Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Radiother Oncol ; 180: 109484, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36690303

RESUMEN

BACKGROUND AND PURPOSE: In cancer treatment precise definition of the tumor volume is essential, but despite development in imaging modalities, this remains a challenge. Here, pathological tumor volumes from the surgical specimens were obtained and compared to tumor volumes defined from modern PET/MRI hybrid imaging. The purpose is to evaluate mismatch between the volumes defined from imaging and pathology was estimated and potential clinical impact. METHODS AND MATERIALS: Twenty-five patients with head and neck squamous cell carcinoma were scanned on an integrated PET/MRI system prior to surgery. Three gross tumor volumes (GTVs) from the primary tumor site were delineated defined from MRI (GTVMRI), PET (GTVPET) and one by utilizing both anatomical images and clinical information (GTVONCO). Twenty-five primary tumor specimens were extracted en bloc, scanned with PET/MRI and co-registered to the patient images. Each specimen was sectioned in blocks, sliced and stained with haematoxylin and eosin. All slices were digitalized and tumor delineated by a head and neck pathologist. The pathological tumor areas in all slices were interpolated yielding a pathological 3D tumor volume (GTVPATO). GTVPATOwas compared with the imaging GTV's and potential mismatch was estimated. RESULTS: Thirteen patients were included. The mean volume of GTVONCOwas larger than the GTV's defined from PET or MRI. The mean mismatch of the GTVPATOcompared to the GTVPET, GTVMRIand GTVONCOwas 31.9 %, 54.5 % and 27.9 % respectively, and the entire GTVPATO was only fully encompassed in GTVONCO in 1 of 13 patients. However, after the addition of a clinical 5 mm margin the GTVPATO was fully encompassed in GTVONCO in 11 out of 13 patients. CONCLUSIONS: Despite modern hybrid imaging modalities, a mismatch between imaging and pathological defined tumor volumes was observed in all patients.A 5 mm clinical margin was sufficient to ensure inclusion of the entire pathological volume in 11 out of 13 patients.


Asunto(s)
Neoplasias de Cabeza y Cuello , Tomografía Computarizada por Rayos X , Humanos , Carcinoma de Células Escamosas de Cabeza y Cuello/diagnóstico por imagen , Carga Tumoral , Tomografía Computarizada por Rayos X/métodos , Tomografía de Emisión de Positrones/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Radiofármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA