Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Membranes (Basel) ; 14(4)2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38668111

RESUMEN

While efficient removal of uremic toxins and accumulated water is pivotal for the well-being of dialysis patients, protein adsorption to the dialyzer membrane reduces the performance of a dialyzer. Hydrophilic membrane modification with polyvinylpyrrolidone (PVP) has been shown to reduce protein adsorption and to stabilize membrane permeability. In this study we compared middle molecule clearance and filtration performance of nine polysulfone-, polyethersulfone-, and cellulose-based dialyzers over time. Protein adsorption was simulated in recirculation experiments, while ß2-microglobulin clearance as well as transmembrane pressure (TMP) and filtrate flow were determined over time. The results of this study showed that ß2-microglobulin clearance (-7.2 mL/min/m2) and filtrate flow (-54.4 mL/min) decreased strongly during the first 30 min and slowly afterwards (-0.7 mL/min/m2 and -6.8 mL/min, respectively, for the next 30 min); the TMP increase (+37.2 mmHg and +8.6 mmHg, respectively) showed comparable kinetics. Across all tested dialyzers, the dialyzer with a hydrophilic modified membrane (FX CorAL) had the highest ß2-microglobulin clearance after protein fouling and the most stable filtration characteristics. In conclusion, hydrophilic membrane modification with PVP stabilizes the removal capacity of middle molecules and filtration performance over time. Such dialyzers may have benefits during hemodiafiltration treatments which aim to achieve high exchange volumes.

2.
Bioengineering (Basel) ; 10(2)2023 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-36829639

RESUMEN

Despite the significant medical and technical improvements in the field of dialytic renal replacement modalities, morbidity and mortality are excessively high among patients with end-stage kidney disease, and most interventional studies yielded disappointing results. Hemodiafiltration, a dialysis method that was implemented in clinics many years ago and that combines the two main principles of hemodialysis and hemofiltration-diffusion and convection-has had a positive impact on mortality rates, especially when delivered in a high-volume mode as a surrogate for a high convective dose. The achievement of high substitution volumes during dialysis treatments does not only depend on patient characteristics but also on the dialyzer (membrane) and the adequately equipped hemodiafiltration machine. The present review article summarizes the technical aspects of online hemodiafiltration and discusses present and ongoing clinical studies with regards to hard clinical and patient-reported outcomes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA