Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Lancet ; 394(10194): 230-239, 2019 07 20.
Artículo en Inglés | MEDLINE | ID: mdl-31204115

RESUMEN

BACKGROUND: The optimal technique of percutaneous coronary intervention in patients at high bleeding risk is not known. The hypothesis of the DEBUT trial was that percutaneous coronary intervention with drug-coated balloons is non-inferior to percutaneous coronary intervention with bare-metal stents for this population. METHODS: The DEBUT trial is a randomised, single-blind non-inferiority trial done at five sites in Finland. Patients were eligible if they had an ischaemic de-novo lesion in a coronary artery or bypass graft that could be treated with drug-coated balloons, at least one risk factor for bleeding, and a reference vessel diameter of 2·5-4·0 mm. Those with myocardial infarction with ST-elevation, bifurcation lesions needing a two-stent technique, in-stent restenosis, and flow-limiting dissection or substantial recoil (>30%) of the target lesion after predilation were excluded. After successful predilation of the target lesion, patients were randomly assigned (1:1), by use of a computer-generated random sequence, to percutaneous coronary intervention with a balloon coated with paclitaxel and iopromide or a bare-metal stent. The primary outcome was major adverse cardiac events at 9 months. Non-inferiority was shown if the absolute risk difference was no more than 3%. All prespecified analyses were done in the intention-to-treat population. This trial is registered with ClinicalTrials.gov, number NCT01781546. FINDINGS: Between May 22, 2013, and Jan 16, 2017, 220 patients were recruited for the study and 208 patients were assigned to percutaneous coronary intervention with drug-coated balloon (n=102) or bare metal stent (n=106). At 9 months, major adverse cardiac events had occurred in one patient (1%) in the drug-coated balloon group and in 15 patients (14%) in the bare-metal stent group (absolute risk difference -13·2 percentage points [95% CI -6·2 to -21·1], risk ratio 0·07 [95% CI 0·01 to 0·52]; p<0·00001 for non-inferiority and p=0·00034 for superiority). Two definitive stent thrombosis events occurred in the bare metal stent group but no acute vessel closures in the drug-coated balloon group. INTERPRETATIONS: Percutaneous coronary intervention with drug-coated balloon was superior to bare-metal stents in patients at bleeding risk. The drug-coated balloon-only coronary intervention is a novel strategy to treat this difficult patient population. Comparison of this approach to the new generation drug-eluting stents is warranted in the future. FUNDING: B Braun Medical AG, AstraZeneca, and Competitive State Research Funding of the Kuopio University Hospital Catchment Area.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/patología , Reestenosis Coronaria/prevención & control , Femenino , Hemorragia/etiología , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Paclitaxel/administración & dosificación , Método Simple Ciego , Stents , Moduladores de Tubulina/administración & dosificación
2.
Catheter Cardiovasc Interv ; 93(5): 893-900, 2019 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-30380186

RESUMEN

OBJECTIVES: The aim of this single center all-comers retrospective registry study was to assess the efficacy and safety of percutaneous coronary intervention (PCI) using drug-coated balloon (DCB) in de novo lesions including large proximal coronary arteries. METHODS: A total of 487 PCIs were performed using paclitaxel-coated DCB in 562 de novo lesions with the possibility for bailout stenting in a patient population presenting with stable coronary artery disease (CAD) or acute coronary syndrome (ACS). Half of the patients had at least one risk factor for bleeding. All of the treated lesions were de novo and 60% of DCBs used were ≥ 3.0 mm in diameter. The median follow-up time was 18 months for MACE and 60 months for survival. RESULTS: The total mortality after DBC only strategy was 2.3 and 9.3% at 12 months in stable CAD and ACS, respectively. The 12-month MACE rate was 7.1 and 12% in stable CAD and ACS. The rate of ischemia-driven target lesion revascularization was only 1.4% in stable CAD and 2.8% after ACS at 12 months. Median duration of DAPT was one month. The 12 month rate of significant bleeding (Bleeding Academic Research Consortium types 2-5) was 5.9%. Acute vessel closure occurred only in one case (0.2%) after DCB treatment. Bailout stenting was used in 12% of lesions. CONCLUSIONS: PCI using DCB-only strategy with the possibility for provisional stenting is a safe and efficient in de novo coronary artery lesions in both stable CAD and ACS. This strategy may be useful especially in patients with high bleeding risk.


Asunto(s)
Síndrome Coronario Agudo/terapia , Angina Inestable/terapia , Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Infarto del Miocardio sin Elevación del ST/terapia , Paclitaxel/administración & dosificación , Infarto del Miocardio con Elevación del ST/terapia , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/mortalidad , Anciano , Anciano de 80 o más Años , Angina Inestable/diagnóstico por imagen , Angina Inestable/mortalidad , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Hemorragia/etiología , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio sin Elevación del ST/diagnóstico por imagen , Infarto del Miocardio sin Elevación del ST/mortalidad , Paclitaxel/efectos adversos , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/mortalidad , Factores de Tiempo , Resultado del Tratamiento
3.
Eur Heart J ; 39(8): 676-684, 2018 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-29253177

RESUMEN

Aims: Life-threatening complications occur during transcatheter aortic valve implantation (TAVI) which can require emergent cardiac surgery (ECS). Risks and outcomes of patients needing ECS during or immediately after TAVI are still unclear. Methods and results: Incidence, risk factors, management, and outcomes of patients requiring ECS during transfemoral (TF)-TAVI were analysed from a contemporary real-world multicentre registry. Between 2013 and 2016, 27 760 patients underwent TF-TAVI in 79 centres. Of these, 212 (0.76%) patients required ECS (age 82.4 ± 6.3 years, 67.5% females, logistic EuroSCORE: 17.1%, STS-score 5.8%). The risk of ECS declined from 2013 (1.07%) to 2014 (0.70%) but remained stable since. Annual TF-TAVI numbers have more than doubled from 2013 to 2016. Leading causes for ECS were left ventricular perforation by the guidewire (28.3%) and annular rupture (21.2%). Immediate procedural mortality (<72 h) of TF-TAVI patients requiring ECS was 34.6%. Overall in-hospital mortality was 46.0%, and highest in case of annular rupture (62%). Independent predictors of in-hospital mortality following ECS were age > 85 years [odds ratio (OR) 1.87, 95% confidence interval (95% CI) (1.02-3.45), P = 0.044], annular rupture [OR 1.96, 95% CI (0.94-4.10), P = 0.060], and immediate ECS [OR 3.12, 95% CI (1.07-9.11), P = 0.037]. One year of survival of the 114 patients surviving the in-hospital period was only 40.4%. Conclusion: Between 2014 and 2016, the need for ECS remained stable around 0.7%. Left ventricular guidewire perforation and annular rupture were the most frequent causes, accounting for almost half of ECS cases. Half of the patients could be salvaged by ECS-nevertheless, 1 year of all-cause mortality was high even in those ECS patients surviving the in-hospital period.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Procedimientos Quirúrgicos Cardíacos/estadística & datos numéricos , Mortalidad Hospitalaria/tendencias , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Procedimientos Quirúrgicos Cardíacos/tendencias , Tratamiento de Urgencia/tendencias , Europa (Continente)/epidemiología , Femenino , Humanos , Incidencia , Masculino , Sistema de Registros , Medición de Riesgo
4.
J Interv Cardiol ; 30(2): 139-146, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28116778

RESUMEN

OBJECTIVES: We investigated the safety and efficacy of PCI using drug-coated balloon (DCB) after rotational atherectomy (rotablation) in a retrospective single center study in patients with calcified de novo coronary lesions. The majority of patients had an increased risk for bleeding. BACKGROUND: DCB has been effective in the treatment of in-stent restenosis, small vessels, and bifurcations. DCB enables short one month dual antiplatelet treatment. No published data exist on the use of DCB after rotablation. METHODS: 82 PCIs were performed in 65 patients (mean age 72 ± 10 years) using rotablation followed by DCB treatment. The median follow-up time was 17 months. 82% of the patients had at least one risk factor for bleeding such as oral anticoagulation. 32% had an acute coronary syndrome. Median duration of dual antiplatelet treatment was 1 month. RESULTS: MACE (the composite of cardiovascular death, ischemia-driven target-lesion revascularization [TLR] or non-fatal myocardial infarction) occurred in 14% and 20% of the patients at 12 and 24 months, respectively. The rate of ischemia-driven TLR was 1.5% at 12 months and 3.0% at 24 months. No acute closure of the treated vessel occurred. Bailout stenting was needed in 10% of the PCIs. The incidence of significant bleeding was 9% at 12 months. CONCLUSIONS: This is the first study to show that PCI using DCB after preparation of calcified lesions with rotablation is safe and effective. This novel strategy may be considered especially in patients with a bleeding risk such as those using an oral anticoagulant.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Aterectomía Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Calcificación Vascular/cirugía , Anciano , Anciano de 80 o más Años , Materiales Biocompatibles Revestidos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel , Estudios Retrospectivos , Stents , Resultado del Tratamiento
5.
Int J Cardiol ; 263: 29-31, 2018 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-29681408

RESUMEN

BACKGROUND: The MANTA system is a novel vascular closure device (VCD) and its safety and efficacy were compared to the ProGlide VCD in patients undergoing transfemoral transcatheter aortic valve implantation (TAVI). METHODS: This is a retrospective study including 222 patients who underwent transfemoral TAVI at three Finnish University Hospitals. The MANTA VCD was used in 107 patients and their outcome was compared with that of 115 patients in whom the arterial access was closed with the ProGlide VCD. RESULTS: VARC-2 VCD failure occurred less frequently in the MANTA cohort (3.7% vs. 7.8%, p = 0.378), but the difference did not reach statistical significance. When adjusted for the introducer outer diameter, the MANTA cohort had similar rates of VARC-2 major vascular complications (9.3% vs. 12.2%, adjusted: p = 0.456), VARC-2 life-threatening/disabling bleeding (9.3% vs. 6.1%, adjusted: p = 0.296) and need of invasive treatment of bleeding (4.7% vs. 7.0%, adjusted: p = 0.416) compared to the ProGlide cohort. Additional VCDs were more frequently needed in the ProGlide cohort (58.3% vs. 1.9%, p < 0.0001). CONCLUSIONS: In patients undergoing transfemoral TAVI, the MANTA VCD showed a similar risk of VARC-2 vascular and bleeding complications compared to the ProGlide VCD, but it reduced significantly the need of additional VCDs for completion of hemostasis.


Asunto(s)
Pérdida de Sangre Quirúrgica/prevención & control , Arteria Femoral/cirugía , Complicaciones Intraoperatorias/diagnóstico , Complicaciones Intraoperatorias/epidemiología , Reemplazo de la Válvula Aórtica Transcatéter/normas , Dispositivos de Cierre Vascular/normas , Anciano , Anciano de 80 o más Años , Femenino , Finlandia/epidemiología , Humanos , Masculino , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Dispositivos de Cierre Vascular/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA