Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Phys Rev Lett ; 105(14): 145003, 2010 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-21230839

RESUMEN

Reversed-shear Alfvén eigenmodes were observed for the first time in a helical plasma having negative q0'' (the curvature of the safety factor q at the zero shear layer). The frequency is swept downward and upward sequentially via the time variation in the maximum of q. The eigenmodes calculated by ideal MHD theory are consistent with the experimental data. The frequency sweeping is mainly determined by the effects of energetic ions and the bulk pressure gradient. Coupling of reversed-shear Alfvén eigenmodes with energetic ion driven geodesic acoustic modes generates a multitude of frequency-sweeping modes.

2.
Rev Sci Instrum ; 79(2 Pt 2): 02A518, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18315139

RESUMEN

To investigate a Cs behavior, optical diagnostic tools have been installed in the large negative ion source, an arc discharge used at large helical device neutral beam injector. A large Cs sputtering is observed during beam extraction due to the backstreaming H(+) ions. Distribution of Cs(+) light is uniform in the case of a balanced arc discharge, but large increase of Cs(+) light during beam extraction is observed in a nonuniform arc discharge. Controlling of the discharge uniformity is effective to reduce the local heat loading from the backstreaming H(+) ions at the backplate of ion source.

3.
Rev Sci Instrum ; 79(2 Pt 2): 02C107, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18315233

RESUMEN

The beam profiles, port-through, rates and injection powers obtained with an improved accelerator with the multislot grounded grid are described. The accelerator has a combination of a steering grid with racetrack shaped aperture and multislot grounded grid to improve the beam optics. The optimal beam optics is obtained at the voltage ratio of 16.5-16.8, and the profiles are well fit by superposing multibeamlets with the divergent angles of 5.0 and 7.2 mrad along the direction parallel to the long and short axes of the slots of grounded grid. By adopting the racetrack shaped steering grid, the port-through rate increases from 34% to 38%, and the maximum injection power reaches 6 MW/187 keV.

4.
Rev Sci Instrum ; 79(2 Pt 2): 02C105, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18315231

RESUMEN

In the large area negative ion source for the LHD negative-ion-(H(-))-based neutral beam system, (I) we used the spectrometer to measure caesium lines in the source plasma during beam shots. (II) With Doppler-shifted measurements, the H(alpha) line at three different locations along the beam as well as the spectrum profile for cases of different plasma grid areas. (III) Caesium deposition monitor with a high speed shutter was tested to measure the weight of the deposited Cs layer. In the observation, cleaner spectra of Doppler-shifted H(alpha) line with only a small level of background light were obtained at a new observation port which viewed the blueshifted light in the drift region after the accelerator of a LHD ion source. Both the amounts of Cs I (852 nm, neutral Cs(0)) and Cs II (522 nm, Cs(+)) in the source plasma light rose sharply when beam acceleration began, and continued rising during a 10 s pulse. It was thought that this was because the cesium was evaporated/sputtered from the source back plate by the back-streaming positive ions. Cs deposition rate to the crystal sensor measured by adjusting the shutter open time was evaluated to be 2.9 nanograms/s cm(2) for preliminary testing. More neutral Cs tended to be evolved in the source after arc discharge. Much Cs could be consumed in a high rate-pulsed operation (such as LHD source).

5.
Rev Sci Instrum ; 87(2): 02B103, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26931985

RESUMEN

Experiments by a four-pin probe and photodetachment technique were carried out to investigate the charged particle flows in the beam extraction region of a negative hydrogen ion source for neutral beam injector. Electron and positive ion flows were obtained from the polar distribution of the probe saturation current. Negative hydrogen ion flow velocity and temperature were obtained by comparing the recovery times of the photodetachment signals at opposite probe tips. Electron and positive ions flows are dominated by crossed field drift and ambipolar diffusion. Negative hydrogen ion temperature is evaluated to be 0.12 eV.

6.
Rev Sci Instrum ; 87(2): 02B113, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26931995

RESUMEN

A spectrally selective imaging system has been installed in the RF negative ion source in the International Thermonuclear Experimental Reactor-relevant negative ion beam test facility ELISE (Extraction from a Large Ion Source Experiment) to investigate distribution of hydrogen Balmer-α emission (Hα) close to the production surface of hydrogen negative ion. We selected a GigE vision camera coupled with an optical band-path filter, which can be controlled remotely using high speed network connection. A distribution of Hα emission near the bias plate has been clearly observed. The same time trend on Hα intensities measured by the imaging diagnostic and the optical emission spectroscopy is confirmed.

7.
Rev Sci Instrum ; 87(2): 02B321, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26932049

RESUMEN

To improve the performance of negative-ion based neutral beam injection on the Large Helical Device, the accelerator was modified on the basis of numerical investigations. A field limiting ring was installed on the upper side of a grounded grid (GG) support and a multi-slot GG was adopted instead of a multi-aperture GG. As a result, the voltage holding capability is improved and the heat load on the GG decreases by 40%. In addition, the arc efficiency is improved significantly only by replacing the GG.

8.
Rev Sci Instrum ; 87(2): 02B908, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26932080

RESUMEN

At National Institute for Fusion Science (NIFS), a multi-ampere negative ion source is used to support the R&D on H(-) production, extraction, and acceleration. In this contribution, we study the characteristics of the acceleration system of this source, in order to characterize the beam optics at different operational conditions. A dedicated experimental campaign was carried out at NIFS, using as main diagnostic the infra-red imaging of the beam profiles. The experimental measurements are also compared with 3D numerical simulations, in order to validate the codes and to assess their degree of reliability. The simulations show a satisfactory agreement with the experimental results.

9.
Rev Sci Instrum ; 87(11): 11E105, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910614

RESUMEN

The upgraded millimeter-wave interferometer with the frequency of 70 GHz is installed on a large-scaled negative ion source. Measurable line-averaged electron density is from 2 × 1015 to 3 × 1018 m-3 in front of the plasma grid. Several improvements such as the change to shorter wavelength probing with low noise, the installation of special ordered horn antenna, the signal modulation for a high accuracy digital phase detection, the insertion of insulator, and so on, are carried out for the measurement during the beam extraction by applying high voltage. The line-averaged electron density is successfully measured and it is found that it increases linearly with the arc power and drops suddenly at the beam extraction.

10.
Rev Sci Instrum ; 87(2): 02B936, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26932108

RESUMEN

Recent research results on negative-ion-rich plasmas in a large negative ion source have been reviewed. Spatial density and flow distributions of negative hydrogen ions (H(-)) and positive hydrogen ions together with those of electrons are investigated with a 4-pin probe and a photodetachment (PD) signal of a Langmuir probe. The PD signal is converted to local H(-) density from signal calibration to a scanning cavity ring down PD measurement. Introduction of Cs changes the slope of plasma potential local distribution depending upon the plasma grid bias. A higher electron density H2 plasma locally shields the bias potential and behaves like a metallic free electron gas. On the other hand, the bias and extraction electric fields penetrate in a Cs-seeded electronegative plasma even when the electron density is similar. Electrons are transported by the penetrated electric fields from the driver region along and across the filter and electron deflection magnetic fields. Plasma ions exhibited a completely different response against the penetration of electric fields.

11.
Rev Sci Instrum ; 85(2): 02A724, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24593458

RESUMEN

A spectrally selective imaging system has been developed to obtain a distribution of Hα emissions at the extraction region in a hydrogen negative ion source. The diagnostic system consisted of an aspherical lens, optical filters, a fiber image conduit, and a charge coupled device detector was installed on the 1/3-scaled hydrogen negative ion source in the National Institute for Fusion Science. The center of sight line passes beside the plasma grid (PG) surface with the distance of 11 mm, and the viewing angle has coverage 35 mm from the PG surface. Two dimensional Hα distribution in the range up to 20 mm from the PG surface was clearly observed. The reduction area for Hα emission caused by beam extraction was widely distributed in the extraction region near the PG surface.

12.
Rev Sci Instrum ; 85(2): 02B131, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24593571

RESUMEN

The electron density was measured at various bias voltages to understand how the plasma grid bias affects the electron near the plasma grid in large-scaled negative ion sources. It was found that the response of the electron to the bias voltage changes depending on negative ion production processes. The electron density remarkably decreases with increasing the bias voltage in the pure-volume plasma. On the other hand, the electron density depends on the bias voltage weakly in the Cs-seeded plasma. In addition, it was observed that the response of the co-extracted electron current to the bias voltage has similar trend to that of the electron density.

13.
Rev Sci Instrum ; 85(11): 11E110, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430289

RESUMEN

The neutron profile monitor stably operated at a high-count-rate for deuterium operations in the Large Helical Device has been developed to enhance the research on the fast-ion confinement. It is composed of a multichannel collimator, scintillation-detectors, and a field programmable gate array circuit. The entire neutron detector system was tested using an accelerator-based neutron generator. This system stably acquires the pulse data without any data loss at high-count-rate conditions up to 8 × 10(5) counts per second.

14.
Rev Sci Instrum ; 85(11): 11E114, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430293

RESUMEN

A fast time response, wide dynamic range neutron flux monitor has been developed toward the LHD deuterium operation by using leading-edge signal processing technologies providing maximum counting rate up to ∼5 × 10(9) counts/s. Because a maximum total neutron emission rate over 1 × 10(16) n/s is predicted in neutral beam-heated LHD plasmas, fast response and wide dynamic range capabilities of the system are essential. Preliminary tests have demonstrated successful performance as a wide dynamic range monitor along the design.

15.
Rev Sci Instrum ; 83(2): 02B122, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22380279

RESUMEN

H(-) beam was successfully extracted from a cesium seeded ion source operated using a field effect transistor inverter power supply as a radio frequency (RF) wave source. High density hydrogen plasma more than 10(19) m(-3) was obtained using an external type antenna with RF frequency of lower than 0.5 MHz. The source was isolated by an isolation transformer and H(-) ion beam was extracted from a single aperture. Acceleration current and extraction current increased with the increase of extraction voltage. Addition of a small amount of cesium vapor into the source enhanced the currents.

16.
Rev Sci Instrum ; 83(2): 02A731, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22380240

RESUMEN

Hydrogen negative ion density measurements are required to clarify the characteristics of negative ion production and ion source performance. Both of laser photodetachment and cavity ring down (CRD) measurements have been implemented to a field-effect-transistor based radio-frequency ion source. The density ratio of negative hydrogen ions to electrons was successfully measured by laser photodetachment and effect of magnetic filter field on negative ion density was confirmed. The calculated CRD signal showed that CRD mirrors with >99.990% reflectivity are required and loss of reflectivity due to cesium contamination should be minimized.

17.
Rev Sci Instrum ; 83(2): 02B113, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22380270

RESUMEN

Electron density measurements of a large-scaled negative ion source were carried out with a surface wave probe. By comparison of the electron densities determined with the surface wave probe and a Langmuir probe, it was confirmed that the surface wave probe is highly available for diagnostic of the electron density in H(-) ion sources. In addition, it was found that the ratio of the electron density to the H(-) ion density dramatically decreases with increase of a bias voltage and the H(-) ions become dominant negative particles at the bias voltage of more than 6 V.

18.
Rev Sci Instrum ; 83(2): 02B116, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22380273

RESUMEN

We report on the characteristics of the electronegative plasma in a large-scale hydrogen negative ion (H(-)) source. The measurement has been made with a time-resolved Langmuir probe installed in the beam extraction region. The H(-) density is monitored with a cavity ring-down system to identify the electrons in the negative charges. The electron-saturation current decreases rapidly after starting to seed Cs, and ion-ion plasma is observed in the extraction region. The H(-) density steps down during the beam extraction and the electron density jumps up correspondingly. The time integral of the decreasing H(-) charge density agrees well with the electron charge collected with the probe. The agreement of the charges is interpreted to indicate that the H(-) density decreasing at the beam extraction is compensated by the electrons diffusing from the driver region. In the plasmas with very low electron density, the pre-sheath of the extraction field penetrates deeply inside the plasmas. That is because the shielding length in those plasmas is longer than that in the usual electron-ion plasmas, and furthermore the electrons are suppressed to diffuse to the extraction region due to the strong magnetic field.

19.
Rev Sci Instrum ; 81(2): 02B107, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20192414

RESUMEN

Characteristics of radio frequency (RF) plasma production are investigated using a field effect transistor inverter power supply as an RF wave source. With the frequency of around 0.3 MHz, an electron density over 10(18) m(-3) is produced in argon plasma. Although lower densities are obtained in hydrogen plasma, it drastically increased up to 5x10(18) m(-3) with an axial magnetic field of around 100 G applied in the driver region. Effects of the magnetic field and gas pressure are investigated in the RF produced plasma with the frequency of several hundred kilohertz.

20.
Rev Sci Instrum ; 81(10): 10D327, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033849

RESUMEN

A tangential Fast Ion Charge eXchange Spectroscopy is newly applied on a Large Helical Device (LHD) for co/countercirculating fast ions, which are produced by high energy tangential negative-ion based neutral beam injection. With this new observation geometry, both the tangential-neutral beam (NB) and a low-energy radial-NB based on positive ions can be utilized as probe beams of the measurement. We have successfully observed Doppler-shifted H-alpha lights due to the charge exchange process between the probing NB and circulating hydrogen ions of around 100 keV in LHD plasmas.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA