Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Clin Med ; 12(3)2023 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-36769866

RESUMEN

Transcatheter aortic valve implantation (TAVI) is the established first-line treatment for patient with severe aortic stenosis not suitable for surgery. Echocardiographic evaluation of hemodynamic forces (HDFs) is a growing field, holding the potential to early predict improvement in LV function. A prospective observational study was conducted. Transthoracic echocardiography was performed before and after TAVI. HDFs were analyzed along with traditional left ventricular (LV) function parameters. Twenty-five consecutive patients undergoing TAVI were enrolled: mean age 83 ± 5 years, 74.5% male, mean LV Ejection Fraction (LVEF) at baseline 57 ± 8%. Post-TAVI echocardiographic evaluation was performed 2.4 ± 1.06 days after the procedure. HDF amplitude parameters improved significantly after the procedure: LV Longitudinal Forces (LF) apex-base [mean difference (MD) 1.79%; 95% CI 1.07-2.5; p-value < 0.001]; LV systolic LF apex-base (MD 2.6%; 95% CI 1.57-3.7; p-value < 0.001); LV impulse (LVim) apex-base (MD 2.9%; 95% CI 1.48-4.3; p-value < 0.001). Similarly, HDFs orientation parameters improved: LVLF angle (MD 1.5°; 95% CI 0.07-2.9; p-value = 0.041); LVim angle (MD 2.16°; 95% CI 0.76-3.56; p-value = 0.004). Conversely, global longitudinal strain and LVEF did not show any significant difference before and after the procedure. Echocardiographic analysis of HDFs could help differentiate patients with LV function recovery after TAVI from patients with persistent hemodynamic dysfunction.

2.
J Cardiovasc Echogr ; 31(4): 246-247, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35284218

RESUMEN

A 55-year-old male with a history of severe organic mitral regurgitation treated with surgical mitral valve (MV) repair was referred for a transcatheter MV replacement due to recurrent regurgitation. After the release of the first transcatheter MV, a severe paravalvular leak coming from the lateral side was observed. To promptly tackle this issue, a second valve with further postdilation was successfully implanted and the paravalvular leak disappeared. This case highlights the feasibility of implanting a second valve in case of severe paravalvular leaks after MV-in-ring procedures due to device malapposition.

3.
Multimed Man Cardiothorac Surg ; 2005(1129): mmcts.2004.001008, 2005 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-24415219

RESUMEN

The internal mammary artery (IMA) has been already used in some pioneering experiences since the middle of last century but it became the graft of choice only in the 1980s, after widespread angiographic and clinical demonstration of its superiority over the saphenous vein graft (SVG). The use of both mammary arteries was then explored in order to achieve better long-term results when compared to single IMA and SVG. The IMA can be harvested pedicled or skeletonized and used as an in situ graft or as a source for composite graft (Y-graft, lengthened graft). When the bilateral internal mammary artery (BIMA) is grafted in situ, the left internal mammary artery (LIMA) is generally used for the left descending artery (LAD) and the RIMA for the right coronary artery (RCA), or for the lateral wall, usually going through the transverse sinus. In the case of Y-graft, the left coronary system is more frequently chosen as the target site of revascularization. Our experience shows that: (1) The use of IMA provides better 15-year clinical results when compared to SVG. (2) The use of BIMA in patients younger than 75 years can produce higher 10-year freedom from cardiac-related events than the single one, even in diabetic patients.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA