (group 1) or not (group 2) permanent pacemaker implantation was ultimately needed. RESULTS: Per our institutional protocol, all consecutive 114 patients underwent insertion of a permanent pacemaker lead after TAVI connected to an external generator. There was one pericardial effusion on postoperative day one that may have been related to the left ventricular wire for TAVI valve delivery. However, perforation due to the pacemaker lead cannot be excluded. Specifically, no access site complications, lead dislodgments or infections occurred. All patients were able to ambulate after the procedure without delay. The permanent pacemaker lead remained in place on average for 4.3 days in group 1 (n = 10) and 4.4 days in group 2 (n = 104) (variance of 3.8 and 3.4 days respectively, [minimum/maximum 0/11 days and 1 and 12 days]). Of the ten patients (9%) who required permanent pacemaker implantation, 8 had a complete atrioventricular block and two had tachy-brady arrhythmias in the context of atrial fibrillation. None of the baseline characteristics including baseline conduction abnormalities were predictors for PPI. CONCLUSION: Implantation of a permanent pacemaker lead connected to an external generator is feasible and safe and could be a better option than implantation of a temporary lead connected to an external generator. It may allow earlier ambulation and facilitate monitoring.


Asunto(s)
Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial , Suministros de Energía Eléctrica , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Estimulación Cardíaca Artificial/efectos adversos , Diseño de Equipo , Estudios de Factibilidad , Femenino , Humanos , Masculino , Seguridad del Paciente , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento
20.
JACC Cardiovasc Interv ; 13(23): 2782-2791, 2020 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-33303117

RESUMEN

OBJECTIVES: The aim of this study was to describe baseline characteristics, and periprocedural and mid-term outcomes of patients undergoing transcatheter mitral valve interventions post-transcatheter aortic valve replacement (TAVR) and examine their clinical benefit. BACKGROUND: The optimal management of residual mitral regurgitation (MR) post-TAVR is challenging. METHODS: This was an international registry of 23 TAVR centers. RESULTS: In total, 106 of 24,178 patients (0.43%) underwent mitral interventions post-TAVR (100 staged, 6 concomitant), most commonly percutaneous edge-to-edge mitral valve repair (PMVR). The median interval post-TAVR was 164 days. Mean age was 79.5 ± 7.2 years, MR was >moderate in 97.2%, technical success was 99.1%, and 30-day device success rate was 88.7%. There were 18 periprocedural complications (16.9%) including 4 deaths. During a median follow-up of 464 days, the cumulative risk for 3-year mortality was 29.0%. MR grade and New York Heart Association (NYHA) functional class improved dramatically; at 1 year, MR was moderate or less in 90.9% of patients (mild or less in 69.1%), and 85.9% of patients were in NYHA functional class I/II. Staged PMVR was associated with lower mortality versus medical treatment (57.5% vs. 30.8%) in a propensity-matched cohort (n = 156), but this was not statistically significant (hazard ratio: 1.75; p = 0.05). CONCLUSIONS: For patients who continue to have significant MR, remain symptomatic post-TAVR, and are anatomically suitable for transcatheter interventions, these interventions are feasible, safe, and associated with significant improvement in MR grade and NYHA functional class. These results apply mainly to PMVR. A staged PMVR strategy was associated with markedly lower mortality, but this was not statistically significant. (Transcatheter Treatment for Combined Aortic and Mitral Valve Disease. The Aortic+Mitral TRAnsCatheter Valve Registry [AMTRAC]; NCT04031274).


Asunto(s)
Insuficiencia de la Válvula Mitral , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Sistema de Registros , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA