Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Lancet ; 378(9807): 1940-8, 2011 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-22075451

RESUMEN

BACKGROUND: The effectiveness of durable polymer drug-eluting stents comes at the expense of delayed arterial healing and subsequent late adverse events such as stent thrombosis (ST). We report the 4 year follow-up of an assessment of biodegradable polymer-based drug-eluting stents, which aim to improve safety by avoiding the persistent inflammatory stimulus of durable polymers. METHODS: We did a multicentre, assessor-masked, non-inferiority trial. Between Nov 27, 2006, and May 18, 2007, patients aged 18 years or older with coronary artery disease were randomly allocated with a computer-generated sequence to receive either biodegradable polymer biolimus-eluting stents (BES) or durable polymer sirolimus-eluting stents (SES; 1:1 ratio). The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation (TVR); patients were followed-up for 4 years. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00389220. FINDINGS: 1707 patients with 2472 lesions were randomly allocated to receive either biodegradable polymer BES (857 patients, 1257 lesions) or durable polymer SES (850 patients, 1215 lesions). At 4 years, biodegradable polymer BES were non-inferior to durable polymer SES for the primary endpoint: 160 (18·7%) patients versus 192 (22·6%) patients (rate ratios [RR] 0·81, 95% CI 0·66-1·00, p for non-inferiority <0·0001, p for superiority=0·050). The RR of definite ST was 0·62 (0·35-1·08, p=0·09), which was largely attributable to a lower risk of very late definite ST between years 1 and 4 in the BES group than in the SES group (RR 0·20, 95% CI 0·06-0·67, p=0·004). Conversely, the RR of definite ST during the first year was 0·99 (0·51-1·95; p=0·98) and the test for interaction between RR of definite ST and time was positive (p(interaction)=0·017). We recorded an interaction with time for events associated with ST but not for other events. For primary endpoint events associated with ST, the RR was 0·86 (0·41-1·80) during the first year and 0·17 (0·04-0·78) during subsequent years (p(interaction)=0·049). INTERPRETATION: Biodegradable polymer BES are non-inferior to durable polymer SES and, by reducing the risk of cardiac events associated with very late ST, might improve long-term clinical outcomes for up to 4 years compared with durable polymer SES. FUNDING: Biosensors Europe SA, Switzerland.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Polímeros , Sirolimus/análogos & derivados , Estudios de Seguimiento , Humanos , Trombosis/etiología
2.
JACC Cardiovasc Interv ; 6(8): 777-89, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23968698

RESUMEN

OBJECTIVES: This study sought to report the final 5 years follow-up of the landmark LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial. BACKGROUND: The LEADERS trial is the first randomized study to evaluate biodegradable polymer-based drug-eluting stents (DES) against durable polymer DES. METHODS: The LEADERS trial was a 10-center, assessor-blind, noninferiority, "all-comers" trial (N = 1,707). All patients were centrally randomized to treatment with either biodegradable polymer biolimus-eluting stents (BES) (n = 857) or durable polymer sirolimus-eluting stents (SES) (n = 850). The primary endpoint was a composite of cardiac death, myocardial infarction (MI), or clinically indicated target vessel revascularization within 9 months. Secondary endpoints included extending the primary endpoint to 5 years and stent thrombosis (ST) (Academic Research Consortium definition). Analysis was by intention to treat. RESULTS: At 5 years, the BES was noninferior to SES for the primary endpoint (186 [22.3%] vs. 216 [26.1%], rate ratio [RR]: 0.83 [95% confidence interval (CI): 0.68 to 1.02], p for noninferiority <0.0001, p for superiority = 0.069). The BES was associated with a significant reduction in the more comprehensive patient-orientated composite endpoint of all-cause death, any MI, and all-cause revascularization (297 [35.1%] vs. 339 [40.4%], RR: 0.84 [95% CI: 0.71 to 0.98], p for superiority = 0.023). A significant reduction in very late definite ST from 1 to 5 years was evident with the BES (n = 5 [0.7%] vs. n = 19 [2.5%], RR: 0.26 [95% CI: 0.10 to 0.68], p = 0.003), corresponding to a significant reduction in ST-associated clinical events (primary endpoint) over the same time period (n = 3 of 749 vs. n = 14 of 738, RR: 0.20 [95% CI: 0.06 to 0.71], p = 0.005). CONCLUSIONS: The safety benefit of the biodegradable polymer BES, compared with the durable polymer SES, was related to a significant reduction in very late ST (>1 year) and associated composite clinical outcomes. (Limus Eluted From A Durable Versus ERodable Stent Coating [LEADERS] trial; NCT00389220).


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Trombosis Coronaria/prevención & control , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Polímeros , Sirolimus/análogos & derivados , Anciano , Distribución de Chi-Cuadrado , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/diagnóstico , Trombosis Coronaria/etiología , Trombosis Coronaria/mortalidad , Europa (Continente) , Femenino , Humanos , Análisis de Intención de Tratar , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Infarto del Miocardio/prevención & control , Oportunidad Relativa , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Sirolimus/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento
3.
Z Kardiol ; 91 Suppl 3: 17-22, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12641011

RESUMEN

In-stent restenosis (ISR) represents the major limitation of stent implantation. Treatment, although of relative technical ease, is unsatisfactory due to the high incidence of recurrent restenosis. Long ISR lesions are especially prone to restenosis. Vascular brachytherapy (VBT) has emerged as a powerful adjunct therapeutic modality to treat ISR. However, VBT may be less effective in very long, diffuse ISR lesions. The present study investigated serial changes of the extent and distribution of neointima formation after beta-radiation as assessed by intravascular ultrasound (IVUS). Following interventional procedures of long ISR in 30 patients, a 40 mm or 60 mm non-centered 90Sr/90Y seed train was used for VBT. Serial (post radiation (PR) and follow-up (FU)) quantitative coronary angiography (QCA) measurements of minimal lumen diameter (MLD) and late lumen loss (LLL) and intravascular ultrasound measurements (IVUS) of cross-sectional areas of the lumen (L-CSA), stent (S-CSA) and intimal hyperplasia (IH-CSA) were performed and compared with historic controls. LLL (0.34 +/- 0.27 mm; p = 0.196), mean decrease of L-CSA (-1.0 +/- 0.8 mm2; p = 0.024) and mean increase of IH-CSA (0.5 +/- 1.3 mm2; p = 0.038) in long ISR were comparable with previously reported results of short ISR. In conclusion the average changes of lumen and intimal hyperplasia after beta-radiation of long ISR are similar to those of short ISR.


Asunto(s)
Angioplastia Coronaria con Balón , Braquiterapia , Reestenosis Coronaria/radioterapia , Stents , Ultrasonografía Intervencional , Adulto , Anciano , Anciano de 80 o más Años , Partículas beta , Ensayos Clínicos como Asunto , Angiografía Coronaria , Reestenosis Coronaria/patología , Reestenosis Coronaria/prevención & control , Interpretación Estadística de Datos , Método Doble Ciego , Femenino , Estudios de Seguimiento , Rayos gamma , Humanos , Hiperplasia , Masculino , Persona de Mediana Edad , Placebos , Dosificación Radioterapéutica , Recurrencia , Factores de Riesgo , Stents/efectos adversos , Factores de Tiempo , Túnica Íntima/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA