Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 100(5): 915-922, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36054254

RESUMEN

Despite easy access to imaging diagnostic procedures and an abundance of spatial data, most cardiac interventions are still performed under two-dimensional fluoroscopy. Incorporating anatomical data from scans into procedures plans has the potential to improve the swiftness and outcomes of percutaneous cardiac interventions. Therefore, procedure planning based on the specific anatomy is becoming a new standard of excellence in interventional cardiology. Still, we often tend to disregard specific spatial relations and the actual direction of catheter tip movement inside the body, relying on a try and error approach. The precise spatial orientation of instruments and prosthetic devices is crucial, especially during structural heart interventions. Here, we present how deliberate movements of objects under fluoroscopy can reveal the spatial orientation of catheters and other devices. We also propose a novel "two-point rule" for identifying three-dimensional relations between points in space. Understanding and applying this rule might substantially increase the spatial awareness of operators performing cardiovascular interventions. Although the concept is pretty simple, using it "live" during interventional cardiology procedures requires thorough understanding and practice. We propose the "two-point rule" as a crucial rule to develop expertise in spatial orientation under fluoroscopy and ensure high-quality outcomes.


Asunto(s)
Catéteres , Intervención Coronaria Percutánea , Humanos , Diseño de Equipo , Resultado del Tratamiento , Fluoroscopía , Cateterismo Cardíaco
2.
Curr Hypertens Rep ; 23(2): 12, 2021 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-33638064

RESUMEN

PURPOSE OF REVIEW: To analyze the impact of sodium retention states on the course of COVID-19 and propose possible interventions to curb disease progression. RECENT FINDINGS: Numerous data confirm a positive association of non-communicable diseases, aging, and other sodium-retaining states, including iatrogenic ones, with more severe sometimes fatal clinical course of COVID-19. Reasons for this effect could include increased angiotensin signaling via the AT1R receptor. The endothelial glycocalyx also plays an important role in infection, leading to a vicious cycle of inflammation and tissue sodium retention when damaged. RAS inhibitors may help restore glycocalyx function and prevent severe organ damage. Anticoagulants, especially heparin, may also have therapeutic applications due to antithrombotic, anti-inflammatory, glycocalyx-repairing, and antialdosteronic properties. The ambiguous influence of some diuretics on sodium balance was also discussed. Abnormal sodium storage and increased angiotensin-converting enzyme activity are related to the severity of COVID-19. Inducing sodium removal and reducing intake might improve outcomes.


Asunto(s)
COVID-19 , Hipertensión , Antagonistas de Receptores de Angiotensina , Inhibidores de la Enzima Convertidora de Angiotensina , Progresión de la Enfermedad , Humanos , SARS-CoV-2
3.
Catheter Cardiovasc Interv ; 86(2): E49-57, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25599675

RESUMEN

AIMS: The effectiveness of revascularization of chronic total occlusion (CTO) remains intriguing. Thus, we sought to investigate whether a successful PCI for single CTO improves outcomes in a setting of stable angina and chronic occlusion of single coronary artery. METHODS AND RESULTS: Of 11 957 consecutive patients referred for nonurgent PCI between 2003 and 2010, 1110 displayed single CTO and were enrolled to the central CTO-registry database. The primary end-point included all-cause mortality, the secondary end-point a composite of safety outcome measure of all-cause death, nonfatal-MI, the need for urgent revascularization and stroke. The major adverse cardiovascular event (MACE) records were extracted from the national administrative database and all patients were linked to the long-term follow-up. Since the patient assignment was not random, we performed the propensity scoring to minimize selection bias; 734 patients (66%) had a successful PCI-CTO. Compared with successful procedures, unsuccessful procedures had similar rates of all-cause death both in crude (HR, 0.78; 95%CI, 0.49-1.25; P = 0.30) and adjusted analysis (HR, 0.80; 95%CI, 0.50-1.28; P = 0.34). A similar, significant reduction in overall MACE was noted with successful PCI-CTO compared with unsuccessful procedure in unadjusted (HR, 0.74; 95%CI, 0.56-0.96; P = 0.020) and adjusted calculation (HR, 0.73; 95%CI, 0.56-0.96; P = 0.019). Patients after successful PCI-CTO as compared with failed recanalization less frequently underwent surgical revascularization. The benefit was sustained at 3 years follow-up. CONCLUSIONS: Successful PCI for single CTO does not improve long-term survival, nonetheless, is associated with reduced overall MACE and the need for surgical revascularization.


Asunto(s)
Angina Estable/terapia , Oclusión Coronaria/terapia , Intervención Coronaria Percutánea , Anciano , Angina Estable/diagnóstico , Angina Estable/fisiopatología , Distribución de Chi-Cuadrado , Enfermedad Crónica , Oclusión Coronaria/diagnóstico , Oclusión Coronaria/mortalidad , Oclusión Coronaria/fisiopatología , Femenino , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Infarto del Miocardio/etiología , Oportunidad Relativa , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Puntaje de Propensión , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/etiología , Factores de Tiempo , Resultado del Tratamiento
4.
Mediators Inflamm ; 2015: 395173, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26089601

RESUMEN

UNLABELLED: An inflammatory response plays a crucial role in myocardial damage after an acute myocardial infarction. OBJECTIVES: To measure serum concentrations of several mediators in patients with an acute myocardial infarction (STEMI) and to assess their potential relationship with a risk of coronary instability. PATIENTS AND METHODS: The 33 patients with STEMI and 19 healthy volunteers were analyzed. The clinical data were obtained; as well serum concentrations of tryptase, endothelin (ET-1), angiogenin, soluble c-kit, and PDGF were measured. RESULTS: Patients with STEMI had higher serum tryptase and ET-1 than healthy volunteers (2,5 ± 0,4 ng/mL versus 1,1 ± 0,4 ng/mL and 0,7 ± 0,1 ng/mL versus 0,3 ± 0,1 ng/mL, resp.). Subjects with significant lesion in left anterior descending artery (LAD) had lower serum ET-1 compared to those with normal LAD (0,6 ± 0,2 pg/mL versus 0,9 ± 0,4 pg/mL). Patients with three-vessel coronary artery disease (CAD) had higher level of soluble c-kit compared to those with one- or two-vessel CAD: 19,9 ± 24,1 ng/mL versus 5,6 ± 1,9 ng/mL. CONCLUSIONS: Elevated serum tryptase and ET-1 may be markers of increased coronary instability; some cytokines may be related to the extension of CAD.


Asunto(s)
Endotelinas/sangre , Infarto del Miocardio/sangre , Triptasas/sangre , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factor de Crecimiento Derivado de Plaquetas/metabolismo , Estudios Prospectivos , Proteínas Proto-Oncogénicas c-kit/sangre , Ribonucleasa Pancreática/sangre
5.
Am J Cardiol ; 217: 25-28, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38432337

RESUMEN

What is the efficacy and safety of transcatheter tricuspid valve-in-valve implantation for patients with inoperable tricuspid surgical prosthesis dysfunction? Thirty-day mortality after greatly effective transcatheter treatment is 2 times less than the estimated surgical risk.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Falla de Prótesis , Válvula Tricúspide/cirugía , Resultado del Tratamiento , Cateterismo Cardíaco , Diseño de Prótesis , Insuficiencia Cardíaca/cirugía
6.
Cardiol J ; 30(2): 188-195, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-34308536

RESUMEN

BACKGROUND: The purpose of this study was to compare the safety and clinical outcomes of transcarotid (TC) and transapical access (TA) transcatheter aortic valve implantation (TAVI) patients whom the transfemoral approach (TF) was not feasible. METHODS: The analysis included consecutive patients with severe symptomatic aortic stenosis treated from 2017 to 2020 with TC-TAVI or TA-TAVI in two high-volume TAVI centers. The approach was selected by multidisciplinary heart teams after analyzing multislice computed tomography of the heart, aorta and peripheral arteries, transthoracic echocardiography and coronary angiography. RESULTS: One hundred and two patients were treated with alternative TAVI accesses (TC; n = 49 and TA; n = 53) in our centers. The groups were similar regarding age, gender, New York Heart Association class, and echocardiography parameters. Patients treated with TC-TAVI had significantly higher surgical risk. The procedural success rate was similar in both groups (TC-TAVI 98%; TA-TAVI 98.1%; p = 0.95). The rate of Valve Academic Research Consortium-2 defined clinical events was low in both groups. The percentage of new-onset rhythm disturbances and permanent pacemaker implantation was similar in TC and TA TAVI (4.1% vs. 11.3%; p = 0.17 and 10.2% vs. 5.7%; p = 0.39, respectively). In the TA-TAVI group, significantly more cases of pneumonia and blood transfusions were observed (11% vs. 0%; p = 0.01 and 30.2% vs. 12.2%; p = 0.03). The 30-day mortality was similar in TC and TA groups (4.1% vs. 5.7%; p = 0.71, respectively). CONCLUSIONS: Both TC and TA TAVI are safe procedures in appropriately selected patients and are associated with a low risk of complications.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Ecocardiografía , Contraindicaciones , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos
7.
Postepy Kardiol Interwencyjnej ; 19(3): 251-256, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37854972

RESUMEN

Introduction: Data regarding patients with a previous medical record of immunosuppression treatment who have undergone transcatheter aortic valve implantation (TAVI) are limited and extremely inconclusive. Available studies are mostly short term observations; thus there is a lack of evidence on efficacy and safety of TAVI in this specific group of patients. Aim: To compare the in-hospital and long-term outcomes between patients with or without a medical history of immunosuppressive treatment undergoing TAVI for aortic valve stenosis (AS). Material and methods: We conducted a retrospective registry-based analysis including patients undergoing TAVI for AS at 5 centres between January 2009 and August 2017. The primary endpoint was long-term all-cause mortality. Secondary endpoints comprised major vascular complications, life-threatening or disabling bleeding, stroke and new pacemaker implantation. Results: Of 1451 consecutive patients who underwent TAVI, two propensity-matched groups including 25 patients with a history of immunosuppression and 75 patients without it were analysed. No differences between groups in all-cause mortality were found in a median follow-up time of 2.7 years following TAVI (p = 0.465; HR = 0.73; 95% CI: 0.30-1.77). The rate of major vascular complications (4.0% vs. 5.3%) was similar in the two groups (p = 1.000). There were no statistically significant differences in the composite endpoint combining life-threatening or disabling bleeding, major vascular complications, stroke and new pacemaker implantation (40.0% vs. 20.0%, p = 0.218). Conclusions: Patients who had undergone TAVI for AS had similar long-term mortality regardless of whether they had a previous medical record of immunosuppression. Procedural complication rates were comparable between the groups.

8.
Kardiol Pol ; 2023 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-37096948

RESUMEN

BACKGROUND: Valve-in-valve transcatheter transfemoral mitral valve implantation (ViV-TMVI) is an emerging treatment alternative to reoperation in high surgical risk patients with a failed mitral bioprostheses. AIM: To describe characteristics and evaluate 30-day outcomes of ViV-TMVI in the Polish population. METHODS: Nationwide registry was initiated to collect data of all patients with failed mitral bioprosthesis undergoing ViV-TMVI in Poland. This study presents 30-days clinical and echocardiographic follow-up. RESULTS: Overall, 27 ViV-TMVI were performed in 8 centers until May 2022 (85% since 2020). Mean (standard deviation [SD]) age was 73 (11.6) years with the median (interquartile range [IQR]) STS score of 5.3% (4.3%-14.3%). Mean (SD) time between surgical implantation and ViV-TMVI was 8.2 (3.2) years. Failed Hancock II (29%) and Perimount Magna (22%) were most frequently treated. Mechanisms of failure were equally often pure mitral regurgitation or stenosis (both 37%) with mixed etiology in 26%. Balloon-expandable Sapien 3/Ultra were used in all but 1 patient. Technical success was 96.3% (1 patient required additional prosthesis). Mean (SD) transvalvular mitral gradient reached 6.7 (2.2) mm Hg and mitral valve area was 1.8 (0.4) cm². None of the patients had moderate or severe mitral regurgitation with only 14.8% graded as mild. In 92.6% device success (2 patients had mean gradient ≥10 mm Hg) and in 85.6% procedural success was present. There were no deaths, cerebrovascular events or need for mitral valve surgery during 30-day follow-up. CONCLUSIONS: In short-term observation ViV-TMVI is safe and effective alternative for patients with failed mitral bioprosthesis at high surgical risk of re-operation. Longer observations on larger sample are warranted.

9.
Med Hypotheses ; 166: 110903, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35791352

RESUMEN

The Chinese scenario, a rapid increase in the frequency of SARS-CoV-2 infections and sudden decline, is uncommon worldwide. Enormous differences in COVID-19 severity among individual countries are the striking findings of the pandemics. It has been demonstrated that a mild course of COVID-19 is associated with gastrointestinal symptoms, less inflammatory response, and better prognosis. The presence of SARS-CoV-2 was observed longer in the gastrointestinal tract than in respiratory swabs, promoting feco-oral transmissions and mild virus attenuation. The spread of the pandemic and its severity might, consequently, depends on the dominant environmental route of infection and emerging immunity. We hypothesize that the feco-oral SARS-CoV-2 transmission may help to achieve the long-term immunity against COVID-19, since it enables the continuous contact with viral antigens in the gastrointestinal tract, resulting in lower mortality rate. To conclude, countries producing rice through traditional methods developed rapidly emerging long-lasting population immunity, possibly through increased SARS-CoV-2 antigen exposure in the gastrointestinal tract. Our hypothesis brings attention to this potential route of herd immunity against SARS-CoV-2 which warrants further investigation in the future.

10.
Biology (Basel) ; 11(2)2022 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-35205091

RESUMEN

Platelet-leucocyte aggregates (PLA) are a formation of leucocytes and platelets bound by specific receptors. They arise in the condition of sheer stress, thrombosis, immune reaction, vessel injury, and the activation of leukocytes or platelets. PLA participate in cardiovascular diseases (CVD). Increased levels of PLA were revealed in acute and chronic coronary syndromes, carotid stenosis cardiovascular risk factors. Due to accessible, available, replicable, quick, and low-cost quantifying using flow cytometry, PLA constitute an ideal biomarker for clinical practice. PLA are promising in early diagnosing and estimating prognosis in patients with acute or chronic coronary syndromes treated by percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG). PLA were also a reliable marker of platelet activity for monitoring antiplatelet therapy. PLA consist also targets potential therapies in CVD. All of the above potential clinical applications require further studies to validate methods of assay and proof clinical benefits.

12.
Artículo en Inglés | MEDLINE | ID: mdl-35329016

RESUMEN

Medicine is a rapidly-evolving discipline, with progress picking up pace with each passing decade. This constant evolution results in the introduction of new tools and methods, which in turn occasionally leads to paradigm shifts across the affected medical fields. The following review attempts to showcase how 3D printing has begun to reshape and improve processes across various medical specialties and where it has the potential to make a significant impact. The current state-of-the-art, as well as real-life clinical applications of 3D printing, are reflected in the perspectives of specialists practicing in the selected disciplines, with a focus on pre-procedural planning, simulation (rehearsal) of non-routine procedures, and on medical education and training. A review of the latest multidisciplinary literature on the subject offers a general summary of the advances enabled by 3D printing. Numerous advantages and applications were found, such as gaining better insight into patient-specific anatomy, better pre-operative planning, mock simulated surgeries, simulation-based training and education, development of surgical guides and other tools, patient-specific implants, bioprinted organs or structures, and counseling of patients. It was evident that pre-procedural planning and rehearsing of unusual or difficult procedures and training of medical professionals in these procedures are extremely useful and transformative.


Asunto(s)
Modelos Anatómicos , Impresión Tridimensional , Estudios Transversales , Humanos , Prótesis e Implantes
13.
EuroIntervention ; 18(7): 590-597, 2022 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-35608032

RESUMEN

BACKGROUND: Stroke remains a feared complication associated with transcatheter aortic valve implantation (TAVI). Embolic cerebral injury occurs in the majority of TAVI cases and can lead to cognitive dysfunction. AIMS: The PROTEMBO C Trial evaluated the safety and performance of the ProtEmbo Cerebral Protection System in TAVI patients. METHODS: Forty-one patients were enrolled in this single-arm study conducted at 8 European centres. The primary safety endpoint was the rate of VARC 2-defined major adverse cardiac and cerebrovascular events (MACCE) at 30 days; the primary performance endpoint was the composite rate of technical success versus performance goals (PG). Secondary endpoints included brain diffusion-weighted magnetic resonance imaging (DW-MRI), new lesion volume, and the rate of death or all strokes compared to historical data. RESULTS: Thirty-seven of 41 enrolled patients underwent TAVI with the ProtEmbo device (intention-to-treat [ITT] population). Both primary endpoints were met. MACCE at 30 days was 8.1% (upper limit of the 95% confidence interval [CI]: 21.3% vs PG 25%; p=0.009), and technical success was 94.6% (lower limit of the 95% CI: 82.3% vs PG 75%; p=0.003). New DW-MRI lesion volumes with ProtEmbo were smaller than in historical data, and 87% of patients completing MRI follow-up had no single lesion >150 mm3. There was 1 stroke in a patient in whom the device was removed prematurely before TAVI completion. CONCLUSIONS: The PROTEMBO C Trial met its primary safety and performance endpoints compared to prespecified historical PGs. Patients had smaller brain lesion volumes on DW-MRI compared to prior series and no larger single lesions. These results warrant further evaluation of the ProtEmbo in a larger randomised controlled trial (RCT).


Asunto(s)
Dispositivos de Protección Embólica , Reemplazo de la Válvula Aórtica Transcatéter , Imagen de Difusión por Resonancia Magnética , Dispositivos de Protección Embólica/efectos adversos , Humanos , Embolia Intracraneal/etiología , Embolia Intracraneal/prevención & control , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento
14.
Front Cardiovasc Med ; 9: 894497, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35800165

RESUMEN

Objectives: Patients with bicuspid aortic valve (BAV) stenosis were excluded from the pivotal trials of transcatheter aortic valve implantation (TAVI). We compared the in-hospital and long-term outcomes between patients undergoing TAVI for bicuspid and tricuspid aortic valve (TAV) stenosis. Methods: We performed a retrospective registry-based analysis on patients who underwent TAVI for BAV and TAV at five different centers between January 2009 and August 2017. The primary outcome was long-term all-cause mortality. Secondary outcomes were in-hospital mortality, procedural complications, and valve performance. Results: Of 1,451 consecutive patients who underwent TAVI, two propensity-matched cohorts consisting of 130 patients with BAV and 390 patients with TAV were analyzed. All-cause mortality was comparable in both groups up to 10 years following TAVI (HR 1.09, 95% CI: 0.77-1.51). Device success and in-hospital mortality were comparable between the groups (96 vs. 95%, p = 0.554 and 2.3 vs. 2.1%, p = 0.863, respectively). Incidence of procedural complications was similar in both groups, with a trend toward a higher rate of stroke in patients with BAV (5 vs. 2%, p = 0.078). Incidence of moderate or severe paravalvular leak (PVL) at discharge was comparable in both groups (2 vs. 2%, p = 0.846). Among patients with BAV, all-cause mortality was similar in self-expanding and balloon-expandable prostheses (HR 1.02, 95% CI: 0.52-1.99) and lower in new-generation devices compared to old-generation valves (HR 0.27, 95% CI 0.12-0.62). Conclusion: Patients who had undergone TAVI for BAV had comparable mortality to patients with TAV up to 10 years after the procedure. The device success, in-hospital mortality, procedural complications, and PVL rate were comparable between the groups. The high rate of neurological complications (5%) in patients with BAV warrants further investigation.

15.
Cardiol J ; 28(6): 831-841, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34355782

RESUMEN

BACKGROUND: Long-term results after stenting aorto-coronary ostial lesions (AOL) are worse than those achieved in non-ostial locations. AOL interventions still pose a substantial challenge for interventional cardiologists. The aim of the study was to determine the optimal fluoroscopic viewing angles of the left and right coronary ostia, based on multislice computed tomography (MSCT) data. METHODS: Cardiac MSCT exams of 30 patients with clinical suspicion of coronary artery disease were analyzed. En face angles of both coronary ostia, as well as their optimal projection curves, were determined by 2 independent observers in a standard Dicom viewer, without any additional, specialized software add-ons, using a systematic, step-by-step approach. Spatial relations between the ostial plane and the aorta were also assessed. RESULTS: The average en face angle of the left coronary ostium was RAO 23°, CAU 45°; for the right coronary ostium RAO 18°, CRA 5°. The mean inter-observer differences for the en face angles of the left and right coronary arteries were 5° and 7°, respectively. CONCLUSIONS: Multislice computed tomography data provide precise spatial information on the orientation of the coronary ostia and their relation to the aortic root. Their utilization for determining the patient-specific viewing angle may substantially facilitate percutaneous coronary interventions in AOL.


Asunto(s)
Vasos Coronarios , Tomografía Computarizada Multidetector , Angiografía Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Fluoroscopía , Corazón , Humanos , Stents , Resultado del Tratamiento
16.
Cardiol J ; 28(1): 77-85, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-31642052

RESUMEN

BACKGROUND: The purpose of this study was to analyze hemodynamic changes in patients treated with percutaneous coronary intervention (PCI) at an early stage of acute myocardial infarction (AMI) and at 1-month follow-up. METHODS: Patients with AMI (n = 27) who underwent PCI were analyzed using impedance cardiography (ICG). ICG data were collected continuously (beat by beat) during the whole PCI procedure and thereafter at every 60 s for the next 24 h. Blood pressure was taken every 10 min and stored for analysis. Additionally the following parameters were measured: cardiac index (CI), stroke volume index (SVi), left cardiac work index (LCWi), contractility index (CTi), ventricular ejection time (VET), systemic vascular resistance index (SVRi), thoracic fluid content index (TFCi) and heart rate (HR). RESULTS: In the first 24 h after PCI all the contractility parameters including CI, SVi, LCWi, CTi and VET significantly decreased, whereas HR, SVRi and TFCi increased compared to baseline. All of the parameters examined got normalized at 1 month. The CI, SVi, LCWi, CTi, SVRi did not significantly differ from baseline, however the HR and VET were significantly lower compared to first day after PCI CONCLUSIONS: Cardiac performance deteriorates early after PCI and normalizes after 1 month in patients with an AMI. ICG is useful for hemodynamic monitoring of AMI patients during and after invasive therapy.


Asunto(s)
Infarto del Miocardio , Intervención Coronaria Percutánea , Cardiografía de Impedancia , Humanos , Volumen Sistólico , Función Ventricular Izquierda
17.
Cardiol J ; 28(6): 825-830, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34490606

RESUMEN

BACKGROUND: The NAUTILUS study aimed to evaluate the safety and performance of the Allegra bioprosthesis in high-risk recipients undergoing transcatheter aortic valve implantation and previously reported 30-day outcomes. In the current investigation 1-year results of the trial are presented. METHODS: Twenty-seven recipients with severe, symptomatic aortic valve stenosis at high surgical risk, who underwent treatment using the next-generation self-expanding Allegra via transfemoral approach were prospectively enrolled. Clinical endpoints assessed were: mortality, stroke, permanent pacemaker implantation, New York Heart Association class and re-hospitalizations. Prosthetic valve performance evaluation comprised of: mean gradient, effective orifice area and paravalvular leak. RESULTS: Patients were elderly (82.8 ± 4.2 years) and predominantly female (n = 19, 70.4%). All of them were deemed to be at high surgical risk with a mean logistic EuroSCORE of 12.5 ± 6.7. The bioprosthesis was successfully implanted in 92.6% of the cases (n = 25). At 1-year, all-cause mortality was 12.0% (n = 3) and stroke was 4.0% (n = 1). Three (12%) of patients developed complete atrioventricular block and received permanent pacemakers. 84% of patients were in New York Heart Association class II or lower. Need for subsequent hospitalization arose in 48% patients. The echocardiographic assessment confirmed an acceptable hemodynamic profile of the Allegra with low mean transprosthetic gradient (9.5 ± 3.4 mmHg), absence of severe paravalvular leak and a 20%-presence of moderate paravalvular leak. CONCLUSIONS: The current follow-up observation study shows that the Allegra was associated with a satisfactory safety profile and hemodynamic performance at 1-year after implantation.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Diseño de Prótesis , Terfenadina/análogos & derivados , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
18.
Biology (Basel) ; 10(12)2021 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-34943265

RESUMEN

MiRNAs are noncoding, 21-24 nucleotide-long RNA particles that control over 60% of genes. MiRNAs affect gene expression through binding to the 3'-untranslated region of messenger RNA (mRNA), thus inhibiting mRNA translation or inducing mRNA degradation. MiRNAs have been associated with various cardiovascular diseases, including heart failure, hypertension, left ventricular hypertrophy, or ischemic heart disease. In addition, miRNA expression alters during coronary artery bypass grafting (CABG) surgery, which could be used to predict perioperative outcomes. CABG is an operation in which complex coronary arteries stenosis is treated by bypassing atherosclerotic lesions with venous or arterial grafts. Despite a very low perioperative mortality rate and excellent long-term survival, CABG is associated with postoperative complications, including reperfusion injury, graft failure, atrial fibrillation and perioperative myocardial infarction. So far, no reliable diagnostic and prognostic tools to predict prognosis after CABG have been developed. Changes in the perioperative miRNA expression levels could improve the diagnosis of post-CABG myocardial infarction and atrial fibrillation and could be used to stratify risk after CABG. Herein, we describe the expression changes of different subtypes of miRNAs during CABG and review the diagnostic and prognostic utility of miRNAs in patients undergoing CABG.

19.
Hypertens Res ; 43(7): 629-633, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32203452

RESUMEN

The purpose of this review was to discuss the role of sodium and inflammation in the pathophysiology of hypertension and the observed different hemodynamic effects of drugs. The Pathway-2 study revealed that similar reductions in vascular resistance after spironolactone and doxazosin resulted in opposite effects on sodium balance, water retention, and hemodynamic parameters. These and other clinical findings were bridged to recent experimental and physiological data. Tissue sodium accumulation in salt-sensitive individuals due to endothelial glycocalyx dysfunction causes macrophage infiltration, vascular inflammation, and local changes in angiotensin-2 and aldosterone concentrations. This inflammatory cascade leads to factor XII-related coagulation disorders with neutrophil extracellular trap formation (NETosis). This model of sodium-induced microcirculation impairment was used to explain the differences in central hemodynamic parameters after spironolactone or doxazosin treatment in resistant hypertension. Hypertension treatment by induced sodium removal or reduced sodium intake should reduce endothelial glycocalyx dysfunction, inflammation, NETosis, and coagulation disorders, leading to improved vascular health and cardiac diastolic function.


Asunto(s)
Hipertensión/fisiopatología , Inflamación/fisiopatología , Cloruro de Sodio Dietético/efectos adversos , Animales , Insuficiencia Cardíaca/fisiopatología , Humanos , Hipertensión/inducido químicamente , Inflamación/inducido químicamente
20.
Cardiol J ; 27(4): 394-403, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-30234900

RESUMEN

BACKGROUND: Red cell distribution width (RDW) in acute heart failure (AHF) is accepted as a prognostic indicator with unclear pathophysiological ties. The aim of this study was to evaluate the prognostic value of RDW in AHF patients in relation to clinical and echocardiographic data. METHODS: 170 patients with AHF were retrospectively studied. All patients had laboratory testing and an echocardiogram performed within 24 h of admission to the Cardiology Department. RESULTS: During the mean 193 ± 111 days of follow-up, 33 patients died. More advanced age, high RDW and low peak early diastolic velocity of the lateral mitral annulus (MVe') were independent predictors of all-cause mortality with hazard ratios of: 1.05 (95% CI 1.02-1.09), p < 0.005, 1.40 (95% CI 1.22-1.60), p < 0.001, and 0.77 (95% CI 0.63-0.93), p < 0.007, respectively. In a stepwise multiple linear regression model, RDW was correlated with hemoglobin concentration (standardized b = -0.233, p < 0.001), mean corpuscular volum (standardized b = -0.230, p < 0.001), mean corpuscular hemoglobin concentration (standardized b = -0.207, p < 0.007), the natural logarithm of C-reactive protein (CRP) (standardized b = 0.184, p < 0.004) and tricuspid regurgitation peak gradient (TRPG) values (standardized b = 0.179, p < 0.006), whereas MVe' was correlated with atrial fibrillation (standardized b = 0.269, p < 0.001). CONCLUSIONS: The present data demonstrates a novel relation between higher levels of RDW and elevated TRPG and high sensitivity CRP values in patients with AHF. These findings suggest that RDW, the most important mortality predictor, is independently associated with elevated pulmonary pressure and systemic inflammation in patients with AHF. Moreover, in AHF patients, more advanced age and decreased MVe' are also independently associated with total mortality risk.


Asunto(s)
Índices de Eritrocitos , Insuficiencia Cardíaca , Insuficiencia Cardíaca/diagnóstico , Humanos , Inflamación , Pronóstico , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA