RESUMEN
Ventricular septal defect (VSD) is a severe complication of myocardial infarction (MI) with a high mortality rate. We report a case of a large post-MI VSD treated with percutaneous venoarterial extracorporeal membrane oxygenation (VA-ECMO) to restore hemodynamic stability and to avoid surgery in the acute setting. VSD closure with endoventricular patch and implantation of biventricular assist device (BiVAD) was arranged sixteen days after MI. Because of no signs of myocardial recovery, implantation of durable left ventricular assist device (LVAD) as a bridge to transplant was provided, leaving right ventricular assist device (RVAD) to right ventricle recovery. RVAD was explanted 18 days after durable LVAD placement and the patient was discharged home two months after MI. The use of durable LVAD is a unique solution that can be applied in selected patients with MI-VSD and heart failure.
Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Defectos del Tabique Interventricular , Corazón Auxiliar , Infarto del Miocardio , Insuficiencia Cardíaca/terapia , Defectos del Tabique Interventricular/cirugía , Humanos , Infarto del Miocardio/complicaciones , Resultado del TratamientoRESUMEN
A 53-year-old female with idiopathic hypereosinophilic syndrome underwent recurrent tricuspid valve replacement for Löffler's endocarditis. We review the literature on tricuspid valve surgery in patients with this uncommon disorder.
Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Síndrome Hipereosinofílico/complicaciones , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Eosinofilia/prevención & control , Femenino , Humanos , Masculino , Persona de Mediana Edad , Atención Perioperativa , Complicaciones Posoperatorias/prevención & control , Trombosis/prevención & control , Resultado del TratamientoRESUMEN
Left ventricular assist devices (LVADs) are increasingly used as a treatment option for advanced heart failure. Fungal infections present a serious concern given the high association with major adverse events including death in this group of patients. The objective of this review is to summarize the incidence, risk factors, method for diagnosis, complication rate, and outcomes in patients with VADs who develop fungal infections.
Asunto(s)
Corazón Auxiliar/efectos adversos , Corazón Auxiliar/microbiología , Micosis/etiología , Antifúngicos/administración & dosificación , Aspergilosis , Candidiasis , Fluconazol/administración & dosificación , Insuficiencia Cardíaca/terapia , Humanos , Incidencia , Micosis/diagnóstico , Micosis/epidemiología , Micosis/terapia , Pirimidinas/administración & dosificación , Factores de Riesgo , Factores de Tiempo , Triazoles/administración & dosificación , VoriconazolRESUMEN
A 67-year-old male with a history of gastrointestinal malignancy was found to have a tumor in the right ventricular outflow tract. The tumor was surgically removed, and the histological diagnosis was thyroid struma. We review the literature on this rare cardiac tumor.
Asunto(s)
Coristoma/cirugía , Cardiopatías/cirugía , Ventrículos Cardíacos , Glándula Tiroides , Anciano , Coristoma/diagnóstico , Coristoma/patología , Ecocardiografía Tridimensional , Cardiopatías/diagnóstico , Cardiopatías/patología , Humanos , Imagen por Resonancia Magnética , Masculino , Resultado del TratamientoRESUMEN
Prior research has suggested that GATA6+ pericardial macrophages may traffic to the myocardium to prevent interstitial fibrosis after myocardial infarction (MI), while subsequent literature claims that they do not. We demonstrate that GATA6+ pericardial macrophages are critical for preventing IL-33 induced pericarditis and attenuate trafficking of inflammatory monocytes and granulocytes to the pericardial cavity after MI. However, absence of GATA6+ macrophages did not affect myocardial inflammation due to MI or coxsackievirus-B3 induced myocarditis, or late-stage cardiac fibrosis and cardiac function post MI. GATA6+ macrophages are significantly less transcriptionally active following stimulation in vitro compared to bone marrow-derived macrophages and do not induce upregulation of inflammatory markers in fibroblasts. This suggests that GATA6+ pericardial macrophages attenuate inflammation through their interactions with surrounding cells. We therefore conclude that GATA6+ pericardial macrophages are critical in modulating pericardial inflammation, but do not play a significant role in controlling myocardial inflammation or fibrosis.
RESUMEN
BACKGROUND: Double valve replacement for concomitant aortic and mitral valve disease is associated with substantial morbidity and mortality. Excellent results with valve repair in isolated mitral valve lesions have been reported; therefore, whether its potential benefits would translate into better outcomes in patients with combined mitral-aortic disease was investigated. METHODS: A retrospective observational study was performed involving 341 patients who underwent aortic valve replacement with either mitral valve repair (n=42) or double valve replacement (n=299). Data were analyzed for early mortality, late valve-related complications and survival. RESULTS: The early mortality rate was 11.9% for valve repair and 11.0% for replacement (P=0.797). Survival (± SD) was 67±11% in mitral valve repair with aortic valve replacement and 81±3% in double valve replacement at five years of follow-up (P=0.187). The percentage of patients who did not experience major adverse valve-related events at five years of follow-up was 83±9% in those who underwent mitral valve repair with aortic valve replacement and 89±2% in patients who underwent double valve replacement (P=0.412). Age >70 years (HR 2.4 [95% CI 1.1 to 4.9]; P=0.023) and renal dysfunction (HR 1.9 [95% CI 1.2 to 3.7]; P=0.01) were independent predictors of decreased survival. CONCLUSIONS: In patients with double valve disease, both mitral valve repair and replacement provided comparable early outcomes. There were no significant differences in valve-related reoperations, anticoagulation-related complications or prosthetic valve endocarditis. Patient-related factors appear to be the major determinant of late survival, irrespective of the type of operation.
RESUMEN
The present case report demonstrates a development of a false aneurysm in a venous coronary bypass graft wall, which developed at the previous MGuard stent implantation area in a 67-year-old patient. Subsequent histological examination revealed a false aneurysm image, without detection of vascular wall layers in its wall. Microscopically mild neointimal proliferation within the stent was also detected, with a strong granulomatous inflammatory reaction, mostly focused on the PET fibre mesh present on the surface of the stent. This article demonstrates the need for a multidisciplinary approach in dealing with pathological changes in stented blood vessels; the authors would also like to remind the public of the possibility of histological examination of stented vessels in the Czech Republic.
Asunto(s)
Aneurisma Falso/patología , Puente de Arteria Coronaria/efectos adversos , Stents/efectos adversos , Venas/patología , Anciano , República Checa , Humanos , Masculino , MicroscopíaAsunto(s)
Trasplante de Corazón , Corazón Auxiliar , Trombosis Intracraneal/diagnóstico por imagen , Trombosis Intracraneal/cirugía , Trombectomía/métodos , Disfunción Ventricular/terapia , Listas de Espera , Adulto , Angiografía de Substracción Digital , Angiografía por Tomografía Computarizada , Humanos , Infarto de la Arteria Cerebral Media/diagnóstico por imagen , Infarto de la Arteria Cerebral Media/etiología , Infarto de la Arteria Cerebral Media/cirugía , Trombosis Intracraneal/etiología , Masculino , Stents , Resultado del Tratamiento , Disfunción Ventricular/complicacionesRESUMEN
BACKGROUND: Aortic dissection in a cardiac allograft is an uncommon complication of heart transplantation with only few cases reported in the literature. METHOD: We report a case of 46-year-old female who underwent orthotopic heart transplantation for dilated cardiomyopathy 22 years earlier. During surveillance echocardiographic examination she was diagnosed with type A aortic dissection limited to the donor aorta. The aortic root was successfully replaced using a valve-sparing David procedure. The pathogenesis and surgical management of these dissections is reviewed. CONCLUSION: Appropriate surgical repair performed in a timely fashion leads to excellent results improving the prognosis of these patients.
Asunto(s)
Rotura de la Aorta/etiología , Cardiomiopatía Dilatada/cirugía , Trasplante de Corazón , Complicaciones Posoperatorias , Rotura de la Aorta/diagnóstico , Rotura de la Aorta/cirugía , Femenino , Humanos , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/cirugíaRESUMEN
BACKGROUND: Prevalence of terminal forms of heart failure is steadily increasing and thus waiting time for heart transplantation, too. Increasing mortality on waiting list has urged implementation of mechanical circulatory support as an adjunct to the programme of heart transplantation. The objective of the study is to review 7-years experience with paracorporeal assist device in bridging to transplantation. MATERIAL AND METHODS: Retrospective review of 53 transplant candidates treated since April 2003. 50 patients received paracorporeal assist devices in biventricular configuration. Most frequent diagnosis was dilated cardiomyopathy in 51%. RESULTS: Despite a high risk profile of the patients, 37 of them were successfully transplanted (69.8%). Cumulative support has reached 3513 days. Local exit sites infection was identified as a most frequent complication, sepsis as a most frequent cause of death on support (18.8%). 30-days post-transplant mortality remained low at 5.7%. CONCLUSIONS: Paracorporeal mechanical circulatory assist devices remain effective alternative for terminal stage heart transplant candidates, especially for those in multiorgan failure who require biventricular support. Success rate of bridging to transplantation is acceptable, as well as complications rate and quality of life while on support. Long-term post-transplant survival is not inferior to the results of procedures performed without necessity of previous implantation of the assist device.
Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Insuficiencia Multiorgánica/terapia , Adolescente , Adulto , Anciano , Femenino , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/fisiopatología , Trasplante de Corazón , Corazón Auxiliar/efectos adversos , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia Multiorgánica/complicaciones , Adulto JovenRESUMEN
AIMS: Recipients of left ventricular assist devices (LVAD) are exposed to increased risk of adverse clinical events. One of the potential contributing factors is non-pulsatile flow generated by LVAD. We evaluated the association of flow patterns in carotid arteries and of increased arterial stiffness with death and cerebrovascular events in LVAD recipients. METHODS AND RESULTS: We analysed data from 83 patients [mean age 54 ± 15 years; 12 women; HeartMate II (HMII), n = 34; HeartMate 3 (HM3), n = 49]. Pulsatile and resistive indexes, atherosclerotic changes in carotid arteries (measured by duplex ultrasound), and arterial stiffness [measured by Endo-PAT 2000 as the augmentation index standardized for heart rate (AI@75)] were evaluated 3 and 6 months after LVAD implantation. Sixteen patients died during follow-up (27.3 months; interquartile range 15.7-44.3). After adjusting for the main variables examined, the pulsatility index measured at 3 months was positively associated with increased hazard ratios (HR) for death and cerebrovascular events [HR 9.8, 95% confidence interval (CI) 1.62-59.42], with HR increasing after adding AI@75 to the model (HR 18.8, 95% CI 2.44-145.50). In HM3 recipients, HR was significantly lower than in HMII recipients (HR 0.31, 95% CI 0.11-0.91), but the significance disappeared after adding AI@75 to the model (HR 0.33, 95% CI 0.09-1.18). CONCLUSIONS: The risk of death and cerebrovascular events in LVAD recipients is associated with increased pulsatility index in carotid arteries and potentiated by increased arterial stiffness. The same risk is attenuated by HM3 LVAD implantation, but this effect is weakened by increased arterial stiffness.
Asunto(s)
Aterosclerosis , Insuficiencia Cardíaca , Corazón Auxiliar , Adulto , Anciano , Femenino , Humanos , Persona de Mediana Edad , Resultado del TratamientoRESUMEN
BACKGROUND: Implantation of left-ventricular assist systems (LVASs) has become the standard of care for advanced heart failure (HF). The absence of pulsatility in previous devices contributes to vascular and endothelial dysfunction related to atherosclerotic or vascular complications. We hypothesized that the artificial pulsatility provided by the HeartMate 3 (HM3) (Abbott, Chicago, IL) LVAS would exert a favourable effect on the vasculature. METHODS: In 32 patients implanted with HM3 (5 female patients, mean age 55 ± 13.6 years), the reactive hyperemia index (RHI) and peripheral augmentation index (AI), markers of endothelial function and arterial stiffness, were measured with an EndoPAT2000 before and in the third and sixth month after implantation. RHI and AI data from 30 HeartMate II (HM II) (Abbott) recipients in the third and sixth month after implantation, from 15 patients with advanced HF without LVASs and from 13 healthy volunteers were also analyzed. RESULTS: In HM3 recipients, the mean RHI significantly decreased at 3 and 6 months after implantation. The RHI was substantially lower at baseline than that of healthy or the HF reference group. Increasing AI values, indicating worsening arterial stiffness, were also observed. Similar trends were observed in HM II recipients between the third and sixth months but with higher absolute values of RHI and AI. CONCLUSIONS: We detected impaired vascular function in HM3 patients and provided additional evidence on the negative effect of low pulsatility on vascular function after LVAS implantation. The results suggest that the artificial pulsatility of the HM3 does not avert the progression of endothelial dysfunction.
Asunto(s)
Arterias/fisiopatología , Endotelio Vascular/fisiopatología , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/fisiopatología , Corazón Auxiliar , Resistencia Vascular/fisiología , Función Ventricular Izquierda/fisiología , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de TiempoRESUMEN
INTRODUCTION: Inherited thrombophilias represent a concerning risk factor due to a proclivity to an aberrant clot formation. However, in patients with left ventricular assist device (LVAD), their impact on bleeding and thrombotic complications remains still poorly understood. The aim of the present study was to evaluate the effect of thrombophilic mutation directed anticoagulation therapy on adverse clinical outcomes in LVAD patients. MATERIALS AND METHODS: About 138 consecutive patients indicated for LVAD implant (HeartMate II, Abbott, Plymouth, USA) were prospectively screened for three major thrombophilic mutations: factor II (prothrombin), factor V Leiden, and homozygous methylenetetrahydrofolate reductase (MTHFR). Subsequently, discordant individualized anticoagulation targets of INR 2.5-3.0 in thrombophilia positive and INR 1.8-2.2 in negative patients were established; notably without anti-platelet agents given the center standard of care. RESULTS: Mean age was 50 ± 12.7 years, 83% male. Mean duration of support was 464.5 days (SD 482.9; SEM 41.1) and median of 310 days (IQR 162; 546). Full thrombophilia positive cohort analysis has not revealed any significant impact on event free survival. In contrast, detailed analysis of specific thrombophilias subsets has revealed Factor II prothrombin mutation as a significant predisposition for the pump thrombosis risk (SHR 10.48; p = 0.001) despite more aggressive prespecified anticoagulation target. Moreover, the incidence of bleeding events in prothrombin group was also significantly increased (SHR 6.0; p = 0.03). CONCLUSIONS: Our observations suggest that specific thrombophilias in LVAD patients may pose different intensity predisposition for thrombotic complications. Factor II (prothrombin) positive mutation was identified as significant risk factor associated with the pump thrombosis.
Asunto(s)
Corazón Auxiliar , Trombofilia , Trombosis , Adulto , Femenino , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Protrombina , Trombofilia/diagnóstico , Trombofilia/genética , Trombosis/genéticaRESUMEN
The use of short-term mechanical circulatory support during postcardiotomy acute heart failure provides an opportunity to stabilize the patient's hemodynamic state while determining the best long-term strategy. Because all of these devices require anticoagulation treatment of various intensities, management of major bleeding can be critical for the overall outcome of the therapy. In this regard, the newest generation of magnetically levitated centrifugal-flow pumps affords several potential advantages in terms of thrombogenicity and eventual discontinuation of anticoagulation treatment. We report the use of a short-term biventricular assist device (Levitronix CentriMag) for 94 days in a 55-year-old man with refractory ventricular arrhythmias after combined heart surgery. Despite serious complications while the patient was on the assist device, including severe intestinal bleeding with the necessity of discontinuing anticoagulation for 10 days and, ultimately, hemicolectomy, the circulatory support was completed with successful heart transplantation.
Asunto(s)
Anticoagulantes/uso terapéutico , Hemorragia Gastrointestinal/tratamiento farmacológico , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Enfermedades Intestinales/tratamiento farmacológico , Hemorragia Gastrointestinal/complicaciones , Humanos , Enfermedades Intestinales/complicaciones , Masculino , Persona de Mediana EdadRESUMEN
Renal insufficiency is common in patients with chronic heart failure. There are two pathologic processes involved in etiology of this type of renal insufficiency: first is the decrease in end organ perfusion as a result of reduction in cardiac output of the failing heart, second is the vascular nephrosclerosis resulting from atherosclerosis as part of the underlying disease process. This paper outlines the benefit of mechanical assist device implantation in improving renal function. After a rapid improvement of renal functions after biventricular assist device implantation in our patient with dilated cardiomyopathy we were able to avoid combined heart and kidney transplant and proceed with an isolated heart transplant.
Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Insuficiencia Renal/fisiopatología , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia Renal/etiologíaRESUMEN
We find that cardiac group 2 innate lymphoid cells (ILC2s) are essential for the development of IL-33-induced eosinophilic pericarditis. We show a pathogenic role for ILC2s in cardiac inflammation, in which ILC2s activated by IL-33 drive the development of eosinophilic pericarditis in collaboration with cardiac fibroblasts. ILCs, not T and B cells, are required for the development of pericarditis. ILC2s transferred to the heart of Rag2-/-Il2rg-/- mice restore their susceptibility to eosinophil infiltration. Moreover, ILC2s direct cardiac fibroblasts to produce eotaxin-1. We also find that eosinophils reside in the mediastinal cavity and that eosinophils transferred to the mediastinal cavity of eosinophil-deficient ΔdblGATA1 mice following IL-33 treatment migrate to the heart. Thus, the serous cavities may serve as a reservoir of cardiac-infiltrating eosinophils. In humans, patients with pericarditis show higher amounts of ILCs in pericardial fluid than do healthy controls and patients with other cardiac diseases. We demonstrate that ILCs play a critical role in pericarditis.
Asunto(s)
Inmunidad Innata , Linfocitos/inmunología , Pericarditis/inmunología , Animales , Movimiento Celular/efectos de los fármacos , Quimiocina CCL11/genética , Quimiocina CCL11/metabolismo , Susceptibilidad a Enfermedades , Eosinófilos/efectos de los fármacos , Eosinófilos/patología , Femenino , Fibroblastos/efectos de los fármacos , Fibroblastos/metabolismo , Regulación de la Expresión Génica/efectos de los fármacos , Corazón/efectos de los fármacos , Corazón/fisiopatología , Pruebas de Función Cardíaca/efectos de los fármacos , Humanos , Inmunidad Innata/efectos de los fármacos , Proteína 1 Similar al Receptor de Interleucina-1/deficiencia , Proteína 1 Similar al Receptor de Interleucina-1/metabolismo , Interleucina-33/farmacología , Interleucina-5/metabolismo , Linfocitos/efectos de los fármacos , Masculino , Mediastino/patología , Ratones Endogámicos BALB C , Pericarditis/genética , Pericarditis/fisiopatología , Transducción de Señal/efectos de los fármacos , Regulación hacia Arriba/efectos de los fármacosRESUMEN
BACKGROUND: Left atrial surgical radiofrequency ablation represents an applicable and technically less demanding method for treating paroxysmal or permanent atrial fibrillation (AF) as a concomitant procedure. The aim of this study was to review the long-term outcomes of radiofrequency linear ablation for the treatment of AF limited to the left atrium in 3 groups of patients undergoing cardiac surgery. METHODS: The study population consisted of 357 consecutive patients, who were divided into 3 groups on the basis of the underlying disease: group I, 126 patients with nonischemic mitral valve disease; group II, 164 patients with coronary artery disease and aortic and/or ischemic mitral valve disease or who underwent other concomitant procedures; and group III, 67 patients with coronary artery disease only. RESULTS: Follow-up times were between 6 and 48 months (mean, 28.3 + 9.4 months). The 30-day hospital mortality rate was 2.80% (10 patients). Total mortality during the follow-up period reached 4.48% (16 patients). At discharge, 66% of group I patients, 64% of group II patients, and 69% of group in patients were in sinus rhythm. After 24 months, 60% of group I patients, 75% of group II patients, and 67% of group III patients were in sinus rhythm. A subgroup analysis of the patients with permanent AF showed that only 54% of these patients in group I, 52% in group II, and 67% in group III had a restored sinus rhythm at 24 months. Subgroup analysis also revealed that only 6 (27%) of 22 patients with a left atrium diameter >60 mm maintained a sinus rhythm during long-term follow-up. Biatrial contraction was restored in 75% of the patients with a stable sinus rhythm after 6 months of follow-up. Seven patients (2%) with symptomatic postoperative recurrent atrial arrhythmias underwent subsequent catheter ablation. CONCLUSION: Left atrial surgical radiofrequency ablation represents an applicable and technically less demanding method for treating paroxysmal or permanent AF as a concomitant procedure. Our results demonstrate the feasibility of this procedure for paroxysmal and persistent AF, with minimal risks to the patient. For permanent AF, further investigation and extensive intervention are essential.
Asunto(s)
Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/estadística & datos numéricos , Enfermedad de la Arteria Coronaria/epidemiología , Enfermedad de la Arteria Coronaria/cirugía , Enfermedades de las Válvulas Cardíacas/epidemiología , Enfermedades de las Válvulas Cardíacas/cirugía , Fibrilación Atrial/diagnóstico , Comorbilidad , República Checa/epidemiología , Femenino , Humanos , Estudios Longitudinales , Masculino , Prevalencia , Resultado del TratamientoRESUMEN
BACKGROUND: The HeartMate 3 left ventricular assist system is engineered to avoid pump thrombosis, yet bleeding complications persist. We investigated the safety of low-intensity anti-coagulation in patients with the HeartMate 3. METHODS: The Minimal AnticoaGulation EvaluatioNTo aUgment heMocompatibility (MAGENTUM 1) pilot study is a prospective, single-arm study of low-intensity warfarin anti-coagulation in patients implanted with the HeartMate 3 pump. After standard warfarin anti-coagulation (international normalized ratio [INR] 2.0 to 3.0) and aspirin for 6 weeks post-implant, patients were transitioned to a lower INR target range of 1.5 to 1.9. The primary end-point was a composite of survival free of pump thrombosis, disabling stroke (modified Rankin score [MRS] >3), or major bleeding (excluding peri-operative bleeding) with at least 6-month post-implant follow-up. Time in therapeutic range (TTR) was measured to assess anti-coagulation target efficacy using the Rosendaal method. A safety algorithm to monitor for signs of pump thrombosis was developed and implemented. RESULTS: We enrolled 15 patients (mean age 57.3 ± 13.3 years), 13 men with advanced heart failure (67% with INTERMACS Profiles 2 or 3), irrespective of therapeutic goal of bridge-to-transplant or destination therapy. The primary end-point was met in 14 of 15 (93 ± 6%) patients; 1 patient developed recurrent gastrointestinal bleeding. The TTR during the reduced anti-coagulation phase (6 weeks to 6 months) was 75.3 ± 8.6%. No thrombotic events occurred. CONCLUSIONS: This pilot study suggests low-intensity anti-coagulation targeting an INR between 1.5 and 1.9 is achievable and safe with the HeartMate 3 cardiac pump in the short-term phase, 6-months post-implant. A large-scale trial is now warranted.