Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Chem Rev ; 122(4): 4636-4699, 2022 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-35077645

RESUMEN

Bioelectronic transducing surfaces that are nanometric in size have been the main route to detect single molecules. Though enabling the study of rarer events, such methodologies are not suited to assay at concentrations below the nanomolar level. Bioelectronic field-effect-transistors with a wide (µm2-mm2) transducing interface are also assumed to be not suited, because the molecule to be detected is orders of magnitude smaller than the transducing surface. Indeed, it is like seeing changes on the surface of a one-kilometer-wide pond when a droplet of water falls on it. However, it is a fact that a number of large-area transistors have been shown to detect at a limit of detection lower than femtomolar; they are also fast and hence innately suitable for point-of-care applications. This review critically discusses key elements, such as sensing materials, FET-structures, and target molecules that can be selectively assayed. The amplification effects enabling extremely sensitive large-area bioelectronic sensing are also addressed.


Asunto(s)
Técnicas Biosensibles , Transistores Electrónicos , Técnicas Biosensibles/métodos , Nanotecnología
2.
Small ; 18(26): e2108077, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35642950

RESUMEN

Organic electrochemical transistors (OECTs) rely on volumetric ion-modulation of the electronic current to provide low-voltage operation, large signal amplification, enhanced sensing capabilities, and seamless integration with biology. The majority of current OECT technologies require multistep photolithographic microfabrication methods on glass or plastic substrates, which do not provide an ideal path toward ultralow cost ubiquitous and sustainable electronics and bioelectronics. At the same time, the development of advanced bioelectronic circuits combining bio-detection, amplification, and local processing functionalities urgently demand for OECT technology platforms with a monolithic integration of high-performance iontronic circuits and sensors. Here, fully printed mask-less OECTs fabricated on thin-film biodegradable and compostable substrates are proposed. The dispensing and capillary printing methods are used for depositing both high- and low-viscosity OECT materials. Fully printed OECT unipolar inverter circuits with a gain normalized to the supply voltage as high as 136.6 V-1 , and current-driven sensors for ion detection and real-time monitoring with a sensitivity of up to 506 mV dec-1 , are integrated on biodegradable and compostable substrates. These universal building blocks with the top-performance ever reported demonstrate the effectiveness of the proposed approach and can open opportunities for next-generation high-performance sustainable bioelectronics.


Asunto(s)
Técnicas Biosensibles , Transistores Electrónicos , Técnicas Biosensibles/métodos , Electrónica
3.
Anal Bioanal Chem ; 414(18): 5657-5669, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35410389

RESUMEN

Early diagnosis in a premalignant (or pre-invasive) state represents the only chance for cure in neoplastic diseases such as pancreatic-biliary cancer, which are otherwise detected at later stages and can only be treated using palliative approaches, with no hope for a cure. Screening methods for the purpose of secondary prevention are not yet available for these cancers. Current diagnostic methods mostly rely on imaging techniques and conventional cytopathology, but they do not display adequate sensitivity to allow valid early diagnosis. Next-generation sequencing can be used to detect DNA markers down to the physical limit; however, this assay requires labeling and is time-consuming. The additional determination of a protein marker that is a predictor of aggressive behavior is a promising innovative approach, which holds the potential to improve diagnostic accuracy. Moreover, the possibility to detect biomarkers in blood serum offers the advantage of a noninvasive diagnosis. In this study, both the DNA and protein markers of pancreatic mucinous cysts were analyzed in human blood serum down to the single-molecule limit using the SiMoT (single-molecule assay with a large transistor) platform. The SiMoT device proposed herein, which exploits an inkjet-printed organic semiconductor on plastic foil, comprises an innovative 3D-printed sensing gate module, consisting of a truncated cone that protrudes from a plastic substrate and is compatible with standard ELISA wells. This 3D gate concept adds tremendous control over the biosensing system stability, along with minimal consumption of the capturing molecules and body fluid samples. The 3D sensing gate modules were extensively characterized from both a material and electrical perspective, successfully proving their suitability as detection interfaces for biosensing applications. KRAS and MUC1 target molecules were successfully analyzed in diluted human blood serum with the 3D sensing gate functionalized with b-KRAS and anti-MUC1, achieving a limit of detection of 10 zM and 40 zM, respectively. These limits of detection correspond to (1 ± 1) KRAS and (2 ± 1) MUC1 molecules in the 100 µL serum sample volume. This study provides a promising application of the 3D SiMoT platform, potentially facilitating the timely, noninvasive, and reliable identification of pancreatic cancer precursor cysts.


Asunto(s)
Quiste Pancreático , Proteínas Proto-Oncogénicas p21(ras) , Biomarcadores , Humanos , Quiste Pancreático/diagnóstico , Quiste Pancreático/metabolismo , Quiste Pancreático/patología , Neoplasias Pancreáticas , Plásticos , Impresión Tridimensional , Neoplasias Pancreáticas
4.
Chem Soc Rev ; 49(21): 7627-7670, 2020 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-33016288

RESUMEN

While organic materials have demonstrated industry-leading performances in a wide array of electronic applications (including OLEDs and OPVs), their use for integration into electronic circuits has been so far limited, in spite of their potential for portable, flexible, light-weight, low-cost applications. However, recent advances in organic (semi)conductors and novel designs in organic field-effect transistors and hybrid systems have reaffirmed the potential of organic logic circuits. This review article provides an overview of organic-based inverter operation and considers all aspects of such circuits including their active layer, processing methods, hybrid organic/inorganic inverters, novel architectures and potential applications.

5.
Adv Mater ; 36(13): e2309705, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38108547

RESUMEN

Screening asymptomatic organisms (humans, animals, plants) with a high-diagnostic accuracy using point-of-care-testing (POCT) technologies, though still visionary holds great potential. Convenient surveillance requires easy-to-use, cost-effective, ultra-portable but highly reliable, in-vitro-diagnostic devices that are ready for use wherever they are needed. Currently, there are not yet such devices available on the market, but there are a couple more promising technologies developed at readiness-level 5: the Clustered-Regularly-Interspaced-Short-Palindromic-Repeats (CRISPR) lateral-flow-strip tests and the Single-Molecule-with-a-large-Transistor (SiMoT) bioelectronic palmar devices. They both hold key features delineated by the World-Health-Organization for POCT systems and an occurrence of false-positive and false-negative errors <1-5% resulting in diagnostic-selectivity and sensitivity >95-99%, while limit-of-detections are of few markers. CRISPR-strip is a molecular assay that, can detect down to few copies of DNA/RNA markers in blood while SiMoT immunometric and molecular test can detect down to a single oligonucleotide, protein marker, or pathogens in 0.1mL of blood, saliva, and olive-sap. These technologies can prospectively enable the systematic and reliable surveillance of asymptomatic ones prior to worsening/proliferation of illnesses allowing for timely diagnosis and swift prognosis. This could establish a proactive healthcare ecosystem that results in effective treatments for all living organisms generating diffuse and well-being at efficient costs.


Asunto(s)
Sistemas CRISPR-Cas , Salud Única , Animales , Humanos , Sistemas de Atención de Punto , ARN
6.
Nat Commun ; 15(1): 5350, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38914568

RESUMEN

Organic artificial neurons operating in liquid environments are crucial components in neuromorphic bioelectronics. However, the current understanding of these neurons is limited, hindering their rational design and development for realistic neuronal emulation in biological settings. Here we combine experiments, numerical non-linear simulations, and analytical tools to unravel the operation of organic artificial neurons. This comprehensive approach elucidates a broad spectrum of biorealistic behaviors, including firing properties, excitability, wetware operation, and biohybrid integration. The non-linear simulations are grounded in a physics-based framework, accounting for ion type and ion concentration in the electrolytic medium, organic mixed ionic-electronic parameters, and biomembrane features. The derived analytical expressions link the neurons spiking features with material and physical parameters, bridging closer the domains of artificial neurons and neuroscience. This work provides streamlined and transferable guidelines for the design, development, engineering, and optimization of organic artificial neurons, advancing next generation neuronal networks, neuromorphic electronics, and bioelectronics.


Asunto(s)
Electrónica , Modelos Neurológicos , Neuronas , Neuronas/fisiología , Electrónica/instrumentación , Potenciales de Acción/fisiología , Redes Neurales de la Computación
7.
Adv Sci (Weinh) ; 11(27): e2308141, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38234100

RESUMEN

Pancreatic cancer, ranking as the third factor in cancer-related deaths, necessitates enhanced diagnostic measures through early detection. In response, SiMoT-Single-molecule with a large Transistor multiplexing array, achieving a Technology Readiness Level of 5, is proposed for a timely identification of pancreatic cancer precursor cysts and is benchmarked against the commercially available chemiluminescent immunoassay SIMOA (Single molecule array) SP-X System. A cohort of 39 samples, comprising 33 cyst fluids and 6 blood plasma specimens, undergoes detailed examination with both technologies. The SiMoT array targets oncoproteins MUC1 and CD55, and oncogene KRAS, while the SIMOA SP-X planar technology exclusively focuses on MUC1 and CD55. Employing Principal Component Analysis (PCA) for multivariate data processing, the SiMoT array demonstrates effective discrimination of malignant/pre-invasive high-grade or potentially malignant low-grade pancreatic cysts from benign non-mucinous cysts. Conversely, PCA analysis applied to SIMOA assay reveals less effective differentiation ability among the three cyst classes. Notably, SiMoT unique capability of concurrently analyzing protein and genetic markers with the threshold of one single molecule in 0.1 mL positions it as a comprehensive and reliable diagnostic tool. The electronic response generated by the SiMoT array facilitates direct digital data communication, suggesting potential applications in the development of field-deployable liquid biopsy.


Asunto(s)
Quiste Pancreático , Neoplasias Pancreáticas , Quiste Pancreático/diagnóstico , Quiste Pancreático/patología , Humanos , Inmunoensayo/métodos , Neoplasias Pancreáticas/diagnóstico , Mediciones Luminiscentes/métodos , Biomarcadores de Tumor/genética , Sensibilidad y Especificidad , Análisis de Componente Principal/métodos , Proteínas Proto-Oncogénicas p21(ras)/genética
8.
Adv Mater ; 35(42): e2304102, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37452695

RESUMEN

A cohort of 47 patients is screened for pancreatic cancer precursors with a portable 96-well bioelectronic sensing-array for single-molecule assay in cysts fluid and blood plasma, deployable at point-of-care (POC). Pancreatic cancer precursors are mucinous cysts diagnosed with a sensitivity of at most 80% by state-of-the-art cytopathological molecular analyses (e.g., KRASmut DNA). Adding the simultaneous assay of proteins related to malignant transformation (e.g., MUC1 and CD55) is deemed essential to enhance diagnostic accuracy. The bioelectronic array proposed here, based on single-molecule-with-a-large-transistor (SiMoT) technology, can assay both nucleic acids and proteins at the single-molecule limit-of-identification (LOI) (1% of false-positives and false-negatives). It comprises an enzyme-linked immunosorbent assay (ELISA)-like 8 × 12-array organic-electronics disposable cartridge with an electrolyte-gated organic transistor sensor array, and a reusable reader, integrating a custom Si-IC chip, operating via software installed on a USB-connected smart device. The cartridge is complemented by a 3D-printed sensing gate cover plate. KRASmut , MUC1, and CD55 biomarkers either in plasma or cysts-fluid from 5 to 6 patients at a time, are multiplexed at single-molecule LOI in 1.5 h. The pancreatic cancer precursors are classified via a machine-learning analysis resulting in at least 96% diagnostic-sensitivity and 100% diagnostic-specificity. This preliminary study opens the way to POC liquid-biopsy-based early diagnosis of pancreatic-cancer precursors in plasma.


Asunto(s)
Quistes , Neoplasias Pancreáticas , Humanos , Proteínas Proto-Oncogénicas p21(ras)/genética , Detección Precoz del Cáncer , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/genética , Neoplasias Pancreáticas/metabolismo , Neoplasias Pancreáticas
9.
ACS Appl Mater Interfaces ; 14(50): 56363-56373, 2022 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-36475583

RESUMEN

Poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) has been recently proposed for Raman sensing of redox-active species in solution. Here, we investigated the rationale of this approach through systematic experiments, in which the Raman spectrum of PEDOT:PSS was analyzed in the presence of either nonoxidizing or oxidizing electrolytes. The results demonstrated that Raman spectra precisely reflect the conformation of PEDOT units and their interactions with PSS. Two different responses were observed. In the case of oxidizing electrolytes, the effect of charge transfer is accurately transduced in Raman spectrum changes. On the other hand, reduction induces a progressive separation between the PEDOT and PSS chains, which decreases their mutual interaction. This stimulus determines characteristic variations in the intensity, shape, and position of the Raman spectra. However, we demonstrated that the same effects can be obtained either by increasing the concentration of nonoxidizing electrolytes or by deprotonating PSS chains. This poses severe limitations to the use of PEDOT:PSS for this type of Raman sensing. This study allows us to revise most of the Raman results reported in the literature with a clear model, setting a new basis for investigating the dynamics of mixed electronic/ionic charge transfer in conductive polymers.

10.
Adv Sci (Weinh) ; 9(20): e2104381, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35522000

RESUMEN

Single-molecule detection at a nanometric interface in a femtomolar solution, can take weeks as the encounter rate between the diffusing molecule to be detected and the transducing nanodevice is negligibly small. On the other hand, several experiments prove that macroscopic label-free sensors based on field-effect-transistors, engaging micrometric or millimetric detecting interfaces are capable to assay a single-molecule in a large volume within few minutes. The present work demonstrates why at least a single molecule out of a few diffusing in a 100 µL volume has a high probability to hit a large capturing and detecting electronic interface. To this end, sensing data, measured with an electrolyte-gated FET whose gate is functionalized with 1012 capturing anti-immunoglobulin G, are here provided along with a Brownian diffusion-based modeling. The EG-FET assays solutions down to some tens of zM in concentrations with volumes ranging from 25 µL to 1 mL in which the functionalized gates are incubated for times ranging from 30 s to 20 min. The high level of accordance between the experimental data and a model based on the Einstein's diffusion-theory proves how the single-molecule detection process at large-capturing interfaces is controlled by Brownian diffusion and yet is highly probable and fast.


Asunto(s)
Técnicas Biosensibles , Transistores Electrónicos , Electrólitos , Electrónica , Nanotecnología
11.
Sci Adv ; 8(27): eabo0881, 2022 07 08.
Artículo en Inglés | MEDLINE | ID: mdl-35857467

RESUMEN

Molecular tests are highly reliable and sensitive but lack portability and are not simple to use; conversely, easy-to-use antigenic tests still lack high performance. BioScreen combines single-molecule sensitivity and outstanding reliability with ultraportability and simplicity of use. This digital platform is capable of artificial intelligence-based binary classification at the limit of identification of a single marker/virus in 0.1 ml. The diagnostic sensitivity, specificity, and accuracy reach 99.2% as validated through 240 assays, including a pilot clinical trial. The versatile immunometric system can detect the SARS-CoV-2 virus, spike S1, and immunoglobulin G antigen proteins in saliva, blood serum, and swab. BioScreen has a small footprint comprising a disposable cartridge and a handheld electronic reader connected to a smart device. The sample handling is minimal, and the assay time to result is 21 min. Reliable and sensitive self-testing with an ultraportable and easy-to-use diagnostic system operated directly by a patient holds the potential to revolutionize point-of-care testing and early diagnosis.


Asunto(s)
COVID-19 , SARS-CoV-2 , Inteligencia Artificial , COVID-19/diagnóstico , Humanos , Pruebas en el Punto de Atención , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
12.
ACS Nano ; 15(11): 17769-17779, 2021 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-34767355

RESUMEN

Two-dimensional layered transition metal dichalcogenides (TMDs) have been investigated intensively as next-generation semiconducting materials. However, conventional TMD-based devices exhibit large contact resistance at the interface between the TMD and the metal electrode because of Fermi level pinning and the Schottky barrier, which results in poor charge injection. Here, we present enhanced charge transport characteristics in molybdenum diselenide (MoSe2) by means of a sequential engineering process called PESOD-2H/1T (i.e., phase transition engineering combined with surface transfer organic cationic dye doping; 2H and 1T represent the trigonal prismatic and octahedral phases, respectively). Substantial improvements are observed in PESOD-processed MoSe2 phototransistors, specifically, an approximately 40 000-fold increase in effective carrier mobility and a 100 000-fold increase in photoresponsivity, compared with the mobility and photoresponsivity of intact MoSe2 phototransistors. Moreover, the PESOD-processed MoSe2 phototransistor on a flexible substrate maintains its optoelectronic properties under tensile stress, with a bending radius of 5 mm.

13.
Adv Healthc Mater ; 10(19): e2100845, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34309226

RESUMEN

In this progress report an overview is given on the use of the organic electrochemical transistor (OECT) as a biosensor for impedance sensing of cell layers. The transient OECT current can be used to detect changes in the impedance of the cell layer, as shown by Jimison et al. To circumvent the application of a high gate bias and preventing electrolysis of the electrolyte, in case of small impedance variations, an alternative measuring technique based on an OECT in a current-driven configuration is developed. The ion-sensitivity is larger than 1200 mV V-1 dec-1 at low operating voltage. It can be even further enhanced using an OECT based complementary amplifier, which consists of a p-type and an n-type OECT connected in series, as known from digital electronics. The monitoring of cell layer integrity and irreversible disruption of barrier function with the current-driven OECT is demonstrated for an epithelial Caco-2 cell layer, showing the enhanced ion-sensitivity as compared to the standard OECT configuration. As a state-of-the-art application of the current-driven OECT, the in situ monitoring of reversible tight junction modulation under the effect of drug additives, like poly-l-lysine, is discussed. This shows its potential for in vitro and even in vivo toxicological and drug delivery studies.


Asunto(s)
Técnicas Biosensibles , Transistores Electrónicos , Células CACO-2 , Impedancia Eléctrica , Electrólitos , Humanos
14.
Biosensors (Basel) ; 11(6)2021 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-34204930

RESUMEN

The early detection of the human immunodeficiency virus (HIV) is of paramount importance to achieve efficient therapeutic treatment and limit the disease spreading. In this perspective, the assessment of biosensing assay for the HIV-1 p24 capsid protein plays a pivotal role in the timely and selective detection of HIV infections. In this study, multi-parameter-SPR has been used to develop a reliable and label-free detection method for HIV-1 p24 protein. Remarkably, both physical and chemical immobilization of mouse monoclonal antibodies against HIV-1 p24 on the SPR gold detecting surface have been characterized for the first time. The two immobilization techniques returned a capturing antibody surface coverage as high as (7.5 ± 0.3) × 1011 molecule/cm2 and (2.4 ± 0.6) × 1011 molecule/cm2, respectively. However, the covalent binding of the capturing antibodies through a mixed self-assembled monolayer (SAM) of alkanethiols led to a doubling of the p24 binding signal. Moreover, from the modeling of the dose-response curve, an equilibrium dissociation constant KD of 5.30 × 10-9 M was computed for the assay performed on the SAM modified surface compared to a much larger KD of 7.46 × 10-5 M extracted for the physisorbed antibodies. The chemically modified system was also characterized in terms of sensitivity and selectivity, reaching a limit of detection of (4.1 ± 0.5) nM and an unprecedented selectivity ratio of 0.02.


Asunto(s)
Bioensayo/métodos , Proteína p24 del Núcleo del VIH , Resonancia por Plasmón de Superficie , Técnicas Biosensibles , Oro/química , VIH-1 , Límite de Detección
15.
Sci Adv ; 7(50): eabl5068, 2021 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-34890232

RESUMEN

In living organisms, sensory and motor processes are distributed, locally merged, and capable of forming dynamic sensorimotor associations. We introduce a simple and efficient organic neuromorphic circuit for local sensorimotor merging and processing on a robot that is placed in a maze. While the robot is exposed to external environmental stimuli, visuomotor associations are formed on the adaptable neuromorphic circuit. With this on-chip sensorimotor integration, the robot learns to follow a path to the exit of a maze, while being guided by visually indicated paths. The ease of processability of organic neuromorphic electronics and their unconventional form factors, in combination with education-purpose robotics, showcase a promising approach of an affordable, versatile, and readily accessible platform for exploring, designing, and evaluating behavioral intelligence through decentralized sensorimotor integration.

16.
Artículo en Inglés | MEDLINE | ID: mdl-35475166

RESUMEN

Electrolyte-gated transistors (EGTs), capable of transducing biological and biochemical inputs into amplified electronic signals and stably operating in aqueous environments, have emerged as fundamental building blocks in bioelectronics. In this Primer, the different EGT architectures are described with the fundamental mechanisms underpinning their functional operation, providing insight into key experiments including necessary data analysis and validation. Several organic and inorganic materials used in the EGT structures and the different fabrication approaches for an optimal experimental design are presented and compared. The functional bio-layers and/or biosystems integrated into or interfaced to EGTs, including self-organization and self-assembly strategies, are reviewed. Relevant and promising applications are discussed, including two-dimensional and three-dimensional cell monitoring, ultra-sensitive biosensors, electrophysiology, synaptic and neuromorphic bio-interfaces, prosthetics and robotics. Advantages, limitations and possible optimizations are also surveyed. Finally, current issues and future directions for further developments and applications are discussed.

17.
Nat Commun ; 11(1): 3743, 2020 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-32719350

RESUMEN

Ions are ubiquitous biological regulators playing a key role for vital processes in animals and plants. The combined detection of ion concentration and real-time monitoring of small variations with respect to the resting conditions is a multiscale functionality providing important information on health states. This multiscale functionality is still an open challenge for current ion sensing approaches. Here we show multiscale real-time and high-sensitivity ion detection with complementary organic electrochemical transistors amplifiers. The ion-sensing amplifier integrates in the same device both selective ion-to-electron transduction and local signal amplification demonstrating a sensitivity larger than 2300 mV V-1 dec-1, which overcomes the fundamental limit. It provides both ion detection over a range of five orders of magnitude and real-time monitoring of variations two orders of magnitude lower than the detected concentration, viz. multiscale ion detection. The approach is generally applicable to several transistor technologies and opens opportunities for multifunctional enhanced bioelectronics.


Asunto(s)
Amplificadores Electrónicos , Sistemas de Computación , Técnicas Electroquímicas/instrumentación , Técnicas Electroquímicas/métodos , Iones/análisis , Compuestos Orgánicos/química , Transistores Electrónicos , Electricidad , Humanos , Iones/sangre , Potasio/análisis
18.
ACS Sens ; 5(6): 1822-1830, 2020 06 26.
Artículo en Inglés | MEDLINE | ID: mdl-32495625

RESUMEN

The increasing interest in technologies capable of tracking a biomarker down to the physical limit points toward new opportunities in early diagnostics of progressive diseases. Indeed, single-molecule detection technologies are foreseen to enable clinicians to associate the tiniest increase in a biomarker with the progression of a disease, particularly at its early stage. Bioelectronic organic transistors represent an extremely powerful tool to achieve label-free and single-molecule detection of clinically relevant biomarkers. These electronic devices are millimetric in size and in the future could be mass-produced at low cost. The core of the single molecule with a large transistor (SiMoT) platform, based on an electrolyte-gated field-effect transistor, is a gold gate electrode biofunctionalized with a self-assembled monolayer, a densely packed layer of recognition elements. So far, only the SiMoT detection of proteins, using the corresponding antibodies as recognition elements, has been reported. In this study, the SiMoT sensing response toward genomic biomarkers is proposed. Herein, the gate is functionalized with a genomic biomarker for multiple sclerosis (miR-182). This is relevant, not only because a limit of detection of a single molecule is achieved but also because it proves that the SiMoT label-free, single-molecule detection principle is the only one of its kind that can detect, by means of the same platform, both protein and genomic markers.


Asunto(s)
Técnicas Biosensibles , Transistores Electrónicos , Biomarcadores , Genómica , Nanotecnología
19.
Nat Commun ; 10(1): 3044, 2019 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-31292452

RESUMEN

Organic electrochemical transistors rely on ionic-electronic volumetric interaction to provide a seamless interface between biology and electronics with outstanding signal amplification. Despite their huge potential, further progress is limited owing to the lack of understanding of the device fundamentals. Here, we investigate organic electrochemical transistors in a wide range of experimental conditions by combining electrical analyses and device modeling. We show that the measurements can be quantitatively explained by nanoscale ionic-electronic charge interaction, giving rise to ion buffering and interface charge compensation. The investigation systematically explains and unifies a wide range of experiments, providing the rationale for the development of high-performance electronics. Unipolar inverters - universal building blocks for electronics - with gain larger than 100 are demonstrated. This is the highest gain ever reported, enabling the design of devices and circuits with enhanced performance and opening opportunities for the next-generation integrated bioelectronics and neuromorphic computing.

20.
Adv Healthc Mater ; 8(16): e1900128, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31318183

RESUMEN

The integrity of CaCo-2 cell barriers is investigated by organic electrochemical transistors (OECTs) in a current-driven configuration. Ion transport through cellular barriers via the paracellular pathway is modulated by tight junctions between adjacent cells. Rupturing its integrity by H2 O2 is monitored by the change of the output voltage in the transfer characteristics. It is demonstrated that by operating the OECT in a current-driven configuration, the sensitive and temporal resolution for monitoring the cell barrier integrity is strongly enhanced as compared to the OECT transient response measurement. As a result, current-driven OECTs are useful tools to assess dynamic and critical changes in tight junctions, relevant for clinical applications as drug targeting and screening.


Asunto(s)
Electroquímica/métodos , Transistores Electrónicos , Técnicas Biosensibles/métodos , Células CACO-2 , Forma de la Célula/efectos de los fármacos , Humanos , Peróxido de Hidrógeno/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA