Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Acta Oncol ; 59(10): 1139-1144, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32536238

RESUMEN

INTRODUCTION: On 15-16 November 2019, the Skandion Clinic in Sweden hosted the first Nordic workshop on 'Patients' perspective in proton beam therapy'. The workshop was conducted to describe and compare the patient care in PBT clinics in the Nordic countries and to initiate a collaboration, with the target to ensure patient participation and reduce the risk of inequity of access by lowering the barriers for accepting PBT in a distant clinic. The overarching aim of this workshop was to describe and compare the use of patients' perspectives in the Nordic PBT clinics. MATERIAL AND METHODS: Twelve participants attended the workshop, representing Denmark, Norway and Sweden. The participants were registered nurses working in patient care, researchers, physicist and leaders of the Skandion Clinic. RESULTS: The consensus of the workshop was that systematic use of patient experiences on individual and group level is essential for developing clinical practice and understanding the overall effects of PBT. A difference in how the Nordic countries use patient experiences in clinical practise was found. The importance of lowering the barriers for participation in national proton trials and proton treatment were emphasized, however, there is a lack of knowledge about individual and organizational barriers to accepting PBT, and further research is therefore needed. CONCLUSION: Collaboration between the Nordic countries regarding patients' perspectives in the context of PBT is of importance to compare national differences as well as to find similarities, but most importantly to learn from each other and to improve patient care. Nordic collaboration with focus on systematic collection of patient-reported outcomes in the context of PBT is unique. Collaboration in research offers the possibility to increase the inclusion of patients' perspectives in study protocols.


Asunto(s)
Neoplasias/radioterapia , Terapia de Protones , Congresos como Asunto , Dinamarca , Humanos , Noruega , Medición de Resultados Informados por el Paciente , Suecia
2.
BMC Med Imaging ; 14: 4, 2014 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-24460666

RESUMEN

BACKGROUND: Delineation of the target volume is a time-consuming task in radiotherapy treatment planning, yet essential for a successful treatment of cancers such as prostate cancer. To facilitate the delineation procedure, the paper proposes an intuitive approach for 3D modeling of the prostate by slice-wise best fitting ellipses. METHODS: The proposed estimate is initialized by the definition of a few control points in a new patient. The method is not restricted to particular image modalities but assumes a smooth shape with elliptic cross sections of the object. A training data set of 23 patients was used to calculate a prior shape model. The mean shape model was evaluated based on the manual contour of 10 test patients. The patient records of training and test data are based on axial T1-weighted 3D fast-field echo (FFE) sequences. The manual contours were considered as the reference model. Volume overlap (Vo), accuracy (Ac) (both ratio, range 0-1, optimal value 1) and Hausdorff distance (HD) (mm, optimal value 0) were calculated as evaluation parameters. RESULTS: The median and median absolute deviation (MAD) between manual delineation and deformed mean best fitting ellipses (MBFE) was Vo (0.9 ± 0.02), Ac (0.81 ± 0.03) and HD (4.05 ± 1.3)mm and between manual delineation and best fitting ellipses (BFE) was Vo (0.96 ± 0.01), Ac (0.92 ± 0.01) and HD (1.6 ± 0.27)mm. Additional results show a moderate improvement of the MBFE results after Monte Carlo Markov Chain (MCMC) method. CONCLUSIONS: The results emphasize the potential of the proposed method of modeling the prostate by best fitting ellipses. It shows the robustness and reproducibility of the model. A small sample test on 8 patients suggest possible time saving using the model.


Asunto(s)
Próstata/anatomía & histología , Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Simulación por Computador , Humanos , Imagenología Tridimensional/métodos , Masculino , Método de Montecarlo , Radiografía , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA