Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 135
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Am Heart J ; 259: 30-41, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36642226

RESUMEN

BACKGROUND: The impact of using direct-to-consumer wearable devices as a means to timely detect atrial fibrillation (AF) and to improve clinical outcomes is unknown. METHODS: Heartline is a pragmatic, randomized, and decentralized application-based trial of US participants aged ≥65 years. Two randomized cohorts include adults with possession of an iPhone and without a history of AF and those with a diagnosis of AF taking a direct oral anticoagulant (DOAC) for ≥30 days. Participants within each cohort are randomized (3:1) to either a core digital engagement program (CDEP) via iPhone application (Heartline application) and an Apple Watch (Apple Watch Group) or CDEP alone (iPhone-only Group). The Apple Watch Group has the watch irregular rhythm notification (IRN) feature enabled and access to the ECG application on the Apple Watch. If an IRN notification is issued for suspected AF then the study application instructs participants in the Apple Watch Group to seek medical care. All participants were "watch-naïve" at time of enrollment and have an option to either buy or loan an Apple Watch as part of this study. The primary end point is time from randomization to clinical diagnosis of AF, with confirmation by health care claims. Key secondary endpoint are claims-based incidence of a 6-component composite cardiovascular/systemic embolism/mortality event, DOAC medication use and adherence, costs/health resource utilization, and frequency of hospitalizations for bleeding. All study assessments, including patient-reported outcomes, are conducted through the study application. The target study enrollment is approximately 28,000 participants in total; at time of manuscript submission, a total of 26,485 participants have been enrolled into the study. CONCLUSION: The Heartline Study will assess if an Apple Watch with the IRN and ECG application, along with application-facilitated digital health engagement modules, improves time to AF diagnosis and cardiovascular outcomes in a real-world environment. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04276441.


Asunto(s)
Fibrilación Atrial , Embolia , Tromboembolia , Adulto , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Tromboembolia/diagnóstico , Tromboembolia/etiología , Tromboembolia/prevención & control , Hemorragia
2.
J Cardiovasc Electrophysiol ; 34(2): 257-267, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36378803

RESUMEN

BACKGROUND: Implantable cardioverter defibrillators (ICD) are indicated for primary and secondary prevention of sudden cardiac arrest. Despite enhancements in design and technologies, the ICD lead is the most vulnerable component of the ICD system and failure of ICD leads remains a significant clinical problem. A novel, small-diameter, lumenless, catheter-delivered, defibrillator lead was developed with the aim to improve long-term reliability. METHODS AND RESULTS: The Lead Evaluation for Defibrillation and Reliability (LEADR) study is a multi-center, single-arm, Bayesian, adaptive design, pre-market interventional pivotal clinical study. Up to 60 study sites from around the world will participate in the study. Patients indicated for a de novo ICD will undergo defibrillation testing at implantation and clinical assessments at baseline, implant, pre-hospital discharge, 3 months, 6 months, and every 6 months thereafter until official study closure. Patients may be participating for a minimum of 18 months to approximately 3 years. Fracture-free survival will be evaluated using a Bayesian statistical method that incorporates both virtual patient data (combination of bench testing to failure with in-vivo use condition data) with clinical patients. The clinical subject sample size will be determined using decision rules for number of subject enrollments and follow-up time based upon the observed number of fractures at certain time points in the study. The adaptive study design will therefore result in a minimum of 500 and a maximum of 900 patients enrolled. CONCLUSION: The LEADR Clinical Study was designed to efficiently provide evidence for short- and long-term safety and efficacy of a novel lead design using Bayesian methods including a novel virtual patient approach.


Asunto(s)
Desfibriladores Implantables , Paro Cardíaco , Humanos , Teorema de Bayes , Reproducibilidad de los Resultados , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Resultado del Tratamiento
3.
J Cardiovasc Electrophysiol ; 34(3): 693-699, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36640426

RESUMEN

INTRODUCTION: Contact force has been used to titrate lesion formation for radiofrequency ablation. Pulsed field ablation (PFA) is a field-based ablation technology for which limited evidence on the impact of contact force on lesion size is available. METHODS: Porcine hearts (n = 6) were perfused using a modified Langendorff set-up. A prototype focal PFA catheter attached to a force gauge was held perpendicular to the epicardium and lowered until contact was made. Contact force was recorded during each PFA delivery. Matured lesions were cross-sectioned, stained, and the lesion dimensions measured. RESULTS: A total of 82 lesions were evaluated with contact forces between 1.3 and 48.6 g. Mean lesion depth was 4.8 ± 0.9 mm (standard deviation), mean lesion width was 9.1 ± 1.3 mm, and mean lesion volume was 217.0 ± 96.6 mm3 . Linear regression curves showed an increase of only 0.01 mm in depth (depth = 0.01 × contact force + 4.41, R2 = 0.05), 0.03 mm in width (width = 0.03 × contact force + 8.26, R2 = 0.13) for each additional gram of contact force, and 2.20 mm3 in volume (volume = 2.20 × contact force + 162, R2 = 0.10). CONCLUSION: Increasing contact force using a bipolar, biphasic focal PFA system has minimal effects on acute lesion dimensions in an isolated porcine heart model and achieving tissue contact is more important than the force with which that contact is made.


Asunto(s)
Ablación por Catéter , Ablación por Radiofrecuencia , Porcinos , Animales , Ablación por Catéter/métodos , Ablación por Radiofrecuencia/métodos , Pericardio , Catéteres , Irrigación Terapéutica
4.
J Cardiovasc Electrophysiol ; 34(1): 54-61, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36259719

RESUMEN

INTRODUCTION: Catheter ablation for atrial fibrillation (AF) is frequently used for the purpose of rhythm control and improved quality of life (QoL). Although success rates are high, a significant proportion of patients require redo ablation. Data are scarce on patient-centered outcomes and QoL in patients undergoing redo AF ablation. We aimed to assess QoL and clinical outcomes using a large prospectively maintained patient-reported outcomes (PRO) registry. METHODS: All patients undergoing redo AF ablation (2013-2016) at our center were enrolled in a prospective registry for outcomes and assessed for QoL using automated PRO surveys (baseline, 3 and 6 months after ablation, every 6 months thereafter). Data were collected over 3 years of follow-up. The atrial fibrillation symptom severity scale (AFSSS) was used as the main measure for QoL. Additional variables included patient-reported improvement, AF burden, and AF-related healthcare utilization including emergency room (ER) visits and hospitalizations. RESULTS: A total of 848 patients were included (28% females, mean age 63.8, 51% persistent AF). By automated PRO, significant improvement in QoL was noted (baseline median AFSSS of 12 [5-18] and ranged between 2 and 4 on subsequent assessments; p < .0001), with ≥70%of patients reported remarkable improvement in their AF-related symptoms. The proportion of patients in AF at the time of baseline survey was 36%, and this decreased to <8% across all time points during follow-up (p < .0001). AF burden was significantly reduced (including frequency and duration of episodes; p < .0001), with an associated decrease in healthcare utilization after 6 months from the time of ablation (including ER visits and hospitalizations; p < .0001). The proportion of patients on anticoagulants or antiarrhythmics decreased on follow-up across all time points (p < .0001 for all variables). CONCLUSION: Most patients derive significant QoL benefit from redo AF ablation; with reduction of both AF burden and healthcare utilization.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Femenino , Humanos , Persona de Mediana Edad , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Calidad de Vida , Resultado del Tratamiento , Antiarrítmicos/uso terapéutico , Ablación por Catéter/efectos adversos , Medición de Resultados Informados por el Paciente
5.
Catheter Cardiovasc Interv ; 101(1): 187-196, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36378620

RESUMEN

BACKGROUND: New-onset left bundle branch block (LBBB) can develop after transcatheter aortic valve replacement (TAVR) resulting in worse outcomes. AIMS: Describe clinical and echocardiographic outcomes with new-onset LBBB after TAVR. METHODS: We included consecutive patients who underwent transfemoral-TAVR with SAPIEN-3 (S3) valve between April 2015 and December 2018. Exclusion criteria included pre-existing LBBB, right BBB, left anterior hemiblock, left posterior hemiblock, wide QRS ≥ 120ms, prior permanent pacemaker (PPM), and nontransfemoral access. RESULTS: Among 612 patients, 11.4% developed new-onset LBBB upon discharge. The length of stay was longer with new-onset LBBB compared with no LBBB [3 (2-5) days versus 2 (1-3) days; p < 0.001]. New-onset LBBB was associated with higher rates of 30-day PPM requirement (18.6% vs. 5.4%; p < 0.001) and 1-year heart failure hospitalizations (10.7% vs. 4.4%; p = 0.033). There was no difference in 3-year mortality between both groups (30.9% vs. 30.6%; p = 0.829). Further, new-onset LBBB was associated with lower left ventricular ejection fraction (LVEF) at both 30 days (55.9 ± 11.4% vs. 59.3 ± 9%; p = 0.026) and 1 year (55 ± 12% vs. 60.1 ± 8.9%; p = 0.002). These changes were still present when we stratified patients according to baseline LVEF (≥50% or <50%). New-onset LBBBs were associated with a higher 1-year LV end-diastolic volume index (51.4 ± 18.6 vs. 46.4 ± 15.1 ml/m2 ; p = 0.036), and LV end-systolic volume index (23.2 ± 14.1 vs. 18.9 ± 9.7 ml/m2 ; p = 0.009). Compared with resolved new-onset LBBB, persistent new-onset LBBB was associated with worse LVEF and higher PPM at 1 year. CONCLUSIONS: New-onset LBBB after S3 TAVR was associated with higher PPM requirement, worse LVEF, higher LV volumes, and increased heart failure hospitalizations, with no difference in mortality.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Volumen Sistólico , Función Ventricular Izquierda , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Arritmias Cardíacas , Ecocardiografía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
6.
J Drugs Dermatol ; 22(5): 496-501, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-37133483

RESUMEN

Dermatologic surgeons are encountering more patients on antithrombotic agents. There are no established consensus guidelines for managing antithrombotic agents in the perioperative period. We provide an updated overview of antithrombotic agents in dermatologic surgery and management of such agents in the perioperative period with additional unique perspectives from cardiology and pharmacy. A literature search of PubMed and Google Scholar was performed to review the English-language medical literature. The landscape of antithrombotic therapy is changing with a notable rise in the use of direct oral anticoagulants (DOACs.) While no consensus guidelines exist, most studies recommend continuing antithrombotic therapy in the perioperative period with appropriate lab monitoring, when applicable. However, recent data suggest it is safe to hold DOACs in the perioperative period. As antithrombotic therapy evolves, the dermatologic surgeon needs to remain current with the most recent available data. Where data are limited, a multidisciplinary approach to managing these agents in the perioperative period is essential. J Drugs Dermatol. 2023;22(5): doi:10.36849/JDD.7456.


Asunto(s)
Cardiología , Fibrinolíticos , Humanos , Fibrinolíticos/efectos adversos , Anticoagulantes/efectos adversos , Procedimientos Quirúrgicos Dermatologicos/efectos adversos
7.
N Engl J Med ; 380(20): 1895-1905, 2019 05 16.
Artículo en Inglés | MEDLINE | ID: mdl-30883056

RESUMEN

BACKGROUND: Infections after placement of cardiac implantable electronic devices (CIEDs) are associated with substantial morbidity and mortality. There is limited evidence on prophylactic strategies, other than the use of preoperative antibiotics, to prevent such infections. METHODS: We conducted a randomized, controlled clinical trial to assess the safety and efficacy of an absorbable, antibiotic-eluting envelope in reducing the incidence of infection associated with CIED implantations. Patients who were undergoing a CIED pocket revision, generator replacement, or system upgrade or an initial implantation of a cardiac resynchronization therapy defibrillator were randomly assigned, in a 1:1 ratio, to receive the envelope or not. Standard-of-care strategies to prevent infection were used in all patients. The primary end point was infection resulting in system extraction or revision, long-term antibiotic therapy with infection recurrence, or death, within 12 months after the CIED implantation procedure. The secondary end point for safety was procedure-related or system-related complications within 12 months. RESULTS: A total of 6983 patients underwent randomization: 3495 to the envelope group and 3488 to the control group. The primary end point occurred in 25 patients in the envelope group and 42 patients in the control group (12-month Kaplan-Meier estimated event rate, 0.7% and 1.2%, respectively; hazard ratio, 0.60; 95% confidence interval [CI], 0.36 to 0.98; P = 0.04). The safety end point occurred in 201 patients in the envelope group and 236 patients in the control group (12-month Kaplan-Meier estimated event rate, 6.0% and 6.9%, respectively; hazard ratio, 0.87; 95% CI, 0.72 to 1.06; P<0.001 for noninferiority). The mean (±SD) duration of follow-up was 20.7±8.5 months. Major CIED-related infections through the entire follow-up period occurred in 32 patients in the envelope group and 51 patients in the control group (hazard ratio, 0.63; 95% CI, 0.40 to 0.98). CONCLUSIONS: Adjunctive use of an antibacterial envelope resulted in a significantly lower incidence of major CIED infections than standard-of-care infection-prevention strategies alone, without a higher incidence of complications. (Funded by Medtronic; WRAP-IT ClinicalTrials.gov number, NCT02277990.).


Asunto(s)
Antibacterianos/administración & dosificación , Profilaxis Antibiótica , Infecciones Bacterianas/prevención & control , Desfibriladores Implantables/efectos adversos , Cardiopatías/terapia , Minociclina/administración & dosificación , Marcapaso Artificial/efectos adversos , Infecciones Relacionadas con Prótesis/prevención & control , Rifampin/administración & dosificación , Anciano , Antibacterianos/efectos adversos , Infecciones Bacterianas/epidemiología , Infecciones Bacterianas/mortalidad , Femenino , Humanos , Incidencia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Minociclina/efectos adversos , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/mortalidad , Rifampin/efectos adversos , Método Simple Ciego , Nivel de Atención
8.
J Cardiovasc Electrophysiol ; 33(9): 1994-2000, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35689504

RESUMEN

INTRODUCTION: Pulmonary venous (PV) electrical recovery underlies most arrhythmia recurrences after atrial fibrillation (AF) ablation. Little is known about procedural profiles and outcomes of patients with electrically silent PVs upon redo ablation for AF. METHODS: In a prospectively maintained registry, we enrolled 838 consecutive patients (2013-2016) undergoing redo ablation procedures. Ablation procedures targeted the PVs, the PV antra, and non-PV sites at operators' discretion. Procedural profiles and clinical outcomes were assessed. The primary outcome was freedom from AF after a 3-month blanking period. The secondary outcome was improvement in quality of life. RESULTS: Most patients undergoing redo AF ablation (n = 684, 82%) had PV reconnection while the remaining 154 (18%) had electrically silent PVs. Patients with recurrent AF and electrically silent PVs were older (66 vs. 64 years, p = .02), had more prior ablation procedures (median 2 IQR 1-3 vs 1 IQR 1-2 p = .001), were more likely to have non-paroxysmal AF (62% vs. 49%, p = .004) and atrial flutter (48% vs. 29%, p = .001) and had significantly larger left atrial volumes (89 vs. 81 ml, p = .003). Patients with silent PVs underwent a more extensive non-PV ablation strategies with antral extension of prior ablation sets in addition to ablation of the roof, appendage, inferior to the right PVs, peri-mitral flutter lines, cavotricuspid isthmus lines and ablation in the coronary sinus. Upon one year of follow-up, patients with electrically silent PVs were less likely to remain free from recurrent atrial arrhythmias (64% vs. 76%, p = .008). Regardless of PV reconnection status, redo ablation resulted in improvement in quality of life. CONCLUSION: Rhythm control with extensive ablation allowed maintenance of sinus rhythm in about two thirds of patients with silent PVs during redo AF ablation procedures. Regardless of PV reconnection status, redo ablation resulted in improvement in quality of life. This remains a challenging group of patients, highlighting the need to better understand non-PV mediated AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Venas Pulmonares/cirugía , Calidad de Vida , Recurrencia , Resultado del Tratamiento
9.
J Cardiovasc Electrophysiol ; 32(7): 1909-1917, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33955116

RESUMEN

BACKGROUND: Activation maps of scar-related atrial tachycardias (AT) can be challenging to interpret due to difficulty in inaccurate annotation of electrograms, and an arbitrarily predefined mapping window. A novel mapping software integrating vector data and applying an algorithmic solution taking into consideration global activation pattern has been recently described (Coherent™, Biosense Webster "Investigational"). OBJECTIVE: We aimed to assess the investigational algorithm to determine the mechanism of AT compared with the standard algorithm. METHODS: This study included patients who underwent ablation of scar-related AT using the Carto 3 and the standard activation algorithm. The mapping data were analyzed retrospectively using the investigational algorithm, and the mechanisms were evaluated by two independent electrophysiologists. RESULTS: A total of 77 scar-related AT activation maps were analyzed (89.6% left atrium, median tachycardia cycle length of 273 ms). Of those, 67 cases with a confirmed mechanism of arrhythmia were used to compare the activation software. The actual mechanism of the arrhythmia was more likely to be identified with the investigational algorithm (67.2% vs. 44.8%, p = .009). In five patients with dual-loop circuits, 3/5 (60%) were correctly identified by the investigational algorithm compared to 0/5 (0%) with the standard software. The reduced atrial voltage was prone to lead to less capable identification of mechanism (p for trend: .05). The investigational algorithm showed higher inter-reviewer agreement (Cohen's kappa .62 vs. .47). CONCLUSIONS: In patients with scar-related ATs, activation mapping algorithms integrating vector data and "best-fit" propagation solution may help in identifying the mechanism and the successful site of termination.


Asunto(s)
Ablación por Catéter , Cicatriz , Algoritmos , Cicatriz/diagnóstico , Técnicas Electrofisiológicas Cardíacas , Humanos , Estudios Prospectivos , Estudios Retrospectivos , Taquicardia
10.
Catheter Cardiovasc Interv ; 98(1): E127-E138, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33010100

RESUMEN

BACKGROUND: Baseline conduction abnormalities are known risk factors for permanent pacemaker (PPM) implantation after transcatheter aortic valve replacement (TAVR). We sought to determine the impact of baseline right bundle branch block (RBBB), left bundle branch block (LBBB), left anterior hemiblock (LAHB), first-degree atrioventricular block (AVB) and atrial fibrillation/flutter (AF) on TAVR outcomes. METHODS: Consecutive patients who underwent transfemoral TAVR with SAPIEN-3 (S3) were included. We excluded patients with prior PPM, nontransfemoral access or valve-in-valve. RESULTS: Among 886 patients, baseline RBBB was seen in 15.9%, LBBB in 6.3%, LAHB in 6.2%, first-degree AVB in 26.3% and AF in 37.5%. The rate of 30-day PPM was 10.1%. Baseline RBBB (OR 4.005; 95% CI 2.386-6.723; p < .001) and first-degree AVB (OR 1.847; 95% CI 1.133-3.009; p = .014) were independent predictors of 30 day PPM. LAHB also resulted in higher PPM rates but only in unadjusted analysis (21.8% vs. 9.4%; p = .003). Baseline LBBB and AF were associated with lower left ventricular ejection fraction (LVEF) at both baseline and 1 year after TAVR. However, Δ LVEF over time were noted to be similar with baseline LBBB (1.8% vs. 1.4%; p = .809) and AF (1.1% vs. 1.7%; p = .458). Moreover, baseline AF was also associated with higher stroke/transient ischemic attack (TIA) at 1 year (4.4% vs. 1.8%; p = .019), 1-year major adverse cardiac and cerebrovascular events (MACCE) (19.5% vs. 13.3%; p = .012) and 2 year mortality (23.5% vs. 15.2%; p = .016). None of the other baseline conduction defects affected long-term mortality or MACCE. CONCLUSION: In our S3 TAVR population, baseline RBBB and first-degree AVB predicted higher PPM risk. Prior LBBB and AF were associated with lower LVEF at both baseline and 1 year. Lastly, preexisting AF was associated with higher rates of mortality, stroke/TIA, and MACCE.


Asunto(s)
Estenosis de la Válvula Aórtica , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Factores de Riesgo , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Función Ventricular Izquierda
11.
Value Health ; 24(7): 930-938, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34243836

RESUMEN

OBJECTIVES: To model the cost-effectiveness of the TYRX Absorbable Antibacterial Envelope when used in patients at increased risk of cardiac implantable electronic device (CIED) infection in the context of 3 European healthcare systems: Germany, Italy, and England. METHODS: A decision tree model with a lifetime horizon was populated using data from the Worldwide Randomized Antibiotic Envelope Infection Prevention Trial, a large multicenter randomized controlled trial. Use of the antibacterial envelope adjunctive to standard of care was compared to standard of care infection prevention alone. Patients in the model were divided into subgroups based on presence of factors known to increase infection risk. RESULTS: The antibacterial envelope had the most favorable cost-effectiveness profile when patients had previously experienced CIED infection, had a history of immunosuppressive therapy, or had a Prevention of Arrhythmia Device Infection Trial (PADIT) score indicating high risk of infection (scores ≥6) at cost-effectiveness thresholds of €50 000 in Germany (assumed in the absence of an official threshold), €40 000 in Italy, and £30 000 in England. Probabilistic sensitivity analysis indicated that the antibacterial envelope was likely to be cost-effective in patients with other risk factors (including replacement of high power CIEDs, generator replacement with lead modification, and PADIT scores indicating intermediate risk of infection) when used with some device types and in some countries. CONCLUSIONS: The absorbable antibacterial envelope was associated with cost-effectiveness ratios below European benchmarks in selected patients at increased risk of infection, suggesting the envelope provides value for European healthcare systems by reducing CIED infections.


Asunto(s)
Profilaxis Antibiótica/economía , Análisis Costo-Beneficio , Control de Infecciones , Marcapaso Artificial/microbiología , Árboles de Decisión , Europa (Continente) , Humanos
12.
Europace ; 23(23 Suppl 4): iv28-iv32, 2021 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-34160597

RESUMEN

Cardiovascular implantable electronic devices (CIED) are effective and important components of modern cardiovascular care. Despite the dramatic improvements in the functionality and reliability of these devices, over time patients are at risk for developing several morbidities, the most feared of which are local and systemic infections. Despite significant financial investment and aggressive therapy with hospitalization, intravenous antibiotics, and transvenous lead extraction, the outcomes include a 1-year mortality rate as high as 25%. This risk of infection has increased over time, likely due to the increased complexity of the surgical interventions required to insert and replace these devices. The only way to reduce this morbidity and mortality is to prevent these infections, and other than preoperative antibiotics, there were little data supporting effective therapy until the WRAP-IT trial provided randomized data showing that pocket infections can be reduced by 60% at 12 months and major CIED infections reduced by 40% at 1 year with the use of the absorbable antibiotic eluting envelope in patient CIED procedures at high risk of infection. Not all CIED procedures are at high risk of infection and justify the use of the envelope, but cost-effectiveness data support the use of the antibiotic envelope particularly in patients with defibrillator replacements, revisions, and upgrades, such as to a resynchronization device and in patients with prior CIED infection, history of immunocompromise, two or more prior procedures, or a history of renal dysfunction.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Antibacterianos/efectos adversos , Profilaxis Antibiótica , Humanos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/prevención & control , Reproducibilidad de los Resultados , Tecnología
13.
Europace ; 23(23 Suppl 4): iv33-iv44, 2021 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-34160600

RESUMEN

The occurrence of cardiac implantable electronic devices (CIED) infections and related adverse outcomes have an important financial impact on the healthcare system, with hospitalization length of stay (2-3 weeks on average) being the largest cost driver, including the cost of device system extraction and device replacement accounting for more than half of total costs. In the recent literature, the economic profile of the TYRX™ absorbable antibacterial envelope was analysed taking into account both randomized and non-randomized trial data. Economic analysis found that the envelope is associated with cost-effectiveness ratios below USA and European benchmarks in selected patients at increased risk of infection. Therefore, the TYRX™ envelope, by effectively reducing CIED infections, provides value according to the criteria of affordability currently adopted by USA and European healthcare systems.


Asunto(s)
Desfibriladores Implantables , Infecciones Relacionadas con Prótesis , Antibacterianos/uso terapéutico , Análisis Costo-Beneficio , Desfibriladores Implantables/efectos adversos , Electrónica , Humanos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/prevención & control
14.
Europace ; 23(9): 1446-1455, 2021 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-33755136

RESUMEN

AIM: The Prevention of Arrhythmia Device Infection Trial (PADIT) infection risk score, developed based on a large prospectively collected data set, identified five independent predictors of cardiac implantable electronic device (CIED) infection. We performed an independent validation of the risk score in a data set extracted from U.S. healthcare claims. METHODS AND RESULTS: Retrospective identification of index CIED procedures among patients aged ≥18 years with at least one record of a CIED procedure between January 2011 and September 2014 in a U.S health claims database. PADIT risk factors and major CIED infections (with system removal, invasive procedure without system removal, or infection-attributable death) were identified through diagnosis and procedure codes. The data set was randomized by PADIT score into Data Set A (60%) and Data Set B (40%). A frailty model allowing multiple procedures per patient was fit using Data Set A, with PADIT score as the only predictor, excluding patients with prior CIED infection. A data set of 54 042 index procedures among 51 623 patients with 574 infections was extracted. Among patients with no history of prior CIED infection, a 1 unit increase in the PADIT score was associated with a relative 28% increase in infection risk. Prior CIED infection was associated with significant incremental predictive value (HR 5.66, P < 0.0001) after adjusting for PADIT score. A Harrell's C-statistic for the PADIT score and history of prior CIED infection was 0.76. CONCLUSION: The PADIT risk score predicts increased CIED infection risk, identifying higher risk patients that could potentially benefit from targeted interventions to reduce the risk of CIED infection. Prior CIED infection confers incremental predictive value to the PADIT score.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Adolescente , Adulto , Arritmias Cardíacas/terapia , Desfibriladores Implantables/efectos adversos , Atención a la Salud , Electrónica , Humanos , Marcapaso Artificial/efectos adversos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/prevención & control , Estudios Retrospectivos , Factores de Riesgo
15.
J Cardiovasc Electrophysiol ; 31(5): 1182-1186, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32108406

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) is indicated in patients with medically refractory heart failure and wide QRS duration. While much is known about predictors of left ventricular (LV) remodeling after CRT implantation and short-term mortality, limited data exist on long-term outcomes after CRT placement. METHODS: We retrospectively reviewed all patients undergoing CRT implantation at our center between 2003 and 2008 and examined mortality using institutional electronic records, social security death index, and online obituary search. We included only patients with preimplant echoes with LV ejection fraction (LVEF) 35% or below. Variable selection was performed using stepwise regression and models were compared using goodness-of-fit criteria. A final model was validated with the bootstrap regression method. RESULTS: Out of the 877 CRT patients undergoing implantation during this time, 287 (32.7%) survived longer than 10 years. Significant (P < .05) predictors of survival in our multivariate model were age, left ventricular diastolic diameter, sex, presence of nonischemic vs ischemic cardiomyopathy, QRS duration, atrial fibrillation, BNP levels, and creatinine levels at the time of CRT implantation. A model using the odds ratios from these variables had a receiver operating curve with an area under the curve score of 0.816 (standard error, 0.019) at predicting survival or freedom from LVAD or heart transplant for longer than 10 years after CRT implantation. The specificity for factors 3 or above and 5 or above was 68% and 77%, respectively. CONCLUSION: A large proportion of patients are still alive 10 years after CRT implantation. Variables at the time of CRT implant can help provide prognostic information to patients and electrophysiologists to determine the long-term benefit and survival of patients after CRT implantation.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/terapia , Anciano , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/mortalidad , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Recuperación de la Función , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Sobrevivientes , Factores de Tiempo , Resultado del Tratamiento
16.
J Card Fail ; 26(3): 227-232, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31881279

RESUMEN

INTRODUCTION: Cardiac resynchronization therapy (CRT) has been shown to improve survival in patients with systolic heart failure, wide QRS duration, and left-bundle-branch-block. However, CRT outcomes stratified by right ventricular (RV) function at implant have not been well studied. METHODS: We retrospectively reviewed patients at Cleveland Clinic who underwent CRT implantation (n = 777) from 2003 to 2011 with a diagnosis of heart failure, echocardiography with both pre-CRT left ventricular ejection fraction (LVEF) ≤35% and available post-CRT echocardiography at 6 months post-implant. CRT response was defined as LVEF improvement ≥5%. Patients were separated into 2 groups: normal or mild RV dysfunction (n = 570) labeled Normal RV; moderate to severe dysfunction (n = 207) labeled RV DYSFXN based on qualitative echocardiography assessment. Survival was calculated as time from CRT implant to death, left ventricular assist device implant, or heart transplant. RESULTS: CRT response was significantly higher in patients with Normal RV (67%) compared with patients with RV DYSFXN (56%; P = .006). Kaplan-Meier analysis showed that CRT patients with Normal RV had significantly greater survival compared with patients with RV DYSFXN (P < .001). In multivariable Cox regression accounting for a priori covariates, RV DYSFXN was associated with worse survival (HR 1.41 [95% CI: 1.14-1.75], P = .002) and lower CRT response (HR 0.66 [95% CI: 0.44-0.97], P = .03). CONCLUSION: Baseline RV dysfunction at CRT implant is an important predictor of worsened left ventricular remodeling and survival in CRT patients.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Disfunción Ventricular Derecha , Insuficiencia Cardíaca/terapia , Humanos , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/terapia , Función Ventricular Izquierda
17.
Pacing Clin Electrophysiol ; 43(1): 118-122, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31782195

RESUMEN

BACKGROUND: Advancement of digital technology now allows patients to have access to data from their cardiac implantable electronic devices (CIEDs). However, patients' understanding regarding CIED data and perceived personal usability remain unclear. The present study is a prospective survey to examine patients' understanding of their CIEDs and their perception of what is important. METHODS: We screened 400 patients between July and December 2018 who presented to our outpatient clinic for a CIED interrogation. Patients received a one-page questionnaire asking baseline demographics, their perception about their own knowledge about their device, and multiple-choice questions in seven basic categories: type of CIED, original indication, functionality, manufacturer, number of active leads, estimated battery life, and number of shocks received. We compared these answers to their interrogation reports to assess accuracy. We also asked participants what they would like to be aware of regarding their CIED. RESULTS: From this cohort, 344 of 400 (86%) (62.9 ± 12.8 years and 64 % males) agreed to take the survey and were included in the analysis. At baseline, 63.2% agreed or strongly agreed that they were knowledgeable about their devices. The overwhelming majority of patients demonstrated CIED knowledge deficits in at least one content area (n = 294, 86%), or more than two content areas (n = 176, 51%). Patients agreed or strongly agreed that they had a desire to have information regarding each of the following: battery life (84%), activity level (79%), heart rate trend (75%), and ventricular arrhythmias (74%). CONCLUSION: There is a large discrepancy in patients' level of knowledge regarding their CIEDs and their wish to know more details. Future technologies should satisfy providers' goals to educate their patients with basic information and fulfill patients' desire to obtain more data from their CIEDs.


Asunto(s)
Acceso a la Información , Actitud Frente a la Salud , Desfibriladores Implantables/psicología , Marcapaso Artificial/psicología , Pacientes/psicología , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Encuestas y Cuestionarios
18.
J Cardiovasc Electrophysiol ; 30(9): 1569-1577, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31187543

RESUMEN

INTRODUCTION: Atrioventricular nodal re-entry tachycardia (AVNRT) is the most common, regular narrow-complex tachycardia. The established treatment is catheter ablation of the AV nodal slow pathway (SP). However, in a select group of patients with long PR intervals in sinus rhythm, SP ablation can lead to AV block due to the absence of robust anterograde conduction through the fast pathway (FP). This report aims to demonstrate that AV nodal FP ablation is a reasonable approach in patients with AVNRT and poor or absent anterograde FP conduction. METHODS AND RESULTS: Standard electrophysiology study techniques were used in the electrophysiology laboratory. Catheter ablations were performed using radiofrequency energy. Mapping of intracardiac activation was performed with electroanatomical mapping systems. Outcomes were assessed acutely during the procedure and during routine clinical follow-up. Six patients with first-degree AV block and recurrent AVNRT who underwent ablation of their tachycardia at our institution are presented. One patient underwent ablation of AV nodal SP resulting in high-degree AV block necessitating pacemaker implantation. The remaining five patients underwent ablation of the AV nodal FP guided by electroanatomical mapping of the earliest atrial activation in tachycardia. These five had successful treatment of the tachycardia with preservation of anterograde AV nodal conduction. Mapping and ablation approach to eliminate retrograde FP conduction are described. CONCLUSION: In select patients with AVNRT and poor anterograde FP conduction, retrograde FP ablation is reasonable and is less likely to result in AV block and pacemaker dependency.


Asunto(s)
Nodo Atrioventricular/cirugía , Ablación por Catéter , Frecuencia Cardíaca , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Potenciales de Acción , Adulto , Anciano , Anciano de 80 o más Años , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/fisiopatología , Nodo Atrioventricular/fisiopatología , Ablación por Catéter/efectos adversos , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
19.
Europace ; 21(10): 1476-1483, 2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31304532

RESUMEN

AIMS: Obesity decreases arrhythmia-free survival after atrial fibrillation (AF) ablation by mechanisms that are not fully understood. We investigated the impact of pre-ablation bariatric surgery (BS) on AF recurrence after ablation. METHODS AND RESULTS: In this retrospective observational cohort study, 239 consecutive morbidly obese patients (body mass index ≥40 kg/m2 or ≥35 kg/m2 with obesity-related complications) were followed for a mean of 22 months prior to ablation. Of these patients, 51 had BS prior to ablation, and our primary outcome was whether BS was associated with a lower rate of AF recurrence during follow-up. Adjustment for confounding was performed with multivariable Cox proportional hazard models and propensity-score based analyses. During a mean follow-up of 36 months after ablation, 10/51 patients (20%) in the BS group had recurrent AF compared with 114/188 (61%) in the non-BS group (P < 0.0001). In the BS group, 6 patients (12%) underwent repeat ablation compared with 77 patients (41%) in the non-BS group, (P < 0.0001). On multivariable analysis, the association between BS and lower AF recurrence remained significant. Similarly, after weighting and adjusting for the inverse probability of the propensity score, BS was still associated with a lower hazard of AF recurrence (hazard ratio 0.14, 95% confidence interval 0.05-0.39; P = 0.002). CONCLUSION: Bariatric surgery is associated with a lower AF recurrence after ablation. Morbidly obese patients should be considered for BS prior to AF ablation, though prospective multicentre studies should be performed to confirm our novel finding.


Asunto(s)
Fibrilación Atrial/etiología , Cirugía Bariátrica/métodos , Ablación por Catéter , Obesidad Mórbida/complicaciones , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Índice de Masa Corporal , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Obesidad Mórbida/epidemiología , Obesidad Mórbida/cirugía , Estudios Prospectivos , Recurrencia , Factores de Riesgo , Tasa de Supervivencia/tendencias , Resultado del Tratamiento , Estados Unidos/epidemiología
20.
J Cardiovasc Electrophysiol ; 29(4): 551-558, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29369441

RESUMEN

INTRODUCTION: Management of persistent atrial fibrillation (PersAF) remains challenging, and many patients are left on medical therapy after a failed first ablation. In patients with recurrent symptomatic arrhythmias after PersAF ablation, we aimed to compare outcomes of repeat ablation and medical therapy versus medical therapy alone. METHODS AND RESULTS: All 682 consecutive patients with recurrent symptomatic arrhythmia after a first ablation for PersAF at our institution (2005-2012) were included. Repeat ablation with continuation of medical therapy was performed in 364 patients (Group 1) and 318 were only medically managed (Group 2). The outcome of interest was freedom from arrhythmia recurrence beyond a 3-month blanking period. Separate analyses were performed to assess this endpoint totally off antiarrhythmics (primary endpoint) or alternatively with/without use of antiarrhythmics (secondary endpoint). Over a median follow-up of 26 months, 41.5% of Group 1 patients met the primary endpoint and remained free from arrhythmia recurrence off antiarrhythmics (vs. 14.5% in Group 2, P < 0.0001). At last follow-up, antiarrhythmics continued to be required for rhythm control in 40.1% and 46.2% of patients in Groups 1 and 2, respectively (P < 0.0001). The secondary endpoint was met in 60.2% versus 32.1% of patients in Groups 1 and 2, respectively (P < 0.0001). In multivariable Cox analyses, repeat ablation was associated with significant reduction in arrhythmia recurrences compared to medical therapy alone (HR 0.48, 95% CI 0.35-0.65, P < 0.0001). CONCLUSION: In patients with recurrent symptomatic arrhythmia after ablation of PersAF, repeat ablation was associated with significant reduction in arrhythmia recurrences compared to routine medical therapy alone.


Asunto(s)
Antiarrítmicos/uso terapéutico , Fibrilación Atrial/cirugía , Ablación por Catéter , Reoperación , Potenciales de Acción , Anciano , Antiarrítmicos/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Terapia Combinada , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Supervivencia sin Progresión , Recurrencia , Sistema de Registros , Reoperación/efectos adversos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA