1.
J Chromatogr A ; 1676: 463216, 2022 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-35777138

RESUMEN

The introduction of additives has revolutionized super/subcritical fluid chromatography (SFC) by expanding the range of compounds that could be analyzed by the technique. From being considered a mere extension of gas chromatography, incorporation of a modifier, and subsequently an additive has made SFC a workhorse for chiral separations. Additives are by far the smallest component of the SFC mobile phase but can result in changing the polarity and acidity of the mobile phase, suppression of ionization, deactivation of the stationary phase, and act as an ion pairing agent. A wide variety of compounds have been tested as additives including but not limited to diethylamine, trifluoroacetic acid, ammonium acetate, and water. This review summarizes the different role played by additives in the SFC mobile phase. Further this work aims to help the reader by critically evaluating different additives used in enantiomeric separations with packed column SFC.


Asunto(s)
Cromatografía con Fluido Supercrítico , Cromatografía Liquida , Cromatografía con Fluido Supercrítico/métodos , Estereoisomerismo , Ácido Trifluoroacético/química , Agua
2.
J Chromatogr A ; 1638: 461878, 2021 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-33477025

RESUMEN

Method screening is an integral part of chromatographic method development for the separation of racemates. Due to the highly complex retention mechanism of a chiral stationary-phase, it is often difficult, if not impossible, to device predefined method-development steps that can be successfully applied to a wide group of molecules. The standard approach is to evaluate or screen a series of stationary and mobile-phase combinations to increase the chances of detecting a suitable separation condition. Such a process is often the rate-limiting step for high-throughput analyses and purification workflows. To address the problem, several solutions and strategies have been proposed over the years for reduction of net method-screening time. Some of the strategies have been adopted in practice while others remained confined in the literature. The main objective of this review is to revisit, critically discuss and compile the solutions published over the last two decades. We expect that making the diverse set of solutions available in a single document will help assessing the adequacy of existing screening protocols in laboratories conducting chiral separation.


Asunto(s)
Cromatografía/métodos , Cromatografía/tendencias , Cromatografía con Fluido Supercrítico , Heurística , Publicaciones , Solventes/química , Estereoisomerismo
3.
J Chromatogr A ; 1651: 462308, 2021 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-34157473

RESUMEN

Preparative chiral separations are carried out using chiral stationary-phases (CSP) employing isocratic composition mode to take advantage of stacking multiple injections within a single continuous operation. Development of the separation method, however, is not conducted directly in the preparative systems. Chromatographic systems at analytical scale are set up to screen multiple CSPs with various mobile-phases (MP) to detect a suitable CSP-MP combination. For faster method screening, solvent-gradients are implemented - operating from low to higher modifier composition, e.g. 5 to 70%. Once the right CSP-MP pair is detected, the isocratic method for preparative separation is developed through further experimental trials in the analytical system. The scope of the trial steps is generally limited to detecting a "good-enough" separation condition through one or two isocratic experiments. Ideally, the analyst should scout all possible isocratic conditions to detect the most suitable method; which, however, is not possible in high-throughput separation laboratories. In this report we demonstrate the utility of a simple set of algebraic equations, supported by an experimental protocol, in generating complete isocratic method options based on minimum number of experimental trials. The approach presented here was developed for chiral separation with supercritical-fluid chromatography. We also suggest an approach to identify an isocratic composition for the purification step. The process proposed in this report should be useful in developing better preparative separation methods in high-throughput laboratories.


Asunto(s)
Técnicas de Química Analítica/métodos , Cromatografía con Fluido Supercrítico , Modelos Químicos , Solventes/química , Estereoisomerismo
4.
J Chromatogr A ; 1623: 461178, 2020 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-32505281

RESUMEN

Estimation of injection volume during a preparative chiral separation can be challenging. Commonly one attempts to maximize the injection volume to reduce total separation time. The factors that limit increasing injection volume are (a) purity constraint(e.g. enantiomeric excess) and (b) criterion of product recovery. Standard industrial practice is to successively inject increasing volume of sample mixture until two adjoining peaks (e.g. peaks of two enantiomers) touch respective baselines. Separation scientists may spend considerable time and material to detect this injection volume before starting the stack-injection run. This increased method-development time increases time spent on the instrument, resulting in decreased efficiency. In this report we demonstrate the utility of a mathematical model-based approach that can be employed for faster estimation of this optimum injection volume. Note that the model does not intend to detect the theoretical maximum injection volume, rather tries to mimic the experimental optimization approach through simulation. The method requires experimental data from one initial trial run as input to predict the final "optimum" injection volume, thus saving time and material compared to situations that require multiple trial runs. The proposed model is simple enough to be implemented in a Microsoft Excel spreadsheet, but offers reasonably accurate estimation. Although the example presented in this report is of preparative separation of a racemic mixture with supercritcal fluid chromatography (SFC), in general the model is applicable to any preparative separation under isocratic conditions where the chromatographic peak follows Langmuir adsorption isotherm behavior. A description of the fundamental basis of the model is presented here along with experimental results that demonstrate its utility.


Asunto(s)
Cromatografía con Fluido Supercrítico/métodos , Adsorción , Cromatografía Liquida , Modelos Teóricos , Estereoisomerismo
5.
J Chromatogr A ; 1195(1-2): 67-77, 2008 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-18502431

RESUMEN

Re-chromatography or recycling impure products obtained from the batch runs of solvent gradient chromatography is commonly practiced in industry to improve product yield. However, as the re-chromatography steps are carried out at the expense of running fresh batches, any improvement in the yield comes as a trade-off with the production time, and hence productivity. In recent studies, on the other hand, it has been suggested that with a properly designed recycling process one can not only improve the yield, but the productivity as well. That study, however, considered a steady-state recycling process, a technology yet to be implemented with bio-chromatographic systems. In the present paper we are reporting a study made on non-steady-state recycling or re-chromatography, as it is typically done in industrial practice. The results point out an amendment to the standard way of designing solvent gradients, which is necessary to improve both the yield and the productivity of an industrial run with recycle. Although the test case used here was the separation of an industrial peptide, Calcitonin, in a reversed-phase column, the general methodology of gradient manipulation, needless to say, is also valid for other solvent gradient processes like ion-exchange, HIC, etc.


Asunto(s)
Cromatografía Liquida/métodos , Solventes/química , Calcitonina/química , Calcitonina/aislamiento & purificación , Modelos Teóricos , Reproducibilidad de los Resultados
6.
J Chromatogr A ; 1183(1-2): 87-99, 2008 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-18243221

RESUMEN

With significant advancement in the upstream processing technology, downstream processing of large bio-molecules is becoming the bottle-neck in the production chain. To face this challenge, design and development of efficient separation processes has become crucial. As a step towards boosting the performance of a chromatographic separation process through improved design, we investigated the potential of recycling as a process option. The most important advantage of recycling is that it can be implemented in an existing batch system without any major investment and consultation. Although impure products are recycled in industries, it is done as additional batch, and only then, when the recoverable product is valuable enough to surpass the loss of productivity in running the additional batches. In our study, on the other hand, it was found that a well-designed recycle can not only improve the yield, but also the productivity of a multi-component purification. A series of multiobjective optimization studies were carried out on multi-component separation to comprehend the role of recycling with reference to an industrially relevant problem, i.e. the chromatographic purification step of the production process of calcitonin.


Asunto(s)
Cromatografía Liquida/métodos , Conservación de los Recursos Naturales , Solventes/química , Calcitonina/aislamiento & purificación
7.
J Chromatogr A ; 1532: 182-190, 2018 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-29195661

RESUMEN

Following a recent publication [1], the topic of turbulent flow in SFC has generated both interest and questions. Liquid-like density, coupled with significantly low viscosity of CO2-based mobile-phases may result in high Reynolds number (Re) - higher than what represents laminar flow conditions, reaching the so-called turbulent regions. Although such turbulent flows can form only in the connecting tubings, thus not directly affecting the chromatographic process, it is important to know under many situations, whether the flow inside the tubing is laminar or turbulent. In this report a comprehensive guideline to identify the possibilities of turbulent flow conditions is provided through a series of charts. Flow properties depend on state conditions (composition, pressure and temperature) and also on the tubing material and geometry. Here guidelines to detect the onset of turbulent conditions is provided for cylindrical stainless-steel tubings of different internal diameters (i.d.) under a wide range of SFC mobile-phase conditions.


Asunto(s)
Cromatografía con Fluido Supercrítico/métodos , Reología , Solventes/química , Dióxido de Carbono/química , Presión , Temperatura , Viscosidad
8.
Artículo en Inglés | MEDLINE | ID: mdl-29803196

RESUMEN

Hyphenating SFC with MS is now routinely performed in analytical laboratories. Major instrument providers supply commercial solutions for coupling SFC and MS, which has facilitated wider adoption of the technology. The current status, however, could be achieved based on the work done by many researchers over decades. Interfacing SFC with MS posed some unique challenges, compared to interfacing MS with LC or GC, demanding special solutions. Several interface designs were tried and tested over the years before suitable solutions could be detected. Additional measures, such as (a) mixing SFC mobile-phase with an additional liquid solvent at the column outlet, and (b) heating the interfacing device, had to be adopted to address some specific challenges. Although such modifications and measures look diverse, there is one factor that drove most of them - compressibility of SFC mobile-phase. There are two objectives of this review - (1) to compile various insights which were reported on describing and optimizing SFC-MS interfacing processes, and (2) to link these insights with the fundamental issue of solvent compressibility.


Asunto(s)
Cromatografía con Fluido Supercrítico , Espectrometría de Masas , Cromatografía con Fluido Supercrítico/instrumentación , Cromatografía con Fluido Supercrítico/métodos , Diseño de Equipo , Espectrometría de Masas/instrumentación , Espectrometría de Masas/métodos , Proyectos de Investigación , Solubilidad , Solventes , Temperatura
9.
J Pharm Biomed Anal ; 161: 414-424, 2018 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-30216790

RESUMEN

Supercritical Fluid Chromatography (SFC) has known a strong regain of interest for the last 10 years, especially in the field of pharmaceutical analysis. Besides the development and validation of the SFC method in one individual laboratory, it is also important to demonstrate its applicability and transferability to various laboratories around the world. Therefore, an inter-laboratory study was conducted and published for the first time in SFC, to assess method reproducibility, and evaluate whether this chromatographic technique could become a reference method for quality control (QC) laboratories. This study involved 19 participating laboratories from 4 continents and 9 different countries. It included 5 academic groups, 3 demonstration laboratories at analytical instrument companies, 10 pharmaceutical companies and 1 food company. In the initial analysis of the study results, consistencies within- and between-laboratories were deeply examined. In the subsequent analysis, the method reproducibility was estimated taking into account variances in replicates, between-days and between-laboratories. The results obtained were compared with the literature values for liquid chromatography (LC) in the context of impurities determination. Repeatability and reproducibility variances were found to be similar or better than those described for LC methods, and highlighted the adequacy of the SFC method for QC analyses. The results demonstrated the excellent and robust quantitative performance of SFC. Consequently, this complementary technique is recognized on equal merit to other chromatographic techniques.


Asunto(s)
Cromatografía con Fluido Supercrítico/normas , Contaminación de Medicamentos/prevención & control , Cooperación Internacional , Cromatografía Liquida/métodos , Cromatografía Liquida/normas , Cromatografía con Fluido Supercrítico/métodos , Control de Calidad , Reproducibilidad de los Resultados
10.
J Chromatogr A ; 1167(1): 42-53, 2007 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-17765250

RESUMEN

Solvent gradient chromatography is quite often used in analytical studies for decreasing the analysis time of samples having components with widely different retention behaviour. Several studies, both theoretical and experimental, have been reported on the optimization of gradient profiles in improving analytical separation performance, suggesting various linear and non-linear gradients. In preparative chromatography, on the other hand, though solvent gradient is being increasingly used (especially in bioseparation) to improve the product yield and productivity, there is a dearth of literature and clearer understanding of the effect(s) of modifier gradients on the separation performance. For this, the gradients used in applications are of relatively simple profiles like step or linear gradients, obtained through hand optimization based on experience and intuition. Significant improvements, however, can be expected using the state-of-the art modelling of chromatographic processes and optimization routines running on widely available hi-speed desktop computers. In this work we are reporting such an optimization procedure to improve the purification of an industrial multi-component mixture, containing 65.8% of Calcitonin as the main product, in an overloaded reversed-phase column. The work comprises both theoretical simulations and their experimental validation using multilinear gradients as optimization variable. The study produced interesting insights for modifier gradient design, like using peak deformation of the target peptide to increase yield and productivity, and improved our understanding of the effect of modifier gradients in non-linear separations.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Cromatografía por Intercambio Iónico/métodos , Cromatografía Liquida/métodos , Modelos Teóricos , Solventes/análisis , Solventes/química , Adsorción , Algoritmos , Calcitonina/química , Calibración , Interacciones Hidrofóbicas e Hidrofílicas , Dinámicas no Lineales , Solventes/clasificación , Espectrofotometría Ultravioleta , Termodinámica
11.
J Chromatogr A ; 1482: 65-75, 2017 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-28057333

RESUMEN

Scaling methods, either from analytical to analytical systems or from analytical to preparative systems and vice versa, are commonly performed in chromatography. For liquid chromatography there exist geometric rules for scaling, which provide guidelines to select column dimensions, particle sizes and flow rates. For SFC, on the other hand, there are no such rules or any well-understood principles behind scaling. In a recent report [1] this issue was addressed, proposing a rule of maintaining the same average density in the target system as it was in the original system. The problem with the criterion of maintaining average density, however, is the availability of density data. Not only one needs access and relevant experience of working with physical property data, in many cases density data may not be available at all. The current report demonstrates that a simpler approach, of matching average pressures, is equally applicable for acceptable scaling over most of the operating conditions used in SFC.


Asunto(s)
Cromatografía con Fluido Supercrítico/métodos , Tamaño de la Partícula , Presión
12.
J Chromatogr A ; 1511: 122-131, 2017 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-28689578

RESUMEN

This paper focuses on the possibility to inject large volumes (up to 10µL) in ultra-high performance supercritical fluid chromatography (UHPSFC) under generic gradient conditions. Several injection and method parameters have been individually evaluated (i.e. analyte concentration, injection volume, initial percentage of co-solvent in the gradient, nature of the weak needle wash solvent, nature of the sample diluent, nature of the column and of the analyte). The most critical parameters were further investigated using in a multivariate approach. The overall results suggested that several aprotic solvents including methyl tert-butyl ether (MTBE), dichloromethane, acetonitrile or cyclopentyl methyl ether (CPME) were well adapted for the injection of large volume in UHPSFC, while MeOH was generally the worst alternative. However, the nature of the stationary phase also had a strong impact and some of these diluents did not perform equally on each column. This was due to the existence of a competition in the adsorption of the analyte and the diluent on the stationary phase. This observation introduced the idea that the sample diluent should not only be chosen according to the analyte but also to the column chemistry to limit the interactions between the diluent and the ligands. Other important characteristics of the "ideal" SFC sample diluent were finally highlighted. Aprotic solvents with low viscosity are preferable to avoid strong solvent effects and viscous fingering, respectively. In the end, the authors suggest that the choice of the sample diluent should be part of the method development, as a function of the analyte and the selected stationary phase.


Asunto(s)
Cromatografía con Fluido Supercrítico/métodos , Solventes/química , Acetonitrilos/química , Éteres Metílicos/química , Cloruro de Metileno/química , Preparaciones Farmacéuticas/análisis
13.
J Chromatogr A ; 1406: 316-23, 2015 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-26116187

RESUMEN

This paper aims to demonstrate the effect of pressure variations in modifying analyte retention behavior in SFC. There is a general understanding that in SFC increasing pressure decreases the retention factor (k'), and vice versa. What is not clearly discussed or explained in any recent literature is that these variations can be very different at different operating pressures, temperatures and modifier concentrations. It is important to have a clearer understanding on these variabilities during method development and results analysis. In this paper the nature of k' variation with pressure, at different temperatures and modifier concentrations, will be explained with the help of isopycnic plots of CO2 and CO2+methanol mixtures.


Asunto(s)
Técnicas de Química Analítica/normas , Cromatografía con Fluido Supercrítico/normas , Presión , Metanol/química , Temperatura
14.
J Chromatogr A ; 1366: 126-35, 2014 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-25267710

RESUMEN

We propose to use constant enthalpy or isenthalpic diagrams as a tool to estimate the extent of the temperature variations caused by the mobile phase pressure drop along a chromatographic column, e.g. of its cooling in supercritical fluid and its heating in ultra-performance liquid chromatography. Temperature strongly affects chromatographic phenomena. Any of its variations inside the column, whether intended or not, can lead to significant changes in separation performance. Although instruments use column ovens in order to keep constant the column temperature, operating conditions leading to a high pressure drop may cause significant variations of the column temperature, both in the axial and the radial directions, from the set value. Different ways of measuring these temperature variations are available but they are too inconvenient to be employed in many practical situations. In contrast, the thermodynamic plot-based method that we describe here can easily be used with only a ruler and a pencil. They should be helpful in developing methods or in analyzing results in analytical laboratories. Although the most effective application area for this approach should be SFC (supercritical fluid chromatography), it can be applied to any chromatographic conditions in which temperature variations take place along the column due to the pressure drop, e.g. in ultra-high pressure liquid chromatography (UHPLC). The method proposed here is applicable to isocractic conditions only.


Asunto(s)
Cromatografía , Temperatura , Cromatografía Líquida de Alta Presión , Cromatografía con Fluido Supercrítico , Modelos Teóricos , Presión , Termodinámica
15.
J Chromatogr A ; 1362: 278-93, 2014 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-25200534

RESUMEN

Scaling is regularly done in chromatography either to transfer a successfully designed method of analysis developed in one system to another system, or to scale-up a separation method developed in analytical scale to preparative scale. For liquid chromatography there are well-tested guidelines for scaling, which makes it a routine job. For supercritical fluid chromatography (SFC), on the other hand, neither do we have any well-understood principles behind scaling nor do we know how far the strategies applied in LC could be applicable to SFC. In this article, we have addressed these issues and proposed a rule applicable for scaling isocratic methods between different SFC systems and column dimensions under commonly used operating temperatures and pressures. We have shown that the scale-up and method transfer techniques used in LC can be applied to SFC, provided we ensure that both the original and the target systems in SFC operate at the same average density. The current article will present the theory, discuss the extents of applicability of this rule, and outline its limitations. In an accompanying article implementation of this rule in various practical situations will be presented.


Asunto(s)
Cromatografía con Fluido Supercrítico/métodos , Fenómenos Biomecánicos , Límite de Detección , Tamaño de la Partícula , Presión , Temperatura , Viscosidad
16.
J Chromatogr A ; 1323: 143-56, 2014 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-24315126

RESUMEN

The pressure, temperature and density drops along SFC columns eluted with a CO2/methanol mobile phase were measured and compared with theoretical values. For columns packed with 3- and 5-µm particles the pressure and temperature drops were measured using a mobile phase of 95% CO2 and 5% methanol at a flow rate of 5mL/min, at temperatures from 20 to 100°C, and outlet pressures from 80 to 300bar. The density drop was calculated based on the temperature and pressure at the column inlet and outlet. The columns were suspended in a circulating air bath, either bare or covered with foam insulation. The experimental measurements were compared to theoretical results obtained by numerical simulation. For the convective air condition at outlet pressures above 100bar the average difference between the experimental and calculated temperature drops and pressure drops were 0.1°C and 0.7% for the bare 3-µm column, respectively, and were 0.6°C and 4.1% for the insulated column. The observed temperature drops for the insulated columns are consistent with those predicted by the Joule-Thomson coefficients for isenthalpic expansion. The dependence of the temperature and the pressure drops on the Joule-Thomson coefficient and kinematic viscosity are described for carbon dioxide mobile phases containing up to 20% methanol.


Asunto(s)
Dióxido de Carbono/química , Cromatografía con Fluido Supercrítico/métodos , Metanol/química , Presión , Temperatura , Aire , Fenómenos Biomecánicos , Modelos Teóricos , Termodinámica , Incertidumbre , Viscosidad
17.
J Chromatogr A ; 1285: 148-58, 2013 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-23477796

RESUMEN

Previous reports have highlighted the influence of the properties of the mobile phase flow rate on the column performance achieved in supercritical fluid chromatography (SFC). In SFC both the mass and the volumetric flow rates have unique influences on the chromatographic performance and the determination of their exact values is critical. It is well understood that the mass flow rate stays constant along an SFC system whereas the volumetric flow rate may vary considerably, but the extent of these variations and the role of the individual operating parameters in influencing these variations have not been clearly reported yet. The factors that control the mass and the volumetric flow rates in an SFC system are discussed and the possible extent of variations of these flow rates under different operating pressures and temperatures are demonstrate quantitatively.


Asunto(s)
Cromatografía con Fluido Supercrítico/instrumentación , Cromatografía con Fluido Supercrítico/métodos , Dióxido de Carbono/química , Calor , Metanol/química , Presión
18.
J Chromatogr A ; 1290: 73-81, 2013 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-23582857

RESUMEN

A theory is proposed to relate the elution times of the adsorption front shocks of breakthrough curves recorded during classical dynamic frontal analysis (FA) experiments with selected compounds and their adsorption isotherms in solid/supercritical fluid adsorption systems. The actual density and viscosity of binary mixtures of CO2 and methanol were obtained from the NIST REPPROP software. Diluted solutions of S-naproxen were considered (<2% in mass) but the possible effects of the analyte concentration on the viscosity and the density of the eluent percolating through the column were neglected. This allows the determination of the excess adsorption isotherm (or Gibbs excess isotherm) of the adsorbed analyte in the whole column at constant mass and volumetric flow rate of pure CO2 and of the modifier solution. A local Langmuir adsorption isotherm and a constant saturation capacity were assumed in the calculations. The variation of the adsorption-desorption constant with the eluent density was taken from the experimental variation of the retention factor of S-naproxen on a chiral column packed with Whelk-O1 particles. The results show that the isotherm parameters obtained from the best adjustment of the Langmuir model to the SFC excess adsorption data deviates by less than 7% from the assumed saturation capacity and from the average of the equilibrium constant along the chromatographic column. In practice, this conclusion holds true provided that the precision of the measurement of elution times of front shocks of breakthrough curves is better than 1% and that the maximum surface coverage qexp,max/qS is at least equal to 20%.


Asunto(s)
Cromatografía con Fluido Supercrítico/métodos , Adsorción , Metanol/química , Modelos Teóricos , Naproxeno/química , Presión , Viscosidad
19.
J Chromatogr A ; 1320: 130-7, 2013 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-24210558

RESUMEN

This work demonstrates the possible advantages and the challenges of accurate on-line measurements of the CO2 mass flow rate during supercritical fluid chromatography (SFC) operations. Only the mass flow rate is constant along the column in SFC. The volume flow rate is not. The critical importance of accurate measurements of mass flow rates for the achievement of reproducible data and the serious difficulties encountered in supercritical fluid chromatography for its assessment were discussed earlier based on the physical properties of carbon dioxide. In this report, we experimentally demonstrate the problems encountered when performing mass flow rate measurements and the gain that can possibly be achieved by acquiring reproducible data using a Coriolis flow meter. The results obtained show how the use of a highly accurate mass flow meter permits, besides the determination of accurate values of the mass flow rate, a systematic, constant diagnosis of the correct operation of the instrument and the monitoring of the condition of the carbon dioxide pump.


Asunto(s)
Cromatografía con Fluido Supercrítico/métodos , Cromatografía con Fluido Supercrítico/normas , Reproducibilidad de los Resultados
20.
J Chromatogr A ; 1314: 276-87, 2013 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-24054420

RESUMEN

The adsorption isotherms of the naproxen enantiomers were measured on a Kromasil Whelk-O1 column, eluted with mixtures of supercritical carbon dioxide and methanol or ethanol. Five chromatographic methods were used: frontal analysis, frontal analysis by characteristic points, elution by characteristic points, retention time method and the inverse method. In all methods, the effects of the two modifiers were compared. The use of these methods suffers from limitations due to supercritical fluid chromatographic instruments. These problems and drawbacks are discussed. The accurate and precise determination of the isotherm parameters was not possible with the instrument currently used. In contrast, the different methods allow to show qualitatively that the adsorption of the naproxen enantiomers show heterogeneous mechanism on the adsorbent surface common in chiral chromatography. Finally, the experimental high concentration elution band profiles of naproxen are compared with those calculated from the isotherm parameters provided by the five different methods.


Asunto(s)
Antiinflamatorios no Esteroideos/química , Cromatografía con Fluido Supercrítico/métodos , Naproxeno/química , Termodinámica , Adsorción , Estereoisomerismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA