Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 34(3): 664-672, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36478627

RESUMEN

BACKGROUND: Ventricular scar is traditionally highlighted on a bipolar voltage (BiVolt) map in areas of myocardium <0.50 mV. We describe an alternative approach using Ripple Mapping (RM) superimposed onto a BiVolt map to differentiate postinfarct scar from conducting borderzone (BZ) during ventricular tachycardia (VT) ablation. METHODS: Fifteen consecutive patients (left ventricular ejection fraction 30 ± 7%) underwent endocardial left ventricle pentaray mapping (median 5148 points) and ablation targeting areas of late Ripple activation. BiVolt maps were studied offline at initial voltage of 0.50-0.50 mV to binarize the color display (red and purple). RMs were superimposed, and the BiVolt limits were sequentially reduced until only areas devoid of Ripple bars appeared red, defined as RM-scar. The surrounding area supporting conducting Ripple wavefronts in tissue <0.50 mV defined the RM-BZ. RESULTS: RM-scar was significantly smaller than the traditional 0.50 mV cutoff (median 4% vs. 12% shell area, p < .001). 65 ± 16% of tissue <0.50 mV supported Ripple activation within the RM-BZ. The mean BiVolt threshold that differentiated RM-scar from BZ tissue was 0.22 ± 0.07 mV, though this ranged widely (from 0.12 to 0.35 mV). In this study, septal infarcts (7/15) were associated with more rapid VTs (282 vs. 347 ms, p = .001), and had a greater proportion of RM-BZ to RM-scar (median ratio 3.2 vs. 1.2, p = .013) with faster RM-BZ conduction speed (0.72 vs. 0.34 m/s, p = .001). Conversely, scars that supported hemodynamically stable sustained VT (6/15) were slower (367 ± 38 ms), had a smaller proportion of RM-BZ to RM-scar (median ratio 1.2 vs. 3.2, p = .059), and slower RM-BZ conduction speed (0.36 vs. 0.63 m/s, p = .036). RM guided ablation collocated within 66 ± 20% of RM-BZ, most concentrated around the RM-scar perimeter, with significant VT reduction (median 4.0 episodes preablation vs. 0 post, p < .001) at 11 ± 6 months follow-up. CONCLUSION: Postinfarct scars appear significantly smaller than traditional 0.50 mV cut-offs suggest, with voltage thresholds unique to each patient.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Cicatriz , Volumen Sistólico , Técnicas Electrofisiológicas Cardíacas , Función Ventricular Izquierda
2.
Europace ; 25(3): 863-872, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36576323

RESUMEN

AIMS: There is rising healthcare utilization related to the increasing incidence and prevalence of atrial fibrillation (AF) worldwide. Simplifying therapy and reducing hospital episodes would be a valuable development. The efficacy of a streamlined AF ablation approach was compared to drug therapy and a conventional catheter ablation technique for symptom control in paroxysmal AF. METHODS AND RESULTS: We recruited 321 patients with symptomatic paroxysmal AF to a prospective randomized, multi-centre, open label trial at 13 UK hospitals. Patients were randomized 1:1:1 to cryo-balloon ablation without electrical mapping with patients discharged same day [Ablation Versus Anti-arrhythmic Therapy for Reducing All Hospital Episodes from Recurrent (AVATAR) protocol]; optimization of drug therapy; or cryo-balloon ablation with confirmation of pulmonary vein isolation and overnight hospitalization. The primary endpoint was time to any hospital episode related to treatment for atrial arrhythmia. Secondary endpoints included complications of treatment and quality-of-life measures. The hazard ratio (HR) for a primary endpoint event occurring when comparing AVATAR protocol arm to drug therapy was 0.156 (95% CI, 0.097-0.250; P < 0.0001 by Cox regression). Twenty-three patients (21%) recorded an endpoint event in the AVATAR arm compared to 76 patients (74%) within the drug therapy arm. Comparing AVATAR and conventional ablation arms resulted in a non-significant HR of 1.173 (95% CI, 0.639-2.154; P = 0.61 by Cox regression) with 23 patients (21%) and 19 patients (18%), respectively, recording primary endpoint events (P = 0.61 by log-rank test). CONCLUSION: The AVATAR protocol was superior to drug therapy for avoiding hospital episodes related to AF treatment, but conventional cryoablation was not superior to the AVATAR protocol. This could have wide-ranging implications on how demand for AF symptom control is met. TRIAL REGISTRATION: Clinical Trials Registration: NCT02459574.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Antiarrítmicos/efectos adversos , Resultado del Tratamiento , Estudios Prospectivos , Hospitales , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Recurrencia
3.
Pacing Clin Electrophysiol ; 44(5): 883-894, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33813746

RESUMEN

BACKGROUND: Cryoballoon ablation for the treatment of patients with atrial fibrillation (AF) has been utilized in Europe for >15 years. OBJECTIVES: Report patient and procedural characteristics that influence the safety of cryoablation for the treatment of AF. METHODS: Patients enrolled in the prospective, multicenter Cryo AF Global Registry were treated at 38 European centers. Freedom from a ≥30s episode of AF/atrial flutter (AFL)/atrial tachycardia (AT) at 12-months and serious complications were analyzed. Univariate and multivariable models identified baseline patient and procedural characteristics that predicted a procedure-related complication. RESULTS: Of the 1418 subjects who completed an index procedure, the cohort was 62 ± 11 years of age, 37.7% female, and 72.2% paroxysmal AF (PAF). The mean procedure, left atrial dwell, and fluoroscopy times were 81 ± 34, 54 ± 25, and 14 ± 13 min, respectively. Among the 766 patients with 12-month follow-up, freedom from a ≥30 s AF/AFL/AT recurrence was 83.3% (95% CI: 79.8%-86.3%) and 71.6% (95% CI: 64.6%-77.4%) in patients with PAF and persistent AF. The serious procedure- and device-related adverse event rates were 4.7% and 2.0%. No baseline patient characteristic independently predicted a procedure-related adverse event; however, prolonged procedure duration (OR = 1.01 [95% CI: 1.00-1.01]), use of general anesthesia (OR = 1.71 [95% CI: 1.01-2.92]), and delivery of a cavotricuspid isthmus line (OR = 3.04 [95% CI: 1.01-9.20]) were each independently associated with the occurrence of a serious procedural safety event (all p < .05). CONCLUSIONS: Cryoballoon ablation is safe and effective in real-world use across a broad cohort of patients with AF.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/métodos , Europa (Continente) , Femenino , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recurrencia , Sistema de Registros
4.
Hum Mutat ; 41(12): 2195-2204, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33131149

RESUMEN

The identification of a pathogenic SCN5A variant confers an increased risk of conduction defects and ventricular arrhythmias (VA) in Brugada syndrome (BrS). However, specific aspects of sodium channel function that influence clinical phenotype have not been defined. A systematic literature search identified SCN5A variants associated with BrS. Sodium current (INa ) functional parameters (peak current, decay, steady-state activation and inactivation, and recovery from inactivation) and clinical features (conduction abnormalities [CA], spontaneous VA or family history of sudden cardiac death [SCD], and spontaneous BrS electrocardiogram [ECG]) were extracted. A total of 561 SCN5A variants associated with BrS were identified, for which data on channel function and clinical phenotype were available in 142. In the primary analysis, no relationship was found between any aspect of channel function and CA, VA/SCD, or spontaneous BrS ECG pattern. Sensitivity analyses including only variants graded pathogenic or likely pathogenic suggested that reduction in peak current and positive shift in steady-state activation were weakly associated with CA and VA/SCD, although sensitivity and specificity remained low. The relationship between in vitro assessment of channel function and BrS clinical phenotype is weak. The assessment of channel function does not enhance risk stratification. Caution is needed when extrapolating functional testing to the likelihood of variant pathogenicity.


Asunto(s)
Síndrome de Brugada/genética , Síndrome de Brugada/patología , Mutación/genética , Canal de Sodio Activado por Voltaje NAV1.5/genética , Arritmias Cardíacas/genética , Síndrome de Brugada/diagnóstico por imagen , Electrocardiografía , Sistema de Conducción Cardíaco/patología , Humanos , Fenotipo
5.
Europace ; 22(7): 1026-1035, 2020 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32142113

RESUMEN

AIMS: Study sex-differences in efficacy and safety of atrial fibrillation (AF) ablation. METHODS AND RESULTS: We assessed first AF ablation outcomes on continuous anticoagulation in 633 patients [209 (33%) women and 424 (67%) men] in a pre-specified subgroup analysis of the AXAFA-AFNET 5 trial. We compared the primary outcome (death, stroke or transient ischaemic attack, or major bleeding) and secondary outcomes [change in quality of life (QoL) and cognitive function] 3 months after ablation. Women were older (66 vs. 63 years, P < 0.001), more often symptomatic, had lower QoL and a longer history of AF. No sex differences in ablation procedure were found. Women stayed in hospital longer than men (2.1 ± 2.3 vs. 1.6 ± 1.3 days, P = 0.004). The primary outcome occurred in 19 (9.1%) women and 26 (6.1%) men, P = 0.19. Women experienced more bleeding events requiring medical attention (5.7% vs. 2.1%, P = 0.03), while rates of tamponade (1.0% vs. 1.2%) or intracranial haemorrhage (0.5% vs. 0%) did not differ. Improvement in QoL after ablation was similar between the sexes [12-item Short Form Health Survey (SF-12) physical 5.1% and 5.9%, P = 0.26; and SF-12 mental 3.7% and 1.6%, P = 0.17]. At baseline, mild cognitive impairment according to the Montreal Cognitive Assessment (MoCA) was present in 65 (32%) women and 123 (30%) men and declined to 23% for both sexes at end of follow-up. CONCLUSION: Women and men experience similar improvement in QoL and MoCA score after AF ablation on continuous anticoagulation. Longer hospital stay, a trend towards more nuisance bleeds, and a lower overall QoL in women were the main differences observed.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Accidente Cerebrovascular , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Calidad de Vida , Caracteres Sexuales , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
6.
Europace ; 22(9): 1337-1344, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32725107

RESUMEN

AIMS: Freedom from atrial fibrillation (AF) at 1 year can be achieved in 50-70% of patients undergoing catheter ablation. Recurrent AF early after ablation most commonly terminates spontaneously without further interventional treatment but is associated with later recurrent AF. The aim of this investigation is to identify clinical and procedural factors associated with recurrence of AF early after ablation. METHODS AND RESULTS: We retrospectively analysed data for recurrence of AF within the first 3 months after catheter ablation from the randomized controlled AXAFA-AFNET 5 trial, which demonstrated that continuous anticoagulation with apixaban is as safe and as effective compared to vitamin K antagonists in 678 patients undergoing first AF ablation. The primary outcome of first recurrent AF within 90 days was observed in 163 (28%) patients, in which 78 (48%) patients experienced an event within the first 14 days post-ablation. After multivariable adjustment, a history of stroke/transient ischaemic attack [hazard ratio (HR) 1.54, 95% confidence interval (CI) 0.93-2.6; P = 0.11], coronary artery disease (HR 1.85, 95% CI 1.20-2.86; P = 0.005), cardioversion during ablation (HR 1.78, 95% CI 1.26-2.49; P = 0.001), and an age:sex interaction for older women (HR 1.01, 95% CI 1.00-1.01; P = 0.04) were associated with recurrent AF. The P-wave duration at follow-up was significantly longer for patients with AF recurrence (129 ± 31 ms vs. 122 ± 22 ms in patients without AF, P = 0.03). CONCLUSION: Half of all early AF recurrences within the first 3 months post-ablation occurred within the first 14 days post-ablation. Vascular disease and cardioversion during the procedure are strong predictors of recurrent AF. P-wave duration at follow-up was longer in patients with recurrent AF. TRIAL REGISTRATION: Clinicaltrials.gov identifier NCT02227550.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Femenino , Humanos , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
7.
Am Heart J ; 214: 36-45, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31152874

RESUMEN

Atrial Fibrillation (AF) ablation using the cryoballoon is effective at reducing symptomatic AF episodes. The prevalence of AF is increasing with the aging population and access to such treatment would be enhanced by reducing the resource requirements. Relinquishing electrical mapping of the pulmonary veins (PV) removes the need for PV catheters, electrical recording equipment and staff trained in using this equipment. Moreover, the majority of complications are peri-procedural so overnight hospitalization maybe unnecessary. We tested this streamlined approach to AF ablation against medical therapy using the endpoint of time to all hospital episodes. METHODS: The AVATAR-AF study is a prospective, multicenter, randomized controlled trial testing the primary hypothesis that AF ablation done without PV mapping or overnight hospitalization is more effective than anti-arrhythmic drugs at reducing all hospital episodes related to recurrent atrial arrhythmias. We included a third arm to test a secondary hypothesis that confirming PV entrance block as per consensus guidelines can improve outcomes. Three hundred twenty-one patients with documented paroxysmal AF will be randomized in a 1:1:1 manner to one of three investigation arms: (1) AVATAR protocol cryoballoon ablation without assessment of acute PV isolation or overnight hospitalization; (2) medical therapy with anti-arrhythmic drugs; or (3) conventional cryoballoon ablation with assessment of acute PV isolation. The primary endpoint is defined as the time to all hospital episodes (including outpatient consultation) related to treatment for atrial arrhythmia. CONCLUSION: The AVATAR-AF study will determine whether the resource utilization for AF ablation can be reduced whilst maintaining superiority over medical therapy.


Asunto(s)
Antiarrítmicos/uso terapéutico , Fibrilación Atrial , Ablación por Catéter/métodos , Criocirugía/métodos , Hospitalización , Venas Pulmonares/cirugía , Ensayos Clínicos Controlados Aleatorios como Asunto , Procedimientos Quirúrgicos Ambulatorios/métodos , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Estudios Cruzados , Fenómenos Electrofisiológicos , Humanos , Estudios Multicéntricos como Asunto , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Recurrencia , Evaluación de Síntomas , Resultado del Tratamiento
8.
J Cardiovasc Electrophysiol ; 30(11): 2629-2639, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31502368

RESUMEN

The retrograde aortic (RA) route is a widely used access route for mapping and ablation of ventricular tachycardias (VT) arising from the left ventricular endocardium. With the expanding role of VT ablation in patients with significant comorbidity, the choice between the RA and transseptal access routes is an increasingly important consideration. An individualized decision based on the location of the arrhythmogenic substrate, vascular anatomy, aortic valve morphology, and operator experience is necessary when deciding on the optimal access route. Among patients with challenging vascular anatomy, growing experience from structural interventions such as transcatheter aortic valve replacements and peripheral vascular interventions has provided valuable insights into techniques for safe retrograde access. The present review focuses on patient selection for RA access, potential complications associated with the technique, and optimal approaches for access in patients with challenging vascular or aortic valve anatomy.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter/métodos , Electrocardiografía/métodos , Monitoreo Intraoperatorio/métodos , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Técnicas Electrofisiológicas Cardíacas/métodos , Humanos , Imagenología Tridimensional/métodos , Taquicardia Ventricular/fisiopatología
9.
J Cardiovasc Electrophysiol ; 30(1): 118-127, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30203441

RESUMEN

BACKGROUND: A large number of SCN5A variants have been reported to underlie Brugada syndrome (BrS). However, the evidence supporting individual variants is highly heterogeneous. OBJECTIVE: We systematically re-evaluated all SCN5A variants reported in BrS using the 2015 American college of medical genetics and genomics and the association for molecular pathology (ACMG-AMP) guidelines. METHODS: A PubMed/Embase search was performed to identify all reported SCN5A variants in BrS. Standardized bioinformatic re-analysis (SIFT, PolyPhen, Mutation Taster, Mutation assessor, FATHMM, GERP, PhyloP, and SiPhy) and re-evaluation of frequency in the gnomAD database were performed. Fourteen ACMG-AMP rules were deemed applicable for SCN5A variant analysis. RESULTS: Four hundred and eighty unique SCN5A variants were identified, the majority of which 425 (88%) were coding variants. One hundred and fifty-six of 425 (37%) variants were classified as pathogenic/likely pathogenic. Two hundred and fifty-eight (60%) were classified as variants of uncertain significance, while a further 11 (3%) were classified as benign/likely benign. When considering the subset of variants that were considered "null" variants separately, 95% fulfilled criteria for pathogenicity/likely pathogenicity. In contrast, only 17% of missense variants fulfilled criteria for pathogenicity/likely pathogenicity. Importantly, however, only 25% of missense variants had available functional data, which was a major score driver for pathogenic classification. CONCLUSION: Based on contemporary ACMG-AMP guidelines, only a minority of SCN5A variants implicated in BrS fulfill the criteria for pathogenicity or likely pathogenicity.


Asunto(s)
Síndrome de Brugada/genética , Variación Genética , Canal de Sodio Activado por Voltaje NAV1.5/genética , Potenciales de Acción , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/metabolismo , Síndrome de Brugada/fisiopatología , Predisposición Genética a la Enfermedad , Frecuencia Cardíaca , Humanos , Canal de Sodio Activado por Voltaje NAV1.5/metabolismo , Fenotipo , Factores de Riesgo
10.
Europace ; 21(5): 738-745, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-30753411

RESUMEN

AIMS: Video-assisted thoracoscopic surgery (VATS) ablation has been advocated as a treatment option for non-paroxysmal atrial fibrillation (AF) in recent guidelines. Real-life data on its safety and efficacy during a centre's early experience are sparse. METHODS AND RESULTS: Thirty patients (28 persistent/longstanding persistent AF) underwent standalone VATS ablation for AF by an experienced thoracoscopic surgeon, with the first 20 cases proctored by external surgeons. Procedural and follow-up outcomes were collected prospectively, and compared with 90 propensity-matched patients undergoing contemporaneous catheter ablation (CA). Six (20.0%) patients undergoing VATS ablation experienced ≥1 major complication (death n = 1, stroke n = 2, conversion to sternotomy n = 3, and phrenic nerve injury n = 2). This was significantly higher than the 1.1% major complication rate (tamponade requiring drainage n = 1) seen with CA (P < 0.001). Twelve-month single procedure arrhythmia-free survival rates without antiarrhythmic drugs were 56% in the VATS and 57% in the CA cohorts (P = 0.22), and 78% and 80%, respectively given an additional CA and antiarrhythmic drugs (P = 0.32). CONCLUSION: During a centre's early experience, VATS ablation may have similar success rates to those from an established CA service, but carry a greater risk of major complications. Those embarking on a programme of VATS AF ablation should be aware that complication and success rates may differ from those reported by selected high-volume centres.


Asunto(s)
Fibrilación Atrial/cirugía , Taponamiento Cardíaco , Ablación por Catéter , Conversión a Cirugía Abierta/estadística & datos numéricos , Complicaciones Intraoperatorias , Cirugía Torácica Asistida por Video , Fibrilación Atrial/diagnóstico , Taponamiento Cardíaco/epidemiología , Taponamiento Cardíaco/etiología , Taponamiento Cardíaco/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Estudios de Cohortes , Investigación sobre la Eficacia Comparativa , Femenino , Humanos , Complicaciones Intraoperatorias/epidemiología , Complicaciones Intraoperatorias/etiología , Masculino , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud , Nervio Frénico/lesiones , Cirugía Torácica Asistida por Video/efectos adversos , Cirugía Torácica Asistida por Video/métodos , Reino Unido
11.
Pacing Clin Electrophysiol ; 42(11): 1448-1455, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31538362

RESUMEN

BACKGROUND: Atrial fibrillation (AF) ablation is a complex procedure, generally requiring at least one overnight hospital stay. We investigated the safety and feasibility of early mobilization and same-day discharge following streamlined peri-ablation management for AF. METHODS: From 2014, we offered same-day discharge to selected patients who underwent uncomplicated AF ablation on the morning lists, with ultrasound-guided femoral access, uninterrupted warfarin or minimal interruption in novel oral anticoagulants, and reversal of intraprocedural heparin with protamine. Patients were discharged 6-8 h postprocedure and offered access to a dedicated nurse helpline. RESULTS: Of 1599 AF ablation cases performed from April 2014 to March 2017, 811 (50.7%) were performed on the morning lists and 169/811 (20.8%) were discharged on the same day. Excluding 26 research cases, 1/143 (0.7%) had transient right phrenic nerve palsy and five (3.5%) cases experienced minor problems that did not preclude same-day discharge; three (2.1%) needed rehospitalization postdischarge: one for pericarditic chest pain and two for nausea/vomiting. Compared to 642 overnight cases, day-case procedures were shorter, more likely to be redos, to be performed under sedation rather than general anesthesia, and less likely to involve linear lesions and electrical cardioversion. There were no significant differences in patient age, gender, body mass index, CHA2 DS2 -VASc, in preprocedural anticoagulation regimen (warfarin vs novel anticoagulants vs no anticoagulation) and in choice of ablation method (cryoballoon vs radiofrequency). CONCLUSIONS: Selective same-day discharge after AF ablation is safe and feasible using a streamlined peri-procedural care protocol. Wider adoption can potentially reduce health-care costs while improving patient experience.


Asunto(s)
Procedimientos Quirúrgicos Ambulatorios , Fibrilación Atrial/cirugía , Ablación por Catéter , Alta del Paciente , Selección de Paciente , Anciano , Ablación por Catéter/efectos adversos , Ambulación Precoz , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Factores de Tiempo
12.
Eur Heart J ; 39(32): 2942-2955, 2018 08 21.
Artículo en Inglés | MEDLINE | ID: mdl-29579168

RESUMEN

Aims: It is recommended to perform atrial fibrillation ablation with continuous anticoagulation. Continuous apixaban has not been tested. Methods and results: We compared continuous apixaban (5 mg b.i.d.) to vitamin K antagonists (VKA, international normalized ratio 2-3) in atrial fibrillation patients at risk of stroke a prospective, open, multi-centre study with blinded outcome assessment. Primary outcome was a composite of death, stroke, or bleeding (Bleeding Academic Research Consortium 2-5). A high-resolution brain magnetic resonance imaging (MRI) sub-study quantified acute brain lesions. Cognitive function was assessed by Montreal Cognitive Assessment (MoCA) at baseline and at end of follow-up. Overall, 674 patients (median age 64 years, 33% female, 42% non-paroxysmal atrial fibrillation, 49 sites) were randomized; 633 received study drug and underwent ablation; 335 undertook MRI (25 sites, 323 analysable scans). The primary outcome was observed in 22/318 patients randomized to apixaban, and in 23/315 randomized to VKA {difference -0.38% [90% confidence interval (CI) -4.0%, 3.3%], non-inferiority P = 0.0002 at the pre-specified absolute margin of 0.075}, including 2 (0.3%) deaths, 2 (0.3%) strokes, and 24 (3.8%) ISTH major bleeds. Acute small brain lesions were found in a similar number of patients in each arm [apixaban 44/162 (27.2%); VKA 40/161 (24.8%); P = 0.64]. Cognitive function increased at the end of follow-up (median 1 MoCA unit; P = 0.005) without differences between study groups. Conclusions: Continuous apixaban is safe and effective in patients undergoing atrial fibrillation ablation at risk of stroke with respect to bleeding, stroke, and cognitive function. Further research is needed to reduce ablation-related acute brain lesions.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Pirazoles/uso terapéutico , Piridonas/uso terapéutico , Accidente Cerebrovascular/prevención & control , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/psicología , Encéfalo/diagnóstico por imagen , Cognición , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Pirazoles/efectos adversos , Piridonas/efectos adversos , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico por imagen , Resultado del Tratamiento , Vitamina K/antagonistas & inhibidores
13.
J Cardiovasc Electrophysiol ; 29(11): 1493-1499, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30230085

RESUMEN

INTRODUCTION: Demonstration of exit block after pulmonary vein isolation (PVI) is the cornerstone of ablation for atrial fibrillation (AF). It requires the demonstration of local pulmonary vein (PV) capture and absence of conduction to the atrium but is often challenging due to the inability to see local paced PV-evoked potentials. We retrospectively examined the ability of adenosine to augment this technique during CARTO-based radiofrequency ablation procedures. METHODS: Retrospective analysis of evoked PV potentials during adenosine administration while testing for PV exit block at a single UK center. RESULTS: One hundred and twenty-nine PVs in 33 patients were isolated using radiofrequency energy to demonstrate entry block. Of those, the pacing of 24 veins under baseline conditions did not clearly demonstrate local PV-evoked potentials sufficient to be sure that the local vein was truly captured and dissociated from the atrium. Adenosine was administered in 19 of these, with 10 of 19 (52.6%) veins then demonstrating clear local PV-evoked potentials transiently during adenosine administration, sufficient to allow assessment of definite exit block. CONCLUSION: Adenosine administered during PV pacing allows transient visualization of local PV-evoked potentials after PVI facilitating the clearer demonstration of PV exit block in over 50% veins.


Asunto(s)
Adenosina/administración & dosificación , Antiarrítmicos/administración & dosificación , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Venas Pulmonares/efectos de los fármacos , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Humanos , Estudios Retrospectivos
14.
Catheter Cardiovasc Interv ; 89(3): 484-492, 2017 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-27651124

RESUMEN

OBJECTIVES: This study aimed at assessing the feasibility and long-term efficacy of left atrial appendage occlusion (LAAO) in a "real world" setting. BACKGROUND: Although LAAO has recently emerged as an alternative to oral anticoagulants in patients with atrial fibrillation for the prevention of thromboembolic stroke, "real world" data about the procedure with different devices are lacking. METHODS: Eight centers in the United Kingdom contributed to a retrospective registry for LAAO procedures undertaken between July 2009 and November 2014. RESULTS: A total of 371 patients (72.9 ± 8.3 years old, 88.9% males) were enrolled. The overall procedure success was 92.5%, with major events in 3.5% of cases. The device choice was Watchman in 63% of cases, Amplatzer Cardiac Plug in 34.7%, Lariat in 1.7%, and Coherex WaveCrest in 0.6%. A significant improvement in procedure success (from 89.2% to 95.7%; P = 0.018) and reduction of acute major complications (from 6.5% to 0.5%; P = 0.001) were observed between procedures in the first and the second half of the recruitment time. An annual 90.1% relative risk reduction (RRR) for ischemic stroke, an 87.2% thromboembolic events RRR, and a 92.9% major bleeding RRR were observed, if compared with the predicted annual risks based on CHADS2, CHA2DS2-Vasc, and HAS-BLED scores, respectively, over a follow-up period of 24.7 ± 16.07 months. CONCLUSIONS: LAAO can be performed safely in a real world setting with good implant success rates and procedural outcomes. The long-term benefits of the procedure are reassuring in terms of both ischemic events and avoidance of severe bleeding associated with anticoagulation in this patient group. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial/terapia , Cateterismo Cardíaco , Embolia Intracraneal/prevención & control , Accidente Cerebrovascular/prevención & control , Anciano , Anciano de 80 o más Años , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/fisiopatología , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Estudios de Factibilidad , Femenino , Humanos , Embolia Intracraneal/etiología , Masculino , Persona de Mediana Edad , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/etiología , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
15.
Europace ; 19(5): 775-783, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-27247002

RESUMEN

AIMS: Force-Time Integral (FTI) is commonly used as a marker of ablation lesion quality during pulmonary vein isolation (PVI), but does not incorporate power. Ablation Index (AI) is a novel lesion quality marker that utilizes contact force, time, and power in a weighted formula. Furthermore, only a single FTI target value has been suggested despite regional variation in left atrial wall thickness. We aimed to study AI's and FTI's relationships with PV reconnection at repeat electrophysiology study, and regional threshold values that predicted no reconnection. METHODS AND RESULTS: Forty paroxysmal atrial fibrillation patients underwent contact force-guided PVI, and the minimum and mean AI and FTI values for each segment were identified according to a 12-segment model. All patients underwent repeat electrophysiology study at 2 months, regardless of symptoms, to identify sites of PV reconnection. Late PV reconnection was seen in 53 (11%) segments in 25 (62%) patients. Reconnected segments had significantly lower minimum AI [308 (252-336) vs. 373 (323-423), P < 0.0001] and FTI [137 (92-182) vs. 228 (157-334), P < 0.0001] compared with non-reconnected segments. Minimum AI and FTI were both independently predictive, but AI had a smaller P value. Higher minimum AI and FTI values were required to avoid reconnection in anterior/roof segments than for posterior/inferior segments (P < 0.0001). No reconnection was seen where the minimum AI value was ≥370 for posterior/inferior segments and ≥480 for anterior/roof segments. CONCLUSION: The minimum AI value in a PVI segment is independently predictive of reconnection of that segment at repeat electrophysiology study. Higher AI and FTI values are required for anterior/roof segments than for posterior/inferior segments to prevent reconnection.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal/métodos , Diagnóstico por Computador/métodos , Sistema de Conducción Cardíaco/cirugía , Evaluación de Resultado en la Atención de Salud/métodos , Venas Pulmonares/cirugía , Fibrilación Atrial/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
16.
J Cardiovasc Electrophysiol ; 27(4): 381-9, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26786052

RESUMEN

INTRODUCTION: Acute reconnection of pulmonary veins (PVs) is frequently seen in the waiting period following pulmonary vein isolation (PVI). There are concerns that reablation at these sites may not be durably effective due to tissue edema caused by the initial ablation. We aimed to prospectively study the relationship between acute and late reconnection. METHODS AND RESULTS: Wide-area circumferential PVI was performed in 40 paroxysmal AF patients. Spontaneous reconnection was assessed after a minimum 20-minute waiting period, with adenosine administered to unmask dormant reconnection. All sites of acute reconnection were ablated to reisolate the PV. All 40 patients then underwent repeat electrophysiology study after 2 months, regardless of symptoms, to identify late reconnection. Sites of acute and late reconnection were compared according to a 12-segment PVI model. Acute reconnection was seen in 28 (6%) PVI segments in 20 (50%) patients, affecting 24/160 (15%) PVs. All were successfully reisolated. At repeat electrophysiology study, 51 (11%) PVI segments were reconnected in 25 (62%) patients, affecting 41 (25%) PVs. The proportion of PVI segments with and without acute reconnection exhibiting late reconnection at repeat study was no different (14% vs. 10%, P = 0.524). There was also no difference in late reconnection between PVI circles or patients with and without acute reconnection. CONCLUSION: Most PVI segments that undergo further ablation for acute reconnection show persistent isolation at repeat electrophysiology study, and the rate of late reconnection for these segments is no different to that for segments that did not acutely reconnect. This implies that effective reablation is delivered at these sites.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Sistema de Conducción Cardíaco/fisiopatología , Venas Pulmonares/cirugía , Enfermedad Aguda , Fibrilación Atrial/prevención & control , Mapeo del Potencial de Superficie Corporal/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Recurrencia , Reoperación/métodos , Resultado del Tratamiento
17.
Europace ; 18(1): 113-20, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26541709

RESUMEN

AIMS: Septal reduction is needed for hypertrophic obstructive cardiomyopathy (HOCM) patients with severe left ventricular outflow tract (LVOT) gradients and symptoms despite medication. Myectomy cannot be performed in all. Alcohol septal ablation cannot be performed in 5-15% due to technical difficulties. A method of delivering percutaneous tissue damage to the septum that is not reliant on coronary anatomy is desirable. To directly ablate the interventricular septum at the mitral valve (MV) systolic anterior motion (SAM)-septal contact point using radiofrequency (RF) energy guided by CARTOSound. METHODS AND RESULTS: Five patients underwent RF ablation (RFA); we describe follow-up at 6 months in four patients. Intracardiac echocardiography (ICE) images are merged with CARTO to create a shell of the cardiac chambers. The SAM-septal contact area is marked from ICE images and mapped on to the CARTO shell; this becomes the target for RF delivery. Conduction tissue is mapped and avoided where possible. Twenty-eight to 42 min of RF energy was delivered to the target area using retrograde aortic access and SmartTouch catheters. Resting LVOT gradient improved from 64.2 (±50.6) to 12.3 (±2.5) mmHg. Valsalva/exercise-induced gradient reduced from 93.5 (±30.9) to 23.3 (±8.3) mmHg. Three patients improved New York Heart Association status from III to II, one patient improved from class III to I. Exercise time on bicycle ergometer increased from 612 to 730 s. Cardiac magnetic resonance shows late gadolinium enhancement up to 8 mm depth at LV target myocardium. One patient died following a significant retroperitoneal haemorrhage. CONCLUSION: Radiofrequency ablation using CARTOSound(®) guidance is accurate and effective in treating LVOT gradients in HOCM in this preliminary group of patients.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Cardiomiopatía Hipertrófica/cirugía , Ablación por Catéter/métodos , Ecocardiografía/métodos , Cirugía Asistida por Computador/métodos , Obstrucción del Flujo Ventricular Externo/cirugía , Anciano , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Imagen Multimodal/métodos , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/diagnóstico , Obstrucción del Flujo Ventricular Externo/etiología , Tabique Interventricular/diagnóstico por imagen , Tabique Interventricular/cirugía
18.
Europace ; 18(1): 151-5, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26462697

RESUMEN

The purpose of this European Heart Rhythm Association survey was to assess the attitude, level of education, and knowledge concerning oral anticoagulants (OACs) among patients with atrial fibrillation (AF) taking vitamin K antagonists (VKAs), non-VKA oral anticoagulants (NOACs) or antiplatelets. A total of 1147 patients with AF [mean age 66 ± 13 years, 529 (45%) women] from 8 selected European countries responded to this survey. The overall use of OACs and antiplatelets was 77 and 15.3%, respectively. Of the patients taking OACs, 67% were on VKAs, 33% on NOACs, and 17.9% on a combination of OACs and antiplatelets. Among patients on VKAs, 91% correctly stated the target international normalized ratio (INR) level. The proportion of patients on VKA medication who were aware that monthly INR monitoring was required for this treatment and the proportion of patients on NOAC who knew that renal function monitoring at least annually was mandatory for NOACs was 76 and 21%, respectively. An indirect estimation of compliance indicated that 14.5% of patients temporarily discontinued the treatment, and 26.5% of patients reported having missed at least one dose. The survey shows that there is room for improvement regarding education and adherence of patients taking OACs, particularly regarding monitoring requirements for NOACs.


Asunto(s)
Anticoagulantes/administración & dosificación , Fibrilación Atrial/tratamiento farmacológico , Cumplimiento de la Medicación/estadística & datos numéricos , Educación del Paciente como Asunto/estadística & datos numéricos , Conocimiento de la Medicación por el Paciente/estadística & datos numéricos , Tromboembolia/prevención & control , Administración Oral , Anciano , Fibrilación Atrial/epidemiología , Fibrilación Atrial/psicología , Actitud Frente a la Salud , Autoevaluación Diagnóstica , Europa (Continente)/epidemiología , Femenino , Encuestas de Atención de la Salud , Humanos , Masculino , Inhibidores de Agregación Plaquetaria/administración & dosificación , Tromboembolia/epidemiología , Tromboembolia/psicología , Vitamina K/antagonistas & inhibidores
19.
Europace ; 18(3): 463-7, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26899998

RESUMEN

The purpose of this patient survey was to analyse the knowledge about blood thinning medications relative to gender, age, education, and region of residence in patients with atrial fibrillation (AF). A total of 1147 patients with AF [mean age 66 ± 13 years, 529 (45%) women] from eight European countries responded to this survey. Most patients understood that the indication for anticoagulation therapy was to 'thin the blood', but 8.1% responded that the purpose of the medication was to treat the arrhythmia. Patients with college or university grades reported less frequent deviations from their target INR range compared with those without schooling (2.8% vs. 5.1%, P < 0.05). The awareness of anticoagulation-related risk of bleedings was lowest in patients without schooling (38.5%) and highest in those with college and university education (57.0%), P < 0.05. The same pattern was also observed regarding patient's awareness of non-vitamin K antagonist oral anticoagulants (NOACs): 56.5% of the patients with university education and only 20.5% of those without schooling (P < 0.05) knew about NOACs, indicating that information about new anticoagulation therapies remains well below the target. Bleeding events were statistically less frequent in patients on NOACs compared with vitamin K antagonists. The education level and patients' knowledge have a direct influence on the global management of the anticoagulation.


Asunto(s)
Anticoagulantes/administración & dosificación , Fibrilación Atrial/tratamiento farmacológico , Conocimientos, Actitudes y Práctica en Salud , Educación del Paciente como Asunto , Pacientes/psicología , Accidente Cerebrovascular/prevención & control , Administración Oral , Anciano , Anticoagulantes/efectos adversos , Fibrilación Atrial/sangre , Fibrilación Atrial/complicaciones , Coagulación Sanguínea/efectos de los fármacos , Monitoreo de Drogas/métodos , Escolaridad , Europa (Continente) , Femenino , Encuestas de Atención de la Salud , Hemorragia/inducido químicamente , Humanos , Relación Normalizada Internacional , Masculino , Cumplimiento de la Medicación , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/etiología , Resultado del Tratamiento , Vitamina K/antagonistas & inhibidores
20.
J Cardiovasc Electrophysiol ; 26(4): 397-403, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25588685

RESUMEN

INTRODUCTION: Inability to predict clinical outcome despite acutely successful pulmonary vein isolation (PVI) remains the Achilles' heel of atrial fibrillation ablation (AFA). Arrhythmia recurrence is frequently due to recovery of radiofrequency (RF) ablation lesions believed to be complete at the original procedure. OBJECTIVES: We hypothesized that a high ratio between post-AFA levels of serum high sensitivity cardiac troponin T (HScTnT), a highly specific marker of acute myocardial injury, and duration of RF application (the ablation effectiveness quotient, AEQ) would indicate effective ablation and correlate with early clinical success. METHODS: We prospectively measured HScTnT levels in 60 patients (42 [70%] male, 22 [37%] with paroxysmal AF [PAF], mean age 62.5 ± 10.6 years) 12-18 hours after AFA and calculated the AEQ for each. Patients were followed-up with ECGs and Holter monitors for recurrence of atrial tachyarrhythmia (AT). RESULTS: Early recurrence of AT within 6 months occurred in 22 (37%). AT recurrence was not significantly related to left atrial size or comorbidities, nor to RF time or HScTnT level. Mean AEQ was significantly lower in those with recurrence than those without (0.35 ± 0.14 ng/L/s vs. 0.45 ± 0.18 ng/L/s), P = 0.02. Subgroup analysis showed this finding was due to patients with PAF in whom early significance was maintained to one year, with an AEQ >0.4 ng/L/s having 75% sensitivity and 90% specificity in predicting freedom from AT. CONCLUSION: A high AEQ correlates well with freedom from AT in patients with PAF in both the short and medium term. If confirmed in further studies, AEQ may become a useful marker of risk of AT post-AFA.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Tempo Operativo , Troponina T/sangre , Anciano , Área Bajo la Curva , Fibrilación Atrial/sangre , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Biomarcadores/sangre , Electrocardiografía , Inglaterra , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Curva ROC , Recurrencia , Factores de Riesgo , Método Simple Ciego , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA