Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 389(25): 2319-2330, 2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-38015442

RESUMEN

BACKGROUND: Percutaneous coronary intervention (PCI) is frequently performed to reduce the symptoms of stable angina. Whether PCI relieves angina more than a placebo procedure in patients who are not receiving antianginal medication remains unknown. METHODS: We conducted a double-blind, randomized, placebo-controlled trial of PCI in patients with stable angina. Patients stopped all antianginal medications and underwent a 2-week symptom assessment phase before randomization. Patients were then randomly assigned in a 1:1 ratio to undergo PCI or a placebo procedure and were followed for 12 weeks. The primary end point was the angina symptom score, which was calculated daily on the basis of the number of angina episodes that occurred on a given day, the number of antianginal medications prescribed on that day, and clinical events, including the occurrence of unblinding owing to unacceptable angina or acute coronary syndrome or death. Scores range from 0 to 79, with higher scores indicating worse health status with respect to angina. RESULTS: A total of 301 patients underwent randomization: 151 to the PCI group and 150 to the placebo group. The mean (±SD) age was 64±9 years, and 79% were men. Ischemia was present in one cardiac territory in 242 patients (80%), in two territories in 52 patients (17%), and in three territories in 7 patients (2%). In the target vessels, the median fractional flow reserve was 0.63 (interquartile range, 0.49 to 0.75), and the median instantaneous wave-free ratio was 0.78 (interquartile range, 0.55 to 0.87). At the 12-week follow-up, the mean angina symptom score was 2.9 in the PCI group and 5.6 in the placebo group (odds ratio, 2.21; 95% confidence interval, 1.41 to 3.47; P<0.001). One patient in the placebo group had unacceptable angina leading to unblinding. Acute coronary syndromes occurred in 4 patients in the PCI group and in 6 patients in the placebo group. CONCLUSIONS: Among patients with stable angina who were receiving little or no antianginal medication and had objective evidence of ischemia, PCI resulted in a lower angina symptom score than a placebo procedure, indicating a better health status with respect to angina. (Funded by the National Institute for Health and Care Research Imperial Biomedical Research Centre and others; ORBITA-2 ClinicalTrials.gov number, NCT03742050.).


Asunto(s)
Angina Estable , Intervención Coronaria Percutánea , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Síndrome Coronario Agudo , Angina Estable/tratamiento farmacológico , Angina Estable/cirugía , Fármacos Cardiovasculares/uso terapéutico , Reserva del Flujo Fraccional Miocárdico , Estado de Salud , Intervención Coronaria Percutánea/métodos , Resultado del Tratamiento , Método Doble Ciego , Isquemia Miocárdica
2.
Europace ; 2024 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-39344253

RESUMEN

BACKGROUND AND AIMS: Reduction of atrial fibrillation (AF) burden is the preferred outcome measure over categorical AF rhythm recurrence after AF ablation. In this sub-analysis of the TeleCheck-AF project we tested the feasibility of smartphone app-based approximation of time spent with AF and/or symptoms. METHODS: Patients scheduled for at least one teleconsultation during the 12-month follow-up after AF ablation were instructed to use a smartphone photoplethysmography (PPG)-based application for simultaneous symptom and rhythm monitoring 3-times daily for 1 week. Proxies of time spent with AF and/or symptoms (%-recordings, load, %-days), temporal aggregation of AF and/or symptoms (density), and symptom-rhythm correlation (SRC) were assessed. RESULTS: In total 484 patients (60% male, 62±9.9 years) were included. Adherence, motivation and patient satisfaction were high. %AF-recordings, AF load and %AF-days (rs= 0.88-0.95) and %symptom-recordings, symptom load, %symptom-days (rs= 0.95-0.98) showed positive correlations. The SRC correlated negatively with time spent with symptoms (rs=-0.65--0.90) and with time spent with AF (rs=-0.31--0.34). In patients with paroxysmal AF before ablation and AF during the monitoring period, 87% (n=39/44) had a low-density score <50% ("paroxysmal AF pattern") while 5% (n=2/44) had a high-density score >90% ("persistent AF pattern"). Corresponding numbers for patients with persistent AF before ablation were 48% (n=11/23) and 43% (n=10/23), respectively. CONCLUSIONS: On-demand, app-based simultaneous rhythm and symptom assessment provides objective proxies of time spent with AF and/or symptoms and symptom-rhythm correlation, which may assist in assessing AF and symptom outcomes after AF ablation.

3.
J Cardiovasc Electrophysiol ; 34(12): 2552-2562, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37962263

RESUMEN

BACKGROUND: Patients with atrial fibrillation (AF) and likelihood of bleeding can undergo left atrial appendage occlusion (LAAO) as an alternative method of stroke prophylaxis. Short-term anti-thrombotic drugs are used postprocedure to offset the risk of device-related thrombus, evidence for this practice is limited. OBJECTIVES: To investigate optimal postimplant antithrombotic strategy in high bleeding-risk patients. METHODS: Patients with AF and high-risk for both stroke and bleeding undergoing LAAO were advised their perioperative drug therapy by a multidisciplinary physician panel. Those deemed to be at higher risk of bleeding from anti-thrombotic drugs were assigned to minimal treatment with no antithrombotics or Aspirin-alone. The remaining patients received standard care (STG) with a 12 week course of dual-antiplatelets or anticoagulation postimplant. We compared mortality, device-related thrombus, ischemic stroke, and bleeding events during the 90 days postimplant and long-term. Event-free survival was assessed using Kaplan-Meier survival analysis, with logrank testing for statistical significance. RESULTS: Seventy-five patients underwent LAAO of whom 63 patients (84%) had a prior serious bleeding event. The 42 patients on minimal treatment were older (74.3 ± 7.7 vs. 71.2 ± 7.2) with higher HASBLED score (3.6 ± 0.9 vs. 3.3 ± 1.2) than the 33 patients having standard care. There were no device-related thrombi or strokes in either group at 90 days postprocedure; STG had more bleeding events (5/33 vs. 0/42, p = 0.01) with associated deaths (3/33 vs. 0/42, p = 0.05). During long-term follow-up (median 2.2 years), all patients transitioned onto no antithrombotic drugs (43 patients [61%]) or a single-antiplatelet (29 patients [39%]). There was no evidence of early minimal treatment adversely affecting long-term outcomes. CONCLUSIONS: Short-term anti-thrombotic drugs may not be needed after LAAO implant in patients with high bleeding risk and could be harmful. Larger, prospective studies would be warranted to test these findings.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Trombosis , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Apéndice Atrial/cirugía , Estudios Prospectivos , Susceptibilidad a Enfermedades/complicaciones , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Hemorragia/inducido químicamente , Resultado del Tratamiento , Anticoagulantes/efectos adversos
4.
J Cardiovasc Electrophysiol ; 34(6): 1431-1440, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36786511

RESUMEN

INTRODUCTION: It is not known whether the optimal atrioventricular (AVopt ) delay varies between left ventricular (LV) pacing site during endocardial biventricular pacing (BiVP) and may therefore needs consideration. METHODS: We assessed the hemodynamic AVopt in patients with chronic heart failure undergoing endocardial LV lead implantation. AVopt was assessed during atrio-BiVP with a "roving LV lead." Up to four locations were studied: mid-lateral wall, mid-septum (or a close alternative), site of greatest hemodynamic improvement, and LV lead implant site. The AVopt was compared to a fixed AV delay of 180 ms. RESULTS: Seventeen patients were included (12 male, aged 66.5 ± 12.8 years, ejection fraction 26 ± 7%, 16 left bundle branch block or high percentage of right ventricular pacing [RVP], QRS duration 167 ± 27 ms). In most locations (62/63), AVopt increased systolic blood pressure during BiVP compared with RVP (relative improvement 6 mmHg, interquartile range [IQR] 4-9 mmHg). Compared to a fixed AV delay, the hemodynamic improvement at AVopt was higher (1 mmHg, IQR 0.2-2.6 mmHg, p < .001). Within most patients (16/17), we observed a difference in AVopt between pacing sites (median paced AVopt 209 ms, IQR 117-250). Within this range, the hemodynamic impact of these differences was small (median loss 0.6 mmHg, IQR 0.1-2.6 mmHg). CONCLUSION: Within a patient, different endocardial LV lead locations have slightly different hemodynamic AVopt which are superior to a fixed AV delay. The hemodynamic consequence of applying an optimum from a different lead location is small.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Masculino , Terapia de Resincronización Cardíaca/efectos adversos , Hemodinámica/fisiología , Bloqueo de Rama , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos , Función Ventricular Izquierda/fisiología , Estimulación Cardíaca Artificial
5.
Europace ; 24(9): 1420-1429, 2022 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-35737685

RESUMEN

AIM: Evaluate the novel PolarX Cryoballoon in atrial fibrillation (AF) catheter ablation through a propensity-matched comparison with the Arctic Front Advance (AFA). The aim was also to identify cryoablation metrics that are predictive of successful pulmonary vein isolation (PVI) with the PolarX Cryoballoon. METHODS AND RESULTS: This prospective multi-centre study included patients that underwent cryoablation for AF. All patients underwent PVI with reconnection assessed after a 30-min waiting period and adenosine. Safety, efficacy, and cryoablation metrics were compared between PolarX and a propensity-matched AFA cohort. Seventy patients were included with 278 veins treated. In total, 359 cryoablations were performed (1.3 ± 0.6 per vein) to achieve initial PVI with 205 (73.7%) veins isolating with a single cryoablation. Independent predictors for achieving initial PVI included temperature at 30 s [odds ratio (OR) 1.26; P = 0.003] and time to reach -40°C (OR 1.88; P < 0.001) with an optimal cut-off of ≤-38.5°C at 30 s [area under the curve (AUC) 0.79; P < 0.001] and ≤-40°C at ≤32.5 s (AUC 0.77; P < 0.001), respectively. Of the 278 veins, 46 (16.5%) veins showed acute reconnection. Temperature at 30 s (≤-39.5°C, OR 1.24; P = 0.002), nadir temperature (≤-53.5°C, OR 1.35; P = 0.003), and time to isolation (≤38.0 s, OR 1.18; P = 0.009) were independent predictors of sustained PVI. Combining two of these three targets was associated with reconnection in only 2-5% of PVs. Efficacy and safety of the PolarX Cryoballoon were comparable to AFA Cryoballoon, however, cryoablation metrics were significantly different. CONCLUSIONS: The PolarX Cryoballoon has a different cryoablation profile to AFA Cryoballoon. Prospective testing of these proposed targets in large outcomes studies is required.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Adenosina , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Benchmarking , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Humanos , Estudios Prospectivos , Venas Pulmonares/cirugía , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
6.
Europace ; 23(7): 1003-1015, 2021 07 18.
Artículo en Inglés | MEDLINE | ID: mdl-33822029

RESUMEN

AIMS: TeleCheck-AF is a multicentre international project initiated to maintain care delivery for patients with atrial fibrillation (AF) during COVID-19 through teleconsultations supported by an on-demand photoplethysmography-based heart rate and rhythm monitoring app (FibriCheck®). We describe the characteristics, inclusion rates, and experiences from participating centres according the TeleCheck-AF infrastructure as well as characteristics and experiences from recruited patients. METHODS AND RESULTS: Three surveys exploring centre characteristics (n = 25), centre experiences (n = 23), and patient experiences (n = 826) were completed. Self-reported patient characteristics were obtained from the app. Most centres were academic (64%) and specialized public cardiology/district hospitals (36%). Majority of the centres had AF outpatient clinics (64%) and only 36% had AF ablation clinics. The time required to start patient inclusion and total number of included patients in the project was comparable for centres experienced (56%) or inexperienced in mHealth use. Within 28 weeks, 1930 AF patients were recruited, mainly for remote AF control (31% of patients) and AF ablation follow-up (42%). Average inclusion rate was highest during the lockdown restrictions and reached a steady state at a lower level after easing the restrictions (188 vs. 52 weekly recruited patients). Majority (>80%) of the centres reported no problems during the implementation of the TeleCheck-AF approach. Recruited patients [median age 64 (55-71), 62% male] agreed that the FibriCheck® app was easy to use (94%). CONCLUSION: Despite different health care settings and mobile health experiences, the TeleCheck-AF approach could be set up within an extremely short time and easily used in different European centres during COVID-19.


Asunto(s)
Fibrilación Atrial , COVID-19 , Aplicaciones Móviles , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Control de Enfermedades Transmisibles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pandemias , Evaluación del Resultado de la Atención al Paciente , SARS-CoV-2
7.
Europace ; 21(8): 1176-1184, 2019 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-31071213

RESUMEN

AIMS: Ablation of persistent atrial fibrillation (PsAF) has been performed by many techniques with varying success rates. This may be due to ablation techniques, patient demographics, comorbidities, and trial design. We conducted a meta-regression of studies of PsAF ablation to elucidate the factors affecting atrial fibrillation (AF) recurrence. METHODS AND RESULTS: Databases were searched for prospective studies of PsAF ablation. A meta-regression was performed. Fifty-eight studies (6767 patients) were included. Complex fractionated atrial electrogram (CFAE) ablation reduced freedom from AF by 8.9% [95% confidence interval (CI) -15 to -2.3, P = 0.009). Left atrial appendage [LAA isolation (three study arms)] increased freedom from AF by 39.5% (95% CI 9.1-78.4, P = 0.008). Posterior wall isolation (PWI) (eight study arms) increased freedom from AF by 19.4% (95% CI 3.3-38.1, P = 0.017). Linear ablation or ganglionated plexi ablation resulted in no significant effect on freedom from AF. More extensive ablation increased intraprocedural AF termination; however, intraprocedural AF termination was not associated with improved outcomes. Increased left atrial diameter was associated with a reduction in freedom from AF by 4% (95% CI -6.8% to -1.1%, P = 0.007) for every 1 mm increase in diameter. CONCLUSION: Linear ablation, PWI, and CFAE ablation improves intraprocedural AF termination, but such termination does not predict better long-term outcomes. Study arms including PWI or LAA isolation in the lesion set were associated with improved outcomes in terms of freedom from AF; however, further randomized trials are required before these can be routinely recommended. Left atrial size is the most important marker of AF chronicity influencing outcomes.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas/métodos , Efectos Adversos a Largo Plazo/epidemiología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Recurrencia , Análisis de Regresión , Medición de Riesgo/métodos , Resultado del Tratamiento
8.
Pacing Clin Electrophysiol ; 42(6): 754-757, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30659633

RESUMEN

An 85-year-old male was admitted to our center with a non-ST elevation myocardial infarction. The patient had a dual-chamber pacemaker in situ with an atrial and His lead. A transient increase in His threshold and loss of nonselective capture occurred at the presentation of right coronary artery infarction, peaking during rotational atherectomy therapy causing loss of capture and complete atrioventricular block. A follow-up interrogation, 2 weeks postrevascularization, showed a return to a normal nonselective capture morphology and threshold measurements. Physicians should be aware of this complication in patients with His leads, particularly those with a history of coronary artery disease.


Asunto(s)
Aterectomía , Fascículo Atrioventricular/fisiopatología , Electrodos Implantados/efectos adversos , Infarto del Miocardio sin Elevación del ST/cirugía , Marcapaso Artificial/efectos adversos , Anciano de 80 o más Años , Humanos , Masculino , Infarto del Miocardio sin Elevación del ST/fisiopatología
9.
J Cardiovasc Electrophysiol ; 29(11): 1471-1479, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30230101

RESUMEN

OBJECTIVE: We tested whether ablation methodology and study design can explain the varying outcomes in terms of atrial fibrillation (AF)-free survival at 1 year. BACKGROUND: There have been numerous paroxysmal AF ablation trials, which are heterogeneous in their use of different ablation techniques and study design. A useful approach to understanding how these factors influence outcome is to dismantle the trials into individual arms and reconstitute them as a large meta-regression. METHODS: Data were collected from 66 studies (6941 patients). With freedom from AF as the dependent variable, we performed meta-regression using the individual study arm as the unit. RESULTS: Success rates did not change regardless of the technique used to produce pulmonary vein isolation (PVI). Neither was adjunctive lesion sets associated with any improvement in outcome. Studies that included more males and fewer hypertensive patients were found more likely to report better outcomes. The electrocardiography method selected to assess outcome also plays an important role. Outcomes were worse in studies that used regular telemonitoring (by 23%; P < 0.001) or in patients who had implantable loop recorders (by 21%; P = 0.006), rather than those with the less thorough periodic Holter monitoring. CONCLUSIONS: Outcomes of AF ablation studies involving PVI are not affected by the technologies used to produce PVI. Neither do adjunctive lesion sets change the outcome. Achieving high success rates in these studies appears to be dependent more on patient mix and on the thoroughness of AF detection protocols. These should be carefully considered when quoting the success rates of AF ablation procedures that are derived from such studies.


Asunto(s)
Técnicas de Ablación/métodos , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto/métodos , Técnicas de Ablación/tendencias , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/mortalidad , Ablación por Catéter/tendencias , Humanos , Selección de Paciente , Tasa de Supervivencia/tendencias , Resultado del Tratamiento
10.
Eur Heart J ; 42(5): 365-367, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-33206954
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA