Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
ASAIO J ; 70(7): 557-564, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38386980

RESUMEN

Data regarding outcomes with Impella 5.5 are limited. The aim of this systematic review and meta-analysis was to summarize patient and treatment characteristics and early clinical outcomes among patients supported by Impella 5.5. A systematic literature search was conducted in PubMed, Scopus, and Cochrane databases from September 2019 to March 2023. Studies reporting outcomes in greater than or equal to 5 patients were included for review. Patient characteristics, treatment characteristics, and early clinical outcomes were extracted. Outcomes included adverse events, survival to hospital discharge, and 30 day survival. Random-effect models were used to estimate pooled effects for survival outcomes. Assessment for bias was performed using funnel plots and Egger's tests. Fifteen studies were included for qualitative review, representing 707 patients. Mean duration of support was 9.9 ± 8.2 days. On meta-analysis of 13 studies reporting survival outcomes, survival to hospital discharge was 68% (95% confidence interval [CI], 58-78%), and 30 day survival was 65% (95% CI, 56-74%) among patients with Impella devices predominantly supported by Impella 5.5 (>60%). There was significant study heterogeneity for these outcomes. Among 294 patients with Impella 5.5 only, survival to discharge was 78% (95% CI, 72-82%) with no significant study heterogeneity. This data present early benchmarks for outcomes with Impella 5.5 as clinical experience with these devices accrues.


Asunto(s)
Corazón Auxiliar , Humanos , Resultado del Tratamiento , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/mortalidad
2.
Artículo en Inglés | MEDLINE | ID: mdl-38367698

RESUMEN

OBJECTIVES: The HeartMate 3 (Abbott) left ventricular assist device provides substantial improvement in long-term morbidity and mortality in patients with advanced heart failure. The Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study compares thoracotomy-based implantation clinical outcomes with standard median sternotomy. METHODS: We conducted a prospective, multicenter, single-arm study in patients eligible for HeartMate 3 implantation with thoracotomy-based surgical technique (bilateral thoracotomy or partial upper sternotomy with left thoracotomy). The composite primary end point was survival free of disabling stroke (modified Rankin score >3), or reoperation to remove or replace a malfunctioning device, or conversion to median sternotomy at 6-months postimplant (elective transplants were treated as a success). The primary end point (noninferiority, -15% margin) was assessed with >90% power compared with a propensity score-matched cohort (ratio 1:2) derived from the Multi-Center Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 continued access protocol. RESULTS: The study enrolled 102 patients between December 2020 and July 2022 in the thoracotomy-based arm at 23 North American centers. Follow-up concluded in December 2022. In the Implantation of the HeartMate 3 in Subjects With Heart Failure Using Surgical Techniques Other Than Full Median Sternotomy study group, noninferiority criteria was met (absolute between-group difference, -1.2%; Farrington Manning lower 1-sided 95% CI, -9.3%; P < .0025) and event-free survival was not different (85.0% vs 86.2%; hazard ratio, 1.01; 95% CI, 0.58-2.10). Length of stay with thoracotomy-based implant was longer (median, 20 vs 17 days; P = .03). No differences were observed for blood product utilization, adverse events (including right heart failure), functional status, and quality of life between cohorts. CONCLUSIONS: Thoracotomy-based implantation of the HeartMate 3 left ventricular assist device is noninferior to implantation via standard full sternotomy. This study supports thoracotomy-based implantation as an additional standard for surgical implantation of the HeartMate 3 left ventricular assist device.

3.
Ann Thorac Surg ; 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39023462

RESUMEN

BACKGROUND: Thoracoabdominal normothermic regional perfusion (TA-NRP) has emerged as a powerful technique for optimizing organ procurement from donation after circulatory death donors. Despite its rapid adoption, standardized guidelines for TA-NRP implementation are lacking, prompting the need for consensus recommendations to ensure safe and effective utilization of this technique. METHODS: A working group composed of members from The American Society of Transplant Surgeons, The International Society of Heart and Lung Transplantation, The Society of Thoracic Surgeons, and The American Association for Thoracic Surgery was convened to develop technical guidelines for TA-NRP. The group systematically reviewed existing literature, consensus statements, and expert opinions to identify key areas requiring standardization, including predonation evaluation, intraoperative management, postdonation procedures, and future research directions. RESULTS: The working group formulated recommendations encompassing donor evaluation and selection criteria, premortem testing and therapeutic interventions, communication protocols, and procedural guidelines for TA-NRP implementation. These recommendations aim to facilitate coordination among transplant teams, minimize variability in practice, and promote transparency and accountability throughout the TA-NRP process. CONCLUSIONS: The consensus guidelines presented herein serve as a comprehensive framework for the successful and ethical implementation of TA-NRP programs in organ procurement from donation after circulatory death donors. By providing standardized recommendations and addressing areas of uncertainty, these guidelines aim to enhance the quality, safety, and efficiency of TA-NRP procedures, ultimately contributing to improved outcomes for transplant recipients.

4.
Transplantation ; 108(8): 1669-1680, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39012953

RESUMEN

BACKGROUND: Thoracoabdominal normothermic regional perfusion (TA-NRP) has emerged as a powerful technique for optimizing organ procurement from donation after circulatory death donors. Despite its rapid adoption, standardized guidelines for TA-NRP implementation are lacking, prompting the need for consensus recommendations to ensure safe and effective utilization of this technique. METHODS: A working group composed of members from The American Society of Transplant Surgeons, The International Society of Heart and Lung Transplantation, The Society of Thoracic Surgeons, and The American Association for Thoracic Surgery was convened to develop technical guidelines for TA-NRP. The group systematically reviewed existing literature, consensus statements, and expert opinions to identify key areas requiring standardization, including predonation evaluation, intraoperative management, postdonation procedures, and future research directions. RESULTS: The working group formulated recommendations encompassing donor evaluation and selection criteria, premortem testing and therapeutic interventions, communication protocols, and procedural guidelines for TA-NRP implementation. These recommendations aim to facilitate coordination among transplant teams, minimize variability in practice, and promote transparency and accountability throughout the TA-NRP process. CONCLUSIONS: The consensus guidelines presented herein serve as a comprehensive framework for the successful and ethical implementation of TA-NRP programs in organ procurement from donation after circulatory death donors. By providing standardized recommendations and addressing areas of uncertainty, these guidelines aim to enhance the quality, safety, and efficiency of TA-NRP procedures, ultimately contributing to improved outcomes for transplant recipients.


Asunto(s)
Consenso , Preservación de Órganos , Perfusión , Humanos , Perfusión/normas , Perfusión/métodos , Preservación de Órganos/normas , Preservación de Órganos/métodos , Donantes de Tejidos/provisión & distribución , Trasplante de Órganos/normas , Trasplante de Órganos/métodos , Selección de Donante/normas , Obtención de Tejidos y Órganos/normas , Obtención de Tejidos y Órganos/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA