Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Mikrochim Acta ; 189(2): 72, 2022 01 24.
Artículo en Inglés | MEDLINE | ID: mdl-35075569

RESUMEN

Nitrogen-doped carbon dots/Ni-MnFe-layered double hydroxides (N-CDs/Ni-MnFe-LDHs) are demonstrated as superior peroxidase mimic antibody labels alternative to horseradish peroxidase (HRP) in an immunoassay, potentially overcoming some of the inherent disadvantages of HRP and other enzyme mimicking nanomaterials. They revealed efficient peroxidase-like activity and catalyzed the oxidation of colorless 3,3',5,5'-tetramethylbenzidine (TMB) to form the intense blue product (at 620 nm) in the presence of hydrogen peroxide (H2O2). Using low-density lipoprotein (LDL) as a model target, an ultra-low limit of detection (0.0051 mg/dL) and a linear range of 0.0625-0.750 mg/dL were achieved, exhibiting higher sensitivity than the HRP-based immunoassay. Thus, the proposed N-CDs/Ni-MnFe-LDHs can be used as HRP mimicking analogs for developing highly sensitive colorimetric immunosensors for detection of biomarkers, as well as trace chemical analysis.


Asunto(s)
Compuestos Férricos/química , Lipoproteínas LDL/química , Compuestos de Manganeso/química , Nanoestructuras/química , Níquel/química , Nitrógeno/química , Puntos Cuánticos/química , Carbono , Inmunoensayo/métodos
2.
Anal Sci ; 34(1): 75-81, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29321463

RESUMEN

A smartphone application, called CAnal, was developed as a colorimetric analyzer in paper-based devices for sensitive and selective determination of mercury(II) in water samples. Measurement on the double layer of a microfluidic paper-based analytical device (µPAD) fabricated by alkyl ketene dimer (AKD)-inkjet printing technique with special design doped with unmodified silver nanoparticles (AgNPs) onto the detection zones was performed by monitoring the gray intensity in the blue channel of AgNPs, which disintegrated when exposed to mercury(II) on µPAD. Under the optimized conditions, the developed approach showed high sensitivity, low limit of detection (0.003 mg L-1, 3SD blank/slope of the calibration curve), small sample volume uptake (two times of 2 µL), and short analysis time. The linearity range of this technique ranged from 0.01 to 10 mg L-1 (r2 = 0.993). Furthermore, practical analysis of various water samples was also demonstrated to have acceptable performance that was in agreement with the data from cold vapor atomic absorption spectrophotometry (CV-AAS), a conventional method. The proposed technique allows for a rapid, simple (instant report of the final mercury(II) concentration in water samples via smartphone display), sensitive, selective, and on-site analysis with high sample throughput (48 samples h-1, n = 3) of trace mercury(II) in water samples, which is suitable for end users who are unskilled in analyzing mercury(II) in water samples.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA