Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Am J Transplant ; 2024 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-39343037

RESUMEN

Kidneys donated after circulatory death (DCD) perform similarly to kidneys donated after brain death (DBD). However, the respective incidences of delayed graft function (DGF) differ. This questions the donor type-specific impact of early graft function on long-term outcomes. Using competing risk and Cox-regression analysis, we compared death-censored graft loss between types of early graft function: DGF (temporary dialysis dependency started within 7 days after transplantation), slow graft function (3-day plasma creatinine decline less than 10% per day), and immediate graft function. In 1061 DBD and 1605 DCD graft recipients (January 2014 until January 2023), graft survival was similar. DGF was associated with death-censored graft loss in DBD and DCD (adjusted hazard ratios: DGF in DBD: 1.79 [1.04-2.91], P = .027, DGF in DCD: 1.84 [1.18-2.87], P = .008; Reference: no DGF). Slow graft function was associated with death-censored graft loss in DBD, but not significantly in DCD (adjusted hazard ratios DBD: 2.82 (1.34-5.93), P = .007, and DCD: 1.54 (0.72-3.35), P = .262; Reference: immediate graft function). Early graft dysfunction has a differential impact on graft outcome in DBD and DCD. The differences between DBD and DCD should be accounted for in research and the clinic.

2.
Nephrol Dial Transplant ; 39(8): 1239-1247, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-38400561

RESUMEN

Through improved insights into the increasing incidence and detrimental effects of acute kidney injury (AKI), its clinical relevance has become more and more apparent. Although treatment strategies for AKI have also somewhat improved, an adequate remedy still does not exist. Finding one is complicated by a multifactorial pathophysiology and by heterogeneity in the patient population. Alkaline phosphatase (ALP) has been suggested as a therapy for sepsis-associated AKI because of its protective effects against lipopolysaccharide (LPS)-induced inflammation and kidney injury in animals. However, its effectiveness as an AKI treatment has not been demonstrated definitively. Because the anti-inflammatory properties of ALP are likely not reliant on a direct effect on LPS itself, we postulate that other pathways are much more important in explaining the renoprotective properties ascribed to ALP. The re-evaluation of which properties of the ALP enzyme are responsible for the benefit seen in the lab is an important step in determining where the true potential of ALP as a treatment strategy for AKI in the clinic lies. In this review we will discuss how ALP can prevent activation of harmful pro-inflammatory receptors, redirect cell-cell signalling and protect barrier tissues, which together form the basis for current knowledge of the role of ALP in the kidney. With this knowledge in mind and by analysing currently available clinical evidence, we propose directions for new research that can determine whether ALP as a treatment strategy for AKI has a future in the clinical field.


Asunto(s)
Lesión Renal Aguda , Fosfatasa Alcalina , Lesión Renal Aguda/etiología , Lesión Renal Aguda/terapia , Humanos , Fosfatasa Alcalina/metabolismo , Animales
3.
Br J Clin Pharmacol ; 89(12): 3629-3636, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37548047

RESUMEN

AIMS: Ischemia-reperfusion injury (IRI) during kidney transplant procedures is associated with adverse outcome. Alkaline phosphatase (AP) is an enzyme that has the potential to dampen IRI. Prior to this study, it had not been tested in the setting of kidney transplantation. This study aimed to evaluate the safety and feasibility of peri-procedural AP administration in living donor kidney transplantation. METHODS: In this double blind, randomized, placebo-controlled, single-center pilot study, all eligible recipients of living donor kidneys were asked to give informed consent. AP (bRESCAP) or a placebo was administered intravenously over 24 hours after the transplantation procedure. The primary outcome-graft function at 1 year-was represented by iohexol measured glomerular filtration rate (mGFR). Serum and urine biomarkers within seven days after surgery were used as surrogate markers of kidney function and injury. RESULTS: Eleven patients were enrolled of whom five were treated with bRESCAP and six with placebo. After 1 year, mGFR was not different between groups. No specific adverse events were observed in the bRESCAP group. Urine expression of injury biomarkers CCL14, NGAL and Cystatin C was lower in the bRESCAP group at day seven. This was statistically significant. CONCLUSION: This study illustrates that bRESCAP treatment is feasible in kidney transplantation, might have a dampening effect on IRI induced renal inflammation, and raises no safety concerns. Future research will evaluate the effects of bRESCAP treatment in donation after circulatory death kidney transplantation where IRI is more pronounced.


Asunto(s)
Trasplante de Riñón , Daño por Reperfusión , Humanos , Trasplante de Riñón/efectos adversos , Fosfatasa Alcalina , Proyectos Piloto , Donadores Vivos , Estudios de Factibilidad , Riñón , Daño por Reperfusión/etiología , Biomarcadores
4.
Anesthesiology ; 132(4): 781-794, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31977519

RESUMEN

BACKGROUND: Mechanical complications arising after central venous catheter placement are mostly malposition or pneumothorax. To date, to confirm correct position and detect pneumothorax, chest x-ray film has been the reference standard, while ultrasound might be an accurate alternative. The aim of this study was to evaluate diagnostic accuracy of ultrasound to detect central venous catheter malposition and pneumothorax. METHODS: This was a prospective, multicenter, diagnostic accuracy study conducted at the intensive care unit and postanesthesia care unit. Adult patients who underwent central venous catheterization of the internal jugular vein or subclavian vein were included. Index test consisted of venous, cardiac, and lung ultrasound. Standard reference test was chest x-ray film. Primary outcome was diagnostic accuracy of ultrasound to detect malposition and pneumothorax; for malposition, sensitivity, specificity, and other accuracy parameters were estimated. For pneumothorax, because chest x-ray film is an inaccurate reference standard to diagnose it, agreement and Cohen's κ-coefficient were determined. Secondary outcomes were accuracy of ultrasound to detect clinically relevant complications and feasibility of ultrasound. RESULTS: In total, 758 central venous catheterizations were included. Malposition occurred in 23 (3.3%) out of 688 cases included in the analysis. Ultrasound sensitivity was 0.70 (95% CI, 0.49 to 0.86) and specificity 0.99 (95% CI, 0.98 to 1.00). Pneumothorax occurred in 5 (0.7%) to 11 (1.5%) out of 756 cases according to chest x-ray film and ultrasound, respectively. In 748 out of 756 cases (98.9%), there was agreement between ultrasound and chest x-ray film with a Cohen's κ-coefficient of 0.50 (95% CI, 0.19 to 0.80). CONCLUSIONS: This multicenter study shows that the complication rate of central venous catheterization is low and that ultrasound produces a moderate sensitivity and high specificity to detect malposition. There is moderate agreement with chest x-ray film for pneumothorax. In conclusion, ultrasound is an accurate diagnostic modality to detect malposition and pneumothorax.


Asunto(s)
Cateterismo Venoso Central/efectos adversos , Cateterismo Venoso Central/normas , Catéteres Venosos Centrales/efectos adversos , Catéteres Venosos Centrales/normas , Ultrasonografía Intervencional/métodos , Ultrasonografía Intervencional/normas , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
6.
Respir Care ; 66(6): 994-1003, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33850048

RESUMEN

BACKGROUND: A weaning trial can be considered a stress test of the cardiorespiratory system; it increases oxygen demand and thus warrants a higher cardiac index and elevated breathing effort. We hypothesized that the combination of easily performed ultrasound measurements of heart, lungs, and diaphragm would yield good diagnostic accuracy to predict extubation failure. METHODS: Adult subjects ventilated for > 72 h with a successful spontaneous breathing trial were included. Ultrasound measurements of heart (left ventricular function), lungs (number of B-lines), and diaphragm thickening fraction were performed during a spontaneous breathing trial. The primary outcomes were sensitivity, specificity, and area under the receiver operating characteristic curve of a holistic ultrasound approach for extubation failure. Re-intubation within 48 h was considered extubation failure. RESULTS: Eighty-three subjects were included, of whom 15 (18%) were re-intubated within 48 h. The sensitivity and specificity of a holistic approach were 100% (78.2-100%) and 7.7% (2.5-17.1%), respectively, with an area under the receiver operating characteristic curve of 0.54. The sensitivity and specificity of diaphragm thickening fraction, using a cutoff value of < 30% for extubation failure were 86.7% (59.5-98.3%) and 25.4% (15.5-37.5%), respectively, with an area under the receiver operating characteristic curve of 0.61. CONCLUSIONS: In subjects ventilated for > 72 h who had a successful spontaneous breathing trial, holistic ultrasound was a weak predictor for extubation failure. (ClinicalTrials.gov registration NCT04196361).


Asunto(s)
Extubación Traqueal , Desconexión del Ventilador , Adulto , Diafragma/diagnóstico por imagen , Humanos , Estudios Prospectivos , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA