Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Environ Manage ; 326(Pt A): 116683, 2023 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-36370610

RESUMEN

Water stress is a current environmental menace mainly driven by over exploitation of aquifers, which is triggering poor water quality with high concentration of minerals in extracted groundwater. Particularly, silica is widespread in natural water supplies due to weathering processes of silicates occurring in contact with water, light, air, and other factors. However, due to groundwater over extraction the concentration of silica has increased during the last years in aquifer reservoirs from Aguascalientes State (México). In this context, it is very important to note that the removal of silica compounds from water is challenging and different methods can be used to avoid embedding problems in different industries. In the present work, the removal of reactive silica from synthetic solutions as well as from real wastewaters from an industrial anodizing process was studied using adsorption and chemical precipitation methods. Twelve commercial materials of different nature were used for adsorption tests, while seven precipitant agents were applied in the precipitation experiments. Adsorption tests were performed in batch systems with constant stirring at 30 °C and at different pH values (7 and 9). Precipitation experiments were carried out in batch systems and the best conditions for silica removal were found using an L9 orthogonal array of the Taguchi method employing molar ratio, pH of wastewater, stirring time and temperature as experimental factors. Adsorption results showed that Ferrolox (Iron (III) hydroxide-base adsorbent) was the most efficient sorbent for reactive silica removal from synthetic solutions and the anodizing wastewater. Also, the reactive silica adsorption was higher at pH 9 as compared to that measured at pH 7 and the adsorbed quantity at pH 9 was 16.22 and 11.25 mg/g for the synthetic solution and anodizing wastewater, respectively. According to molecular simulation, the main interaction between Ferrolox and silica species was related to the formation of hydroxo-complexes and to the interaction of Fe with oxygen of silica species. Additionally, magnesium chloride was the best precipitating reagent for reactive silica achieving up to 87% removal. According to ANOVA analysis of Taguchi method, pH was the most influential factor during the precipitation of reactive silica with a variance value of 81.42, while values lower than 3 were obtained for the rest of parameters. Overall, the present work is reporting for the first time the removal of reactive silica from anodizing wastewaters with promising results that can be implemented at full scale for water reclamation, which may significantly contribute to manage water reservoir in the region sustainably.


Asunto(s)
Contaminantes Químicos del Agua , Purificación del Agua , Adsorción , Aguas Residuales/análisis , Purificación del Agua/métodos , Dióxido de Silicio/química , Contaminantes Químicos del Agua/química , Concentración de Iones de Hidrógeno , Cinética
2.
J Environ Manage ; 284: 112024, 2021 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-33548751

RESUMEN

The presence of moderate concentrations of impurities in the nickel-plating baths generates failures on the coated pieces. This situation entails the necessity of replacing the electroplating bath, which implies the generation of large volumes of wastewater with metallic species and high quantity of sludge. For this reason, the adsorption of the principal impurities of nickel-plating baths of an industry was analyzed in this work. Particularly, the removal of Zn2+ was studied in more detail since the presence of this metal in the baths generates black spots on the coated pieces. Different commercial materials were used as adsorbents and Zn2+ adsorption studies were carried out using both standard solutions and industrial water from the nickel-plating baths. All the adsorption tests were performed in batch systems under constant agitation and the quantification of the impurities was made by ICP-MS analysis. The bone char (BC) was an efficient adsorbent for the removal of the principal impurities of nickel-plating baths. The use of molecular simulation tools helped to understand the preferences of the hydroxyapatite (the principal component of bone char) for different metallic ions present in the industrial waters. According to both the experimental adsorption and molecular simulation results, hydroxyl and phosphate groups of bone char are responsible of the adsorption of impurities of nickel-plating baths.


Asunto(s)
Aguas Residuales , Contaminantes Químicos del Agua , Adsorción , Baños , Galvanoplastia , Níquel/análisis , Contaminantes Químicos del Agua/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA