1.
Clin Chem Lab Med ; 61(11): 1917-1929, 2023 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-36788118

RESUMEN

OBJECTIVES: To develop an isotope dilution-liquid chromatography-tandem mass spectrometry-(ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for quantification of methotrexate in human serum and plasma. METHODS: Quantitative nuclear magnetic resonance (qNMR) was used to determine absolute methotrexate content in the standard. Separation was achieved on a biphenyl reversed-phase analytical column with mobile phases based on water and acetonitrile, both containing 0.1% formic acid. Sample preparation included protein precipitation in combination with high sample dilution, and method validation according to current guidelines. The following were assessed: selectivity (using analyte-spiked samples, and relevant structural-related compounds and interferences); specificity and matrix effects (via post-column infusion and comparison of human matrix vs. neat samples); precision and accuracy (in a five-day validation analysis). RMP results were compared between two independent laboratories. Measurement uncertainty was evaluated according to current guidelines. RESULTS: The RMP separated methotrexate from potentially interfering compounds and enabled measurement over a calibration range of 7.200-5,700 ng/mL (0.01584-12.54 µmol/L), with no evidence of matrix effects. All pre-defined acceptance criteria were met; intermediate precision was ≤4.3% and repeatability 1.5-2.1% for all analyte concentrations. Bias was -3.0 to 2.1% for samples within the measuring range and 0.8-4.5% for diluted samples, independent of the sample matrix. RMP results equivalence was demonstrated between two independent laboratories (Pearson correlation coefficient 0.997). Expanded measurement uncertainty of target value-assigned samples was ≤3.4%. CONCLUSIONS: This ID-LC-MS/MS-based approach provides a candidate RMP for methotrexate quantification. Traceability of methotrexate standard and the LC-MS/MS platform were assured by qNMR assessment and extensive method validation.


Asunto(s)
Metotrexato , Espectrometría de Masas en Tándem , Humanos , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Técnicas de Dilución del Indicador , Isótopos , Estándares de Referencia , Reproducibilidad de los Resultados
2.
Analyst ; 138(14): 4022-8, 2013 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-23678484

RESUMEN

We present a semi-automated point-of-care (POC) sensor approach for the simultaneous and reagent-free determination of clinically relevant parameters in blood plasma. The portable sensor system performed direct mid-infrared (MIR) transmission measurements of blood plasma samples using a broadly tunable external-cavity quantum cascade laser source with high spectral power density. This enabled the use of a flow cell with a long path length (165 µm) which resulted in high signal-to-noise ratios and a rugged system, insensitive to clogging. Multivariate calibration models were built using well established Partial-Least-Squares (PLS) regression analysis. Selection of spectral pre-processing procedures was optimized by an automated evaluation algorithm. Several analytes, including glucose, lactate, triglycerides, cholesterol, total protein as well as albumin, were successfully quantified in routinely taken blood plasma samples from 67 critically ill patients. Although relying on a spectral range from 1030 cm(-1) to 1230 cm(-1), which is optimal for glucose and lactate but rather unusual for protein analysis, it was possible to selectively determine the albumin and total protein concentrations with sufficient accuracy for POC application.


Asunto(s)
Técnicas Biosensibles/métodos , Láseres de Semiconductores , Plasma/química , Sistemas de Atención de Punto , Espectrofotometría Infrarroja/métodos , Algoritmos , Calibración , Humanos , Análisis de los Mínimos Cuadrados