1.
J Clin Monit Comput ; 37(2): 389-398, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35920951

RESUMEN

Clinical measurements offer bedside monitoring aiming to minimise unintended over-distension, but have limitations and cannot be predicted for changes in mechanical ventilation (MV) settings and are only available in certain MV modes. This study introduces a non-invasive, real-time over-distension measurement, which is robust, predictable, and more intuitive than current methods. The proposed over-distension measurement, denoted as OD, is compared with the clinically proven stress index (SI). Correlation is analysed via R2 and Spearman rs. The OD safe range corresponding to the unit-less SI safe range (0.95-1.05) is calibrated by sensitivity and specificity test. Validation is fulfilled with 19 acute respiratory distress syndrome (ARDS) patients data (196 cases), including assessment across ARDS severity. Overall correlation between OD and SI yielded R2 = 0.76 and Spearman rs = 0.89. Correlation is higher considering only moderate and severe ARDS patients. Calibration of OD to SI yields a safe range defined: 0 ≤ OD ≤ 0.8 cmH2O. The proposed OD offers an efficient, general, real-time measurement of patient-specific lung mechanics, which is more intuitive and robust than SI. OD eliminates the limitations of SI in MV mode and its less intuitive lung status value. Finally, OD can be accurately predicted for new ventilator settings via its foundation in a validated predictive personalized lung mechanics model. Therefore, OD offers potential clinical value over current clinical methods.


Asunto(s)
Respiración con Presión Positiva , Síndrome de Dificultad Respiratoria , Humanos , Respiración con Presión Positiva/métodos , Respiración Artificial/métodos , Pulmón , Síndrome de Dificultad Respiratoria/terapia , Ventiladores Mecánicos , Mecánica Respiratoria
2.
Biomed Eng Online ; 21(1): 16, 2022 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-35255922

RESUMEN

BACKGROUND: Patient-specific lung mechanics during mechanical ventilation (MV) can be identified from measured waveforms of fully ventilated, sedated patients. However, asynchrony due to spontaneous breathing (SB) effort can be common, altering these waveforms and reducing the accuracy of identified, model-based, and patient-specific lung mechanics. METHODS: Changes in patient-specific lung elastance over a pressure-volume (PV) loop, identified using hysteresis loop analysis (HLA), are used to detect the occurrence of asynchrony and identify its type and pattern. The identified HLA parameters are then combined with a nonlinear mechanics hysteresis loop model (HLM) to extract and reconstruct ventilated waveforms unaffected by asynchronous breaths. Asynchrony magnitude can then be quantified using an energy-dissipation metric, Easyn, comparing PV loop area between model-reconstructed and original, altered asynchronous breathing cycles. Performance is evaluated using both test-lung experimental data with a known ground truth and clinical data from four patients with varying levels of asynchrony. RESULTS: Root mean square errors for reconstructed PV loops are within 5% for test-lung experimental data, and 10% for over 90% of clinical data. Easyn clearly matches known asynchrony magnitude for experimental data with RMS errors < 4.1%. Clinical data performance shows 57% breaths having Easyn > 50% for Patient 1 and 13% for Patient 2. Patient 3 only presents 20% breaths with Easyn > 10%. Patient 4 has Easyn = 0 for 96% breaths showing accuracy in a case without asynchrony. CONCLUSIONS: Experimental test-lung validation demonstrates the method's reconstruction accuracy and generality in controlled scenarios. Clinical validation matches direct observations of asynchrony in incidence and quantifies magnitude, including cases without asynchrony, validating its robustness and potential efficacy as a clinical real-time asynchrony monitoring tool.


Asunto(s)
Respiración Artificial , Mecánica Respiratoria , Humanos , Modelos Biológicos , Dinámicas no Lineales , Pruebas de Función Respiratoria , Mecánica Respiratoria/fisiología
3.
Physiology (Bethesda) ; 34(6): 419-429, 2019 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-31577170

RESUMEN

Despite a huge range in lung size between species, there is little measured difference in the ability of the lung to provide a well-matched air flow (ventilation) to blood flow (perfusion) at the gas exchange tissue. Here, we consider the remarkable similarities in ventilation/perfusion matching between species through a biophysical lens and consider evidence that matching in large animals is dominated by gravity but in small animals by structure.


Asunto(s)
Pulmón/fisiología , Animales , Gravitación , Humanos , Ratones , Fenómenos Fisiológicos/fisiología , Flujo Sanguíneo Regional/fisiología , Respiración
4.
Crit Care Med ; 48(1): e66-e73, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31634232

RESUMEN

OBJECTIVES: The theoretical basis for minimizing tidal volume during high-frequency oscillatory ventilation may not be appropriate when lung tissue stretch occurs heterogeneously and/or rapidly. The objective of this study was to assess the extent to which increased ventilation heterogeneity may contribute to ventilator-induced lung injury during high-frequency oscillatory ventilation in adults compared with neonates on the basis of lung size, using a computational model of human lungs. DESIGN: Computational modeling study. SETTING: Research laboratory. SUBJECTS: High-fidelity, 3D computational models of human lungs, scaled to various sizes representative of neonates, children, and adults, with varying injury severity. All models were generated from one thoracic CT image of a healthy adult male. INTERVENTIONS: Oscillatory ventilation was simulated in each lung model at frequencies ranging from 0.2 to 40 Hz. Sinusoidal flow oscillations were delivered at the airway opening of each model and distributed through the lungs according to regional parenchymal mechanics. MEASUREMENTS AND MAIN RESULTS: Acinar flow heterogeneity was assessed by the coefficient of variation in flow magnitudes across all acini in each model. High-frequency oscillatory ventilation simulations demonstrated increasing heterogeneity of regional parenchymal flow with increasing lung size, with decreasing ratio of deadspace to total acinar volume, and with increasing frequency above lung corner frequency and resonant frequency. Potential for resonant amplification was greatest in injured adult-sized lungs with higher regional quality factors indicating the presence of underdamped lung regions. CONCLUSIONS: The potential for ventilator-induced lung injury during high-frequency oscillatory ventilation is enhanced at frequencies above lung corner frequency or resonant frequency despite reduced tidal volumes, especially in adults, due to regional amplification of heterogeneous flow. Measurements of corner frequency and resonant frequency should be considered during high-frequency oscillatory ventilation management.


Asunto(s)
Ventilación de Alta Frecuencia/efectos adversos , Pulmón/anatomía & histología , Lesión Pulmonar Inducida por Ventilación Mecánica/etiología , Adulto , Niño , Simulación por Computador , Humanos , Recién Nacido , Tamaño de los Órganos
5.
J Biomech Eng ; 139(5)2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28267189

RESUMEN

Spiral arteries (SAs) lie at the interface between the uterus and placenta, and supply nutrients to the placental surface. Maternal blood circulation is separated from the fetal circulation by structures called villous trees. SAs are transformed in early pregnancy from tightly coiled vessels to large high-capacity channels, which is believed to facilitate an increased maternal blood flow throughout pregnancy with minimal increase in velocity, preventing damage to delicate villous trees. Significant maternal blood flow velocities have been theorized in the space surrounding the villi (the intervillous space, IVS), particularly when SA conversion is inadequate, but have only recently been visualized reliably using pulsed wave Doppler ultrasonography. Here, we present a computational model of blood flow from SA openings, allowing prediction of IVS properties based on jet length. We show that jets of flow observed by ultrasound are likely correlated with increased IVS porosity near the SA mouth and propose that observed mega-jets (flow penetrating more than half the placental thickness) are only possible when SAs open to regions of the placenta with very sparse villous structures. We postulate that IVS tissue density must decrease at the SA mouth through gestation, supporting the hypothesis that blood flow from SAs influences villous tree development.


Asunto(s)
Circulación Sanguínea , Vellosidades Coriónicas/irrigación sanguínea , Modelos Biológicos , Arterias/fisiología , Vellosidades Coriónicas/metabolismo , Femenino , Humanos , Hidrodinámica , Madres , Embarazo
6.
J Theor Biol ; 408: 1-12, 2016 11 07.
Artículo en Inglés | MEDLINE | ID: mdl-27378004

RESUMEN

The placenta is critical to fetal health during pregnancy as it supplies oxygen and nutrients to maintain life. It has a complex structure, and alterations to this structure across spatial scales are associated with several pregnancy complications, including intrauterine growth restriction (IUGR). The relationship between placental structure and its efficiency as an oxygen exchanger is not well understood in normal or pathological pregnancies. Here we present a computational framework that predicts oxygen transport in the placenta which accounts for blood and oxygen transport in the space around a placental functional unit (the villous tree). The model includes the well-defined branching structure of the largest villous tree branches, as well as a smoothed representation of the small terminal villi that comprise the placenta's gas exchange interfaces. The model demonstrates that oxygen exchange is sensitive to villous tree geometry, including the villous branch length and volume, which are seen to change in IUGR. This is because, to be an efficient exchanger, the architecture of the villous tree must provide a balance between maximising the surface area available for exchange, and the opposing condition of allowing sufficient maternal blood flow to penetrate into the space surrounding the tree. The model also predicts an optimum oxygen exchange when the branch angle is 24 °, as villous branches and TBs are spread out sufficiently to channel maternal blood flow deep into the placental tissue for oxygen exchange without being shunted directly into the DVs. Without concurrent change in the branch length and angles, the model predicts that the number of branching generations has a small influence on oxygen exchange. The modelling framework is presented in 2D for simplicity but is extendible to 3D or to incorporate the high-resolution imaging data that is currently evolving to better quantify placental structure.


Asunto(s)
Vellosidades Coriónicas/anatomía & histología , Vellosidades Coriónicas/metabolismo , Intercambio Materno-Fetal/fisiología , Oxígeno/metabolismo , Placenta/metabolismo , Animales , Vellosidades Coriónicas/irrigación sanguínea , Femenino , Humanos , Mamíferos , Modelos Biológicos , Placenta/anatomía & histología , Placenta/irrigación sanguínea , Embarazo
7.
J Biomech Eng ; 138(6): 061008, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27109169

RESUMEN

One limitation of forced spirometry is that it integrates the contribution of the complex and dynamic behavior of all of the airways and tissue of the lung into a single exhaling unit, hence, it is not clear how spirometric measures are affected by local changes to the airways or tissue such as the presence of "ventilation defects." Here, we adapt a wave-speed limitation model to a spatially distributed and anatomically based airway tree that is embedded within a deformable parenchyma, to simulate forced expiration in 1 s (FEV1). This provides a model that can be used to assess the consequence of imposed constrictions on FEV1. We first show how the model can be parameterized to represent imaging and forced spirometry data from nonasthmatic healthy young adults. We then compare the effect of homogeneous and clustered bronchoconstriction on FEV1 in six subject-specific models (three male and three female). The model highlights potential sources of normal subject variability in response to agonist challenge, including the interaction between sites of airway constriction and sites of flow limitation at baseline. The results support earlier studies which proposed that the significant constriction of nondefect airways must be present in order to match to clinical measurements of lung function.


Asunto(s)
Fenómenos Biofísicos , Broncoconstricción , Flujo Espiratorio Forzado , Modelos Biológicos , Femenino , Análisis de Elementos Finitos , Humanos , Masculino , Modelación Específica para el Paciente
8.
J Biomech Eng ; 137(5): 051010, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25727935

RESUMEN

Previous studies of the ex vivo lung have suggested significant intersubject variability in lung lobe geometry. A quantitative description of normal lung lobe shape would therefore have value in improving the discrimination between normal population variability in shape and pathology. To quantify normal human lobe shape variability, a principal component analysis (PCA) was performed on high resolution computed tomography (HRCT) imaging of the lung at full inspiration. Volumetric imaging from 22 never-smoking subjects (10 female and 12 male) with normal lung function was included in the analysis. For each subject, an initial finite element mesh geometry was generated from a group of manually selected nodes that were placed at distinct anatomical locations on the lung surface. Each mesh used cubic shape functions to describe the surface curvilinearity, and the mesh was fitted to surface data for each lobe. A PCA was performed on the surface meshes for each lobe. Nine principal components (PCs) were sufficient to capture >90% of the normal variation in each of the five lobes. The analysis shows that lobe size can explain between 20% and 50% of intersubject variability, depending on the lobe considered. Diaphragm shape was the next most significant intersubject difference. When the influence of lung size difference is removed, the angle of the fissures becomes the most significant shape difference, and the variability in relative lobe size becomes important. We also show how a lobe from an independent subject can be projected onto the study population's PCs, demonstrating potential for abnormalities in lobar geometry to be defined in a quantitative manner.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Pulmón/anatomía & histología , Pulmón/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Análisis de Componente Principal , Reproducibilidad de los Resultados
9.
Artículo en Inglés | MEDLINE | ID: mdl-26744596

RESUMEN

Understanding and treatment of asthma is significantly complicated by the heterogeneous spectrum of phenotypes associated with the disease. Recent advances in phenotype classification promise more targeted therapies, but these categories are based on constellations of largely external measurements and are not necessarily indicative of underlying pathophysiology. We propose that computational modelling is a valuable tool that allows the disease spectrum to be decomposed not into phenotypes but rather into groups organized by underlying dysfunction, referred to by some authors as endotypes. By breaking down the asthmatic spectrum in this way, therapies can be targeted more directly to the underlying defects. This would be not only an important improvement in its own right, but also an important step toward the ultimate goal of patient-specific modelling.

10.
Sci Rep ; 14(1): 2115, 2024 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-38267531

RESUMEN

Electrical impedance tomography (EIT) is an imaging method that can be used to image electrical impedance contrasts within various tissues of the body. To support development of EIT measurement systems, a phantom is required that represents the electrical characteristics of the imaging domain. No existing type of EIT phantom combines good performance in all three characteristics of resistivity resolution, spatial resolution, and stability. Here, a novel EIT phantom concept is proposed that uses 3D printed conductive material. Resistivity is controlled using the 3D printing infill percentage parameter, allowing arbitrary resistivity contrasts within the domain to be manufactured automatically. The concept of controlling resistivity through infill percentage is validated, and the manufacturing accuracy is quantified. A method for making electrical connections to the 3D printed material is developed. Finally, a prototype phantom is printed, and a sample EIT analysis is performed. The resulting phantom, printed with an Ultimaker S3, has high reported spatial resolution of 6.9 µm, 6.9 µm, and 2.5 µm for X, Y, and Z axis directions, respectively (X and Y being the horizontal axes, and Z the vertical). The number of resistivity levels that are manufacturable by varying infill percentage is 15 (calculated by dividing the available range of resistivities by two times the standard deviation of the manufacturing accuracy). This phantom construction technique will allow assessment of the performance of EIT devices under realistic physiological scenarios.

11.
HardwareX ; 18: e00521, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38549955

RESUMEN

Electrical impedance tomography (EIT) is medical imaging technique in which small electrical signals are used to map the electrical impedance distribution within the body. It is safe and non-invasive, which make it attractive for use in continuous monitoring or outpatient applications, but the high cost of commercial devices is an impediment to its adoption. Over the last 10 years, many research groups have developed their own EIT devices, but few designs for open-source EIT hardware are available. In this work, we present a complete open-source EIT system that is designed to be suitable for monitoring the lungs of free breathing subjects. The device is low-cost, wearable, and is designed to comply with the industry accepted safety standard for EIT. The device has been tested in two regimes: Firstly in terms of measurement uncertainty as a voltage measurement system, and secondly against a set of measures that have been proposed specifically for EIT hardware. The voltage measurement uncertainty of the device was measured to be - 0.7 % ± 0.36 mV. The EIT specific performance was measured in a phantom test designed to be as physiologically representative as practicable, and the device performed similarly to other published devices. This work will contribute to increased accessibility of EIT for study and will contribute to consensus on testing methodology for EIT devices.

12.
Acad Radiol ; 31(4): 1676-1685, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37758587

RESUMEN

RATIONALE AND OBJECTIVES: Idiopathic Pulmonary Fibrosis (IPF) is a progressive interstitial lung disease characterised by heterogeneously distributed fibrotic lesions. The inter- and intra-patient heterogeneity of the disease has meant that useful biomarkers of severity and progression have been elusive. Previous quantitative computed tomography (CT) based studies have focussed on characterising the pathological tissue. However, we hypothesised that the remaining lung tissue, which appears radiologically normal, may show important differences from controls in tissue characteristics. MATERIALS AND METHODS: Quantitative metrics were derived from CT scans in IPF patients (N = 20) and healthy controls with a similar age (N = 59). An automated quantitative software (CALIPER, Computer-Aided Lung Informatics for Pathology Evaluation and Rating) was used to classify tissue as normal-appearing, fibrosis, or low attenuation area. Densitometry metrics were calculated for all lung tissue and for only the normal-appearing tissue. Heterogeneity of lung tissue density was quantified as coefficient of variation and by quadtree. Associations between measured lung function and quantitative metrics were assessed and compared between the two cohorts. RESULTS: All metrics were significantly different between controls and IPF (p < 0.05), including when only the normal tissue was evaluated (p < 0.04). Density in the normal tissue was 14% higher in the IPF participants than controls (p < 0.001). The normal-appearing tissue in IPF had heterogeneity metrics that exhibited significant positive relationships with the percent predicted diffusion capacity for carbon monoxide. CONCLUSION: We provide quantitative assessment of IPF lung tissue characteristics compared to a healthy control group of similar age. Tissue that appears visually normal in IPF exhibits subtle but quantifiable differences that are associated with lung function and gas exchange.


Asunto(s)
Fibrosis Pulmonar Idiopática , Enfermedades Pulmonares Intersticiales , Humanos , Fibrosis Pulmonar Idiopática/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Pulmón/patología , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Biomarcadores , Estudios Retrospectivos
13.
Comput Methods Programs Biomed ; 244: 107988, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38171168

RESUMEN

BACKGROUND AND OBJECTIVE: Recruitment maneuvers with subsequent positive-end-expiratory-pressure (PEEP) have proven effective in recruiting lung volume and preventing alveoli collapse. However, determining a safe, effective, and patient-specific PEEP is not standardized, and this more optimal PEEP level evolves with patient condition, requiring personalised monitoring and care approaches to maintain optimal ventilation settings. METHODS: This research examines 3 physiologically relevant basis function sets (exponential, parabolic, cumulative) to enable better prediction of elastance evolution for a virtual patient or digital twin model of MV lung mechanics, including novel elements to model and predict distension elastance. Prediction accuracy and robustness are validated against recruitment maneuver data from 18 volume-controlled ventilation (VCV) patients at 7 different baseline PEEP levels (0 to 12 cmH2O) and 14 pressure-controlled ventilation (PCV) patients at 4 different baseline PEEP levels (6 to 12 cmH2O), yielding 623 and 294 prediction cases, respectively. Predictions were made up to 12 cmH2O of added PEEP ahead, covering 6 × 2 cmH2O PEEP steps. RESULTS: The 3 basis function sets yield median absolute peak inspiratory pressure (PIP) prediction error of 1.63 cmH2O for VCV patients, and median peak inspiratory volume (PIV) prediction error of 0.028 L for PCV patients. The exponential basis function set yields a better trade-off of overall performance across VCV and PCV prediction than parabolic and cumulative basis function sets from other studies. Comparing predicted and clinically measured distension prediction in VCV demonstrated consistent, robust high accuracy with R2 = 0.90-0.95. CONCLUSIONS: The results demonstrate recruitment mechanics are best captured by an exponential basis function across different mechanical ventilation modes, matching physiological expectations, and accurately capture, for the first time, distension mechanics to within 5-10 % accuracy. Enabling the risk of lung injury to be predicted before changing ventilator settings. The overall outcomes significantly extend and more fully validate this digital twin or virtual mechanical ventilation patient model.


Asunto(s)
Pulmón , Mecánica Respiratoria , Humanos , Mecánica Respiratoria/fisiología , Respiración Artificial/métodos , Respiración con Presión Positiva/métodos , Respiración
14.
Acad Radiol ; 2024 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-38679527

RESUMEN

RATIONALE AND OBJECTIVES: Fibrotic scarring in idiopathic pulmonary fibrosis (IPF) typically develops first in the posterior-basal lung tissue before advancing to involve more of the lung. The complexity of lung shape in the costo-diaphragmatic region has been proposed as a potential factor in this regional development. Intrinsic and disease-related shape could therefore be important for understanding IPF risk and its staging. We hypothesized that lung and lobe shape in IPF would have important differences from controls. MATERIALS AND METHODS: A principal component (PC) analysis was used to derive a statistical shape model (SSM) of the lung for a control cohort aged > 50 years (N = 39), using segmented lung and fissure surface data from CT imaging. Individual patient shape models derived for baseline (N = 18) and follow-up (N = 16) CT scans in patients with IPF were projected to the SSM to describe shape as the sum of the SSM average and weighted PC modes. Associations between the first four PC shape modes, lung function, percentage of fibrosis (fibrosis%) and pulmonary vessel-related structures (PVRS%), and other tissue metrics were assessed and compared between the two cohorts. RESULTS: Shape was different between IPF and controls (P < 0.05 for all shape modes), with IPF shape forming a distinct shape cluster. Shape had a negative relationship with age in controls (P = 0.013), but a positive relationship with age in IPF (P = 0.026). Some features of shape changed on follow-up. Shape in IPF was associated with fibrosis% (P < 0.05) and PVRS% (P < 0.05). CONCLUSION: Quantitative comparison of lung and lobe shape in IPF with controls of a similar age reveals shape differences that are strongly associated with age and percent fibrosis. The clustering of IPF cohort shape suggests that it could be an important feature to describe disease.

15.
IEEE Trans Biomed Eng ; 70(8): 2486-2495, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37028024

RESUMEN

OBJECTIVE: electrical impedance tomography (EIT) is a promising technique for rapid and continuous bedside monitoring of lung function. Accurate and reliable EIT reconstruction of ventilation requires patient-specific shape information. However, this shape information is often not available and current EIT reconstruction methods typically have limited spatial fidelity. This study sought to develop a statistical shape model (SSM) of the torso and lungs and evaluate whether patient-specific predictions of torso and lung shape could enhance EIT reconstructions in a Bayesian framework. METHODS: torso and lung finite element surface meshes were fitted to computed tomography data from 81 participants, and a SSM was generated using principal component analysis and regression analyses. Predicted shapes were implemented in a Bayesian EIT framework and were quantitatively compared to generic reconstruction methods. RESULTS: Five principal shape modes explained 38% of the cohort variance in lung and torso geometry, and regression analysis yielded nine total anthropometrics and pulmonary function metrics that significantly predicted these shape modes. Incorporation of SSM-derived structural information enhanced the accuracy and reliability of the EIT reconstruction as compared to generic reconstructions, demonstrated by reduced relative error, total variation, and Mahalanobis distance. CONCLUSION: As compared to deterministic approaches, Bayesian EIT afforded more reliable quantitative and visual interpretation of the reconstructed ventilation distribution. However, no conclusive improvement of reconstruction performance using patient specific structural information was observed as compared to the mean shape of the SSM. SIGNIFICANCE: The presented Bayesian framework builds towards a more accurate and reliable method for ventilation monitoring via EIT.


Asunto(s)
Tomografía Computarizada por Rayos X , Tomografía , Humanos , Tomografía/métodos , Teorema de Bayes , Impedancia Eléctrica , Reproducibilidad de los Resultados
16.
Mil Med ; 188(Suppl 6): 141-148, 2023 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-37948236

RESUMEN

INTRODUCTION: During mechanical ventilation, cyclic recruitment and derecruitment (R/D) of alveoli result in focal points of heterogeneous stress throughout the lung. In the acutely injured lung, the rates at which alveoli can be recruited or derecruited may also be altered, requiring longer times at higher pressure levels to be recruited during inspiration, but shorter times at lower pressure levels to minimize collapse during exhalation. In this study, we used a computational model to simulate the effects of airway pressure release ventilation (APRV) on acinar recruitment, with varying inspiratory pressure levels and durations of exhalation. MATERIALS AND METHODS: The computational model consisted of a ventilator pressure source, a distensible breathing circuit, an endotracheal tube, and a porcine lung consisting of recruited and derecruited zones, as well as a transitional zone capable of intratidal R/D. Lung injury was simulated by modifying each acinus with an inflation-dependent surface tension. APRV was simulated for an inhalation duration (Thigh) of 4.0 seconds, inspiratory pressures (Phigh) of 28 and 40 cmH2O, and exhalation durations (Tlow) ranging from 0.2 to 1.5 seconds. RESULTS: Both sustained acinar recruitment and intratidal R/D within the subtree were consistently higher for Phigh of 40 cmH2O vs. 28 cmH2O, regardless of Tlow. Increasing Tlow was associated with decreasing sustained acinar recruitment, but increasing intratidal R/D, within the subtree. Increasing Tlow was associated with decreasing elastance of both the total respiratory system and transitional subtree of the model. CONCLUSIONS: Our computational model demonstrates the confounding effects of cyclic R/D, sustained recruitment, and parenchymal strain stiffening on estimates of total lung elastance during APRV. Increasing inspiratory pressures leads to not only more sustained recruitment of unstable acini but also more intratidal R/D. Our model indicates that higher inspiratory pressures should be used in conjunction with shorter exhalation times, to avoid increasing intratidal R/D.


Asunto(s)
Presión de las Vías Aéreas Positiva Contínua , Pulmón , Animales , Porcinos , Respiración Artificial/efectos adversos , Rendimiento Pulmonar , Simulación por Computador
17.
Sci Rep ; 13(1): 4422, 2023 03 17.
Artículo en Inglés | MEDLINE | ID: mdl-36932117

RESUMEN

Idiopathic pulmonary fibrosis (IPF) is characterised by progressive fibrosing interstitial pneumonia with an associated irreversible decline in lung function and quality of life. IPF prevalence increases with age, appearing most frequently in patients aged > 50 years. Pulmonary vessel-like volume (PVV) has been found to be an independent predictor of mortality in IPF and other interstitial lung diseases, however its estimation can be impacted by artefacts associated with image segmentation methods and can be confounded by adjacent fibrosis. This study compares PVV in IPF patients (N = 21) with PVV from a healthy cohort aged > 50 years (N = 59). The analysis includes a connected graph-based approach that aims to minimise artefacts contributing to calculation of PVV. We show that despite a relatively low extent of fibrosis in the IPF cohort (20% of the lung volume), PVV is 2-3 times higher than in controls. This suggests that a standardised method to calculate PVV that accounts for tree connectivity could provide a promising tool to provide early diagnostic or prognostic information in IPF patients and other interstitial lung disease.


Asunto(s)
Fibrosis Pulmonar Idiopática , Enfermedades Pulmonares Intersticiales , Humanos , Persona de Mediana Edad , Calidad de Vida , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Pronóstico , Fibrosis
18.
Front Physiol ; 14: 1104838, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36969588

RESUMEN

Our study methodology is motivated from three disparate needs: one, imaging studies have existed in silo and study organs but not across organ systems; two, there are gaps in our understanding of paediatric structure and function; three, lack of representative data in New Zealand. Our research aims to address these issues in part, through the combination of magnetic resonance imaging, advanced image processing algorithms and computational modelling. Our study demonstrated the need to take an organ-system approach and scan multiple organs on the same child. We have pilot tested an imaging protocol to be minimally disruptive to the children and demonstrated state-of-the-art image processing and personalized computational models using the imaging data. Our imaging protocol spans brain, lungs, heart, muscle, bones, abdominal and vascular systems. Our initial set of results demonstrated child-specific measurements on one dataset. This work is novel and interesting as we have run multiple computational physiology workflows to generate personalized computational models. Our proposed work is the first step towards achieving the integration of imaging and modelling improving our understanding of the human body in paediatric health and disease.

19.
Neuroimage ; 62(1): 482-92, 2012 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-22587899

RESUMEN

Variations in local neural activity are accompanied by rapid, focal changes in cerebral blood flow and volume. While a range of observations have shown that dilation occurs in cerebral arteries, there is conflicting evidence about the significance of volume changes in post-arteriole vessels. Here, we reconcile the competing observations using a new mathematical model of the hemodynamic response. First, we followed a 'top down' approach, without constraining the model, but using experimental observations at progressively more detailed scales to ensure physiological behaviour. Then, we blocked dilation of post-arteriole vessels, and predicted observations at progressively more aggregated scales (a 'bottom up' approach). Predictions of blood flow, volume, velocity, and vessel diameter changes were consistent with experimental observations. Interestingly, the model predicted small, slow increases in capillary and venous diameter in agreement with recent in vivo data. Blocking dilation in these vessels led to erroneous volume predictions. The results are further evidence that arteries make up the majority of blood volume increases during brief functional activation. However, dilation of capillaries and veins appears to be increasingly significant during extended stimulation. These are important considerations when interpreting results from different neurovascular imaging modalities.


Asunto(s)
Volumen Sanguíneo , Encéfalo/fisiopatología , Arterias Cerebrales/fisiopatología , Hiperemia/fisiopatología , Modelos Cardiovasculares , Modelos Neurológicos , Simulación por Computador , Medicina Basada en la Evidencia , Humanos
20.
J Theor Biol ; 300: 222-31, 2012 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-22326472

RESUMEN

The topographic distribution of ventilation in the lungs is determined by the interaction of several factors, including lung shape, airway tree geometry, posture, and tissue deformation. Inter-species differences in lung structure-function and technical difficulty in obtaining high resolution imaging of the upright human lung means that it is not straightforward to experimentally determine the contribution of each of these factors to ventilation distribution. We present a mathematical model for predicting the topological distribution of inhaled air in the upright healthy human lung, based on anatomically structured model geometries and biophysical equations for model function. Gravitational deformation of the lung tissue is predicted using a continuum model. Airflow is simulated in anatomically based conducting airways coupled to geometrically simplified terminal acinar units with varying volume-dependent compliances. The predicted ventilation distribution is hence governed by local tissue density and elastic recoil pressure, airway resistance and acinar compliance. Results suggest that there is significant spatial variation in intrinsic tissue properties in the lungs. The model confirms experimental evidence that in the healthy lungs tissue compliance has a far greater effect than airway resistance on the spatial distribution of ventilation, and hence a realistic description of tissue deformation is essential in models of ventilation.


Asunto(s)
Modelos Biológicos , Ventilación Pulmonar/fisiología , Células Acinares/fisiología , Resistencia de las Vías Respiratorias/fisiología , Humanos , Pulmón/anatomía & histología , Rendimiento Pulmonar/fisiología , Postura/fisiología
SELECCIÓN DE REFERENCIAS