Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Phys Rev Lett ; 132(10): 101006, 2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38518351

RESUMEN

Dark matter (DM) particles with sufficiently large cross sections may scatter as they travel through Earth's bulk. The corresponding changes in the DM flux give rise to a characteristic daily modulation signal in detectors sensitive to DM-electron interactions. Here, we report results obtained from the first underground operation of the DAMIC-M prototype detector searching for such a signal from DM with MeV-scale mass. A model-independent analysis finds no modulation in the rate of 1 e^{-} events with sidereal period, where a DM signal would appear. We then use these data to place exclusion limits on DM in the mass range [0.53,2.7] MeV/c^{2} interacting with electrons via a dark photon mediator. Taking advantage of the time-dependent signal we improve by ∼2 orders of magnitude on our previous limit obtained from the total rate of 1 e^{-} events, using the same dataset. This daily modulation search represents the current strongest limit on DM-electron scattering via ultralight mediators for DM masses around 1 MeV/c^{2}.

2.
Phys Rev Lett ; 130(17): 171003, 2023 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-37172255

RESUMEN

We report constraints on sub-GeV dark matter particles interacting with electrons from the first underground operation of DAMIC-M detectors. The search is performed with an integrated exposure of 85.23 g days, and exploits the subelectron charge resolution and low level of dark current of DAMIC-M charge-coupled devices (CCDs). Dark-matter-induced ionization signals above the detector dark current are searched for in CCD pixels with charge up to 7e^{-}. With this dataset we place limits on dark matter particles of mass between 0.53 and 1000 MeV/c^{2}, excluding unexplored regions of parameter space in the mass ranges [1.6,1000] MeV/c^{2} and [1.5,15.1] MeV/c^{2} for ultralight and heavy mediator interactions, respectively.

3.
Phys Rev Lett ; 125(24): 241803, 2020 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-33412014

RESUMEN

We present constraints on the existence of weakly interacting massive particles (WIMPs) from an 11 kg d target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of ionization events with electron-equivalent energies >200 eV_{ee} in the DAMIC CCDs are consistent with backgrounds from natural radioactivity. An excess of ionization events is observed above the analysis threshold of 50 eV_{ee}. While the origin of this low-energy excess requires further investigation, our data exclude spin-independent WIMP-nucleon scattering cross sections σ_{χ-n} as low as 3×10^{-41} cm^{2} for WIMPs with masses m_{χ} from 7 to 10 GeV c^{-2}. These results are the strongest constraints from a silicon target on the existence of WIMPs with m_{χ}<9 GeV c^{-2} and are directly relevant to any dark matter interpretation of the excess of nuclear-recoil events observed by the CDMS silicon experiment in 2013.

4.
Phys Rev Lett ; 123(18): 181802, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31763884

RESUMEN

We report direct-detection constraints on light dark matter particles interacting with electrons. The results are based on a method that exploits the extremely low levels of leakage current of the DAMIC detector at SNOLAB of 2-6×10^{-22} A cm^{-2}. We evaluate the charge distribution of pixels that collect <10e^{-} for contributions beyond the leakage current that may be attributed to dark matter interactions. Constraints are placed on so-far unexplored parameter space for dark matter masses between 0.6 and 100 MeV c^{-2}. We also present new constraints on hidden-photon dark matter with masses in the range 1.2-30 eV c^{-2}.

5.
Phys Rev Lett ; 113(22): 221101, 2014 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-25494064

RESUMEN

We report the first direct measurement of the overall characteristics of microwave radio emission from extensive air showers. Using a trigger provided by the KASCADE-Grande air shower array, the signals of the microwave antennas of the Cosmic-Ray Observation via Microwave Emission experiment have been read out and searched for signatures of radio emission by high-energy air showers in the GHz frequency range. Microwave signals have been detected for more than 30 showers with energies above 3×10^{16} eV. The observations presented in this Letter are consistent with a mainly forward-directed and polarized emission process in the GHz frequency range. The measurements show that microwave radiation offers a new means of studying air showers at E≥10^{17} eV.

6.
J Fr Ophtalmol ; 18(6-7): 475-80, 1995.
Artículo en Francés | MEDLINE | ID: mdl-7560790

RESUMEN

Colobomatous orbital cyst with microphthalmos is an anomaly of the orbital contents occurring during embryogenesis. In this study, we report the case of a 3 year-old child referred with the initial diagnosis of voluminous orbital angioma. Radiological investigations and histological study of the ablated mass established the correct diagnosis of colobomatous cyst. Pathogeny, diagnostic and therapeutic problems are discussed.


Asunto(s)
Coloboma/diagnóstico , Microftalmía , Órbita/anomalías , Preescolar , Coloboma/patología , Coloboma/cirugía , Quistes/patología , Quistes/cirugía , Humanos , Masculino , Microftalmía/cirugía
8.
Ann Chir Plast Esthet ; 38(4): 445-50, 1993 Aug.
Artículo en Francés | MEDLINE | ID: mdl-7779174

RESUMEN

Lubboc (T650) is a bovine heterologous bone implant obtained by specific preparation of trabecular of bone. In vitro and in vivo biocompatibility studies have revealed the absence of any cytotoxicity or systemic toxicity. Lubboc has many fields of application, including all bone graft surgical indications. We report our first results concerning the use of this product in orbital surgery either as a filling or contention material or as an apposition material. On all 20 operated patients we did not encounter any intolerance, inflammation or infection. The follow-up is still too short to appreciate the long term integration of this material which has the advantage of being a substitute for autologous bone, avoiding bone graft harvesting.


Asunto(s)
Materiales Biocompatibles/uso terapéutico , Trasplante Óseo/métodos , Órbita/cirugía , Adolescente , Adulto , Anciano , Animales , Huesos , Bovinos , Niño , Preescolar , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fracturas Orbitales/cirugía , Cirugía Plástica/métodos , Trasplante Heterólogo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA