Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 263
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Hepatology ; 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38489521

RESUMEN

BACKGROUND AND AIMS: Transient elastography (TE), shear-wave elastography (SWE), and/or magnetic resonance elastography (MRE), each providing liver stiffness measurement (LSM), are the most studied imaging-based noninvasive liver disease assessment (NILDA) techniques. To support the American Association for the Study of Liver Diseases guidelines on NILDA, we summarized the evidence on the accuracy of these LSM methods to stage liver fibrosis (F). APPROACH AND RESULTS: A comprehensive search for studies assessing LSM by TE, SWE, or MRE for the identification of significant fibrosis (F2-4), advanced fibrosis (F3-4), or cirrhosis (F4), utilizing histopathology as standard of reference by liver disease etiology in adults or children from inception to April 2022 was performed. We excluded studies with <50 patients with a single disease entity and mixed liver disease etiologies (with the exception of HCV/HIV co-infection). Out of 9447 studies, 240 with 61,193 patients were included in this systematic review. In adults, sensitivities for the identification of F2-4 ranged from 51% to 95%, for F3-4 from 70% to 100%, and for F4 from 60% to 100% across all techniques/diseases, whereas specificities ranged from 36% to 100%, 74% to 100%, and 67% to 99%, respectively. The largest body of evidence available was for TE; MRE appeared to be the most accurate method. Imaging-based NILDA outperformed blood-based NILDA in most comparisons, particularly for the identification of F3-4/F4. In the pediatric population, imaging-based NILDA is likely as accurate as in adults. CONCLUSION: LSM from TE, SWE, and MRE show acceptable to outstanding accuracy for the detection of liver fibrosis across various liver disease etiologies. Accuracy increased from F2-4 to F3-4 and was the highest for F4. Further research is needed to better standardize the use of imaging-based NILDA, particularly in pediatric liver diseases.

2.
J Proteome Res ; 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38980715

RESUMEN

Hepatocellular carcinoma (HCC) mortality rates continue to increase faster than those of other cancer types due to high heterogeneity, which limits diagnosis and treatment. Pathological and molecular subtyping have identified that HCC tumors with poor outcomes are characterized by intratumoral collagenous accumulation. However, the translational and post-translational regulation of tumor collagen, which is critical to the outcome, remains largely unknown. Here, we investigate the spatial extracellular proteome to understand the differences associated with HCC tumors defined by Hoshida transcriptomic subtypes of poor outcome (Subtype 1; S1; n = 12) and better outcome (Subtype 3; S3; n = 24) that show differential stroma-regulated pathways. Collagen-targeted mass spectrometry imaging (MSI) with the same-tissue reference libraries, built from untargeted and targeted LC-MS/MS was used to spatially define the extracellular microenvironment from clinically-characterized, formalin-fixed, paraffin-embedded tissue sections. Collagen α-1(I) chain domains for discoidin-domain receptor and integrin binding showed distinctive spatial distribution within the tumor microenvironment. Hydroxylated proline (HYP)-containing peptides from the triple helical regions of fibrillar collagens distinguished S1 from S3 tumors. Exploratory machine learning on multiple peptides extracted from the tumor regions could distinguish S1 and S3 tumors (with an area under the receiver operating curve of ≥0.98; 95% confidence intervals between 0.976 and 1.00; and accuracies above 94%). An overall finding was that the extracellular microenvironment has a high potential to predict clinically relevant outcomes in HCC.

3.
Radiology ; 311(2): e233136, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38742971

RESUMEN

Background MR elastography (MRE) has been shown to have excellent performance for noninvasive liver fibrosis staging. However, there is limited knowledge regarding the precision and test-retest repeatability of stiffness measurement with MRE in the multicenter setting. Purpose To determine the precision and test-retest repeatability of stiffness measurement with MRE across multiple centers using the same phantoms. Materials and Methods In this study, three cylindrical phantoms made of polyvinyl chloride gel mimicking different degrees of liver stiffness in humans (phantoms 1-3: soft, medium, and hard stiffness, respectively) were evaluated. Between January 2021 and January 2022, phantoms were circulated between five different centers and scanned with 10 MRE-equipped clinical 1.5-T and 3-T systems from three major vendors, using two-dimensional (2D) gradient-recalled echo (GRE) imaging and/or 2D spin-echo (SE) echo-planar imaging (EPI). Similar MRE acquisition parameters, hardware, and reconstruction algorithms were used at each center. Mean stiffness was measured by a single observer for each phantom and acquisition on a single section. Stiffness measurement precision and same-session test-retest repeatability were assessed using the coefficient of variation (CV) and the repeatability coefficient (RC), respectively. Results The mean precision represented by the CV was 5.8% (95% CI: 3.8, 7.7) for all phantoms and both sequences combined. For all phantoms, 2D GRE achieved a CV of 4.5% (95% CI: 3.3, 5.7) whereas 2D SE EPI achieved a CV of 7.8% (95% CI: 3.1, 12.6). The mean RC of stiffness measurement was 5.8% (95% CI: 3.7, 7.8) for all phantoms and both sequences combined, 4.9% (95% CI: 2.7, 7.0) for 2D GRE, and 7.0% (95% CI: 2.9, 11.2) for 2D SE EPI (all phantoms). Conclusion MRE had excellent in vitro precision and same-session test-retest repeatability in the multicenter setting when similar imaging protocols, hardware, and reconstruction algorithms were used. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Tang in this issue.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Fantasmas de Imagen , Diagnóstico por Imagen de Elasticidad/métodos , Diagnóstico por Imagen de Elasticidad/instrumentación , Reproducibilidad de los Resultados , Humanos , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Cirrosis Hepática/diagnóstico por imagen
4.
J Magn Reson Imaging ; 2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38226697

RESUMEN

Gadolinium-based contrast agents (GBCAs) are routinely used in magnetic resonance imaging (MRI). They are essential for choosing the most appropriate medical or surgical strategy for patients with serious pathologies, particularly in oncologic, inflammatory, and cardiovascular diseases. However, GBCAs have been associated with an increased risk of nephrogenic systemic fibrosis in patients with renal failure, as well as the possibility of deposition in the brain, bones, and other organs, even in patients with normal renal function. Research is underway to reduce the quantity of gadolinium injected, without compromising image quality and diagnosis. The next generation of GBCAs will enable a reduction in the gadolinium dose administered. Gadopiclenol is the first of this new generation of GBCAs, with high relaxivity, thus having the potential to reduce the gadolinium dose while maintaining good in vivo stability due to its macrocyclic structure. High-stability and high-relaxivity GBCAs will be one of the solutions for reducing the dose of gadolinium to be administered in clinical practice, while the development of new technologies, including optimization of MRI acquisitions, new contrast mechanisms, and artificial intelligence may help reduce the need for GBCAs. Future solutions may involve a combination of next-generation GBCAs and image-processing techniques to optimize diagnosis and treatment planning while minimizing exposure to gadolinium. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 3.

5.
J Magn Reson Imaging ; 59(1): 58-69, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37144673

RESUMEN

Abbreviated MRI (AMRI) protocols rely on the acquisition of a limited number of sequences tailored to a specific question. The main objective of AMRI protocols is to reduce exam duration and costs, while maintaining an acceptable diagnostic performance. AMRI is of increasing interest in the radiology community; however, challenges limiting clinical adoption remain. In this review, we will address main abdominal and pelvic applications of AMRI in the liver, pancreas, kidney, and prostate, including diagnostic performance, pitfalls, limitations, and cost effectiveness will also be discussed. Level of Evidence: 3 Technical Efficacy Stage: 3.


Asunto(s)
Neoplasias Hepáticas , Imagen por Resonancia Magnética , Masculino , Humanos , Imagen por Resonancia Magnética/métodos , Abdomen/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico , Pelvis/diagnóstico por imagen
6.
Eur Radiol ; 34(1): 475-484, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37540318

RESUMEN

OBJECTIVES: Radiation segmentectomy using yttrium-90 plays an emerging role in the management of early-stage HCC. However, the value of early post-treatment MRI for response assessment is uncertain. We assessed the value of response criteria obtained early after radiation segmentectomy in predicting long-term response in patients with HCC. MATERIALS AND METHODS: Patients with HCC who underwent contrast-enhanced MRI before, early, and 12 months after radiation segmentectomy were included in this retrospective single-center study. Three independent radiologists reviewed images at baseline and 1st follow-up after radiation segmentectomy and assessed lesion-based response according to mRECIST, LI-RADS treatment response algorithm (TRA), and image subtraction. The endpoint was response at 12 months based on consensus readout of two separate radiologists. Diagnostic accuracy for predicting complete response (CR) at 12 months based on the 1st post-treatment MRI was calculated. RESULTS: Eighty patients (M/F 60/20, mean age 67.7 years) with 80 HCCs were assessed (median size baseline, 1.8 cm [IQR, 1.4-2.9 cm]). At 12 months, 74 patients were classified as CR (92.5%), 5 as partial response (6.3%), and 1 as progressive disease (1.2%). Diagnostic accuracy for predicting CR was fair to good for all readers with excellent positive predictive value (PPV): mRECIST (range between 3 readers, accuracy: 0.763-0.825, PPV: 0.966-1), LI-RADS TRA (accuracy: 0.700-0.825, PPV: 0.983-1), and subtraction (accuracy: 0.775-0.825, PPV: 0.967-1), with no difference in accuracy between criteria (p range 0.053 to > 0.9). CONCLUSION: mRECIST, LI-RADS TRA, and subtraction obtained on early post-treatment MRI show similar performance for predicting long-term response in patients with HCC treated with radiation segmentectomy. CLINICAL RELEVANCE STATEMENT: Response assessment extracted from early post-treatment MRI after radiation segmentectomy predicts complete response in patients with HCC with high PPV (≥ 0.96). KEY POINTS: • Early post-treatment response assessment on MRI predicts response in patients with HCC treated with radiation segmentectomy with fair to good accuracy and excellent positive predictive value. • There was no difference in diagnostic accuracy between mRECIST, LI-RADS, and subtraction for predicting HCC response to radiation segmentectomy.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Anciano , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/cirugía , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/cirugía , Estudios Retrospectivos , Neumonectomía , Imagen por Resonancia Magnética/métodos , Sensibilidad y Especificidad , Medios de Contraste
7.
Radiographics ; 44(1): e230131, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38127661

RESUMEN

Ulcerative colitis (UC) is a chronic idiopathic inflammatory bowel disease (IBD) that progressively affects mucosa and submuccosa of the colon and rectum in a continual pattern. In comparison, Crohn disease (CD), the other type of IBD, is a chronic transmural inflammatory disorder that can involve any part of the gastrointestinal tract. MR enterography (MRE) has emerged as an important imaging modality for the diagnosis and detection of disease activity and complications in CD, with comparable results to those of endoscopy. But MRE has been underused for assessment of UC in recent years, and clinicians heavily rely on endoscopic findings for management of UC. Despite UC being considered an endoscopically assessable disease, MRE can provide useful information beyond that obtained with endoscopy about mural or extramural abnormalities, inaccessible parts of the colonic lumen, associated extraintestinal diseases, and superimposed pathologic conditions. Moreover, endoscopy might be contraindicated in some clinical settings due to the risk of colonic perforation. In addition to depicting the features of UC activity in different phases, MRE demonstrates findings of disease chronicity that cannot be achieved with endoscopy, particularly in a patient with colitis of unknown cause. The valuable diagnostic role of MRE to exclude undiagnosed CD in patients with UC who have refractory disease or those with postproctocolectomy complications is also emphasized. Radiologists can play a crucial role in the management of UC with MRE by addressing what is beyond endoscopy. ©RSNA, 2023 Test Your Knowledge questions are available in the supplemental material.


Asunto(s)
Colitis Ulcerosa , Enfermedad de Crohn , Enfermedades Inflamatorias del Intestino , Humanos , Colitis Ulcerosa/diagnóstico por imagen , Enfermedad de Crohn/diagnóstico por imagen , Endoscopía Gastrointestinal , Recto
8.
J Magn Reson Imaging ; 58(2): 342-359, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37052601

RESUMEN

Solid renal masses (SRMs) are increasingly detected and encompass both benign and malignant masses, with renal cell carcinoma (RCC) being the most common malignant SRM. Most patients with SRMs will undergo management without a priori pathologic confirmation. There is an unmet need to noninvasively diagnose and characterize RCCs, as significant variability in clinical behavior is observed and a wide range of differing management options exist. Cross-sectional imaging modalities, including magnetic resonance imaging (MRI), are increasingly used for SRM characterization. Multiparametric (mp) MRI techniques can provide insight into tumor biology by probing different physiologic/pathophysiologic processes noninvasively. These include sequences that probe tissue microstructure, including intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) and T1 relaxometry; oxygen metabolism (blood oxygen level dependent [BOLD-MRI]); as well as vascular flow and perfusion (dynamic contrast-enhanced MRI [DCE-MRI] and arterial spin labeling [ASL]). In this review, we will discuss each mpMRI method in terms of its principles, roles, and discuss the results of human studies for SRM assessment. Future validation of these methods may help to enable a personalized management approach for patients with SRM in the emerging era of precision medicine. EVIDENCE LEVEL: 5. TECHNICAL EFFICACY: 2.


Asunto(s)
Carcinoma de Células Renales , Neoplasias Renales , Imágenes de Resonancia Magnética Multiparamétrica , Humanos , Medios de Contraste , Imagen por Resonancia Magnética/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Carcinoma de Células Renales/diagnóstico por imagen , Neoplasias Renales/diagnóstico por imagen , Movimiento (Física)
9.
Eur Radiol ; 33(10): 6929-6938, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37464111

RESUMEN

OBJECTIVES: This study aimed to compare two abbreviated MRI (AMRI) protocols to complete MRI for HCC detection: non-contrast (NC)-AMRI without/with alpha foetoprotein (AFP) and dynamic contrast-enhanced (Dyn)-AMRI. METHODS: This retrospective single-center study included 351 patients (M/F: 264/87, mean age: 57y) with chronic liver disease, who underwent MRI for HCC surveillance between 2014 and 2020. Two reconstructed AMRI sets were obtained based on complete MRI: NC-AMRI (T2-weighted imaging (WI) + diffusion-WI) and Dyn-AMRI (T2-WI + dynamic T1-WI) and were assessed by 2 radiologists who reported all suspicious lesions, using LI-RADS/adapted LI-RADS classification. The reference standard was based on all available patient data. Inter-reader agreement was assessed and MRI diagnostic performance was compared to the reference standard. RESULTS: The reference standard demonstrated 83/351 HCC-positive patients (prevalence: 23.6%, median size: 22 mm, and positive MRIs: 83/631). Inter-reader agreement was substantial for all sets. Sensitivities of Dyn-AMRI and complete MRI (both 92.8%) were similar, higher than NC-AMRI (72.3%, p < 0.001). Specificities were not different between sets. NC-AMRI + AFP (92.8%) had similar sensitivity to Dyn-AMRI and complete MRI. In patients with small size HCCs (≤ 2 cm), sensitivities of Dyn-AMRI (85.3%) and complete MRI (88.2%) remained similar (p = 0.564), also outperforming NC-AMRI (52.9%, p < 0.05). NC-AMRI + AFP had similar sensitivity (88.2%) to Dyn-AMRI and complete MRI (p = 0.706 and p = 1, respectively). CONCLUSIONS: Dyn-AMRI has similar diagnostic performance to complete MRI for HCC detection, while both outperform NC-AMRI, especially for small size HCCs. NC-AMRI + AFP demonstrates similar sensitivity to Dyn-AMRI and complete MRI. CLINICAL RELEVANCE STATEMENT: Due to the low sensitivity of ultrasound for hepatocellular screening, new screening methods are needed. Abbreviated MRI (AMRI) is a candidate, especially non-contrast AMRI with serum alpha foetoprotein as the acquisition time is low, without the need for contrast medium injection. KEY POINTS: • Dynamic contrast-enhanced abbreviated MRI using extracellular gadolinium-based contrast agent and complete MRI have similar diagnostic performance for hepatocellular carcinoma detection in an at-risk population. • Non-contrast abbreviated MRI with alpha foetoprotein has similar diagnostic performance to dynamic contrast-enhanced abbreviated MRI and complete MRI, including when considering small size hepatocellular carcinoma ≤ 2 cm. • Non-contrast abbreviated MRI and dynamic contrast-enhanced abbreviated MRI can be performed in 7 and 10 min, excluding patient setup time.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Persona de Mediana Edad , Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Estudios Retrospectivos , alfa-Fetoproteínas , Gadolinio DTPA , Imagen por Resonancia Magnética/métodos , Medios de Contraste/farmacología , Sensibilidad y Especificidad
10.
Eur Radiol ; 33(9): 6020-6032, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37071167

RESUMEN

OBJECTIVE: To assess the performance of convolutional neural networks (CNNs) for semiautomated segmentation of hepatocellular carcinoma (HCC) tumors on MRI. METHODS: This retrospective single-center study included 292 patients (237 M/55F, mean age 61 years) with pathologically confirmed HCC between 08/2015 and 06/2019 and who underwent MRI before surgery. The dataset was randomly divided into training (n = 195), validation (n = 66), and test sets (n = 31). Volumes of interest (VOIs) were manually placed on index lesions by 3 independent radiologists on different sequences (T2-weighted imaging [WI], T1WI pre-and post-contrast on arterial [AP], portal venous [PVP], delayed [DP, 3 min post-contrast] and hepatobiliary phases [HBP, when using gadoxetate], and diffusion-weighted imaging [DWI]). Manual segmentation was used as ground truth to train and validate a CNN-based pipeline. For semiautomated segmentation of tumors, we selected a random pixel inside the VOI, and the CNN provided two outputs: single slice and volumetric outputs. Segmentation performance and inter-observer agreement were analyzed using the 3D Dice similarity coefficient (DSC). RESULTS: A total of 261 HCCs were segmented on the training/validation sets, and 31 on the test set. The median lesion size was 3.0 cm (IQR 2.0-5.2 cm). Mean DSC (test set) varied depending on the MRI sequence with a range between 0.442 (ADC) and 0.778 (high b-value DWI) for single-slice segmentation; and between 0.305 (ADC) and 0.667 (T1WI pre) for volumetric-segmentation. Comparison between the two models showed better performance in single-slice segmentation, with statistical significance on T2WI, T1WI-PVP, DWI, and ADC. Inter-observer reproducibility of segmentation analysis showed a mean DSC of 0.71 in lesions between 1 and 2 cm, 0.85 in lesions between 2 and 5 cm, and 0.82 in lesions > 5 cm. CONCLUSION: CNN models have fair to good performance for semiautomated HCC segmentation, depending on the sequence and tumor size, with better performance for the single-slice approach. Refinement of volumetric approaches is needed in future studies. KEY POINTS: • Semiautomated single-slice and volumetric segmentation using convolutional neural networks (CNNs) models provided fair to good performance for hepatocellular carcinoma segmentation on MRI. • CNN models' performance for HCC segmentation accuracy depends on the MRI sequence and tumor size, with the best results on diffusion-weighted imaging and T1-weighted imaging pre-contrast, and for larger lesions.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Persona de Mediana Edad , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Estudios Retrospectivos , Reproducibilidad de los Resultados , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Redes Neurales de la Computación
11.
Eur Radiol ; 33(12): 9152-9166, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37500964

RESUMEN

The 10th Global Forum for Liver Magnetic Resonance Imaging (MRI) was held as a virtual 2-day meeting in October 2021, attended by delegates from North and South America, Asia, Australia, and Europe. Most delegates were radiologists with experience in liver MRI, with representation also from specialists in liver surgery, oncology, and hepatology. Presentations, discussions, and working groups at the Forum focused on the following themes: • Gadoxetic acid in clinical practice: Eastern and Western perspectives on current uses and challenges in hepatocellular carcinoma (HCC) screening/surveillance, diagnosis, and management • Economics and outcomes of HCC imaging • Radiomics, artificial intelligence (AI) and deep learning (DL) applications of MRI in HCC. These themes are the subject of the current manuscript. A second manuscript discusses multidisciplinary tumor board perspectives: how to approach early-, mid-, and late-stage HCC management from the perspectives of a liver surgeon, interventional radiologist, and oncologist (Taouli et al, 2023). Delegates voted on consensus statements that were developed by working groups on these meeting themes. A consensus was considered to be reached if at least 80% of the voting delegates agreed on the statements. CLINICAL RELEVANCE STATEMENT: This review highlights the clinical applications of gadoxetic acid-enhanced MRI for liver cancer screening and diagnosis, as well as its cost-effectiveness and the applications of radiomics and AI in patients with liver cancer. KEY POINTS: • Interpretation of gadoxetic acid-enhanced MRI differs slightly between Eastern and Western guidelines, reflecting different regional requirements for sensitivity vs specificity. • Emerging data are encouraging for the cost-effectiveness of gadoxetic acid-enhanced MRI in HCC screening and diagnosis, but more studies are required. • Radiomics and artificial intelligence are likely, in the future, to contribute to the detection, staging, assessment of treatment response and prediction of prognosis of HCC-reducing the burden on radiologists and other specialists and supporting timely and targeted treatment for patients.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Inteligencia Artificial , Medios de Contraste , Gadolinio DTPA , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Sensibilidad y Especificidad , Estudios Retrospectivos
12.
Eur Radiol ; 33(12): 9167-9181, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37439935

RESUMEN

The 10th Global Forum for Liver Magnetic Resonance Imaging was held in October 2021. The themes of the presentations and discussions at this Forum are described in detail in the review by Taouli et al (2023). The focus of this second manuscript developed from the Forum is on multidisciplinary tumor board perspectives in hepatocellular carcinoma (HCC) management: how to approach early-, mid-, and late-stage management from the perspectives of a liver surgeon, an interventional radiologist, and an oncologist. The manuscript also includes a panel discussion by multidisciplinary experts on three selected cases that explore challenging aspects of HCC management. CLINICAL RELEVANCE STATEMENT: This review highlights the importance of a multidisciplinary team approach in liver cancer patients and includes the perspectives of a liver surgeon, an interventional radiologist, and an oncologist, including illustrative case studies. KEY POINTS: • A liver surgeon, interventional radiologist, and oncologist presented their perspectives on the treatment of early-, mid-, and late-stage HCC. • Different perspectives on HCC management between specialties emphasize the importance of multidisciplinary tumor boards. • A multidisciplinary faculty discussed challenging aspects of HCC management, as highlighted by three case studies.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/terapia , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Neoplasias Hepáticas/patología , Consenso , Medios de Contraste , Gadolinio DTPA , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética , Grupo de Atención al Paciente
13.
J Vasc Interv Radiol ; 34(10): 1794-1801.e2, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37364730

RESUMEN

PURPOSE: To assess the accuracy of a machine learning (ML) approach based on magnetic resonance (MR) imaging radiomic quantification obtained before treatment and early after treatment for prediction of early hepatocellular carcinoma (HCC) response to yttrium-90 transarterial radioembolization (TARE). MATERIALS AND METHODS: In this retrospective single-center study of 76 patients with HCC, baseline and early (1-2 months) post-TARE MR images were collected. Semiautomated tumor segmentation facilitated extraction of shape, first-order histogram, and custom signal intensity-based radiomic features, which were then trained (n = 46) using a ML XGBoost model and validated on a separate cohort (n = 30) not used in training to predict treatment response assessed at 4-6 months (based on modified Response and Evaluation Criteria in Solid Tumors criteria). Performance of this ML radiomic model was compared with those of models comprising clinical parameters and standard imaging characteristics using area under the receiver operating curve (AUROC) analysis for prediction of complete response (CR). RESULTS: Seventy-six tumors with a mean (±SD) diameter of 2.6 cm ± 1.6 were included. Sixty, 12, 1, and 3 patients were classified as having CR, partial response, stable disease, and progressive disease, respectively, at 4-6 months posttreatment on the basis of MR images. In the validation cohort, the radiomic model showed good performance (AUROC, 0.89) for prediction of CR, compared with models comprising clinical and standard imaging criteria (AUROC, 0.58 and 0.59, respectively). Baseline imaging features appeared to be more heavily weighted in the radiomic model. CONCLUSIONS: The use of ML modeling of radiomic data combining baseline and early follow-up MR imaging could predict HCC response to TARE. These models need to be investigated further in an independent cohort.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/patología , Estudios Retrospectivos , Neumonectomía , Imagen por Resonancia Magnética , Aprendizaje Automático
14.
Radiographics ; 43(6): e220181, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37227944

RESUMEN

Quantitative imaging biomarkers of liver disease measured by using MRI and US are emerging as important clinical tools in the management of patients with chronic liver disease (CLD). Because of their high accuracy and noninvasive nature, in many cases, these techniques have replaced liver biopsy for the diagnosis, quantitative staging, and treatment monitoring of patients with CLD. The most commonly evaluated imaging biomarkers are surrogates for liver fibrosis, fat, and iron. MR elastography is now routinely performed to evaluate for liver fibrosis and typically combined with MRI-based liver fat and iron quantification to exclude or grade hepatic steatosis and iron overload, respectively. US elastography is also widely performed to evaluate for liver fibrosis and has the advantage of lower equipment cost and greater availability compared with those of MRI. Emerging US fat quantification methods can be performed along with US elastography. The author group, consisting of members of the Society of Abdominal Radiology (SAR) Liver Fibrosis Disease-Focused Panel (DFP), the SAR Hepatic Iron Overload DFP, and the European Society of Radiology, review the basics of liver fibrosis, fat, and iron quantification with MRI and liver fibrosis and fat quantification with US. The authors cover technical requirements, typical case display, quality control and proper measurement technique and case interpretation guidelines, pitfalls, and confounding factors. The authors aim to provide a practical guide for radiologists interpreting these examinations. © RSNA, 2023 See the invited commentary by Ronot in this issue. Quiz questions for this article are available in the supplemental material.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Sobrecarga de Hierro , Hepatopatías , Humanos , Hierro , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/patología , Hígado/diagnóstico por imagen , Hígado/patología , Imagen por Resonancia Magnética/métodos , Hepatopatías/patología , Sobrecarga de Hierro/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Radiólogos , Biomarcadores
15.
J Comput Assist Tomogr ; 47(6): 882-889, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37948362

RESUMEN

ABSTRACT: The purpose of this article is to provide a comprehensive review of the imaging findings along with histopathologic correlation of mature (benign) teratomas and malignant ovarian teratomas, which include both immature teratomas and malignant degeneration of mature teratomas. The radiologist's ability to provide an accurate diagnosis plays an essential role in guiding the interdisciplinary care of patients with malignant teratomas and improving their outcomes.


Asunto(s)
Neoplasias Ováricas , Teratoma , Femenino , Humanos , Imagen Multimodal , Teratoma/diagnóstico por imagen , Teratoma/patología , Neoplasias Ováricas/diagnóstico por imagen
16.
Clin Gastroenterol Hepatol ; 20(6): e1292-e1304, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34400338

RESUMEN

BACKGROUND & AIMS: Strictures in Crohn's disease (CD) are classically attributed to fibromuscular hypertrophy of the intestinal wall. We have identified and characterized CD-related ileal strictures that result instead from mural constriction (ie, reduced external circumference). METHODS: Twenty-four strictures and internal controls from 17 adults with obstructive CD were analyzed by cross-sectional morphometry. RESULTS: The stricture-to-control circumference ratios (CRs) ranged from 0.53 to 1.7. Six strictures with CR ≥1.0, designated hypertrophic, had concentrically thickened walls, mean 3-fold increases in cross-sectional area and stainable fibromucular tissue, and high transmural inflammation scores. In contrast, 18 strictures with CR <1.0, designated constrictive, had thin, pliant walls, cross-sectional areas and stainable fibromuscular tissue comparable with control values, and low transmural inflammation scores. Eight mildly constrictive strictures also showed mild fibromuscular mural expansion that fell short of statistical significance. Twelve of 18 constrictive strictures (67%) occurred multiply (2-4 strictures per specimen) in contrast with hypertrophic strictures, all of which occurred singly (P = .01). Constriction correlated quantitatively with circumferential serosal fat wrapping (P = .003) and was associated with myenteric lymphocytic plexitis (P = .02). Disease duration was shortest among subjects with constrictive strictures and correlated with increasing circumference (CR ≤0.8, 6.3 ± 6.2 years; CR >0.8, 8.7 ± 6.4 years; and CR ≥1.00, 13.7 ± 5.0 years, respectively; P = .03). CONCLUSIONS: Constrictive ileal strictures in CD differ pathologically and clinically from hypertrophic strictures, featuring little or no fibromuscular mural expansion, frequent multiplicity, and earlier onset. Mesenteric fat wrapping and myenteric plexitis may contribute to their pathogenesis. Pathologic manifestations of constriction and hypertrophy can coexist, suggesting that stricture heterogeneity may be shaped in part by the dynamics of constrictive and hypertrophic processes.


Asunto(s)
Enfermedad de Crohn , Enfermedades del Íleon , Obstrucción Intestinal , Adulto , Constricción , Constricción Patológica/patología , Enfermedad de Crohn/complicaciones , Enfermedad de Crohn/patología , Humanos , Hipertrofia/complicaciones , Inflamación , Obstrucción Intestinal/etiología , Obstrucción Intestinal/patología
17.
J Magn Reson Imaging ; 55(6): 1745-1758, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34767682

RESUMEN

BACKGROUND: Diffusion-weighted imaging (DWI) is commonly used to detect prostate cancer, and a major clinical challenge is differentiating aggressive from indolent disease. PURPOSE: To compare 14 site-specific parametric fitting implementations applied to the same dataset of whole-mount pathologically validated DWI to test the hypothesis that cancer differentiation varies with different fitting algorithms. STUDY TYPE: Prospective. POPULATION: Thirty-three patients prospectively imaged prior to prostatectomy. FIELD STRENGTH/SEQUENCE: 3 T, field-of-view optimized and constrained undistorted single-shot DWI sequence. ASSESSMENT: Datasets, including a noise-free digital reference object (DRO), were distributed to the 14 teams, where locally implemented DWI parameter maps were calculated, including mono-exponential apparent diffusion coefficient (MEADC), kurtosis (K), diffusion kurtosis (DK), bi-exponential diffusion (BID), pseudo-diffusion (BID*), and perfusion fraction (F). The resulting parametric maps were centrally analyzed, where differentiation of benign from cancerous tissue was compared between DWI parameters and the fitting algorithms with a receiver operating characteristic area under the curve (ROC AUC). STATISTICAL TEST: Levene's test, P < 0.05 corrected for multiple comparisons was considered statistically significant. RESULTS: The DRO results indicated minimal discordance between sites. Comparison across sites indicated that K, DK, and MEADC had significantly higher prostate cancer detection capability (AUC range = 0.72-0.76, 0.76-0.81, and 0.76-0.80 respectively) as compared to bi-exponential parameters (BID, BID*, F) which had lower AUC and greater between site variation (AUC range = 0.53-0.80, 0.51-0.81, and 0.52-0.80 respectively). Post-processing parameters also affected the resulting AUC, moving from, for example, 0.75 to 0.87 for MEADC varying cluster size. DATA CONCLUSION: We found that conventional diffusion models had consistent performance at differentiating prostate cancer from benign tissue. Our results also indicated that post-processing decisions on DWI data can affect sensitivity and specificity when applied to radiological-pathological studies in prostate cancer. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 3.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Neoplasias de la Próstata , Imagen de Difusión por Resonancia Magnética/métodos , Humanos , Masculino , Estudios Prospectivos , Neoplasias de la Próstata/diagnóstico por imagen , Curva ROC , Estudios Retrospectivos , Sensibilidad y Especificidad
18.
Eur Radiol ; 32(9): 6493-6503, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35380226

RESUMEN

BACKGROUND AND AIMS: Transarterial 90Y radioembolization (TARE) is increasingly being used for hepatocellular carcinoma (HCC) treatment. However, tumor response assessment after TARE may be challenging. We aimed to assess the diagnostic performance of gadoxetate disodium MRI for predicting complete pathologic necrosis (CPN) of HCC treated with TARE, using histopathology as the reference standard. METHODS: This retrospective study included 48 patients (M/F: 36/12, mean age: 62 years) with HCC treated by TARE followed by surgery with gadoxetate disodium MRI within 90 days of surgery. Two radiologists evaluated tumor response using RECIST1.1, mRECIST, EASL, and LI-RADS-TR criteria and evaluated the percentage of necrosis on subtraction during late arterial, portal venous, and hepatobiliary phases (AP/PVP/HBP). Statistical analysis included inter-reader agreement, correlation between radiologic and pathologic percentage of necrosis, and prediction of CPN using logistic regression and ROC analyses. RESULTS: Histopathology demonstrated 71 HCCs (2.8 ± 1.7 cm, range: 0.5-7.5 cm) including 42 with CPN, 22 with partial necrosis, and 7 without necrosis. EASL and percentage of tumor necrosis on subtraction at the AP/PVP were independent predictors of CPN (p = 0.02-0.03). Percentage of necrosis, mRECIST, EASL, and LI-RADS-TR had fair to good performance for diagnosing CPN (AUCs: 0.78 - 0.83), with a significant difference between subtraction and LI-RADS-TR for reader 2, and in specificity between subtraction and other criteria for both readers (p-range: 0.01-0.04). Radiologic percentage of necrosis was significantly correlated to histopathologic degree of tumor necrosis (r = 0.66 - 0.8, p < 0.001). CONCLUSIONS: Percentage of tumor necrosis on subtraction and EASL criteria were significant independent predictors of CPN in HCC treated with TARE. Image subtraction should be considered for assessing HCC response to TARE when using MRI. KEY POINTS: • Percentage of tumor necrosis on image subtraction and EASL criteria are significant independent predictors of complete pathologic necrosis in hepatocellular carcinoma treated with90Y radioembolization. • Subtraction, mRECIST, EASL, and LI-RADS-TR have fair to good performance for diagnosing complete pathologic necrosis in hepatocellular carcinoma treated with90Y radioembolization.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Carcinoma Hepatocelular/radioterapia , Gadolinio DTPA , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/radioterapia , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Necrosis , Estudios Retrospectivos , Radioisótopos de Itrio
19.
Eur Radiol ; 32(3): 2030-2040, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34564745

RESUMEN

OBJECTIVES: To assess the precision of MRI radiomics features in hepatocellular carcinoma (HCC) tumors and liver parenchyma. METHODS: The study population consisted of 55 patients, including 16 with untreated HCCs, who underwent two repeat contrast-enhanced abdominal MRI exams within 1 month to evaluate: (1) test-retest repeatability using the same MRI system (n = 28, 10 HCCs); (2) inter-platform reproducibility between different MRI systems (n = 27, 6 HCCs); (3) inter-observer reproducibility (n = 16, 16 HCCs). Shape and 1st- and 2nd-order radiomics features were quantified on pre-contrast T1-weighted imaging (WI), T1WI portal venous phase (pvp), T2WI, and ADC (apparent diffusion coefficient), on liver regions of interest (ROIs) and HCC volumes of interest (VOIs). Precision was assessed by calculating intraclass correlation coefficient (ICC), concordance correlation coefficient (CCC), and coefficient of variation (CV). RESULTS: There was moderate to excellent test-retest repeatability of shape and 1st- and 2nd-order features for all sequences in HCCs (ICC: 0.53-0.99; CV: 3-29%), and moderate to good test-retest repeatability of 1st- and 2nd-order features for T1WI sequences, and 2nd-order features for T2WI in the liver (ICC: 0.53-0.73; CV: 12-19%). There was poor inter-platform reproducibility for all features and sequences, except for shape and 1st-order features on T1WI in HCCs (CCC: 0.58-0.99; CV: 3-15%). Good to excellent inter-observer reproducibility was found for all features and sequences in HCCs (CCC: 0.80-0.99; CV: 4-15%) and moderate to good for liver (CCC: 0.45-0.86; CV: 6-25%). CONCLUSIONS: MRI radiomics features have acceptable repeatability in the liver and HCC when using the same MRI system and across readers but have low reproducibility across MR systems, except for shape and 1st-order features on T1WI. Data must be interpreted with caution when performing multiplatform radiomics studies. KEY POINTS: • MRI radiomics features have acceptable repeatability when using the same MRI system but less reproducible when using different MRI platforms. • MRI radiomics features extracted from T1 weighted-imaging show greater stability across exams than T2 weighted-imaging and ADC. • Inter-observer reproducibility of MRI radiomics features was found to be good in HCC tumors and acceptable in liver parenchyma.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagen , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados , Estudios Retrospectivos
20.
Eur Radiol ; 32(12): 8339-8349, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35727321

RESUMEN

OBJECTIVES: Portal hypertension (PH) is associated with complications such as ascites and esophageal varices and is typically diagnosed through invasive hepatic venous pressure gradient (HVPG) measurement, which is not widely available. In this study, we aim to assess the diagnostic performance of 2D/3D MR elastography (MRE) and shear wave elastography (SWE) measures of liver and spleen stiffness (LS and SS) and spleen volume, to noninvasively diagnose clinically significant portal hypertension (CSPH) using HVPG measurement as the reference. METHODS: In this prospective study, patients with liver disease underwent 2D/3D MRE and SWE of the liver and spleen, as well as HVPG measurement. The correlation between MRE/SWE measures of LS/SS and spleen volume with HVPG was assessed. ROC analysis was used to determine the utility of MRE, SWE, and spleen volume for diagnosing CSPH. RESULTS: Thirty-six patients (M/F 22/14, mean age 55 ± 14 years) were included. Of the evaluated parameters, 3D MRE SS had the strongest correlation with HVPG (r = 0.686, p < 0.001), followed by 2D MRE SS (r = 0.476, p = 0.004). 3D MRE SS displayed the best performance for diagnosis of CSPH (AUC = 0.911) followed by 2D MRE SS (AUC = 0.845) and 3D MRE LS (AUC = 0.804). SWE SS showed poor performance for diagnosis of CSPH (AUC = 0.583) while spleen volume was a fair predictor (AUC = 0.738). 3D MRE SS was significantly superior to SWE LS/SS (p ≤ 0.021) for the diagnosis of CSPH. CONCLUSION: SS measured with 3D MRE outperforms SWE for the diagnosis of CSPH. SS appears to be a useful biomarker for assessing PH severity. These results need further validation. KEY POINTS: • Spleen stiffness measured with 2D and 3D MR elastography correlates significantly with hepatic venous pressure gradient measurement. • Spleen stiffness measured with 3D MR elastography demonstrates excellent performance for the diagnosis of clinically significant portal hypertension (AUC 0.911). • Spleen stiffness measured with 3D MR elastography outperforms liver and spleen stiffness measured with shear wave elastography for diagnosis of clinically significant portal hypertension.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hipertensión Portal , Humanos , Adulto , Persona de Mediana Edad , Anciano , Diagnóstico por Imagen de Elasticidad/métodos , Estudios Prospectivos , Cirrosis Hepática/complicaciones , Hipertensión Portal/complicaciones , Hipertensión Portal/diagnóstico por imagen , Hipertensión Portal/patología , Presión Portal , Hígado/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA