Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Intern Med ; 271(6): 598-607, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21988283

RESUMEN

BACKGROUND: The aim of our study was to investigate the diagnostic and prognostic value of a sensitive cardiac troponin I (s-cTnI) assay in patients with acute heart failure (AHF). METHODS: Sensitive cardiac troponin I was measured in 667 consecutive patients at presentation to the emergency department with acute dyspnoea. Three s-cTnI strata were predefined: below the limit of detection (<0.01 µg L(-1) , undetectable), detectable but still within the normal range (0.01-0.027 µg L(-1) ) and increased (≥0.028 µg L(-1) , ≥99th percentile). The final diagnosis was adjudicated by two independent cardiologists blinded to the s-cTnI levels. Median follow-up in patients with AHF was 371 days. RESULTS: Levels of s-cTnI were higher in patients with AHF (n = 377, 57%) compared to patients with noncardiac causes of acute dyspnoea (median 0.02 vs. <0.01 µg L(-1) , P < 0.001). In patients with AHF, in-hospital mortality increased with increasing s-cTnI in the three strata (2%, 5% and 14%, P < 0.001). One-year mortality also increased with increasing s-cTnI (21%, 33% and 47%, P < 0.001). s-cTnI remained an independent predictor of 1-year mortality [adjusted odds ratio 1.03 for each increase of 0.1 µg L(-1) , 95% confidence interval (CI) 1.02-1.05, P < 0.001] after adjustment for other risk factors including B-type natriuretic peptide. The net reclassification improvement was 68% (P < 0.001), and absolute integrated discrimination improvement was 0.18 (P < 0.001). The diagnostic accuracy of s-cTnI for the diagnosis of AHF as quantified by the area under the receiver operating characteristic curve was 0.78 (95% CI, 0.75-0.82). CONCLUSIONS: Sensitive cardiac troponin I is a strong predictor of short- and long-term prognosis in AHF that helps to reclassify patients in terms of mortality risk. Detectable levels of s-cTnI, even within the normal range, are independently associated with mortality.


Asunto(s)
Insuficiencia Cardíaca/diagnóstico , Troponina I/sangre , Enfermedad Aguda , Anciano , Anciano de 80 o más Años , Algoritmos , Biomarcadores/sangre , Intervalos de Confianza , Servicio de Urgencia en Hospital , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Oportunidad Relativa , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Medición de Riesgo , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Análisis de Supervivencia
2.
J Intern Med ; 267(1): 119-29, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19570053

RESUMEN

OBJECTIVES: The concentration of atrial natriuretic peptide (ANP) in the circulation is approximately 10- to 50- fold higher than B-type natriuretic peptide (BNP). We sought to compare the accuracy of midregional pro-atrial natriuretic peptide (MRproANP) measured with a novel sandwich immunoassay with N-terminal pro-B-type natriuretic peptide (NTproBNP) in the diagnosis of heart failure. DESIGN: The diagnosis of heart failure was adjudicated by two independent cardiologists using all available clinical data (including BNP levels) in 287 consecutive patients presenting with dyspnoea to the emergency department (ED). MRproANP and NTproBNP levels were determined at presentation in a blinded fashion. RESULTS: Heart failure was the adjudicated final diagnosis in 154 patients (54%). Median MRproANP was significantly higher in patients with heart failure as compared to patients with other causes of dyspnoea (400 vs. 92 pmol L(-1), P < 0.001). The diagnostic accuracy of MRproANP was very high with an area under the receiver operating characteristic curve of 0.92 and was comparable with that of NTproBNP (0.92, P = 0.791). Moreover, MRproANP provided incremental diagnostic information to BNP and NTproBNP in patients presenting with BNP levels in the grey zone between 100 and 500 pg mL(-1). CONCLUSION: Midregional pro-atrial natriuretic peptide is as accurate in the diagnosis of heart failure as NTproBNP. MRproANP seems to provide incremental information on top of BNP or NT-proBNP in some subgroups and should be further investigated in other studies.


Asunto(s)
Factor Natriurético Atrial/sangre , Insuficiencia Cardíaca/diagnóstico , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Anciano , Biomarcadores/sangre , Disnea/diagnóstico , Disnea/etiología , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Curva ROC , Factores de Riesgo , Tasa de Supervivencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA