Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Diagnostics (Basel) ; 14(10)2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38786284

RESUMEN

Many clinical studies have shown wide performance variation in tests to identify coronary artery disease (CAD). Coronary computed tomography angiography (CCTA) has been identified as an effective rule-out test but is not widely available in the USA, particularly so in rural areas. Patients in rural areas are underserved in the healthcare system as compared to urban areas, rendering it a priority population to target with highly accessible diagnostics. We previously developed a machine-learned algorithm to identify the presence of CAD (defined by functional significance) in patients with symptoms without the use of radiation or stress. The algorithm requires 215 s temporally synchronized photoplethysmographic and orthogonal voltage gradient signals acquired at rest. The purpose of the present work is to validate the performance of the algorithm in a frozen state (i.e., no retraining) in a large, blinded dataset from the IDENTIFY trial. IDENTIFY is a multicenter, selectively blinded, non-randomized, prospective, repository study to acquire signals with paired metadata from subjects with symptoms indicative of CAD within seven days prior to either left heart catheterization or CCTA. The algorithm's sensitivity and specificity were validated using a set of unseen patient signals (n = 1816). Pre-specified endpoints were chosen to demonstrate a rule-out performance comparable to CCTA. The ROC-AUC in the validation set was 0.80 (95% CI: 0.78-0.82). This performance was maintained in both male and female subgroups. At the pre-specified cut point, the sensitivity was 0.85 (95% CI: 0.82-0.88), and the specificity was 0.58 (95% CI: 0.54-0.62), passing the pre-specified endpoints. Assuming a 4% disease prevalence, the NPV was 0.99. Algorithm performance is comparable to tertiary center testing using CCTA. Selection of a suitable cut-point results in the same sensitivity and specificity performance in females as in males. Therefore, a medical device embedding this algorithm may address an unmet need for a non-invasive, front-line point-of-care test for CAD (without any radiation or stress), thus offering significant benefits to the patient, physician, and healthcare system.

2.
Front Cardiovasc Med ; 9: 980625, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36211581

RESUMEN

Introduction: Elevated left ventricular end diastolic pressure (LVEDP) is a consequence of compromised left ventricular compliance and an important measure of myocardial dysfunction. An algorithm was developed to predict elevated LVEDP utilizing electro-mechanical (EM) waveform features. We examined the hierarchical clustering of selected features developed from these EM waveforms in order to identify important patient subgroups and assess their possible prognostic significance. Materials and methods: Patients presenting with cardiovascular symptoms (N = 396) underwent EM data collection and direct LVEDP measurement by left heart catheterization. LVEDP was classified as non-elevated ( ≤ 12 mmHg) or elevated (≥25 mmHg). The 30 most contributive features to the algorithm output were extracted from EM data and input to an unsupervised hierarchical clustering algorithm. The resultant dendrogram was divided into five clusters, and patient metadata overlaid. Results: The cluster with highest LVEDP (cluster 1) was most dissimilar from the lowest LVEDP cluster (cluster 5) in both clustering and with respect to clinical characteristics. In contrast to the cluster demonstrating the highest percentage of elevated LVEDP patients, the lowest was predominantly non-elevated LVEDP, younger, lower BMI, and males with a higher rate of significant coronary artery disease (CAD). The next adjacent cluster (cluster 2) to that of the highest LVEDP (cluster 1) had the second lowest LVEDP of all clusters. Cluster 2 differed from Cluster 1 primarily based on features extracted from the electrical data, and those that quantified predictability and variability of the signal. There was a low predictability and high variability in the highest LVEDP cluster 1, and the opposite in adjacent cluster 2. Conclusion: This analysis identified subgroups of patients with varying degrees of LVEDP elevation based on waveform features. An approach to stratify movement between clusters and possible progression of myocardial dysfunction may include changes in features that differentiate clusters; specifically, reductions in electrical signal predictability and increases in variability. Identification of phenotypes of myocardial dysfunction evidenced by elevated LVEDP and knowledge of factors promoting transition to clusters with higher levels of left ventricular filling pressures could permit early risk stratification and improve patient selection for novel therapeutic interventions.

3.
Front Cardiovasc Med ; 9: 956147, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36119746

RESUMEN

Introduction: Multiple trials have demonstrated broad performance ranges for tests attempting to detect coronary artery disease. The most common test, SPECT, requires capital-intensive equipment, the use of radionuclides, induction of stress, and time off work and/or travel. Presented here are the development and clinical validation of an office-based machine learned algorithm to identify functionally significant coronary artery disease without radiation, expensive equipment or induced patient stress. Materials and methods: The IDENTIFY trial (NCT03864081) is a prospective, multicenter, non-randomized, selectively blinded, repository study to collect acquired signals paired with subject meta-data, including outcomes, from subjects with symptoms of coronary artery disease. Time synchronized orthogonal voltage gradient and photoplethysmographic signals were collected for 230 seconds from recumbent subjects at rest within seven days of either left heart catheterization or coronary computed tomography angiography. Following machine learning on a proportion of these data (N = 2,522), a final algorithm was selected, along with a pre-specified cut point on the receiver operating characteristic curve for clinical validation. An unseen set of subject signals (N = 965) was used to validate the algorithm. Results: At the pre-specified cut point, the sensitivity for detecting functionally significant coronary artery disease was 0.73 (95% CI: 0.68-0.78), and the specificity was 0.68 (0.62-0.74). There exists a point on the receiver operating characteristic curve at which the negative predictive value is the same as coronary computed tomographic angiography, 0.99, assuming a disease incidence of 0.04, yielding sensitivity of 0.89 and specificity of 0.42. Selecting a point at which the positive predictive value is maximized, 0.12, yields sensitivity of 0.39 and specificity of 0.88. Conclusion: The performance of the machine learned algorithm presented here is comparable to common tertiary center testing for coronary artery disease. Employing multiple cut points on the receiver operating characteristic curve can yield the negative predictive value of coronary computed tomographic angiography and a positive predictive value approaching that of myocardial perfusion imaging. As such, a system employing this algorithm may address the need for a non-invasive, no radiation, no stress, front line test, and hence offer significant advantages to the patient, their physician, and healthcare system.

4.
PLoS One ; 17(11): e0277300, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36378672

RESUMEN

BACKGROUND: Phase space is a mechanical systems approach and large-scale data representation of an object in 3-dimensional space. Whether such techniques can be applied to predict left ventricular pressures non-invasively and at the point-of-care is unknown. OBJECTIVE: This study prospectively validated a phase space machine-learned approach based on a novel electro-mechanical pulse wave method of data collection through orthogonal voltage gradient (OVG) and photoplethysmography (PPG) for the prediction of elevated left ventricular end diastolic pressure (LVEDP). METHODS: Consecutive outpatients across 15 US-based healthcare centers with symptoms suggestive of coronary artery disease were enrolled at the time of elective cardiac catheterization and underwent OVG and PPG data acquisition immediately prior to angiography with signals paired with LVEDP (IDENTIFY; NCT #03864081). The primary objective was to validate a ML algorithm for prediction of elevated LVEDP using a definition of ≥25 mmHg (study cohort) and normal LVEDP ≤ 12 mmHg (control cohort), using AUC as the measure of diagnostic accuracy. Secondary objectives included performance of the ML predictor in a propensity matched cohort (age and gender) and performance for an elevated LVEDP across a spectrum of comparative LVEDP (<12 through 24 at 1 mmHg increments). Features were extracted from the OVG and PPG datasets and were analyzed using machine-learning approaches. RESULTS: The study cohort consisted of 684 subjects stratified into three LVEDP categories, ≤12 mmHg (N = 258), LVEDP 13-24 mmHg (N = 347), and LVEDP ≥25 mmHg (N = 79). Testing of the ML predictor demonstrated an AUC of 0.81 (95% CI 0.76-0.86) for the prediction of an elevated LVEDP with a sensitivity of 82% and specificity of 68%, respectively. Among a propensity matched cohort (N = 79) the ML predictor demonstrated a similar result AUC 0.79 (95% CI: 0.72-0.8). Using a constant definition of elevated LVEDP and varying the lower threshold across LVEDP the ML predictor demonstrated and AUC ranging from 0.79-0.82. CONCLUSION: The phase space ML analysis provides a robust prediction for an elevated LVEDP at the point-of-care. These data suggest a potential role for an OVG and PPG derived electro-mechanical pulse wave strategy to determine if LVEDP is elevated in patients with symptoms suggestive of cardiac disease.


Asunto(s)
Disfunción Ventricular Izquierda , Humanos , Disfunción Ventricular Izquierda/diagnóstico , Presión Sanguínea , Sistemas de Atención de Punto , Análisis de la Onda del Pulso , Aprendizaje Automático , Función Ventricular Izquierda , Presión Ventricular , Volumen Sistólico
5.
PLoS One ; 13(8): e0198603, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30089110

RESUMEN

BACKGROUND: Artificial intelligence (AI) techniques are increasingly applied to cardiovascular (CV) medicine in arenas ranging from genomics to cardiac imaging analysis. Cardiac Phase Space Tomography Analysis (cPSTA), employing machine-learned linear models from an elastic net method optimized by a genetic algorithm, analyzes thoracic phase signals to identify unique mathematical and tomographic features associated with the presence of flow-limiting coronary artery disease (CAD). This novel approach does not require radiation, contrast media, exercise, or pharmacological stress. The objective of this trial was to determine the diagnostic performance of cPSTA in assessing CAD in patients presenting with chest pain who had been referred by their physician for coronary angiography. METHODS: This prospective, multicenter, non-significant risk study was designed to: 1) develop machine-learned algorithms to assess the presence of CAD (defined as one or more ≥ 70% stenosis, or fractional flow reserve ≤ 0.80) and 2) test the accuracy of these algorithms prospectively in a naïve verification cohort. This report is an analysis of phase signals acquired from 606 subjects at rest just prior to angiography. From the collective phase signal data, features were extracted and paired with the known angiographic results. A development set, consisting of signals from 512 subjects, was used for machine learning to determine an algorithm that correlated with significant CAD. Verification testing of the algorithm was performed utilizing previously untested phase signals from 94 subjects. RESULTS: The machine-learned algorithm had a sensitivity of 92% (95% CI: 74%-100%) and specificity of 62% (95% CI: 51%-74%) on blind testing in the verification cohort. The negative predictive value (NPV) was 96% (95% CI: 85%-100%). CONCLUSIONS: These initial multicenter results suggest that resting cPSTA may have comparable diagnostic utility to functional tests currently used to assess CAD without requiring cardiac stress (exercise or pharmacological) or exposure of the patient to radioactivity.


Asunto(s)
Algoritmos , Enfermedad de la Arteria Coronaria/diagnóstico , Técnicas de Diagnóstico Cardiovascular , Aprendizaje Automático , Anciano , Angiografía Coronaria , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector/métodos , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad
6.
Int J Parasitol ; 37(14): 1599-607, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17585919

RESUMEN

Measurement of parasite proliferation in cultured red blood cells underpins many facets of malaria research, from drug sensitivity assays to assessing the impact of experimentally altered genes on parasite growth, virulence and fitness. Pioneering efforts to grow Plasmodium falciparum in cultured red blood cells revolutionised malaria research and spurred the development of semi-high-throughput growth assays using radio-labelled hypoxanthine (Hx), an essential nucleic acid precursor, as a reporter of whole-cycle proliferation [Trager, W., Jensen, J.B., 1976. Human malaria parasites in continuous culture. Science 193, 673-675; Desjardins, R.E., Canfield, C.J., Haynes, J.D., Chulay, J.D., 1979. Quantitative assessment of antimalarial activity in vitro by a semiautomated microdilution technique. Antimicrob. Agents Chemother. 16, 710-718]. The isotopic Hx assay remains the standard quantitative growth assay with which newer non-radioactive procedures based on fluorescent DNA dyes or ELISA are compared. All of these readouts are surrogate reporters of changes in bulk parasitemias, reflecting proliferation over entire asexual reproductive cycles. While quantitatively robust and amenable to semi-high-throughput applications, these methods are blind to the underlying developmental and cellular events of growth in human red blood cells. Modern whole-genome tools including gene knockouts, mutagenesis and small molecule screens promise to reveal much about basic parasite biology; however methods to precisely quantify the within-cycle growth process are needed. Here we elaborate on the classical growth index, i.e. changes in parasitemia, by quantifying sub-phenotypes of a rapid proliferator, the multi-drug resistant clone Dd2, and a standard wild-type clone, HB3. These data illustrate differences in cycle duration, merozoite production, and invasion rate and efficiency that underpin Dd2's average 2-fold proliferation advantage over HB3 per erythrocytic cycle. The ability to refine growth phenotypes will inform the search for molecular determinants of differential parasite growth rates and broaden our understanding of killing mechanisms and cellular targets of antimalarial drugs.


Asunto(s)
Eritrocitos/parasitología , Plasmodium falciparum/crecimiento & desarrollo , Animales , Células Cultivadas , Células Clonales/fisiología , Resistencia a Medicamentos , Hipoxantina , Estadios del Ciclo de Vida , Merozoítos/fisiología , Parasitología/métodos , Fenotipo , Plasmodium falciparum/clasificación , Plasmodium falciparum/efectos de los fármacos , Plasmodium falciparum/patogenicidad , Esquizontes/fisiología , Especificidad de la Especie , Virulencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA