Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur Radiol ; 34(4): 2689-2698, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37804340

RESUMEN

OBJECTIVES: Visualizing left atrial anatomy including the pulmonary veins (PVs) is important for planning the procedure of pulmonary vein isolation with ablation in patients with atrial fibrillation (AF). The aims of our study are to investigate the feasibility of the 3D whole-heart bright-blood and black-blood phase-sensitive (BOOST) inversion recovery sequence in patients with AF scheduled for ablation or electro-cardioversion, and to analyze the correlation between image quality and heart rate and rhythm of patients. METHODS: BOOST was performed for assessing PVs both with T2 preparation pre-pulse (T2prep) and magnetization transfer preparation (MTC) in 45 patients with paroxysmal or permanent AF scheduled for ablation or electro-cardioversion. Image quality analyses were performed by two independent observers. Qualitative assessment was made using the Likert scale; for quantitative analysis, signal to noise ratios (SNR) and contrast to noise ratios (CNR) were calculated for each PV. Heart rate and rhythm were analyzed based on standard 12-lead ECGs. RESULTS: All MTC-BOOST acquisitions achieved diagnostic quality in the PVs, while a significant proportion of T2prep-BOOST images were not suitable for assessing PVs. SNR and CNR values of the MTC-BOOST bright-blood images were higher if patients had sinus rhythm. We found a significant or nearly significant negative correlation between heart rate and the SNR and CNR values of MTC-BOOST bright-blood images. CONCLUSION: 3D whole-heart MTC-BOOST bright-blood imaging is suitable for visualizing the PVs in patients with AF, producing diagnostic image quality in 100% of cases. However, image quality was influenced by heart rate and rhythm. CLINICAL RELEVANCE STATEMENT: The novel 3D whole-heart BOOST CMR sequence needs no contrast administration and is performed during free-breathing; therefore, it is easy to use for a wide range of patients and is suitable for visualizing the PVs in patients with AF. KEY POINTS: • The applicability of the novel 3D whole-heart bright-blood and black-blood phase-sensitive sequence to pulmonary vein imaging in clinical practice is unknown. • Magnetization transfer-bright-blood and black-blood phase-sensitive imaging is suitable for visualizing the pulmonary veins in patients with atrial fibrillation with excellent or good image quality. • Bright-blood and black-blood phase-sensitive cardiac magnetic resonance sequence is easy to use for a wide range of patients as it needs no contrast administration and is performed during free-breathing.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Estudios de Factibilidad , Atrios Cardíacos/diagnóstico por imagen , Electrocardiografía , Imagen por Resonancia Magnética , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Ablación por Catéter/métodos
2.
Europace ; 25(11)2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37931067

RESUMEN

AIMS: Cerebral thrombo-embolism is a dreaded complication of pulmonary vein isolation (PVI) for atrial fibrillation; its surrogate, silent cerebral embolism (SCE) can be detected by diffusion-weighted brain magnetic resonance imaging (bMRI). Initial investigations have raised a concern that very high-power, short-duration (vHPSD; 90 W/4 s) temperature-controlled PVI with the QDOT Micro catheter may be associated with a higher incidence of SCE compared with low-power long-duration ablation. We aimed to assess the incidence of procedural complications of vHPSD PVI with an emphasis on cerebral safety. METHODS AND RESULTS: We enrolled 328 consecutive patients undergoing their PVI procedure using vHPSD. A subgroup of 61 consecutive patients underwent diffusion-weighted bMRI within 24 h of the procedure, and incidence and predictors of SCE were studied. The mean procedure time and left atrial dwell time for the overall cohort were 69.6 ± 24.1 and 46.5 ± 21.5 min, respectively. First-pass isolation was achieved in 82%. No stroke or transient ischaemic attack occurred. Silent cerebral embolism was identified in 5 of 61 patients (8.2%). Silent cerebral embolism following procedures was significantly associated with lower baseline generator impedance (105.8 vs. 112.6 Ω, P < 0.0001) and with intermittent loss of catheter-tissue contact during ablation (14.1% vs. 6.1%, P < 0.0001). CONCLUSION: Very high-power, short-duration PVI is a safe technique with an excellent acute success rate. Silent cerebral embolism incidence in our cohort was below the previously reported range, with no clinically overt cerebral complications. Lower baseline generator impedance and loss of contact during ablation may contribute to a higher risk of SCEs.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Embolia Intracraneal , Venas Pulmonares , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Embolia Intracraneal/diagnóstico por imagen , Embolia Intracraneal/epidemiología , Incidencia , Atrios Cardíacos , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Resultado del Tratamiento
3.
Neuroradiology ; 64(12): 2343-2356, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35915181

RESUMEN

PURPOSE: We assessed diffusion tensor imaging (DTI) metric changes of the corpus callosum and cingulum correlated to postprocedural ischemic lesion load (ILL) and cognitive performance in transcatheter aortic valve replacement (TAVR). METHODS: TAVR subjects had DTI post-TAVR (≤ 8 days) and at 6 months (78 participants, males 56%, age 78.8 years ± 6.3) and four neurocognitive tests (pre-TAVR, post-TAVR, 6 months, 1 year). DTI metrics (fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), radial diffusivity (RD)) were calculated for 7 regions: corpus callosum (genu, body, splenium) and cingulum (cingulate gyrus, parahippocampal cingulum bilaterally). DTI metrics post-TAVR and at 6 months were compared with Student's t-test (p < 0.0071) and ANOVA covarying for sex, ILL (p < 0.05) with post hoc analysis of ILL groups (p < 0.0167). Repeated-measures linear mixed-effect model (p < 0.05) was performed to investigate the effect of time and ILL on cognition. RESULTS: At 6 months, significant decrease of the following DTI metrics was detected: AD (genu, body, splenium, right parahippocampal cingulum: p ≤ 0.0046); MD (body, both cingulate gyri: p ≤ 0.0050); RD (left cingulate gyrus: p = 0.0021); FA (splenium: p < 0.0001). ANOVA confirmed significant effect of female sex on AD + MD reduction (body, right cingulate gyrus) and AD reduction (left cingulate gyrus) (p ≤ 0.0254). Significant negative effect of ILL on some DTI metric changes was found (AD + MD-body: p ≤ 0.0050; MD-left cingulate gyrus: p = 0.0087). Cognitive performance remained stable with significant negative correlation of ILL and retrograde memory and visual scores (p ≤ 0.0483). CONCLUSION: Significant effect of TAVR on cerebral microstructural integrity was found with reduced diffusivities opposite to the trends reported in various neurodegenerative conditions/ageing, notably in women and lower ILL, and with preserved/improved cognition. TRIAL REGISTRATION NUMBER: NCT02826200 at ClinicalTrials.gov; date of registration: 07. July 2016.


Asunto(s)
Lesiones Encefálicas , Reemplazo de la Válvula Aórtica Transcatéter , Sustancia Blanca , Anciano , Femenino , Humanos , Masculino , Lesiones Encefálicas/patología , Cognición , Imagen de Difusión Tensora/métodos , Estudios Prospectivos , Sustancia Blanca/patología
4.
BMC Cardiovasc Disord ; 22(1): 395, 2022 09 04.
Artículo en Inglés | MEDLINE | ID: mdl-36058933

RESUMEN

BACKGROUND: Refractory cardiogenic shock is still a major clinical challenge with high mortality rates, although several devices can be used to conquer this event. These devices have different advantages and disadvantages originating from their insertion or cannulation method, therefore many complications can occur during their use. The aim of our study was to develop and create prototypes of a novel minimal invasively insertable, transapical cannula for surgical ventricular assist devices, which uniquely incorporates the inflow and outflow routes for the blood of the patient in itself, therefore it enables the use for only one cannula for patients in cardiogenic shock. METHODS: To define the available space for the planned cannula in the left ventricle and ascending aorta, we analyzed computed tomography scans of 24 heart failure patients, who were indicated to left ventricular assist device therapy. Parallel to these measurements, hydrodynamical calculations were performed to determine the sizes of the cannulas, which were necessary to provide effective cardiac output. RESULTS: After the designing steps, we produced prototypes of double-lumened, tube-in-tube apically insertable devices for three different patient groups, which included a separated venous and an arterial part using 3D modelling and printing technology. All the created cannulas are able to provide 5 l/min circulatory support. CONCLUSION: As a result of our research we created a sizing method based on the specific analysis of computed tomography pictures of end stage heart failure patients and a cannula concept, which can provide effective antegrade flow for patients in cardiogenic shock. We believe the improved version of our tool could have a significant therapeutic role in the future after further development based on animal and in vivo tests.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Animales , Cánula/efectos adversos , Cateterismo Cardíaco , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Choque Cardiogénico/diagnóstico por imagen , Choque Cardiogénico/terapia
5.
Br J Sports Med ; 56(10): 553-560, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34848398

RESUMEN

OBJECTIVES: To investigate the cardiovascular consequences of SARS-CoV-2 infection in highly trained, otherwise healthy athletes using cardiac magnetic resonance (CMR) imaging and to compare our results with sex-matched and age-matched athletes and less active controls. METHODS: SARS-CoV-2 infection was diagnosed by PCR on swab tests or serum immunoglobulin G antibody tests prior to a comprehensive CMR examination. The CMR protocol contained sequences to assess structural, functional and tissue-specific data. RESULTS: One hundred forty-seven athletes (94 male, median 23, IQR 20-28 years) after SARS-CoV-2 infection were included. Overall, 4.7% (n=7) of the athletes had alterations in their CMR as follows: late gadolinium enhancement (LGE) showing a non-ischaemic pattern with or without T2 elevation (n=3), slightly elevated native T1 values with or without elevated T2 values without pathological LGE (n=3) and pericardial involvement (n=1). Only two (1.4%) athletes presented with definite signs of myocarditis. We found pronounced sport adaptation in both athletes after SARS-CoV-2 infection and athlete controls. There was no difference between CMR parameters, including native T1 and T2 mapping, between athletes after SARS-CoV-2 infection and the matched athletic groups. Comparing athletes with different symptom severities showed that athletes with moderate symptoms had slightly greater T1 values than athletes with asymptomatic and mildly symptomatic infections (p<0.05). However, T1 mapping values remained below the cut-off point for most patients. CONCLUSION: Among 147 highly trained athletes after SARS-CoV-2 infection, cardiac involvement on CMR showed a modest frequency (4.7%), with definite signs of myocarditis present in only 1.4%. Comparing athletes after SARS-CoV-2 infection and healthy sex-matched and age-matched athletes showed no difference between CMR parameters, including native T1 and T2 values.


Asunto(s)
COVID-19 , Miocarditis , Atletas , Medios de Contraste , Femenino , Gadolinio , Humanos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Masculino , Miocarditis/diagnóstico por imagen , Miocardio/patología , Valor Predictivo de las Pruebas , SARS-CoV-2
6.
J Card Surg ; 37(1): 245-248, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34713934

RESUMEN

BACKGROUND: Intracardiac blood cysts are an exceedingly rare occurrence in adulthood. Detailed imaging modalities aid in the diagnosis of such incidental lesions and procedure planning. METHODS: We report the case of a 51-year-old male accusing dyspnea on exertion as a sole symptom which led to the discovery of multiple cardiac anomalies, namely, severe aortic valve insufficiency on a bicuspid aortic valve, ascending aortic aneurysm, a cystic mass on the tricuspid valve, patent foramen ovale, and an occluded right coronary artery. RESULTS: The disorders were managed in a single surgical intervention, the resected mass being confirmed as a blood cyst. CONCLUSIONS: Our case presents a unique association of cardiac disorders, including a highly uncommon intracardiac blood-filled cyst, and underlines the importance of multimodality imaging and interdisciplinary approach in the successful management of such complex cases.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Quistes , Cardiopatías Congénitas , Adulto , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Quistes/diagnóstico por imagen , Quistes/cirugía , Humanos , Masculino , Persona de Mediana Edad , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía
7.
Europace ; 22(1): 117-124, 2020 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-31713632

RESUMEN

AIMS: We aimed to assess the effect of cardiac resynchronization on left ventricular (LV) function, volumes, geometry, and mechanics in order to demonstrate reverse remodelling using cardiac magnetic resonance (CMR) with resynchronization on. METHODS AND RESULTS: New York Heart Association (NYHA) Class II-III patients on optimal medical therapy with LV ejection fraction (LVEF) ≤35%, and complete LBBB with broad QRS (>150 ms) were prospectively recruited. Cardiac magnetic resonance examination was performed at baseline and at 6-month follow-up, applying both biventricular and AOO pacing. The following data were measured: conventional CMR parameters, remodelling indices, global longitudinal, circumferential, radial strain, global dyssynchrony [mechanical dispersion (MD) defined as the standard deviation of time to peak longitudinal/circumferential strain in 16 LV segments], and regional dyssynchrony (maximum differences in time between peak septal and lateral transversal displacement). Thirteen patients (64 ± 7 years, 38% male) were enrolled. Comparing the baseline and follow-up CMR parameters measured during biventricular pacing, significant increase in LVEF, and decrease in LV end-diastolic volume index (LVEDVi) and LV end-systolic volume index (LVESVi) were found. Left ventricular remodelling indices, global longitudinal, circumferential, and radial strain values showed significant improvement. Circumferential MD decreased (20.5 ± 5.5 vs. 13.4 ± 3.4, P < 0.001), while longitudinal MD did not change. Regional dyssynchrony drastically improved (362 ± 96 vs. 104 ± 66 ms, P < 0.001). Applying AOO pacing resulted in an immediate deterioration in LVEF, LVESVi, circumferential strain, global and regional dyssynchrony. CONCLUSION: Cardiac magnetic resonance imaging during biventricular pacing is feasible and enables a more precise quantification of LV function, morphology, and mechanics. As a result, it may contribute to a better understanding of the effects of resynchronization therapy and might improve responder rate in the future.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Disfunción Ventricular Izquierda , Estimulación Cardíaca Artificial , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Humanos , Imagen por Resonancia Magnética , Masculino , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/terapia , Función Ventricular Izquierda
8.
Ann Noninvasive Electrocardiol ; 25(5): e12763, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32329134

RESUMEN

BACKGROUND: Structural myocardial changes in hypertrophic cardiomyopathy (HCM) are associated with different abnormalities on electrocardiographs (ECGs). The diagnostic value of the ECG voltage criteria used to screen for left ventricular hypertrophy (LVH) may depend on the presence and degree of myocardial fibrosis. Fibrosis can cause other changes in ECG parameters, such as pathological Q waves, fragmented QRS (fQRS), or repolarization abnormalities. METHODS: We investigated 146 patients with HCM and 35 healthy individuals who underwent cardiac magnetic resonance imaging (CMR; with late gadolinium enhancement [LGE] in HCM patients) and standard 12-lead ECGs. On the ECG, depolarization and repolarization abnormalities, the Sokolow-Lyon index, the Cornell index, and the Romhilt-Estes score were evaluated. The left ventricular ejection fraction, volumes, and myocardial mass (LVM) were quantified. Myocardial fibrosis was quantified on LGE images. RESULTS: The sensitivity of the Romhilt-Estes score was the highest (75%), and this hypertrophy criterion had the strongest correlation with the LVM index (p < .0001; r = .41). The amount of fibrosis was negatively correlated with the Cornell index (p = .015; r = -.201) and the Sokolow-Lyon index (p = .005; r = -.23), and the Romhilt-Estes score was independent of fibrosis (p = .757; r = 0.026). fQRS and strain pattern predicted more fibrosis, while the Cornell index was a negative predictor of myocardial fibrosis (p < .0001). Among others, the strain pattern was an independent predictor of the LVM (p < .0001). CONCLUSION: The Romhilt-Estes score is the most sensitive ECG criterion for detecting LVH in HCM patients, as myocardial fibrosis does not affect this criterion. The presence of fQRS and strain pattern predicts myocardial fibrosis.


Asunto(s)
Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/patología , Electrocardiografía/métodos , Hipertrofia Ventricular Izquierda/complicaciones , Hipertrofia Ventricular Izquierda/diagnóstico , Imagen por Resonancia Magnética/métodos , Adulto , Medios de Contraste , Femenino , Fibrosis , Gadolinio , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Hipertrofia Ventricular Izquierda/patología , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
9.
Radiology ; 282(2): 356-360, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27548369

RESUMEN

A 69-year-old woman presented with symptoms of presumed cardiac involvement of idiopathic retroperitoneal fibrosis, otherwise known as Ormond disease. Distinct pericoronary tissue proliferations were depicted at cardiac magnetic resonance (MR) imaging and coronary computed tomographic (CT) angiography. On images, the coronary manifestation was termed the "mistletoe sign." The presence of the mistletoe sign on cardiac MR and coronary CT angiographic images is probably rare, but it might be a characteristic manifestation of retroperitoneal fibrosis. With the increasing number of noninvasive cardiac imaging tests performed worldwide, the recognition of the mistletoe sign could be helpful in diagnosing retroperitoneal fibrosis. © RSNA, 2016 Online supplemental material is available for this article.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Fibrosis Retroperitoneal/diagnóstico por imagen , Anciano , Angiografía por Tomografía Computarizada , Diagnóstico Diferencial , Femenino , Humanos , Imagen por Resonancia Magnética
10.
Front Cardiovasc Med ; 10: 1177347, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37396587

RESUMEN

Introduction: Left atrial appendage (LAA) thrombus is the most common source of embolization in atrial fibrillation (AF). Transesophageal echocardiography (TEE) is the gold standard method for LAA thrombus exclusion. Our pilot study aimed to compare the efficacy of a new non-contrast-enhanced cardiac magnetic resonance (CMR) sequence (BOOST) with TEE for the detection of LAA thrombus and to evaluate the usefulness of BOOST images for planning radiofrequency catheter ablation (RFCA) compared with left atrial (LA) contrast-enhanced computed tomography (CT). We also attempted to assess the patients' subjective experiences with TEE and CMR. Methods: Patients with AF undergoing either electrical cardioversion or RFCA were enrolled. Participants underwent pre-procedural TEE and CMR scans to evaluate LAA thrombus status and pulmonary vein anatomy. Patient experiences with TEE and CMR were assessed using a questionnaire developed by our team. Some patients scheduled for RFCA also had pre-procedural LA contrast-enhanced CT. In such cases, the operating physician was asked to subjectively define the quality of the CT and CMR scan on a scale of 1-10 (1 = worst, 10 = best) and comment on CMR's usefulness in RFCA planning. Results: Seventy-one patients were enrolled. In 94.4%, both TEE and CMR excluded, and in 1 patient, both modalities reported the presence of LAA thrombus. In 1 patient, TEE was inconclusive, but CMR excluded LAA thrombus. In 2 patients, CMR could not exclude the presence of thrombus, but in 1 of those cases, TEE was also indecisive. During TEE, 67%, during CMR, only 1.9% of patients reported pain (p < 0.0001), and 89% would prefer CMR in case of a repeat examination. The quality of the left atrial contrast-enhanced CT scans was better compared with the image quality of the CMR BOOST sequence [8 (7-9) vs. 6 (5-7), p < 0.0001]. Still, the CMR images were useful for procedural planning in 91% of cases. Conclusion: The new CMR BOOST sequence provides appropriate image quality for ablation planning. The sequence might be useful for excluding larger LAA thrombi; however, its accuracy in detecting smaller thrombi is limited. Most patients preferred CMR over TEE in this indication.

11.
Orv Hetil ; 163(3): 109-115, 2022 01 16.
Artículo en Húngaro | MEDLINE | ID: mdl-35034008

RESUMEN

Összefoglaló. Bevezetés: Az aortabetegségek kezelése során az orvos által módosított sztentgraftok alkalmazása vitatott. Döntoen sürgosségi esetben, nagy rizikójú nyitott mutét alternatívájaként vagy nehéz anatómiai konfigurációk esetén alkalmazzák oket. Módszer: Cikkünkben három eseten keresztül klinikánk kezdeti tapasztalatait mutatjuk be az orvos által a mutét során módosított sztentgraftokkal kapcsolatosan. Eredmények: Elso esetünkben egy 75 éves férfi beteg 50 mm-es saccularis infrarenalis aortaaneurysma miatt került felvételre. A rövid infrarenalis tágulat proximalis rögzítési zónájának átméroje lényegesen nagyobb volt, mint a terminális aortaszakasz. A kaliberdiszkrepancia megoldására a legalkalmasabb egy reverz helyzetu iliacagraftszár volt, így egy graftszárat a felvezetorendszerérol eltávolítottunk, majd megfordítva az aorta tágulatába deponáltuk. Hasonló megoldást választottunk egy 67 éves férfi beteg jobb oldali, 65 mm-es arteria iliaca communis aneurysmájának kezelése során. Egy 81 éves nobeteg hasi aortaaneurysma tartott rupturája miatt korábban behelyezett unilateralis graft proximalis endoleakjének megoldása miatt érkezett. Az ectaticus aorta, valamint az arteria mesenterica superior és a primer intervenció során bekerült unilateralis graft elkeskenyedo része közti rövid távolság miatt konvencionális sztentgraft beültetése nem volt lehetséges. A szituáció egy rövid thoracalis sztentgrafttal volt megoldható: egy thoracalis sztentgraft distalis végébol 3 cm-t kauter segítségével levágtunk, majd az eszközt a felvezetorendszerbe visszatöltöttük. A módosított sztentgraftot az arteria mesenterica superior alá pozicionáltuk, egy 'chimney' sztentgraft segítségével biztosítottuk a jobb vese perfúzióját. Technikailag mindhárom beavatkozásunk sikeres volt. Következtetés: Az endovascularis aortamutétek azonnal elérheto eszközparkja a típusos anatómiájú betegek megoldására általában alkalmas. A szokatlan anatómiával rendelkezo elektív esetek, illetve a sürgeto beavatkozást igénylo komplex endovascularis mutétek során az orvos által módosított sztentgraftok hatékonyan alkalmazhatók. Alkalmazásuk nagy forgalmú aortacentrumokban javasolt. Orv Hetil. 2022; 163(3): 109-115. INTRODUCTION: Physician-modified endografts are mainly used in urgent cases of aortic disease as an alternative to high-risk open surgical repair or in difficult anatomical configurations. METHOD: We present our initial experiences with physician-modified stent graft implantation. RESULTS: A 75-year-old male patient was admitted with a 50 mm saccular infrarenal aortic aneurysm. However, the diameter of the proximal sealing zone was significantly larger than that of the distal sealing zone, so we decided to use an iliac limb stent graft with reverse mounting resulting in an upside-down configuration to accommodate this diameter mismatch. A similar approach was used to treat a 67-year-old male patient with a 65 mm right common iliac artery aneurysm. An 81-year-old female patient was admitted with a type I endoleak associated with an aorto-uni-iliac endograft. The wide juxtarenal aortic diameter together with the short distance between the superior mesenteric artery and the proximal end of the previously deployed uni-iliac graft made the patient unsuitable for conventional endovascular repair, thus the distal 3 cm was cut from a standard thoracic stent graft and the device was reloaded. The modified graft was positioned below the superior mesenteric artery, while renal perfusion was secured by a chimney graft. Technical success was obtained in all three cases. CONCLUSION: The available toolkit of endovascular aortic surgery is generally suitable for the treatment of patients with typical anatomy. In elective cases of patients with unusual anatomy, or in urgent cases with complex aortic pathologies, physician-modified endovascular graft implantation can be used effectively. Orv Hetil. 2022; 163(3): 109-115.


Asunto(s)
Endometriosis , Médicos , Anciano , Anciano de 80 o más Años , Femenino , Hospitalización , Humanos , Arteria Ilíaca , Riñón , Masculino
13.
Front Cardiovasc Med ; 9: 951943, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36277778

RESUMEN

Aims: To evaluate the patient- and procedure-related predictors of transcatheter aortic-valve implantation (TAVI)-associated ischemic brain lesions and to assess the effect of silent cerebral ischemic lesions (SCIL) on neurocognitive function. Methods and results: We investigated 113 consecutive patients with severe aortic stenosis who underwent brain magnetic resonance imaging (MRI) within a week following TAVI. To assess periprocedural cerebral ischemic lesions, diffusion-weighted MRI was utilized. We used multivariate linear regression to identify the independent predictors of TAVI-related ischemic lesion volume (ILV) and periprocedural stroke. Neurocognitive evaluation was performed before and following TAVI at 6-month and one-year follow-up. Following TAVI, a total of 944 new cerebral ischemic lesions were detected in 104 patients (92%). The median ILV was 257 µl (interquartile range [IQR]:97.1-718.8µl) with a median lesion number of 6/patient [IQR:2-10]. The majority of ischemic lesions were clinically silent (95%), while 5% of the lesions induced a stroke, which was confirmed by MRI. Predilatation (ß = 1.13[95%CI:0.32-1.93], p = 0.01) and the number of valve positioning attempts during implantation (ß = 0.28[95%CI:0.06-0.50], p = 0.02) increased the log-transformed total ILV. Predilatation (OR = 12.04[95%CI:1.46-99.07], p = 0.02) and alternative access routes (OR = 7.84[95%CI:1.01-61.07], p = 0.02) were associated with stroke after adjustments for comorbidities and periprocedural factors. The presence of SCILs were not associated with a change in neurocognitive function that remained stable during the one-year follow-up. Conclusion: While periprocedural ischemic lesions are frequent, most of them are clinically silent and might not impact the patients' neurocognitive function. The number of valve positioning attempts, predilatation, and alternative access routes should be taken into consideration during TAVI to reduce the ILV and risk for stroke.

14.
Front Cardiovasc Med ; 9: 974805, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36158821

RESUMEN

Introduction: We aimed to evaluate the relationship between quantitative plaque metrics derived from coronary CT angiography (CTA) and segmental myocardial ischemia using dynamic perfusion CT (DPCT). Methods: In a prospective single-center study, patients with > 30% stenosis on rest CTA underwent regadenoson stress DPCT. 480 myocardium segments of 30 patients were analyzed. Quantitative plaque assessment included total plaque volume (PV), area stenosis, and remodeling index (RI). High-risk plaque (HRP) was defined as low-attenuation plaque burden > 4% or RI > 1.1. Absolute myocardial blood flow (MBF) and relative MBF (MBFi: MBF/75th percentile of all MBF values) were quantified. Linear and logistic mixed models correcting for intra-patient clustering and clinical factors were used to evaluate the association between total PV, area stenosis, HRP and MBF or myocardial ischemia (MBF < 101 ml/100 g/min). Results: Median MBF and MBFi were 111 ml/100 g/min and 0.94, respectively. The number of ischemic segments were 164/480 (34.2%). Total PV of all feeding vessels of a given myocardial territory differed significantly between ischemic and non-ischemic myocardial segments (p = 0.001). Area stenosis and HRP features were not linked to MBF or MBFi (all p > 0.05). Increase in PV led to reduced MBF and MBFi after adjusting for risk factors including hypertension, diabetes, and statin use (per 10 mm3; ß = -0.035, p < 0.01 for MBF; ß = -0.0002, p < 0.01 for MBFi). Similarly, using multivariate logistic regression total PV was associated with ischemia (OR = 1.01, p = 0.033; per 10 mm3) after adjustments for clinical risk factors, area stenosis and HRP. Conclusion: Total PV was independently associated with myocardial ischemia based on MBF, while area stenosis and HRP were not.

15.
J Clin Med ; 11(15)2022 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-35956102

RESUMEN

Nephroprotective imaging in peripheral arterial disease (PAD) is often crucial. We compared the diagnostic performance of non-contrast Quiescent-interval single-shot magnetic resonance angiography (QISS MRA) and carbon-dioxide digital subtraction angiography (CO2 DSA) in chronic lower extremity PAD patients. A 19-segment lower extremity arterial model was used to assess the degree of stenosis (none, <50%, 50−70%, >70%) and the image quality (5-point Likert scale: 1-non-diagnostic, 5-excellent image quality). Intra-class correlation coefficient (ICC) was calculated for inter-rater reliability. Diagnostic accuracy and interpretability were evaluated using CO2 DSA as a reference standard. 523 segments were evaluated in 28 patients (11 male, mean age: 71 ± 9 years). Median and interquartile range of subjective image quality parameters for QISS MRA were significantly better compared to CO2 DSA for all regions: (aortoiliac: 4 [4−5] vs. 3 [3−4]; femoropopliteal: 4 [4−5] vs. 4 [3−4]; tibioperoneal: 4 [3−5] vs. 3 [2−3]; all regions: 4 [4−5] vs. 3 [3−4], all p < 0.001). QISS MRA out-performed CO2 DSA regarding interpretability (98.3% vs. 86.0%, p < 0.001). Diagnostic accuracy parameters of QISS MRA for the detection of obstructive luminal stenosis (70%<) as compared to CO2 DSA were as follows: sensitivity 82.6%, specificity 96.9%, positive predictive value 89.1%, negative predictive value 94.8%. Regarding the degree of stenosis, interobserver variability for all regions was 0.97 for QISS MRA and 0.82 for CO2 DSA. QISS MRA proved to be superior to CO2 DSA regarding subjective image quality and interpretability for the imaging of chronic lower extremity PAD.

16.
J Clin Med ; 11(15)2022 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-35893427

RESUMEN

Although reaching target heart rate (HR) before coronary CT angiography (CCTA) is still of importance, adequate HR control remains a challenge for many patients. Purpose-built cardiac scanners may provide optimal image quality at higher HRs by further improving temporal resolution. We aimed to compare the amount of motion artifacts on CCTA acquired using a dedicated cardiac CT (DCCT) compared to a conventional multidetector CT (MDCT) scanner. We compared 80 DCCT images to 80 MDCT scans matched by sex, age, HR, and coronary dominance. Image quality was graded on a per-patient, per-vessel and per-segment basis. Motion artifacts were assessed using Likert scores (1: non-diagnostic, 2: severe artifacts, 3: mild artifacts, 4: no artifacts). Patients were stratified into four groups according to HR (<60/min, 60−65/min, 66−70/min and >70/min). Overall, 2328 coronary segments were evaluated. DCCT demonstrated superior overall image quality compared to MDCT (3.7 ± 0.4 vs. 3.3 ± 0.7, p < 0.001). DCCT images yielded higher Likert scores in all HR ranges, which was statistically significant in the 60−65/min, 66−70/min and >70/min ranges (3.9 ± 0.2 vs. 3.7 ± 0.2, p = 0.008; 3.5 ± 0.5 vs. 3.1 ± 0.6, p = 0.048 and 3.5 ± 0.4 vs. 2.7 ± 0.7, p < 0.001, respectively). Using a dedicated cardiac scanner results in fewer motion artifacts, which may allow optimal image quality even in cases of high HRs.

17.
PLoS One ; 17(6): e0269807, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35696411

RESUMEN

BACKGROUND: While patients with cardiac transthyretin amyloidosis are easily diagnosed with bone scintigraphy, the detection of cardiac light chain (AL) amyloidosis is challenging. Cardiac magnetic resonance (CMR) analyses play an essential role in the differential diagnosis of cardiomyopathies; however, limited data are available from cardiac AL-Amyloidosis. Hence, the purpose of the present study was to analyze the potential role of CMR in the detection of cardiac AL-amyloidosis. METHODS: We included 35 patients with proved cardiac AL-amyloidosis and two control groups constituted by 330 patients with hypertrophic cardiomyopathy (HCM) and 70 patients with arterial hypertension (HT), who underwent CMR examination. The phenotype and degree of left ventricular (LV) hypertrophy and the amount and pattern of late gadolinium enhancement (LGE) were evaluated. In addition, global and regional LV strain parameters were also analyzed using feature-tracking techniques. Sensitivity and specificity of several CMR parameters were analyzed in diagnosing cardiac AL-amyloidosis. RESULTS: The sensitivity and specificity of diffuse septal subendocardial LGE in diagnosing cardiac AL-amyloidosis was 88% and 100%, respectively. Likewise, the sensitivity and specificity of septal myocardial nulling prior to blood pool was 71% and 100%, respectively. In addition, a LV end-diastolic septal wall thickness ≥ 15 mm had an optimal diagnostic performance to differentiate cardiac AL-amyloidosis from HT (sensitivity 91%, specificity 89%). On the other hand, a reduced global LV longitudinal strain (< 15%) plus apical sparing (apex-to-base longitudinal strain > 2) had a very low sensitivity (6%) in detecting AL-Amyloidosis, but with very high specificity (100%). CONCLUSIONS: The findings from this study suggest that CMR could have an optimal diagnostic performance in the diagnosis of cardiac AL-amyloidosis. Hence, further larger studies are warranted to validate the findings from this study.


Asunto(s)
Neuropatías Amiloides Familiares , Cardiomiopatías , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas , Neuropatías Amiloides Familiares/patología , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/patología , Medios de Contraste , Gadolinio , Humanos , Hipertrofia Ventricular Izquierda/patología , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas/diagnóstico por imagen , Espectroscopía de Resonancia Magnética , Miocardio/patología , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X
18.
Eur Heart J Cardiovasc Imaging ; 23(12): 1584-1595, 2022 11 17.
Artículo en Inglés | MEDLINE | ID: mdl-36168113

RESUMEN

AIMS: Whether hypoattenuated leaflet thickening (HALT) following transcatheter aortic valve implantation (TAVI) carries a risk of subclinical brain injury (SBI) is unknown. We investigated whether HALT is associated with SBI detected on magnetic resonance imaging (MRI), and whether post-TAVI SBI impacts the patients' cognition and outcome. METHODS AND RESULTS: We prospectively enrolled 153 patients (age: 78.1 ± 6.3 years; female 44%) who underwent TAVI. Brain MRI was performed shortly post-TAVI and 6 months later to assess the occurrence of acute silent cerebral ischaemic lesions (SCIL) and chronic white matter hyperintensities (WMH). HALT was screened by cardiac computed tomography (CT) angiography (CTA) 6 months post-TAVI. Neurocognitive evaluation was performed before, shortly after and 6 months following TAVI. At 6 months, 115 patients had diagnostic CTA and 10 had HALT. HALT status, baseline, and follow-up MRIs were available in 91 cases. At 6 months, new SCIL was evident in 16%, new WMH in 66%. New WMH was more frequent (100 vs. 62%; P = 0.047) with higher median volume (319 vs. 50 mm3; P = 0.039) among HALT-patients. In uni- and multivariate analysis, HALT was associated with new WMH volume (beta: 0.72; 95%CI: 0.2-1.39; P = 0.009). The patients' cognitive trajectory from pre-TAVI to 6 months showed significant association with the 6-month SCIL volume (beta: -4.69; 95%CI: -9.13 to 0.27; P = 0.038), but was not related to the presence or volume of new WMH. During a 3.1-year follow-up, neither HALT [hazard ratio (HR): 0.86; 95%CI: 0.202-3.687; P = 0.84], nor the related WMH burden (HR: 1.09; 95%CI: 0.701-1.680; P = 0.71) was related with increased mortality. CONCLUSIONS: At 6 months post-TAVI, HALT was linked with greater WMH burden, but did not carry an increased risk of cognitive decline or mortality over a 3.1-year follow-up (NCT02826200).


Asunto(s)
Estenosis de la Válvula Aórtica , Lesiones Encefálicas , Prótesis Valvulares Cardíacas , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Resultado del Tratamiento , Trombosis/etiología , Imagen por Resonancia Magnética , Encéfalo , Lesiones Encefálicas/etiología , Válvula Aórtica/cirugía , Factores de Riesgo
19.
Int J Cardiovasc Imaging ; 37(6): 2027-2036, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33555536

RESUMEN

The prognosis of patients with hypertrophic cardiomyopathy (HCM) varies greatly. Cardiac magnetic resonance (CMR) is the gold standard method for assessing left ventricular (LV) mass and volumes. Myocardial fibrosis can be noninvasively detected using CMR. Moreover, feature-tracking (FT) strain analysis provides information about LV deformation. We aimed to investigate the prognostic significance of standard CMR parameters, myocardial fibrosis, and LV strain parameters in HCM patients. We investigated 187 HCM patients who underwent CMR with late gadolinium enhancement and were followed up. LV mass (LVM) was evaluated with the exclusion and inclusion of the trabeculae and papillary muscles (TPM). Global LV strain parameters and mechanical dispersion (MD) were calculated. Myocardial fibrosis was quantified. The combined endpoint of our study was all-cause mortality, heart transplantation, malignant ventricular arrhythmias and appropriate implantable cardioverter defibrillator (ICD) therapy. The arrhythmia endpoint was malignant ventricular arrhythmias and appropriate ICD therapy. The LVM index (LVMi) was an independent CMR predictor of the combined endpoint independent of the quantification method (p < 0.01). The univariate predictors of the combined endpoint were LVMi, global longitudinal (GLS) and radial strain and longitudinal MD (MDL). The univariate predictors of arrhythmia events included LVMi and myocardial fibrosis. More pronounced LV hypertrophy was associated with impaired GLS and increased MDL. More extensive myocardial fibrosis correlated with impaired GLS (p < 0.001). LVMi was an independent CMR predictor of major events, and myocardial fibrosis predicted arrhythmia events in HCM patients. FT strain analysis provided additional information for risk stratification in HCM patients.


Asunto(s)
Cardiomiopatía Hipertrófica , Medios de Contraste , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Cardiomiopatía Hipertrófica/patología , Fibrosis , Gadolinio , Humanos , Imagen por Resonancia Cinemagnética , Espectroscopía de Resonancia Magnética , Miocardio/patología , Valor Predictivo de las Pruebas , Pronóstico
20.
Artículo en Inglés | MEDLINE | ID: mdl-34574691

RESUMEN

BACKGROUND: The Olympic preparation of athletes has been highly influenced by COVID and post-COVID syndrome. As the complex screening of athletes is essential for safe and successful sports, we aimed to repeat the 2019-year sports cardiology screening of the Olympic Swim Team before the Olympics and to compare the results of COVID and non-COVID athletes. METHODS: Patient history, electrocardiogram, laboratory tests, body composition analysis, echocardiography, cardiopulmonary exercise test (CPET) were performed. We used time-ranking points to compare swimming performance. RESULTS: From April 2019, we examined 46 elite swimmers (24 ± 4 years). Fourteen swimmers had COVID infection; all cases were mild. During CPET there was no difference in the performance of COVID (male: VO2 max 55 ± 4 vs. 56.5 ± 5 mL/kg/min, p = 0.53; female: VO2 max 54.6 ± 4 vs. 56 ± 5.5 mL/kg/min, p = 0.86) vs. non-COVID athletes (male VO2 max 56.7 ± 5 vs. 55.5 ± 4.5 mL/kg/min, p = 0.50; female 49.6 ± 3 vs. 50.7 ± 2.6 mL/kg/min, p = 0.47) between 2019 and 2021. When comparing the time results of the National Championships, 54.8% of the athletes showed an improvement (p = 0.75). CONCLUSIONS: COVID infection with short-term detraining did not affect the performance of well-trained swimmers. According to our results, the COVID pandemic did not impair the effectiveness of the preparation for the Tokyo Olympics.


Asunto(s)
COVID-19 , Atletas , Femenino , Humanos , Masculino , SARS-CoV-2 , Natación , Tokio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA