Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Arch Orthop Trauma Surg ; 141(4): 593-602, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32519074

RESUMEN

BACKGROUND: Navigational techniques in orthopaedic trauma surgery have developed over the last years leaving the question of really improving quality of treatment. Especially in marginal surgical indications, their benefit has to be evident. The aim of this study was to compare reduction and screw position following 3D-navigated and conventional percutaneous screw fixation of acetabular fractures. The study hypothesis postulated that better fracture reduction and better screw position are obtained with 3D navigation. MATERIALS AND METHODS: Preoperative and postoperative CT scans of 37 acetabular fractures treated by percutaneous screw fixation (24 3D-navigated, 13 conventional) were evaluated. Differences in pre- and postoperative fracture gaps and steps were compared in all reconstructions as well as the screw position relative to the joint and the fracture. RESULTS: The differences in fracture gaps and fracture steps with and without 3D navigation were not significantly different. Distance of the screw from the joint line, angle difference between screw and ideal angle relative to the fracture line, length of the possible corridor used and position of the screw thread did not show any significant differences. CONCLUSION: Comparison of 3D-navigated and conventional percutaneous surgery of acetabular fractures on the basis of pre- and postoperative CTs revealed no significant differences in terms of fracture reduction and screw position.


Asunto(s)
Acetábulo , Tornillos Óseos , Fijación de Fractura/métodos , Fracturas Óseas , Cirugía Asistida por Computador/métodos , Acetábulo/diagnóstico por imagen , Acetábulo/lesiones , Acetábulo/cirugía , Fluoroscopía , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Humanos , Imagenología Tridimensional
2.
Unfallchirurg ; 123(11): 849-855, 2020 Nov.
Artículo en Alemán | MEDLINE | ID: mdl-33034666

RESUMEN

BACKGROUND: Numerous processes are involved in the orthopedic and trauma surgery operating room (OR). Technical progress, particularly in the area of digitalization, is increasingly changing routine surgical procedures. OBJECTIVE: This article highlights the possibilities and also limitations regarding this matter. MATERIAL AND METHODS: Based on the current literature this article provides insights into innovations in the areas of digitalization of surgical devices, hybrid OR, machine-2-machine networking, management systems for perioperative efficiency improvement, 3D printing technology and robotics. RESULTS: The technical possibilities for the use of digital applications in the surgical environment are rapidly increasing. Close cooperation with industrial partners is important in this context. Technologies from the automotive, gaming and mobile phone industries are being adopted. CONCLUSION: Digital technology in the OR can improve treatment quality, patient and staff safety and cost efficiency; however, the networking of devices, implementation of innovations in existing structures and the sometimes high acquisition costs are still limiting factors.


Asunto(s)
Quirófanos , Ortopedia , Robótica , Humanos , Impresión Tridimensional
3.
Unfallchirurg ; 120(Suppl 1): 10-18, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27659309

RESUMEN

BACKGROUND: Percutaneous internal fixation of pelvic fractures is increasing in popularity with multiple new techniques reported. OBJECTIVES: The purpose of this article is to outline the imaging, indication, planning, equipment, surgical technique and complications of these methods. METHODS: A review of the literature is provided and the techniques for anterior and posterior pelvic stabilisation are discussed. RESULTS: High-quality preoperative CT scans are essential in planning for this technique. The anterior internal fixator ("InFix") is an effective method for stabilising the anterior ring and should be usually used in conjunction with posterior fixation. Good technique avoids neurovascular injury, which can be a devastating complication. The retrograde anterior column screw (RACS) is a technique that can be used in most patients, although in smaller patients smaller screw diameters may be needed. The entry point for the screw is more lateral in women than men. Iliosacral screws (ISS) are an effective method of posterior stabilisation and can be placed using 2D or 3D fluoroscopy, computer navigation or CT navigation. CONCLUSION: Percutaneous fixation of pelvic fractures requires high-quality imaging and can be aided by computer navigation. Safe techniques are reproducible; however, not all patients and fracture patterns can be treated using these techniques.


Asunto(s)
Fijación Interna de Fracturas/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Huesos Pélvicos/lesiones , Fijación Interna de Fracturas/instrumentación , Humanos , Huesos Pélvicos/diagnóstico por imagen , Huesos Pélvicos/cirugía , Complicaciones Posoperatorias/etiología , Equipo Quirúrgico
4.
Unfallchirurg ; 119(10): 825-34, 2016 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-27659308

RESUMEN

BACKGROUND: Percutaneous internal fixation of pelvic fractures is increasing in popularity with multiple new techniques reported. OBJECTIVES: The purpose of this article is to outline the imaging, indication, planning, equipment, surgical technique and complications of these methods. METHODS: A review of the literature is provided and the techniques for anterior and posterior pelvic stabilization are discussed. RESULTS: High-quality preoperative CT scans are essential in planning for this technique. The anterior internal fixator ("InFix") is an effective method for stabilizing the anterior ring and should be usually used in conjunction with posterior fixation. Good technique avoids neurovascular injury, which can be a devastating complication. The retrograde anterior column screw (RACS) is a technique that can be used in most patients, although in smaller patients smaller screw diameters may be needed. The entry point for the screw is more lateral in women than men. Iliosacral screws (ISS) are an effective method of posterior stabilization and can be placed using 2D or 3D fluoroscopy, computer navigation or CT navigation. CONCLUSION: Percutaneous fixation of pelvic fractures requires high-quality imaging and can be aided by computer navigation. Safe techniques are reproducible; however, not all patients and fracture patterns can be treated using these techniques.


Asunto(s)
Fijación Interna de Fracturas/métodos , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Huesos Pélvicos/lesiones , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Medicina Basada en la Evidencia , Fijación Interna de Fracturas/instrumentación , Alemania , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Huesos Pélvicos/diagnóstico por imagen , Huesos Pélvicos/cirugía , Resultado del Tratamiento
5.
Unfallchirurg ; 119(10): 803-10, 2016 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-27599821

RESUMEN

BACKGROUND: The results and immediate consequences of intraoperative three-dimensional (3D) imaging in the treatment of AO classification type C fractures of the distal radius, the tibial head and the tibial pilon were analyzed and compared with published results on general intraoperative revision rates following intraoperative 3D-imaging. METHODS: In this retrospective study 279 patients with AO type C fractures of the distal radius (n = 84), tibial head (n = 109) and tibial pilon (n = 86) who underwent intraoperative 3D-imaging were included. The findings of the 3D-imaging and the intraoperative revision rates were analyzed and compared with previously published results of our working group. RESULTS: In 70 out of 279 patients (25 %) an intraoperative revision was carried out following 3D-imaging. The revision rates were 15 % for fractures of the distal radius, 27 % for fractures of the tibial head and 32 % for fractures of the tibial pilon. The most common reason for immediate intraoperative revision was the necessity for improved repositioning due to a remaining step in the articular surface in 51 out of 279 patients (18%). CONCLUSION: Intraoperative revision rates following 3D-imaging increased with the severity of the injury pattern. Intraoperative 3D-imaging should be routinely used in the treatment of fractures of the tibial head, tibial pilon and even in comminuted distal radius fractures due to the high intraoperative revision rates found in the present study. Alternatively, a postoperative computed tomography (CT) control should be performed.


Asunto(s)
Fijación Interna de Fracturas/estadística & datos numéricos , Imagenología Tridimensional/estadística & datos numéricos , Fracturas del Radio/cirugía , Reoperación/estadística & datos numéricos , Cirugía Asistida por Computador/estadística & datos numéricos , Fracturas de la Tibia/cirugía , Femenino , Alemania/epidemiología , Humanos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/prevención & control , Prevalencia , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/epidemiología , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo , Sensibilidad y Especificidad , Cirugía Asistida por Computador/métodos , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/epidemiología , Resultado del Tratamiento
6.
Injury ; 48(10): 2068-2073, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28774707

RESUMEN

PURPOSE: A new software application can be used without fixed reference markers or a registration process in wire placement. The aim was to compare placement of Kirschner wires (K-wires) into the proximal femur with the software application versus the conventional method without guiding. As study hypothesis, we assumed less placement attempts, shorter procedure time and shorter fluoroscopy time using the software. The same precision inside a proximal femur bone model using the software application was premised. METHODS: The software detects a K-wire within the 2D fluoroscopic image. By evaluating its direction and tip location, it superimposes a trajectory on the image, visualizing the intended direction of the K-wire. The K-wire was positioned in 20 artificial bones with the use of software by one surgeon; 20 bones served as conventional controls. A brass thumb tack was placed into the femoral head and its tip targeted with the wire. Number of placement attempts, duration of the procedure, duration of fluoroscopy time and distance to the target in a postoperative 3D scan were recorded. RESULTS: Compared with the conventional method, use of the application showed fewer attempts for optimal wire placement (p=0.026), shorter duration of surgery (p=0.004), shorter fluoroscopy time (p=0.024) and higher precision (p=0.018). Final wire position was achieved in the first attempt in 17 out of 20 cases with the software and in 9 out of 20 cases with the conventional method. CONCLUSIONS: The study hypothesis was confirmed. The new application optimised the process of K-wire placement in the proximal femur in an artificial bone model while also improving precision. Benefits lie especially in the reduction of placement attempts and reduction of fluoroscopy time under the aspect of radiation protection. The software runs on a conventional image intensifier and can therefore be easily integrated into the daily surgical routine.


Asunto(s)
Fracturas del Fémur/diagnóstico por imagen , Fémur/diagnóstico por imagen , Fijación Interna de Fracturas , Cirugía Asistida por Computador/métodos , Órganos Artificiales , Hilos Ortopédicos , Huesos/diagnóstico por imagen , Huesos/cirugía , Fracturas del Fémur/cirugía , Fémur/anatomía & histología , Fémur/cirugía , Fluoroscopía , Fijación Interna de Fracturas/métodos , Humanos , Modelos Anatómicos , Tempo Operativo , Reproducibilidad de los Resultados , Programas Informáticos
7.
Eur J Trauma Emerg Surg ; 39(5): 517-22, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26815450

RESUMEN

BACKGROUND: With over 2 million certified physicians worldwide, the Advanced Trauma Life Support (ATLS) program is one of the most successful international medical education programs. Germany joined the ATLS program in 2003. Before implementation of the program, there was a controversial discussion as to whether a country like Germany with a long history of trauma care needed ATLS at all. 197 courses with nearly 3,000 providers were performed until December 2010. AIM: We assessed the course evaluations since the implementation of ATLS in Germany using the participants' systematic feedback. METHOD: During the course, each participant evaluated each presentation, skill station, and simulation on a rating scale from 1 to 4 (1 being the best, 4 being the worst). The participants completed the evaluation forms during the course and before they received their results. The course coordinator made sure that all forms were returned. The feedback forms were collected anonymously and were entered into a database. Statistical analysis was performed using frequencies and mean values. RESULTS: The cumulative evaluation of all courses revealed an average performance score of 1.39 (1.06-1.86; n = 197). The lectures, skill stations, and simulations were individually evaluated as follows: lectures 1.61 (1.00-2.81; n = 197), skill stations 1.40 (1.00-2.40; n = 197), and surgical skill stations 1.35 (1.00-2.38; n = 197). Practical skills simulation (case scenarios) received the highest grade of 1.24 (1.00-1.57; n = 197). There were no significant changes during the time concerning the results of the evaluation. CONCLUSION: The overall assessment showed constantly good and excellent evaluations by the participants over the years. In general, skill stations and simulations performed better than lectures. According to these results, the course format is well accepted by the participants and, therefore, can be recommended to all physicians treating trauma patients. Our results also underline the value of such a course format in an industrial country with an already established trauma system.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA