Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Phys Med ; 121: 103346, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38608421

RESUMEN

Partial breast irradiation for the treatment of early-stage breast cancer patients can be performed by means of Intra Operative electron Radiation Therapy (IOeRT). One of the main limitations of this technique is the absence of a treatment planning system (TPS) that could greatly help in ensuring a proper coverage of the target volume during irradiation. An IOeRT TPS has been developed using a fast Monte Carlo (MC) and an ultrasound imaging system to provide the best irradiation strategy (electron beam energy, applicator position and bevel angle) and to facilitate the optimisation of dose prescription and delivery to the target volume while maximising the organs at risk sparing. The study has been performed in silico, exploiting MC simulations of a breast cancer treatment. Ultrasound-based input has been used to compute the absorbed dose maps in different irradiation strategies and a quantitative comparison between the different options was carried out using Dose Volume Histograms. The system was capable of exploring different beam energies and applicator positions in few minutes, identifying the best strategy with an overall computation time that was found to be completely compatible with clinical implementation. The systematic uncertainty related to tissue deformation during treatment delivery with respect to imaging acquisition was taken into account. The potential and feasibility of a GPU based full MC TPS implementation of IOeRT breast cancer treatments has been demonstrated in-silico. This long awaited tool will greatly improve the treatment safety and efficacy, overcoming the limits identified within the clinical trials carried out so far.


Asunto(s)
Neoplasias de la Mama , Método de Montecarlo , Planificación de la Radioterapia Asistida por Computador , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/diagnóstico por imagen , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Electrones/uso terapéutico , Factores de Tiempo , Gráficos por Computador , Femenino , Órganos en Riesgo/efectos de la radiación
2.
Phys Med Biol ; 68(4)2023 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-36356308

RESUMEN

Objective. The Monte Carlo simulation software is a valuable tool in radiation therapy, in particular to achieve the needed accuracy in the dose evaluation for the treatment plans optimisation. The current challenge in this field is the time reduction to open the way to many clinical applications for which the computational time is an issue. In this manuscript we present an innovative GPU-accelerated Monte Carlo software for dose valuation in electron and photon based radiotherapy, developed as an update of the FRED (Fast paRticle thErapy Dose evaluator) software.Approach. The code transports particles through a 3D voxel grid, while scoring their energy deposition along their trajectory. The models of electromagnetic interactions in the energy region between 1 MeV-1 GeV available in literature have been implemented to efficiently run on GPUs, allowing to combine a fast tracking while keeping high accuracy in dose assessment. The FRED software has been bench-marked against state-of-art full MC (FLUKA, GEANT4) in the realm of two different radiotherapy applications: Intra-Operative Radio Therapy and Very High Electron Energy radiotherapy applications.Results. The single pencil beam dose-depth profiles in water as well as the dose map computed on non-homogeneous phantom agree with full-MCs at 2% level, observing a gain in processing time from 200 to 5000.Significance. Such performance allows for computing a plan with electron beams in few minutes with an accuracy of ∼%, demonstrating the FRED potential to be adopted for fast plan re-calculation in photon or electron radiotherapy applications.


Asunto(s)
Electrones , Programas Informáticos , Método de Montecarlo , Simulación por Computador , Fotones/uso terapéutico , Planificación de la Radioterapia Asistida por Computador/métodos , Dosificación Radioterapéutica , Fantasmas de Imagen , Algoritmos
3.
Sci Rep ; 10(1): 20735, 2020 11 26.
Artículo en Inglés | MEDLINE | ID: mdl-33244102

RESUMEN

The high dose conformity and healthy tissue sparing achievable in Particle Therapy when using C ions calls for safety factors in treatment planning, to prevent the tumor under-dosage related to the possible occurrence of inter-fractional morphological changes during a treatment. This limitation could be overcome by a range monitor, still missing in clinical routine, capable of providing on-line feedback. The Dose Profiler (DP) is a detector developed within the INnovative Solution for In-beam Dosimetry in hadronthErapy (INSIDE) collaboration for the monitoring of carbon ion treatments at the CNAO facility (Centro Nazionale di Adroterapia Oncologica) exploiting the detection of charged secondary fragments that escape from the patient. The DP capability to detect inter-fractional changes is demonstrated by comparing the obtained fragment emission maps in different fractions of the treatments enrolled in the first ever clinical trial of such a monitoring system, performed at CNAO. The case of a CNAO patient that underwent a significant morphological change is presented in detail, focusing on the implications that can be drawn for the achievable inter-fractional monitoring DP sensitivity in real clinical conditions. The results have been cross-checked against a simulation study.


Asunto(s)
Carbono/uso terapéutico , Iones/uso terapéutico , Planificación de la Radioterapia Asistida por Computador/métodos , Ensayos Clínicos como Asunto , Humanos , Radiometría/métodos
4.
Phys Med Biol ; 63(5): 055018, 2018 03 07.
Artículo en Inglés | MEDLINE | ID: mdl-29265011

RESUMEN

Proton and carbon ion beams are used in the clinical practice for external radiotherapy treatments achieving, for selected indications, promising and superior clinical results with respect to x-ray based radiotherapy. Other ions, like [Formula: see text] have recently been considered as projectiles in particle therapy centres and might represent a good compromise between the linear energy transfer and the radiobiological effectiveness of [Formula: see text] ion and proton beams, allowing improved tumour control probability and minimising normal tissue complication probability. All the currently used p, [Formula: see text] and [Formula: see text] ion beams allow achieving sharp dose gradients on the boundary of the target volume, however the accurate dose delivery is sensitive to the patient positioning and to anatomical variations with respect to photon therapy. This requires beam range and/or dose release measurement during patient irradiation and therefore the development of dedicated monitoring techniques. All the proposed methods make use of the secondary radiation created by the beam interaction with the patient and, in particular, in the case of [Formula: see text] ion beams are also able to exploit the significant charged radiation component. Measurements performed to characterise the charged secondary radiation created by [Formula: see text] and [Formula: see text] particle therapy beams are reported. Charged secondary yields, energy spectra and emission profiles produced in a poly-methyl methacrylate (PMMA) target by [Formula: see text] and [Formula: see text] beams of different therapeutic energies were measured at 60° and 90° with respect to the primary beam direction. The secondary yield of protons produced along the primary beam path in a PMMA target was obtained. The energy spectra of charged secondaries were obtained from time-of-flight information, whereas the emission profiles were reconstructed exploiting tracking detector information. The obtained measurements are in agreement with results reported in the literature and suggests the feasibility of range monitoring based on charged secondary particle detection: the implications for particle therapy monitoring applications are also discussed.


Asunto(s)
Radioterapia de Iones Pesados/efectos adversos , Helio/efectos adversos , Polimetil Metacrilato/efectos de la radiación , Monitoreo de Radiación/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Relación Dosis-Respuesta en la Radiación , Humanos , Dispersión de Radiación
5.
Phys Med Biol ; 62(4): 1310-1326, 2017 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-28114125

RESUMEN

Recently, the use of 4He particles in cancer radiotherapy has been reconsidered as they potentially represent a good compromise between protons and 12C ions. The first step to achieve this goal is the development of a dedicated treatment planning system, for which basic physics information such as the characterization of the beam lateral scattering and fragmentation cross sections are required. In the present work, the attenuation of 4He primary particles and the build-up of secondary charged fragments at various depths in water and polymethyl methacrylate were investigated experimentally for 120 and 200 MeV u-1 beams delivered by the synchrotron at the Heidelberg Ion-Beam Therapy Center, Heidelberg. Species and isotope identification was accomplished combining energy loss and time-of-flight measurements. Differential yields and energy spectra of all fragments types were recorded between 0° and 20° with respect to the primary beam direction.


Asunto(s)
Helio/química , Helio/uso terapéutico , Polimetil Metacrilato/química , Planificación de la Radioterapia Asistida por Computador/métodos , Sincrotrones/instrumentación , Agua/química , Humanos , Efectividad Biológica Relativa
6.
Phys Med Biol ; 62(4): 1438-1455, 2017 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-28114112

RESUMEN

Charged particle beams are used in particle therapy (PT) to treat oncological patients due to their selective dose deposition in tissues with respect to the photons and electrons used in conventional radiotherapy. Heavy (Z > 1) PT beams can additionally be exploited for their high biological effectiveness in killing cancer cells. Nowadays, protons and carbon ions are used in PT clinical routines. Recently, interest in the potential application of helium and oxygen beams has been growing. With respect to protons, such beams are characterized by their reduced multiple scattering inside the body, increased linear energy transfer, relative biological effectiveness and oxygen enhancement ratio. The precision of PT demands online dose monitoring techniques, crucial to improving the quality assurance of any treatment: possible patient mis-positioning and biological tissue changes with respect to the planning CT scan could negatively affect the outcome of the therapy. The beam range confined in the irradiated target can be monitored thanks to the neutral or charged secondary radiation emitted by the interactions of hadron beams with matter. Among these secondary products, prompt photons are produced by nuclear de-excitation processes, and at present, different dose monitoring and beam range verification techniques based on prompt-γ detection are being proposed. It is hence of importance to perform γ yield measurement in therapeutic-like conditions. In this paper we report on the yields of prompt photons produced by the interaction of helium, carbon and oxygen ion beams with a poly-methyl methacrylate (PMMA) beam stopping target. The measurements were performed at the Heidelberg Ion-Beam Therapy Center (HIT) with beams of different energies. An LYSO scintillator, placed at [Formula: see text] and [Formula: see text] with respect to the beam direction, was used as the photon detector. The obtained γ yields for the carbon ion beams are compared with results from the literature, while no other results from helium and oxygen beams have been published yet. A discussion on the expected resolution of a slit camera detector is presented, demonstrating the feasibility of a prompt-γ-based monitoring technique for PT treatments using helium, carbon and oxygen ion beams.


Asunto(s)
Radioterapia de Iones Pesados/métodos , Fotones , Polimetil Metacrilato/efectos de la radiación , Conteo por Cintilación/métodos , Carbono/química , Carbono/uso terapéutico , Radioterapia de Iones Pesados/efectos adversos , Radioterapia de Iones Pesados/normas , Helio/química , Helio/uso terapéutico , Humanos , Transferencia Lineal de Energía , Terapia de Protones , Efectividad Biológica Relativa , Conteo por Cintilación/instrumentación
7.
Phys Med Biol ; 62(4): 1291-1309, 2017 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-28114124

RESUMEN

Nowadays there is a growing interest in particle therapy treatments exploiting light ion beams against tumors due to their enhanced relative biological effectiveness and high space selectivity. In particular promising results are obtained by the use of 4He projectiles. Unlike the treatments performed using protons, the beam ions can undergo a fragmentation process when interacting with the atomic nuclei in the patient body. In this paper the results of measurements performed at the Heidelberg Ion-Beam Therapy center are reported. For the first time the absolute fluxes and the energy spectra of the fragments-protons, deuterons, and tritons-produced by 4He ion beams of 102, 125 and 145 MeV u-1 energies on a poly-methyl methacrylate target were evaluated at different angles. The obtained results are particularly relevant in view of the necessary optimization and review of the treatment planning software being developed for clinical use of 4He beams in clinical routine and the relative bench-marking of Monte Carlo algorithm predictions.


Asunto(s)
Helio/uso terapéutico , Fantasmas de Imagen , Polimetil Metacrilato/química , Monitoreo de Radiación/métodos , Programas Informáticos , Algoritmos , Humanos , Método de Montecarlo , Protones , Planificación de la Radioterapia Asistida por Computador , Efectividad Biológica Relativa
8.
Phys Med ; 32(9): 1139-44, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27601248

RESUMEN

PURPOSE: A radio-guided surgery technique with ß(-)-emitting radio-tracers was suggested to overcome the effect of the large penetration of γ radiation. The feasibility studies in the case of brain tumors and abdominal neuro-endocrine tumors were based on simulations starting from PET images with several underlying assumptions. This paper reports, as proof-of-principle of this technique, an ex vivo test on a meningioma patient. This test allowed to validate the whole chain, from the evaluation of the SUV of the tumor, to the assumptions on the bio-distribution and the signal detection. METHODS: A patient affected by meningioma was administered 300MBq of (90)Y-DOTATOC. Several samples extracted from the meningioma and the nearby Dura Mater were analyzed with a ß(-) probe designed specifically for this radio-guided surgery technique. The observed signals were compared both with the evaluation from the histology and with the Monte Carlo simulation. RESULTS: we obtained a large signal on the bulk tumor (105cps) and a significant signal on residuals of ∼0.2ml (28cps). We also show that simulations predict correctly the observed yields and this allows us to estimate that the healthy tissues would return negligible signals (≈1cps). This test also demonstrated that the exposure of the medical staff is negligible and that among the biological wastes only urine has a significant activity. CONCLUSIONS: This proof-of-principle test on a patient assessed that the technique is feasible with negligible background to medical personnel and confirmed that the expectations obtained with Monte Carlo simulations starting from diagnostic PET images are correct.


Asunto(s)
Neoplasias Encefálicas/radioterapia , Meningioma/radioterapia , Tomografía de Emisión de Positrones , Radiocirugia/métodos , Cirugía Asistida por Computador/métodos , Anciano , Algoritmos , Partículas beta , Neoplasias Encefálicas/diagnóstico por imagen , Simulación por Computador , Estudios de Factibilidad , Femenino , Humanos , Meningioma/diagnóstico por imagen , Modelos Teóricos , Método de Montecarlo , Exposición Profesional/prevención & control , Octreótido/análogos & derivados , Octreótido/química , Radiometría , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA