Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Am J Orthod Dentofacial Orthop ; 146(3): 319-27, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25172254

RESUMEN

INTRODUCTION: The aim was to study nickel-titanium closed-coil springs in a clinically relevant test setting with respect to the accuracy of the "preactivation" for nickel-titanium closed-coil springs application and whether it is possible to keep activation forces constant during the whole time of treatment. METHODS: We tested 10 types of springs from 5 manufacturers under clinically relevant conditions, allowing us to study the interactions between load and temperature over time. Hystereses were compared using t tests. RESULTS: Springs with a large mechanical hysteresis also showed a large thermal hysteresis. After heating shock, these springs showed intensive force spikes and persistent high loads. Some springs showed negligible thermal and mechanical hysteresis. Such springs never showed any clinically significant persistent high loads. CONCLUSIONS: Springs with a large hysteresis were unable to keep activation forces constant during the whole time of treatment even after any preactivation, and they might cause persistently high loads and possibly overloading. Only springs with minor hysteresis, low temperature dependence of force, and a clinically useful plateau have the following clinical advantages: reduced chair time, optimal rates of tooth movement, reproducible clinical results, and conservation of anchorage.


Asunto(s)
Aleaciones Dentales/química , Níquel/química , Alambres para Ortodoncia , Titanio/química , Frío , Análisis del Estrés Dental/instrumentación , Elasticidad , Calor , Humanos , Ensayo de Materiales , Fenómenos Mecánicos , Estrés Mecánico , Termodinámica , Torsión Mecánica
2.
Acta Medica (Hradec Kralove) ; 56(2): 41-6, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24069656

RESUMEN

INTRODUCTION: The aim of this study was to find out the impact of degradation and regeneration of force over time at NiTi springs on the value and course of the final acting force and to verify the possibility of using these phenomena for a directed transition to the reverse plateau and its maintaining. METHODS: Static and cyclic mechanical loadings were performed. At first unused springs were tested. Afterwards the springs were mechanically stabilized by stress cycling and finally tested again. The difference in shape of the working curves was assessed. For simulation and description of the force degradation the modified Voight model was used. RESULTS: New springs, mainly those with large hysteresis, showed a significant stress-strain curve movement and shape changes during the cycling. The effect of the stress-strain curve course change disappeared fully in the stabilized springs. Multiple loading led to an overall decrease of force value during the measurement. The effect of force degradation and regeneration over time by simple static loading varies in the range of percentage of the nominal force in the plateau area. The transition between stress-strain curve phases caused by the degradation or regeneration of the force wasn't observed in case of mechanically stabilized springs. CONCLUSIONS: Springs should be mechanically stabilized before their application. The degree of force degradation over time is insignificant for mechanically stabilized springs. Degradation or regeneration of force over time, mechanical stabilization or micromovements in the mouth don't cause any transition between individual stress-strain curve phases.


Asunto(s)
Elasticidad , Níquel , Aparatos Ortodóncicos , Titanio , Viscosidad , Fuerza Compresiva , Humanos , Ensayo de Materiales , Resistencia a la Tracción , Factores de Tiempo
3.
Acta Medica (Hradec Kralove) ; 65(2): 59-65, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36458933

RESUMEN

Due to a broad spectrum of endodontic rotary instruments on the market and no standardised protocol for comparing their mechanical properties, it can be challenging for clinician to choose proper instruments. In vitro studies using resin blocks with artificial canals can offer many valuable information because of their uniformity compared to studies performed on extracted teeth. To improve precision and reproducibility of artificial canals, 3D printing was used in this study to manufacture endodontic test block samples. 20 commercially available endodontic blocks Endo-Training-Bloc-J by Dentsply Sirona were tested. The mean values of the measured parameters were used for a 3D CAD model of their replicas. 20 copies of the endodontic training blocks were printed from acrylic resin (VeroClear-RGD810, Stratasys, Eden Prairie, USA) using the 3D printer Objet30 Pro (Stratasys, Eden Prairie, USA). The key dimensions of the commercial blocks and the 3D printed blocks were measured under and compared using t - test and Levene's test for equality of variances. The profiles of the 3D printed artificial canals showed significantly lower dimensional variability when compared with the commercial blocks. 3D polyjet printing proved to be a precise and reproducible method for production of blocks for testing endodontic rotary instruments.


Asunto(s)
Endometriosis , Proyectos de Investigación , Femenino , Humanos , Reproducibilidad de los Resultados , Impresión Tridimensional , Extracción Dental
4.
PLoS One ; 15(7): e0235842, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32639989

RESUMEN

Biodegradable stents are promising treatments for many diseases, e.g., coronary artery disease, urethral diseases, tracheal diseases, and esophageal strictures. The mechanical properties of biodegradable stent materials play a key role in the safety and efficacy of treatment. In particular, insufficient creep resistance of the stent material could result in premature stent collapse or narrowing. Commercially available biodegradable self-expandable SX-ELLA stents made of polydioxanone monofilament were tested. A new, simple, and affordable method to measure the shear modulus of tiny viscoelastic wires is presented. The important mechanical parameters of the polydioxanone filament were obtained: the median Young's modulus was [Formula: see text] = 958 (922, 974) MPa and the shear modulus was [Formula: see text] = 357 (185, 387) MPa, resulting in a Poisson's ratio of ν = 0.34. The SX-ELLA stents exhibited significant force relaxation due to the stress relaxation of the polydioxanone monofilament, approximately 19% and 36% 10 min and 48 h after stent application, respectively. However, these results were expected, and the manufacturer and implanting clinician should be aware of the known behavior of these biodegradable materials. If possible, a biodegradable stent should be designed considering therapeutic force rather than initial force. Additionally, new and more advanced biodegradable shape-memory polymers should be considered for future study and use.


Asunto(s)
Implantes Absorbibles , Materiales Biocompatibles/química , Polidioxanona/química , Stents , Módulo de Elasticidad , Humanos , Ensayo de Materiales , Fenómenos Mecánicos , Diseño de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA