Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Interact Cardiovasc Thorac Surg ; 30(3): 400-407, 2020 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-31778163

RESUMEN

OBJECTIVES: Transcatheter aortic valve implantation with a transaortic approach (TAo-TAVI) is an alternative to transapical or femoral access. We studied the procedural and midterm efficacy and safety of TAo-TAVI with Edwards Sapien XT and Medtronic CoreValve devices. METHODS: Among 901 patients receiving TAVI since 2006, 265 consecutive patients underwent TAo-TAVI between January 2011 and September 2014. Procedural and midterm results were evaluated according to Valve Academic Research Consortium-2 criteria. RESULTS: The mean age was 83 ± 5 years. Sapien XT and CoreValve were used in 191 (72.1%) and 74 (27.9%) patients, respectively. Full sternotomy made elective concomitant off-pump coronary artery bypass grafting possible in 38 patients (14.3%) with severe coronary artery disease unsuitable for percutaneous coronary intervention. The device success rate was 95.5%. Postprocedural paravalvular leak ≥2/4 was observed in 16 patients (6.4%). Emergency open chest surgery was required in 10 patients (3.8%) (3 aortic dissections, 3 valve embolizations, 2 LMCA occlusions, 1 aortic annulus rupture and 1 aortic rupture). Cerebrovascular accidents occurred in 3 patients (1.1%). Transfusions ≥4 units were required in 36 patients (13.6%). New pacemakers were implanted in 26 patients (9.8%). Thirty-day and 1-year mortality were 8.7% and 16.2%, respectively. Mean follow-up duration was 24 ± 6 months. At 3 years, freedom from all-cause death was 80% ± 4%. New York Heart Association class

Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estudios de Cohortes , Puente de Arteria Coronaria Off-Pump , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Ecocardiografía , Femenino , Prótesis Valvulares Cardíacas , Humanos , Masculino , Esternotomía , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento
2.
J Thorac Cardiovasc Surg ; 130(1): 13-9, 2005 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15999035

RESUMEN

OBJECTIVE: A follow-up study was performed to assess long-term survival, valve-related complications, and pregnancy outcomes in young rheumatic women undergoing isolated mitral mechanical replacement. The influence of prosthetic type on outcomes was also investigated. METHODS: Between 1975 and 2003, 267 isolated mitral mechanical prostheses were implanted. Follow-up reached 3707.8 patient-years. RESULTS: Actuarial survival at 1, 5, 10, 15, 20, and 25 years was 97% +/- 0.01%, 90.4% +/- 0.017%, 85.3% +/- 0.023%, 82.3% +/- 0.025%, 71.7% +/- 0.036%, and 70.2% +/- 0.038%, respectively. At multivariate analysis, atrial fibrillation at follow-up was identified as an independent risk factor for late mortality, whereas left ventricular ejection fraction at 12 postoperative months proved to be a protective factor. Freedom from thromboembolism at 1, 5, 10, 15, 20, and 25 years was 98.1% +/- 0.01%, 94.1% +/- 0.015%, 89.1% +/- 0.021%, 85.9% +/- 0.025%, 81.1% +/- 0.031%, and 75.3% +/- 0.063%, respectively. Atrial fibrillation and Carbomedics device were significantly associated with an increase in thromboembolic events. Freedom from reoperation at 1, 5, 10, 15, 20, and 25 years was 99.2% +/- 0.005%, 95% +/- 0.014%, 91.6% +/- 0.018%, 88.6% +/- 0.022%, and 85.7% +/- 0.041%. Type of prosthesis (tilting disc) was identified as a predictor of reoperation. At the end of the study, 208 patients were still alive: 94.7% were in New York Heart Association class I or II. When receiving warfarin therapy, no patient undertaking pregnancy (n = 35) experienced adverse cardiac or valve-related events. Fetal events were significantly less frequent with a daily warfarin dose less than 5 mg. CONCLUSIONS: Mechanical devices provided excellent performance, safety, and durability. The prognostic role of left ventricular function and atrial fibrillation overwhelmed any differences that might exist between different prosthetic designs. Pregnancies entail virtually no maternal risk and predictable fetal complications.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Válvula Mitral , Resultado del Embarazo , Cardiopatía Reumática/cirugía , Adolescente , Adulto , Anticoagulantes/administración & dosificación , Femenino , Estudios de Seguimiento , Prótesis Valvulares Cardíacas , Humanos , Análisis Multivariante , Embarazo , Diseño de Prótesis , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Warfarina/administración & dosificación
3.
Int J Cardiol ; 113(3): 320-6, 2006 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-16413075

RESUMEN

BACKGROUND: Different anatomical forms of proximal aortic dilations associated with aortic valve disease can be distinguished by echocardiography. Differences in the anatomy could reflect different pathogeneses and need for different therapeutic approaches. The present study assessed the clinical features associated to each anatomical form, particularly focusing on the relations with valve morphology and function. METHODS: Trans-thoracic and trans-esophageal echocardiography reports of 552 adult patients (mean age 60.4+/-12.8 years; 379 male) with mild to severe proximal aorta dilation were reviewed. The relationships between the anatomy of aorta dilatation (distinguished into "root type" dilatation, with maximal enlargement at the sinuses, and "mid-ascending type", with maximal diameter at the mid-ascending tract) and aortic valve morphology (tricuspid/bicuspid) and function (normal/stenosis/regurgitation) were assessed. The relations with other clinico-echocardiographic variables were also tested in univariate and multivariate analysis. RESULTS: A "root type" dilatation was found in 4.9% tricuspid patients with stenosis, 32.3% with regurgitation, 22.5% with normal valve function (p=0.018). Dilatation prevailed at the mid-ascending tract in patients with bicuspid aortic valve, irrespective of valve function (stenotic: 92.9%, regurgitant: 87.9%, normal: 94.3%; p=0.23). Predominant root involvement was significantly more prevalent in male patients (24.8% versus 5.2% in females; p<0.001). In multivariate analysis, predominant aortic valve regurgitation (OR=1.83; p=0.028) independently predicted root site, while predominant aortic valve stenosis (OR=3.70; p=0.001), bicuspidity (OR=2.90; p=0.005) and female sex (OR=6.10; p<0.001) predicted mid-ascending site. CONCLUSIONS: Pathogenetical considerations arise from the evidence of preferential mid-ascending localization of bicuspid-associated aortic dilatations. This finding is consistent with previous studies on bicuspid valve models revealing a wall stress overload beyond the sino-tubular ridge.


Asunto(s)
Aorta/diagnóstico por imagen , Aorta/patología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Ecocardiografía Transesofágica , Dilatación Patológica , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA