Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Pediatr ; 221: 47-54.e4, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32145967

RESUMEN

OBJECTIVE: To evaluate whether teaching mothers about neonatal jaundice will decrease the incidence of acute bilirubin encephalopathy among infants admitted for jaundice. STUDY DESIGN: This was a multicenter, before-after and cross-sectional study. Baseline incidences of encephalopathy were obtained at 4 collaborating medical centers between January 2014 and May 2015 (Phase 1). Structured jaundice instruction was then offered (May to November 2015; Phase 2) in antenatal clinics and postpartum. Descriptive statistics and logistic regression models compared 3 groups: 843 Phase 1 controls, 338 Phase 2 infants whose mothers received both antenatal and postnatal instruction (group A), and 215 Phase 2 infants whose mothers received no instruction (group B) either because the program was not offered to them or by choice. RESULTS: Acute bilirubin encephalopathy occurred in 147 of 843 (17%) Phase 1 and 85 of 659 (13%) Phase 2 admissions, which included 63 of 215 (29%) group B and 5 of 338 (1.5%) group A infants. OR for having acute bilirubin encephalopathy, comparing group A and group B infants adjusted for confounding risk factors, was 0.12 (95% CI 0.03-0.60). Delayed care-seeking (defined as an admission total bilirubin ≥18 mg/dL at age ≥48 hours) was the strongest single predictor of acute bilirubin encephalopathy (OR 11.4; 6.6-19.5). Instruction decreased delay from 49% to 17%. Other major risk factors were home births (OR 2.67; 1.69-4.22) and hemolytic disease (hematocrit ≤35% plus bilirubin ≥20 mg/dL) (OR 3.03; 1.77-5.18). The greater rate of acute bilirubin encephalopathy with home vs hospital birth disappeared if mothers received jaundice instruction. CONCLUSIONS: Providing information about jaundice to mothers was associated with a reduction in the incidence of bilirubin encephalopathy per hospital admission.


Asunto(s)
Ictericia/complicaciones , Kernicterus/epidemiología , Kernicterus/etiología , Madres/educación , Enfermedad Aguda , Estudios Transversales , Femenino , Humanos , Incidencia , Lactante , Recién Nacido , Kernicterus/prevención & control , Masculino , Nigeria/epidemiología , Aceptación de la Atención de Salud
2.
Niger J Med ; 25(3): 259-63, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-30011170

RESUMEN

Background: Nosocomial infections pose a great challenge on healthcare systems. Although surfaces in neonatal wards, umbilical stump wounds and catheter are responsible for a high number of nosocomial infections due to bacteria. The aim of this study was to determine the bacterial profile of air and surface contamination in the special care baby unit of a tertiary hospital in Jos, Nigeria. Methods: Surface and air samples were cultured and antibiotic susceptibility of isolated bacteria were determined. Results: The bacterial profile of air and surface samples showed that Klebsiella was the most common bacteria followed by Staphyllococcus; while the least was Escherichia. Most of the bacteria were isolated from the out-born term area of the special care baby unit. All the bacteria isolated were susceptible to ceftriaxone and meropenem. Conclusion: This study showed that all areas of the special care baby unit of the hospital have bacterial, indicating that these are a potential source of cross-infection from healthcare workers to the neonatal patients.


Asunto(s)
Microbiología del Aire , Bacterias/aislamiento & purificación , Lechos/microbiología , Infección Hospitalaria , Incubadoras para Lactantes/microbiología , Unidades de Cuidado Intensivo Neonatal , Salas Cuna en Hospital , Antibacterianos/farmacología , Bacterias/efectos de los fármacos , Ceftriaxona/farmacología , Escherichia coli/efectos de los fármacos , Escherichia coli/aislamiento & purificación , Humanos , Recién Nacido , Klebsiella/efectos de los fármacos , Klebsiella/aislamiento & purificación , Meropenem , Pruebas de Sensibilidad Microbiana , Nigeria , Pseudomonas aeruginosa/efectos de los fármacos , Pseudomonas aeruginosa/aislamiento & purificación , Staphylococcus aureus/efectos de los fármacos , Staphylococcus aureus/aislamiento & purificación , Centros de Atención Terciaria , Tienamicinas/farmacología
3.
Trop Doct ; 52(4): 503-509, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35950793

RESUMEN

Respiratory distress contributes to the high burden of preterm mortality globally. The aim of our study was to evaluate the use of low-cost Bubble Continuous Positive Airway Pressure devices for treating respiratory distress and their outcomes in preterm infants weighing <1500g. Data was extracted from admission records of 211 infants over two distinct 4-year periods before and after introduction of bCPAP. With survival rates of 26.7% and 61.8% in the pre and post bCPAP eras respectively, significantly improved outcomes were found.


Asunto(s)
Presión de las Vías Aéreas Positiva Contínua , Síndrome de Dificultad Respiratoria del Recién Nacido , Humanos , Lactante , Recién Nacido , Recien Nacido Prematuro , Recién Nacido de muy Bajo Peso , Nigeria , Síndrome de Dificultad Respiratoria del Recién Nacido/terapia , Centros de Atención Terciaria , Resultado del Tratamiento
4.
Trop Doct ; 48(2): 142-146, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29153050

RESUMEN

Locally fabricated phototherapy devices (LFPDs) are widely used in Nigeria for the treatment of neonatal jaundice. Ours was a cross-sectional observational study of all LFPDs in major hospitals in Jos between January and March 2015. We evaluated a total of 24 LFPDs. The irradiance at the level of the baby was in the range of 2-23.9 µW/cm2/nm. Fourteen devices had the recommended irradiance of ≥10 µW/cm2/nm and none had irradiance in the intensive range. Decreasing distance from the baby, presence of reflectors and increasing number of flourecent tubes significantly contributed to higher irradiance. A combination of six tubes, presence of reflectors and a distance of 10 cm from the baby produced a mean irradiance of 23.40 µW/cm2/nm. The irradiance of LFPDs varies widely and can be improved by simple modifications.


Asunto(s)
Ictericia Neonatal/terapia , Fototerapia/instrumentación , Dosis de Radiación , Radiometría , Estudios Transversales , Hospitales , Humanos , Lactante , Nigeria
5.
BMC Res Notes ; 4: 562, 2011 Dec 24.
Artículo en Inglés | MEDLINE | ID: mdl-22195995

RESUMEN

BACKGROUND: Worldwide 15.5% of neonates are born with low birth weight, 95.6% of them in the developing countries. Prematurity accounts for 10% of neonatal mortality globally. The purpose of this study was to evaluate the effects of birth weight and gender on neonatal outcome. FINDINGS: The data of 278 neonates managed in the Special Care Baby Unit (SCBU) of Jos University Teaching Hospital (JUTH) over a 2 year period from July 2006 to June 2008 were analyzed.One hundred and fifty nine (57.2%) were males and 119(42.8%) females. There were 87(31.3%) preterm and 191 (68.7%) term babies. Twelve of the babies died. Seven (2.52%) and 5 (1.80%) being males and females respectively. The neonatal mortality rate by gender was not significant (p > 0.05). The neonatal mortality was 25.2 deaths per 1000 live births for boys and 18.0 for girls. The mean birth weights of the preterm and term babies were 1.88 ± 0.47 kg and 3.02 ± 0.50 kg respectively, with a mean gestational age of 30.62 ± 3.65 weeks and 38.29 ± 0.99 weeks respectively.Eighty seven (31.3%) of the babies were of low birth weight, 188(67.6%) were of normal birth weight and 3(1.1%) high birth weight. Of the low birth weight babies, 6(2.2%) were term small for gestational age. Six (2.2%) of the preterm infants had normal birth weight.Eleven of the babies that died were preterm low birth weight. The overall mortality rate was 4.32%. The birth weight specific mortality rate was 126 per 1000 for the preterm low birth weight and 5 per 1000 for the term babies. Birth weight unlike gender is a significant predictor of mortality, mortality being higher in neonates of <2.5 kg (OR = 0.04; 95% Cl 0.005-0.310, p = 0.002) (p = 0.453). Seven (58.3%) and 4(33.3%) of the pre-terms that died were appropriate and large for gestational age respectively. Gestational age is not a significant predictor of neonatal mortality (p = 0.595). Babies delivered at less than 37 weeks of gestation recorded a higher rate of mortality than those of 37 weeks and above (p = 0.000).The subjects showed one or more major clinical indications for admission. The major clinical indications for the preterm and term babies were respectively as follows: neonatal sepsis 63(22.7%) and 124(44.6%); neonatal jaundice 32(11.1%) and 71(24.7%); malaria 9(3.1%) and 13(4.5%); birth asphyxia 3(1.0%) and 7(2.4%). Neonatal sepsis was a common denominator among the babies that died. CONCLUSION: Birth weight unlike gender is a significant predictor of neonatal outcome.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA