Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Aesthetic Plast Surg ; 36(3): 623-7, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22101987

RESUMEN

The reconstruction of the auricle is aesthetically very demanding. Various techniques have been used depending on the defect size, the defect location, and tissue involved. For better wound control and result predictability, we developed an anteriorly pedicled retroauricular flap. We used this modified double-full-thickness skin graft in three patients. This anteriorly pedicled flap provides a visible wound surface which makes wound dressing easy. The aesthetic outcome is good and predictable. No major complications were encountered during surgery or the healing phase. All patients were satisfied with the outcome. The described method offers a good option for reconstructing larger auricular defects with local tissue.


Asunto(s)
Pabellón Auricular/cirugía , Procedimientos de Cirugía Plástica/métodos , Colgajos Quirúrgicos , Humanos
2.
Aesthetic Plast Surg ; 36(3): 653-9, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22395301

RESUMEN

BACKGROUND: The intention of mandibular reconstructive surgery is to achieve maximum possible functionality, which means the restoration of masticatory function and speech with a good esthetic result. METHODS: We compared five computer-assisted mandibular reconstructions with 15 conventional mandibular reconstructions performed using vascularized iliac crest bone grafts. Based on preoperative cone beam computed tomography (CBCT) or CT data imported into the specific surgical planning software, a surgical guide was designed by rapid prototyping that helped to exactly translate the virtual surgery plan into the operation site whereby it fit uniquely to the iliac donor site. The ischemic time of the graft was measured intraoperatively and the difference between the amount of bone removed and the amount of bone required was determined. In addition, 3 months after surgery patients had to score the esthetics of their outer appearance using a visual analog scale. RESULTS: In all patients the graft fit perfectly into the mandibular defect without major adjustments. The time for the shaping process of the transplant and the ischemic time were shorter than in the conventional grafting procedure. The virtual plan reduced the amount of bone removed to the required volume. The patients who underwent computer-assisted reconstruction had a higher degree of satisfaction with their outer appearance. CONCLUSION: Our clinical experience and the collected data suggest that the described method is very promising for optimizing the surgical result of mandibular reconstructions using iliac crest bone grafts and achieving an excellent esthetic outcome. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.


Asunto(s)
Ilion/trasplante , Enfermedades Mandibulares/cirugía , Procedimientos de Cirugía Plástica/métodos , Cirugía Asistida por Computador , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
3.
Pediatrics ; 143(2)2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30700565

RESUMEN

OBJECTIVES: Our aim for this study was to test whether visual and verbal feedback compared with instructor-led feedback improve the quality of pediatric cardiopulmonary resuscitation (CPR). METHODS: There were 653 third-year medical students randomly assigned to practice pediatric CPR on 1 of 2 manikins (infant and adolescent; n = 344 and n = 309, respectively). They were further randomly assigned to 1 of 3 feedback groups: The instructor feedback (IF) group (n = 225) received traditional, instructor-led feedback without any additional feedback device. The device feedback (DF) group (n = 223) received real-time visual feedback from a feedback device. The instructor and device feedback (IDF) group (n = 205) received verbal feedback from an instructor who continuously reviewed the trainees' performance using the feedback device. After the training, participants' CPR performance was assessed on the same manikin while no feedback was being provided. RESULTS: For the primary outcome of total compression score, participants in the DF and IDF groups performed similarly, with both groups showing scores significantly (P < .001) better than those of the IF group. The same findings held for correct hand position and the proportion of complete release. For compression rate, the DF group was at the higher end of the guideline for 100 to 120 chest compressions per minute compared with the IF and IDF groups (both P < .001). No effect of feedback on compression depth was found. CONCLUSIONS: Chest compression performance significantly improved with both visual and verbal feedback compared with instructor-led feedback. Feedback devices should be implemented during pediatric resuscitation training to improve resuscitation performance.


Asunto(s)
Reanimación Cardiopulmonar/métodos , Reanimación Cardiopulmonar/normas , Competencia Clínica , Retroalimentación Sensorial , Maniquíes , Estudiantes de Medicina , Adulto , Femenino , Humanos , Masculino , Estudios Prospectivos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA