1.
J AOAC Int ; 93(2): 622-7, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20480910

RESUMEN

An AOAC collaborative study was conducted to evaluate an affinity LC procedure for measuring immunoglobulin G (IgG) in selected dairy powders. The powders were extracted with 0.15 M sodium chloride solution and the pH was adjusted to 4.6 to precipitate caseins, which would otherwise lead to an overestimation of IgG. The analyte was then bound to a commercially available Protein G affinity cartridge and selectively eluted with a glycine buffer at pH 2.5. Detection was at 280 nm and quantification was made against a calibration curve prepared from bovine serum IgG. The samples analyzed included the likely matrixes for which this assay will find commercial use, namely, high- and low-protein-content colostrum powders, tablets containing colostrum powder, and some IgG-containing dairy powders; milk protein isolate, whey protein concentrate, and skim milk powder. Eleven laboratories provided data for the study and assayed blind duplicates of six materials. The repeatability RSD values ranged from 2.1 to 4.2% and the reproducibility RSD values ranged from 6.4 to 18.5%. The Protein G method with casein removal has adequate reproducibility for measuring IgG in colostrum-derived powders that are traded on the basis of IgG content as a colostral marker.


Asunto(s)
Técnicas de Química Analítica , Cromatografía Liquida/métodos , Calostro/metabolismo , Inmunoglobulina G/análisis , Leche/metabolismo , Proteínas del Tejido Nervioso/química , Animales , Biomarcadores , Calibración , Bovinos , Concentración de Iones de Hidrógeno , Inmunoglobulina G/química , Polvos , Reproducibilidad de los Resultados , Factores de Tiempo
2.
J AOAC Int ; 88(1): 5-15, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15759720

RESUMEN

In 1996, U.S. Food and Drug Administration regulations mandated the fortification of enriched cereal-grain products with folic acid, thereby emphasizing the need for validated methods for total folates in foods, particularly cereal products. The AOAC Official Methods (944.12, 960.46) currently used for the analysis of folate in foods for compliance purposes are microbiological methods. When the fortification regulations were finalized, no Official AOAC or Approved AACC methods for folate in cereal-grain products were in place. The AOAC Official Method (992.05) for folic acid in infant formula does not incorporate important improvements in the extraction procedure and was not considered suitable for the analysis of folates in foods in general. A microbiological assay protocol using a trienzyme extraction procedure was prepared and submitted for comments to 40 laboratories with recognized experience in folate analysis. On the basis of comments, the method was revised to have the conjugase (gamma-glutamyl-carboxy-peptidase) treatment follow a protease treatment, to include the use of cryoprotected inoculum, and to include the spectroscopic standardization of the standard and optional use of microtiter plates. Thirteen laboratories participated in a collaborative study of 10 required and 10 optional cereal-grain products, including flour, bread, cookies, baking mixes, and ready-to-eat breakfast cereals. The majority of the participating laboratories performed the assay by the standard test tube method; others used the microtiter plate modification for endpoint quantitation with equal success. For the required products, the relative standard deviation between laboratories (RSD(R)) ranged from 7.4 to 21.6% for 8 fortified (or enriched) products compared with expected (Horwitz equation-based) values of 11-20%. RSD(R) values were higher (22.7-52.9%) for 2 unfortified cereal-grain products. For the optional products, the RSD(R) ranged from 1.8 to 11.2% for 8 fortified products. RSD(R) values were higher (27.9-28.7%) for 2 unfortified cereal-grain products. Based on the results of the collaborative study, the microbiological assay with trienzyme extraction is recommended for adoption as Official First Action.


Asunto(s)
Técnicas de Química Analítica/métodos , Grano Comestible/metabolismo , Análisis de los Alimentos/métodos , Alimentos Fortificados , Lactobacillus/metabolismo , Espectrofotometría/métodos , Automatización , Pan , Ácido Fólico/análisis , Ácido Fólico/química , Deficiencia de Ácido Fólico/prevención & control , Guías como Asunto , Humanos , Concentración de Iones de Hidrógeno , Laboratorios , Nefelometría y Turbidimetría , Política Nutricional , Oxígeno/metabolismo , Control de Calidad , Reproducibilidad de los Resultados