Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 114
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 94(1): 82-90, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-30666784

RESUMEN

OBJECTIVE: We evaluated 1-year outcomes after platinum chromium everolimus-eluting stents (PtCr-EES) in small versus non-small coronary arteries within a large, diverse sample of men, women, and minorities. BACKGROUND: There exists limited outcomes data on the use of second-generation drug-eluting stent to treat small diameter coronary arteries. METHODS: We pooled patients from the PLATINUM Diversity and PROMUS Element Plus stent registries. Small-vessel percutaneous coronary intervention (SV-PCI) was defined as ≥1 target lesion with reference vessel diameter (RVD) ≤2.5 mm. Endpoints included major adverse cardiac event (MACE; death, myocardial infarction [MI] or target vessel revascularization [TVR]), target vessel failure (TVF; death related to the target vessel, target vessel MI or TVR) and definite/probable stent thrombosis (ST). Multivariable Cox regression was used to risk-adjust outcomes. RESULTS: We included 4,155/4,182 (99%) patients with available RVD, of which 1,607 (39%) underwent small-vessel PCI. SV-PCI was not associated with increased MACE (adjHR 1.02; 95%CI 0.81-1.30) or TVF (adjHR 1.07; 95%CI 0.82-1.39). MI risk was lower in white men compared to women and minorities, both in the setting of SV-PCI (adjHR 0.41; 95%CI 0.23-0.74 and adjHR 0.39; 95%CI 0.20-0.75, respectively) and for non-SV-PCI (adjHR 0.61; 95%CI 0.38-0.99 and adjHR 0.45; 95%CI 0.27-0.74, respectively). There was no significant interaction between RVD and sex or minority status for any endpoint. CONCLUSION: In a large diverse contemporary PCI outcomes database, SV-PCI with PtCr-EES was not associated with increased MACE or TVR and did not account for the increased MI risk noted in women and minorities compared to white men.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Cromo , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Disparidades en el Estado de Salud , Salud de las Minorías , Intervención Coronaria Percutánea/instrumentación , Platino (Metal) , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/etnología , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/etnología , Trombosis Coronaria/mortalidad , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etnología , Infarto del Miocardio/mortalidad , Estudios Observacionales como Asunto , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Factores Raciales , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores Sexuales , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos/epidemiología
2.
Am J Ther ; 23(3): e905-10, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-25828517

RESUMEN

Vascular inflammation is a key component involved in the process of arthrosclerosis, which in turn increases the risk for cardiovascular injury. In the last 10 years, there have been many trials that looked at omega-3 fatty acids as a way to reduce cardiovascular risk. These trials observed the effects of eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) on the traditional lipid panel and found that both EPA and DHA reduce triglyceride (TG) level and increase high-density lipoprotein cholesterol (HDL-C) levels but also increase the low-density lipoprotein cholesterol (LDL-C) levels. In the 2 more recent trials, the MARINE and ANCHOR, EPA was given as an adjunct therapy to high-risk patients and not only was the traditional lipids measured but also examined the vascular inflammatory biomarkers. The results of these 2 trials not only showed reduction in cardiovascular risk because of reduction in vascular inflammation and reduction in the lipid panel but also showed that one of the MARINE-derived omega-3 fatty acid is superior to the other. Data search for omega-3 fatty acids and cardiovascular risk was performed, and articles were selected for review from 2006 to date. The research studies were all double-blind randomized trials except for one, which was a single-blind and focused on the effects of omega-3 fatty acids on the entire lipid panel. The participants received DHA/EPA and compared with a placebo group on the effect seen in the lipid panel. The first 7 studies looked at the effects of omega-3 fatty acids on TG, LDL-C, and HDL-C; of the 7, 1 directly compared DHA and EPA, 2 focused on EPA, and 4 were directed towards DHA alone. The MARINE and ANCHOR trials were more recent and also looked at the same parameter but also monitored vascular inflammatory biomarkers and how they were affected by omega-3 fatty acids. A second data search was performed for vascular biomarkers and cardiovascular risk, and articles that focused on high-sensitivity C-reactive protein and oxidized low-density lipoprotein were selected for review. Omega-3 fatty acids have shown to decrease TG level in multiple trials, but they have also shown to increase LDL and HDL levels, likely because omega-3 fatty acids promote TG conversion into HDL/LDL. The older data suggested that the benefits of omega-3 fatty acids are nullified by their effects on LDL levels. The data from the MARINE and ANCHOR trials have shown that EPA alone at 4 g per day has shown to decrease TG and total cholesterol without affecting the LDL levels. The earlier data showed that both EPA and DHA decreased TG level and increased levels of HDL-C, but that the DHA alone and direct comparison of DHA/EPA showed that DHA has more undesirable effects on LDL. Furthermore, the MARINE and ANCHOR trials have both shown that not only does EPA improve the lipid panel but also helps to decrease the levels of the vascular inflammatory biomarkers, thus further helping to decrease cardiovascular risk. The use of EPA as an adjunct therapy for high-risk patient has shown to help decrease cardiovascular risk. The reduction in risk is performed not only by decreasing TG but also by reducing vascular inflammation. Although because there are no randomized double-blind study looking at this, the research is inconclusive and requires further investigation.


Asunto(s)
Enfermedades Cardiovasculares/prevención & control , Ácidos Docosahexaenoicos/uso terapéutico , Ácido Eicosapentaenoico/uso terapéutico , HDL-Colesterol/sangre , Humanos , Factores de Riesgo , Resultado del Tratamiento , Triglicéridos/sangre , Vasculitis/prevención & control
3.
AJR Am J Roentgenol ; 204(1): W4-10, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25539272

RESUMEN

OBJECTIVE: This article describes tube potential and its effect on image quality and radiation dose for CT in different body regions and clinical indications. CONCLUSION: Tube potential is an important scanning parameter for radiation dose optimization. Reduction of tube potential results in increased image contrast of iodine-enhanced CT as well as increased image noise.


Asunto(s)
Dosis de Radiación , Protección Radiológica/métodos , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos
4.
AJR Am J Roentgenol ; 205(1): W19-31, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26102414

RESUMEN

OBJECTIVE: This article discusses the clinical challenge of low-radiation-dose examinations, the commonly used approaches for dose optimization, and their effect on image quality. We emphasize practical aspects of the different iterative reconstruction techniques, along with their benefits, pitfalls, and clinical implementation. CONCLUSION: The widespread use of CT has raised concerns about potential radiation risks, motivating diverse strategies to reduce the radiation dose associated with CT. CT manufacturers have developed alternative reconstruction algorithms intended to improve image quality on dose-optimized CT studies, mainly through noise and artifact reduction. Iterative reconstruction techniques take unique approaches to noise reduction and provide distinct strength levels or settings.


Asunto(s)
Dosis de Radiación , Protección Radiológica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Abdominal/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Humanos
5.
AJR Am J Roentgenol ; 204(4): W384-92, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25794087

RESUMEN

1. CT radiation dose optimization is one of the major concerns for the scientific community. 2. CT image quality is dependent on the selected image reconstruction algorithm. 3. Iterative reconstruction algorithms have reemerged with the potential of radiation dose optimization by lowering image noise. 4. Tube current is the most common parameter used to reduce radiation dose along with iterative reconstruction. 5. Tube potential (kV) is also used for dose optimization with iterative reconstruction in CT angiography protocols and small patients.


Asunto(s)
Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Humanos , Protección Radiológica/métodos , Tomografía Computarizada por Rayos X/instrumentación
6.
AJR Am J Roentgenol ; 204(1): 167-76, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25539253

RESUMEN

OBJECTIVE: Size-specific dose estimates (SSDEs) require manual measurement of torso diameters for individual patients--anteroposterior (hereafter, D(AP)), lateral (hereafter, D(LAT)), and effective (hereafter, D(E))--which can be tedious in clinical settings. We aimed to determine whether body weight can be used as a surrogate for measuring diameter in children. MATERIALS AND METHODS: D(AP) and D(LAT) were measured in 522 consecutive CT examinations (chest, 187 and abdomen-pelvis, 335) performed in 483 (± SD) children (13 ± 7 years). Effective diameter (D(E1)) was calculated as the square root of the product of D(AP) and D(LAT). A second measurement of effective diameter (D(E2)) was obtained using automated software. Correlation coefficients between patient body weight, age, and diameter were measured in addition to 95% prediction interval analysis for diameters corresponding to body weight. RESULTS: Median body weight was 51 kg, and mean D(AP), D(LAT), D(E1), and D(E2) were 207.1 ± 50.8 mm, 289.8 ± 72.6 mm, 243.3 ± 62.0 mm, and 233.6 ± 55.4 mm, respectively. Overall body weight had a strong correlation with diameter (0.88, 0.85, 0.86, and 0.93 respectively; all p < 0.0001). SSDE measured using body weight was statistically not different than SSDE measured using effective diameters (p = 0.9). Children weighing less than 27 kg and between 46 and 100 kg had statistically significant correlations with torso diameters, whereas only anteroposterior and effective diameters were correlated with children weighing between 27 and 45 kg. Children less than 4 years old had strong correlation with all diameters. Adolescents (15-18 years) did not have statistically significant correlation with any of the diameters. CONCLUSION: Body weight, instead of body diameter, can be used as a surrogate to estimate size-specific dose in children, making dose estimation clinically simpler and more rapid.


Asunto(s)
Absorción de Radiación , Algoritmos , Peso Corporal/fisiología , Modelos Biológicos , Dosis de Radiación , Radiometría/métodos , Tomografía Computarizada por Rayos X/métodos , Adolescente , Niño , Preescolar , Simulación por Computador , Femenino , Humanos , Lactante , Recién Nacido , Masculino
7.
AJR Am J Roentgenol ; 204(2): 335-42, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25615756

RESUMEN

OBJECTIVE. The purpose of this article is to project the effects of radiation exposure on life expectancy (LE) in patients who opt for CT-guided radiofrequency ablation (RFA) instead of surgery for renal cell carcinoma (RCC). MATERIALS AND METHODS. We developed a decision-analytic Markov model to compare LE losses attributable to radiation exposure in hypothetical 65-year-old patients who undergo CT-guided RFA versus surgery for small (≤ 4 cm) RCC. We incorporated mortality risks from RCC, radiation-induced cancers (for procedural and follow-up CT scans), and all other causes; institutional data informed the RFA procedural effective dose. Radiation-induced cancer risks were generated using an organ-specific approach. Effects of varying model parameters and of dose-reduction strategies were evaluated in sensitivity analysis. RESULTS. Cumulative RFA exposures (up to 305.2 mSv for one session plus surveillance) exceeded those from surgery (up to 87.2 mSv). In 65-year-old men, excess LE loss from radiation-induced cancers, comparing RFA to surgery, was 11.7 days (14.6 days for RFA vs 2.9 days for surgery). Results varied with sex and age; this difference increased to 14.6 days in 65-year-old women and to 21.5 days in 55-year-old men. Dose-reduction strategies that addressed follow-up rather than procedural exposure had a greater impact. In 65-year-old men, this difference decreased to 3.8 days if post-RFA follow-up scans were restricted to a single phase; even elimination of RFA procedural exposure could not achieve equivalent benefits. CONCLUSION. CT-guided RFA remains a safe alternative to surgery, but with decreasing age, the higher burden of radiation exposure merits explicit consideration. Dose-reduction strategies that target follow-up rather than procedural exposure will have a greater impact.


Asunto(s)
Carcinoma de Células Renales/mortalidad , Carcinoma de Células Renales/cirugía , Ablación por Catéter/métodos , Neoplasias Renales/mortalidad , Neoplasias Renales/cirugía , Esperanza de Vida , Neoplasias Inducidas por Radiación/epidemiología , Neoplasias Inducidas por Radiación/etiología , Cirugía Asistida por Computador , Tomografía Computarizada por Rayos X/efectos adversos , Anciano , Carcinoma de Células Renales/diagnóstico por imagen , Femenino , Humanos , Neoplasias Renales/diagnóstico por imagen , Masculino , Dosis de Radiación , Medición de Riesgo
8.
J Comput Assist Tomogr ; 39(4): 489-98, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26182223

RESUMEN

PURPOSE: To assess lesion detection and image quality of ultralow-dose (ULD) abdominal computed tomography (CT) reconstructed with filtered back projection (FBP) and 2 iterative reconstruction techniques: hybrid-based iDose, and image-based SafeCT. MATERIALS AND METHODS: In this institutional review board-approved ongoing prospective clinical study, 41 adult patients provided written informed consent for an additional ULD abdominal CT examination immediately after standard dose (SD) CT exam on a 256-slice multidetector computed tomography (iCT, Philips-Healthcare). The SD examination (size-specific dose estimate, 10 ± 3 mGy) was performed at 120 kV with automatic exposure control, and reconstructed with FBP. The ULD examination (1.5 ± 0.4 mGy) was performed at 120 kV and fixed tube current of 17 to 20 mAs/slice to achieve ULD radiation dose, with the rest of the scan parameters same as SD examination. The ULD data were reconstructed with (a) FBP, (b) iDose, and (c) SafeCT. Lesions were detected on ULD FBP series and compared to SD FBP "reference-standard" series. True lesions, pseudolesions, and missed lesions were recorded. Four abdominal radiologists independently blindly performed subjective image quality. Objective image quality included image noise calculation and noise spectral density plots. RESULTS: All true lesions (n, 52: liver metastases, renal cysts, diverticulosis) in SD FBP images were detected in ULD images. Although there were no missed or pseudolesions on ULD iDose and ULD SafeCT images, appearance of small low-contrast hepatic lesions was suboptimal. The ULD FBP images were unacceptable across all patients for both lesion detection and image quality. In patients with a body mass index (BMI) of 25 kg/m or less, ULD iDose and ULD SafeCT images were acceptable for image quality that was close to SD FBP for both normal and abnormal abdominal and pelvic structures. With increasing BMI, the image quality of ULD images was deemed unacceptable due to photo starvation. Evaluation of kidney stones with ULD iDose/SafeCT images was found acceptable regardless of patient size. Image noise levels were significantly lower in ULD iDose and ULD SafeCT images compared to ULD FBP (P < 0.01). CONCLUSIONS: Preliminary results show that ULD abdominal CT reconstructed with iterative reconstruction techniques is achievable in smaller patients (BMI ≤ 25 kg/m) but remains a challenge for overweight to obese patients. Lesion detection is similar in full-dose SD FBP and ULD iDose/SafeCT images, with suboptimal visibility of low-contrast lesions in ULD images.


Asunto(s)
Tomografía Computarizada Multidetector/métodos , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Abdominal/métodos , Medios de Contraste , Divertículo/diagnóstico por imagen , Femenino , Humanos , Yopamidol , Enfermedades Renales/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Prospectivos
9.
J Comput Assist Tomogr ; 39(4): 462-7, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25734468

RESUMEN

PURPOSE: To compare standard of care and reduced dose (RD) abdominal computed tomography (CT) images reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), model-based iterative reconstruction (MBIR) techniques. MATERIALS AND METHODS: In an Institutional Review Board-approved, prospective clinical study, 28 patients (mean age 59 ± 13 years ), undergoing clinically indicated routine abdominal CT on a 64-channel multi-detector CT scanner, gave written informed consent for acquisition of an additional RD (<1 milli-Sievert) abdomen CT series. Sinogram data of RD series were reconstructed with FBP, ASIR, and MBIR and compared with FBP images of standard dose abdomen CT. Two radiologists performed randomized, independent, and blinded comparison for lesion detection, lesion margin, visibility of normal structures, and diagnostic confidence. RESULTS: Mean CT dose index volume was 10 ± 3.4 mGy and 1.3 ± 0.3 mGy for standard and RD CT, respectively. There were 73 "true positive" lesions detected on standard of care CT. Nine lesions (<8 mm in size) were missed on RD abdominal CT images which included liver lesions, liver cysts, kidney cysts, and paracolonic abscess. These lesions were missed regardless of patient size and types of iterative reconstruction techniques used for reconstruction of RD data sets. The visibility of lesion margin was suboptimal in (23/28) patients with RD FBP, (15/28) patients with RD ASIR, and (14/28) patients with RD MBIR compared to standard of care FBP images (P < 0.001). Diagnostic confidence for the assessment of lesions on RD images was suboptimal in most patients regardless of iterative reconstruction techniques. CONCLUSIONS: Clinically significant lesions (< 8 mm) can be missed on abdominal CT examinations acquired at a CT dose index volume of 1.3 mGy regardless of patients' size and reconstruction techniques (FBP, ASIR, and MBIR).


Asunto(s)
Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador , Radiografía Abdominal , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Yopamidol , Masculino , Persona de Mediana Edad , Modelos Teóricos , Variaciones Dependientes del Observador , Estudios Prospectivos
10.
Acta Radiol ; 56(6): 688-95, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24948790

RESUMEN

BACKGROUND: Lowering radiation dose in computed tomography (CT) scan results in low quality noisy images. Iterative reconstruction techniques are used currently to lower image noise and improve the quality of images. PURPOSE: To evaluate lesion detection and diagnostic acceptability of chest CT images acquired at CTDIvol of 1.8 mGy and processed with two different iterative reconstruction techniques. MATERIAL AND METHODS: Twenty-two patients (mean age, 60 ± 14 years; men, 13; women, 9; body mass index, 27.4 ± 6.5 kg/m(2)) gave informed consent for acquisition of low dose (LD) series in addition to the standard dose (SD) chest CT on a 128 - multidetector CT (MDCT). LD images were reconstructed with SafeCT C4, L1, and L2 settings, and Safire S1, S2, and S3 settings. Three thoracic radiologists assessed LD image series (S1, S2, S3, C4, L1, and L2) for lesion detection and comparison of lesion margin, visibility of normal structures, and diagnostic confidence with SD chest CT. Inter-observer agreement (kappa) was calculated. RESULTS: Average CTDIvol was 6.4 ± 2.7 mGy and 1.8 ± 0.2 mGy for SD and LD series, respectively. No additional lesion was found in SD as compared to LD images. Visibility of ground-glass opacities and lesion margins, as well as normal structures visibility were not affected on LD. CT image visibility of major fissure and pericardium was not optimal in some cases (n = 5). Objective image noise in some low dose images processed with SafeCT and Safire was similar to SD images (P value > 0.5). CONCLUSION: Routine LD chest CT reconstructed with iterative reconstruction technique can provide similar diagnostic information in terms of lesion detection, margin, and diagnostic confidence as compared to SD, regardless of the iterative reconstruction settings.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Dosis de Radiación , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
11.
Pediatr Radiol ; 45(7): 1046-55, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25427434

RESUMEN

Dose reduction in children undergoing CT scanning is an important priority for the radiology community and public at large. Drawbacks of radiation reduction are increased image noise and artifacts, which can affect image interpretation. Iterative reconstruction techniques have been developed to reduce noise and artifacts from reduced-dose CT examinations, although reconstruction algorithm, magnitude of dose reduction and effects on image quality vary. We review the reconstruction principles, radiation dose potential and effects on image quality of several iterative reconstruction techniques commonly used in clinical settings, including 3-D adaptive iterative dose reduction (AIDR-3D), adaptive statistical iterative reconstruction (ASIR), iDose, sinogram-affirmed iterative reconstruction (SAFIRE) and model-based iterative reconstruction (MBIR). We also discuss clinical applications of iterative reconstruction techniques in pediatric abdominal CT.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Abdominal/métodos , Tomografía Computarizada por Rayos X/métodos , Adolescente , Algoritmos , Artefactos , Niño , Preescolar , Femenino , Humanos , Imagenología Tridimensional , Lactante , Masculino , Reproducibilidad de los Resultados
12.
Forensic Sci Med Pathol ; 11(4): 488-96, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26541472

RESUMEN

PURPOSE: Interstitial fluid accumulation can occur in pleural, pericardial, and peritoneal spaces, and subcutaneous tissue planes. The purpose of the study was to assess if whole body CT examination in a postmortem setting could help determine the presence and severity of third space fluid accumulation in the body. MATERIALS AND METHODS: Our study included 41 human cadavers (mean age 61 years, 25 males and 16 females) who had whole-body postmortem CT prior to autopsy. All bodies were maintained in the morgue in the time interval between death and autopsy. Two radiologists reviewed the whole-body CT examinations independently to grade third space fluid in the pleura, pericardium, peritoneum, and subcutaneous space using a 5-point grading system. Qualitative CT grading for third space fluid was correlated with the amount of fluid found on autopsy and the quantitative CT fluid volume, estimated using a dedicated software program (Volume, Syngo Explorer, Siemens Healthcare). RESULTS: Moderate and severe peripheral edema was seen in 16/41 and 7/41 cadavers respectively. It is not possible to quantify anasarca at autopsy. Correlation between imaging data for third space fluid and the quantity of fluid found during autopsy was 0.83 for pleural effusion, 0.4 for pericardial effusion and 0.9 for ascites. The degree of anasarca was significantly correlated with the severity of ascites (p < 0.0001) but not with pleural or pericardial effusion. There was strong correlation between volumetric estimation and qualitative grading for anasarca (p < 0.0001) and pleural effusion (p < 0.0001). CONCLUSION: Postmortem CT can help in accurate detection and quantification of third space fluid accumulation. The quantity of ascitic fluid on postmortem CT can predict the extent of anasarca.


Asunto(s)
Autopsia , Líquido Extracelular/metabolismo , Tomografía Computarizada Multidetector , Imagen de Cuerpo Entero , Adulto , Anciano , Anciano de 80 o más Años , Ascitis/diagnóstico por imagen , Ascitis/patología , Bilirrubina/análisis , Cadáver , Edema/diagnóstico por imagen , Edema/patología , Femenino , Patologia Forense , Humanos , Masculino , Persona de Mediana Edad , Pericardio/diagnóstico por imagen , Pericardio/metabolismo , Pericardio/patología , Peritoneo/diagnóstico por imagen , Peritoneo/metabolismo , Peritoneo/patología , Pleura/diagnóstico por imagen , Pleura/metabolismo , Pleura/patología , Derrame Pleural/diagnóstico por imagen , Derrame Pleural/patología , Albúmina Sérica/análisis , Índice de Severidad de la Enfermedad , Tejido Subcutáneo/diagnóstico por imagen , Tejido Subcutáneo/metabolismo , Tejido Subcutáneo/patología
13.
AJR Am J Roentgenol ; 203(1): 118-22, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24951204

RESUMEN

OBJECTIVE: The objective of our study was to assess the effect of radiation dose reduction on the detection of pleural effusions, thickening, and calcifications. MATERIALS AND METHODS: Forty-five human cadavers (mean age at death, 60 ± 17 [SD] years; male-female ratio, 29:16; mean body mass index, 29 ± 5.7 [SD] kg/m(2)) were scanned at seven different dose levels (CT Dose Index volume [CTDIvol] = 20, 12, 10, 6, 4, 2, and 0.8 mGy) on a 128-MDCT unit (Definition FLASH). Images were reconstructed at a 3-mm slice thickness and 2-mm increment with filtered back projection (FBP) technique. Two chest radiologists independently reviewed all image series for the detection of pleural effusion, pleural calcification, and adjacent parenchymal opacification from atelectasis or consolidation. Objective image noise was measured at each dose level on the pleural effusion using ImageJ software. Data analysis was performed with the Student t test and kappa test. RESULTS: Pleural effusions were seen in 39 of 45 cadavers on image series acquired at 2-20 mGy. Only 14 of 39 pleural effusions were identified at 0.8 mGy. Pleural effusions were not detected in 25 of 39 cadavers at 0.8 mGy because of photon starvation and increased image noise. Patient size was significantly larger in subjects with undetected pleural effusion than in those with detectable pleural effusion at 0.8 mGy (p < 0.01). Pleural calcifications and thickening (seen at 2-10 mGy images in three of three cadavers) were not identified on 0.8-mGy FBP images. On the other hand, adjacent parenchymal opacification could be assessed at all dose levels. The mean CT numbers of the pleural effusion were significantly lower on 0.8-mGy images than on images obtained at all other dose levels (-21 ± 55 [SD] vs 17.6 ± 19 HU, respectively) (p < 0.001). CONCLUSION: Pleural effusions, thickening, and calcifications can be seen on FBP images reconstructed at a CTDIvol as low as 2 mGy (32-cm body phantom). CT at 0.8 mGy may provide suboptimal information on very small pleural effusions, pleural thickening, and calcifications.


Asunto(s)
Derrame Pleural/diagnóstico por imagen , Dosis de Radiación , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Cadáver , Femenino , Humanos , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador
14.
AJR Am J Roentgenol ; 203(4): 772-81, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25247943

RESUMEN

OBJECTIVE: The purpose of this study was to compare submillisievert chest CT images reconstructed with filtered back projection (FBP), SafeCT, adaptive statistical iterative reconstruction (ASIR), and model-based iterative reconstruction (MBIR) with standard of care FBP images. SUBJECTS AND METHODS: Fifty patients (33 men and 17 women; mean age [± SD], 62 ± 10 years) undergoing routine chest CT gave written informed consent for acquisition of an additional submillisievert chest CT series with reduced tube current but identical scanning length as standard of care chest CT. Sinogram data of the submillisievert series were reconstructed with FBP, SafeCT, ASIR, and MBIR and compared with FBP images at standard-dose chest CT (n = 8 × 50 = 400 series). Two thoracic radiologists performed independent comparison for visualization of lesion margin, visibility of small structures, and diagnostic acceptability. Objective noise measurements and noise spectral density were obtained. RESULTS: Of 287 detected lesions, 162 were less than 1-cm noncalcified nodules. Lesion margins were well seen on all submillisievert reconstruction images except MBIR, on which they were poorly visualized. Likewise, only submillisievert MBIR images were suboptimal for visibility of normal structures, such as pulmonary vessels in the outer 2 cm of the lung, interlobular fissures, and subsegmental bronchial walls. MBIR had the lowest image noise compared with other techniques. CONCLUSION: FBP, SafeCT, ASIR, and MBIR can enable optimal lesion evaluation on chest CT acquired at a volume CT dose index of 2 mGy. However, all submillisievert reconstruction techniques were suboptimal for visualization of mediastinal structures. Submillisievert MBIR images were suboptimal for visibility of normal lung structures despite showing lower image noise.


Asunto(s)
Algoritmos , Dosis de Radiación , Protección Radiológica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Torácica/métodos , Radiometría , Tomografía Computarizada por Rayos X/métodos , Humanos , Persona de Mediana Edad , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
Am J Ther ; 21(3): e71-4, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-23803980

RESUMEN

Dabigatran etexilate mesylate, a direct thrombin inhibitor, has been approved in the United States as an alternative to warfarin for the prevention of stroke and systemic thromboembolism in patients with nonvalvular atrial fibrillation. The authors report 2 cases of development of large left atrial thrombi and unfortunate occurrence of thromboembolic events in patients with chronic atrial fibrillation, despite these patients being compliant with recommended dabigatran therapy. The authors postulate that certain unique pharmacologic characteristics of the drug may be disadvantageous toward providing a therapeutic level of anticoagulation in all patients and may provide an explanation of occurrence of these thrombotic events, namely, (1) a competitive, reversible, and incomplete inhibition of only one coagulation factor (thrombin), as opposed to warfarin that leads to noncompetitive inhibition of multiple coagulation factors, (2) a short half-life (12-17 hours) and linear pharmacodynamics related to drug levels that conceivably causes an hourly variation of the level of anticoagulation, (3) a much lower incidence of supratherapeutic anticoagulation ("overshoot") with dabigatran as compared with warfarin, and (4) a reported increase in the coagulation factors that follows long-term use of dabigatran. Also, the absence of routine monitoring to test the therapeutic efficacy of the drug prevents diagnosis of cases where anticoagulation remains subtherapeutic. These factors could explain occurrence of the thrombotic and thromboembolic events in our cases.


Asunto(s)
Bencimidazoles/efectos adversos , Inhibidores del Factor Xa/efectos adversos , Piridinas/efectos adversos , Tromboembolia/inducido químicamente , Trombosis/inducido químicamente , Anciano , Fibrilación Atrial/tratamiento farmacológico , Bencimidazoles/uso terapéutico , Dabigatrán , Monitoreo de Drogas/métodos , Inhibidores del Factor Xa/uso terapéutico , Atrios Cardíacos/patología , Humanos , Masculino , Persona de Mediana Edad , Piridinas/uso terapéutico , Tromboembolia/patología , Trombosis/patología
17.
Am J Ther ; 21(4): e100-5, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24513697

RESUMEN

The authors describe 2 cases of extensive intracoronary thrombus formation leading to acute closure of the left main where bivalirudin (Angiomax) was used as the anticoagulant during percutaneous coronary intervention leading to mortality. Both cases had similarity in the cascade of complications of coronary dissection leading to slow flow and prolonged procedure time with compromise of antegrade flow in the coronary artery and a final catastrophic development of extensive intracoronary thrombosis extending into the left main and nonintervened vessel (left anterior descending or circumflex) followed by ventricular fibrillation and death. Bivalirudin has reversible anticoagulant pharmacodynamics because the bivalirudin molecule is cleaved by the thrombin molecule. In situations when the antegrade flow is compromised, delivery of fresh circulating bivalirudin to replenish the catalysis of bivalirudin by thrombin is diminished, allowing thrombin activity to regenerate, thereby creating a prothrombotic milieu in these coronary segments. This can lead to extensive intracoronary thrombus formation in situations of slow flow precipitated by coronary dissection and prolonged dwell time with intracoronary hardware (wires, balloons, and stents). Interventionalists should be aware of the potential risk of this fatal complication and should be proactive in recognizing the scenarios where this is likely to occur. In such anticipated circumstances, the interventionalist may judiciously switch the anticoagulant to heparin and/or use additional glycoprotein IIb/IIIa inhibitor because freshly formed intracoronary thrombus is susceptible to lysis by glycoprotein IIb/IIIa inhibitors.


Asunto(s)
Anticoagulantes/uso terapéutico , Trombosis Coronaria/etiología , Fragmentos de Péptidos/uso terapéutico , Intervención Coronaria Percutánea/métodos , Anciano , Anticoagulantes/efectos adversos , Antitrombinas/efectos adversos , Antitrombinas/uso terapéutico , Trombosis Coronaria/patología , Resultado Fatal , Hirudinas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Fragmentos de Péptidos/efectos adversos , Proteínas Recombinantes/efectos adversos , Proteínas Recombinantes/uso terapéutico , Trombina/metabolismo , Factores de Tiempo
18.
J Comput Assist Tomogr ; 38(2): 293-8, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24632938

RESUMEN

PURPOSE: To evaluate the effect of localizing radiograph on computed tomography (CT) radiation dose associated with automatic exposure control with a human cadaver and patient study. MATERIALS AND METHODS: Institutional review board approved the study with a waiver of informed consent. Two chest CT image series with fixed tube current and combined longitudinal-angular automatic exposure control (AEC) were acquired in a human cadaver (64-year-old man) after each of the 8 combinations of localizer radiographs (anteroposterior [AP], AP lateral, AP-posteroanterior [PA], lateral AP, lateral PA, PA, PA-AP, and PA lateral). Applied effective milliampere second, volume CT dose index (CTDIvol) and image noise were recorded for all 24-image series. Volume CT dose indexes were also recorded in 20 patients undergoing chest and abdominal CT after PA and PA-lateral radiographs with the use of AEC. Data were analyzed using analysis of variance and linear correlation tests. RESULTS: With AEC, the CTDIvol fluctuates with the number and projection of localizer radiographs (P < 0.0001). Lowest CTDIvol values are seen when 2 orthogonal localizer radiographs are acquired, whereas highest values are seen when single PA or AP-PA projection localizer radiographs are acquired for planning (P < 0.0001). In 20 patients, CT scanning with AEC after acquisition of 2 orthogonal projection localizer radiographs was associated with significant reduction in radiation dose compared to PA projection radiographs alone (P < 0.0001). CONCLUSIONS: When scanning with AEC, acquisition of 2 orthogonal localizer radiographs is associated with lower CTDIvol compared to a single localizer radiograph.


Asunto(s)
Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Cadáver , Femenino , Humanos , Masculino , Persona de Mediana Edad , Protección Radiológica/métodos
19.
J Comput Assist Tomogr ; 38(5): 760-7, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24834892

RESUMEN

PURPOSE: The purpose of this study was to assess pulmonary lesion detection, diagnostic confidence, and noise reduction in sparse-sampled (SpS) computed tomographic (CT) data of submillisievert (SubmSv) chest CT reconstructed with iterative reconstruction technique (IRT). MATERIALS AND METHODS: This Human Insurance Portability and Accountability-compliant, institutional review board-approved prospective study was performed using SpS-SubmSv IRT chest CT in 10 non-obese patients (body-mass index, 21-35 kg/m; age range, 26-90 years). Written informed consent was obtained. The patients were scanned at standard-dose CT (mean [SD] volumetric CT dose index, 6 [0.9] mGy; mean [SD] dose-length product, 208 ± 44 mGy·cm; and mean [SD] effective dose, 3 [0.6] mSv) and at SubmSv dose (1.8 [0.2] mGy, 67 [2] mGy·cm, 0.9 [0.03] mSv, respectively) on a Philips 128-slice CT scanner with double z-sampling. Sparse angular sampling data were reconstructed using 25% of the angular projections from the SubmSv sinogram to reduce the number of views and radiation dose by approximately 4-fold. Hence, the patients were scanned and then, simulation-based sparse sampling was performed with a resultant dose hypothetical SpS scan estimated mathematically (0.2 mSv). From each patient data, 3 digital imaging and communications in medicine series were generated: SpS-SubmSv with IRT, fully sampled SubmSv filtered back projection (FBP), and fully sampled standard-dose FBP (SD-FBP). Two radiologists independently assessed these image series for detection of lung lesions, visibility of small structures, and diagnostic acceptability. Objective noise was measured in the thoracic aorta, and noise spectral density was obtained for SpS-SubmSv IRT, SubmSv-FBP, and SD-FBP. RESULTS: The SpS-SubmSv IRT resulted in 75% (0.2/0.9 mSv) and 92% (0.2/2.9 mSv) dose reduction, when compared with the fully sampled SubmSv-FBP and SD-FBP, respectively. Images of SpS-SubmSv displayed all 46 lesions (most <1 cm, 30 lung nodules, 7 ground glass opacities, 9 emphysema) seen on the SubmSv-FBP and SD-FBP data sets. Lesion margins with sparse-sampled data were deemed acceptable compared with both SubmSv-FBP and SD-FBP. Overall diagnostic confidence was maintained with SpS-SubmSv IRT despite the presence of minor pixilation artifacts in 3 of 10 cases. The SpS-SubmSv IRT showed 63% and 38% noise reduction when compared with SubmSv-FBP (P < 0.0001) and SD-FBP (P < 0.01), respectively, with no significant change in Hounsfield unit values (P > 0.05). Noise-spectral density showed that SpS-SubmSv IRT gives a linear decrease over frequency in the semilog plot and an exponential decrease of noise power over frequency compared with SubmSv-FBP and SD-FBP. CONCLUSIONS: More than 90% dose reduction could be achieved with one-fourth sparse-sampled and SubmSv chest CT examination when reconstructed with IRT. Chest CT dose at one fourth of a millisievert with SpS is possible with optimal lesion detection and diagnostic confidence for the evaluation of pulmonary findings.


Asunto(s)
Compresión de Datos/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Dosis de Radiación , Protección Radiológica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Abdominal/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Método Doble Ciego , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
20.
J Comput Assist Tomogr ; 38(4): 613-9, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24651746

RESUMEN

PURPOSE: To assess lesion detection and diagnostic confidence of computed tomography (CT) of the chest performed at less than 1 mSv with 2 iterative reconstruction (IR) techniques. MATERIALS AND METHODS: Ten patients gave written informed consent for the acquisitions of images at submillisievert dose (0.9 mSv), in addition to clinical standard-dose (SD) chest CT (2.9 mSv). Submillisievert images were reconstructed with iDose and iterative model reconstruction (IMR). Two radiologists assessed lesion detection, margins, diagnostic confidence, and visibility of small structures. Objective noise and noise spectral density were measured. RESULTS: Lesion detection was identical for standard-dose filtered back projection (FBP), submSv iDose, and submSv IMR. Lesion margins were better seen for 30% of detected lung lesions with submSv IMR compared to standard-dose FBP and submSv iDose (P < 0.05). Visibility of abdominal structures, and diagnostic confidence with submSv iDose and submSv IMR were similar to standard-dose FBP. There was 21% to 64% noise reduction with submSv IMR and 1% to 15% higher noise with iDose compared to standard-dose FBP (P < 0.0001). CONCLUSIONS: Submillisievert IMR improves delineation of lesion margins compared to standard-dose FBP and submSv iDose.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Pulmón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Prospectivos , Método Simple Ciego
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA