1.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38890126

RESUMEN

AIMS: Cardiac implantable electronic device (CIED) infections are a burden to hospitals and costly for healthcare systems. Chronic kidney disease (CKD) increases the risk of CIED infections, but its differential impact on healthcare utilization, costs, and outcomes is not known. METHODS AND RESULTS: This retrospective analysis used de-identified Medicare Fee-for-Service claims to identify patients implanted with a CIED from July 2016 to December 2020. Outcomes were defined as hospital days and costs within 12 months post-implant, post-infection CKD progression, and mortality. Generalized linear models were used to calculate results by CKD and infection status while controlling for other comorbidities, with differences between cohorts representing the incremental effect associated with CKD. A total of 584 543 patients had a CIED implant, of which 26% had CKD and 1.4% had a device infection. The average total days in hospital for infected patients was 23.5 days with CKD vs. 14.5 days (P < 0.001) without. The average cost of infection was $121 756 with CKD vs. $55 366 without (P < 0.001), leading to an incremental cost associated with CKD of $66 390. Infected patients with CKD were more likely to have septicaemia or severe sepsis than those without CKD (11.0 vs. 4.6%, P < 0.001). After infection, CKD patients were more likely to experience CKD progression (hazard ratio 1.26, P < 0.001) and mortality (hazard ratio 1.89, P < 0.001). CONCLUSION: Cardiac implantable electronic device infection in patients with CKD was associated with more healthcare utilization, higher cost, greater disease progression, and greater mortality compared to patients without CKD.


Asunto(s)
Desfibriladores Implantables , Progresión de la Enfermedad , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Insuficiencia Renal Crónica , Humanos , Insuficiencia Renal Crónica/terapia , Insuficiencia Renal Crónica/economía , Insuficiencia Renal Crónica/mortalidad , Masculino , Femenino , Desfibriladores Implantables/economía , Desfibriladores Implantables/efectos adversos , Estudios Retrospectivos , Anciano , Estados Unidos/epidemiología , Infecciones Relacionadas con Prótesis/economía , Infecciones Relacionadas con Prótesis/mortalidad , Marcapaso Artificial/economía , Marcapaso Artificial/efectos adversos , Marcapaso Artificial/estadística & datos numéricos , Anciano de 80 o más Años , Costos de la Atención en Salud/estadística & datos numéricos , Medicare/economía , Aceptación de la Atención de Salud/estadística & datos numéricos , Tiempo de Internación/estadística & datos numéricos , Tiempo de Internación/economía
2.
Eur Radiol ; 33(10): 6948-6958, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37195432

RESUMEN

OBJECTIVES: To evaluate at 1.5 and 3 T MRI the safety and performance of trademarked ENO®, TEO®, or OTO® pacing systems with automated MRI Mode and the image quality of non-enhanced MR examinations. METHODS: A total of 267 implanted patients underwent MRI examination (brain, cardiac, shoulder, cervical spine) at 1.5 (n = 126) or 3 T (n = 141). MRI-related device complications, lead electrical performances stability at 1-month post-MRI, proper functioning of the automated MRI mode and image quality were evaluated. RESULTS: Freedom from MRI-related complications at 1 month post-MRI was 100% in both 1.5 and 3 T arms (both p < 0.0001). The stability of pacing capture threshold was respectively at 1.5 and 3 T (atrial:: 98.9% (p = 0.001) and 100% (p < 0.0001); ventricular: both 100% (p < 0001)). The stability of sensing was respectively at 1.5 and 3 T (atrial: 100% (p = 0.0001) and 96.9% (p = 0.01); ventricular: 100% (p < 0.0001) and 99.1% (p = 0.0001)). All devices switched automatically to the programmed asynchronous mode in the MRI environment and to initially programmed mode after the MRI exam. While all MR examinations were assessed as interpretable, artifacts deteriorated a subset of examinations including mostly cardiac and shoulder ones. CONCLUSION: This study demonstrates the safety and electrical stability of ENO®, TEO®, or OTO® pacing systems at 1 month post-MRI at 1.5 and 3 T. Even if artifacts were noticed in a subset of examinations, overall interpretability was preserved. CLINICAL RELEVANCE STATEMENT: ENO®, TEO®, and OTO® pacing systems switch to MR-mode when detecting magnetic field and switch back on conventional mode after MRI. Their safety and electrical stability at 1 month post MRI were shown at 1.5 and 3 T. Overall interpretability was preserved. KEY POINTS: • Patients implanted with an MRI conditional cardiac pacemaker can be safely scanned under 1.5 or 3 Tesla MRI with preserved interpretability. • Electrical parameters of the MRI conditional pacing system remain stable after a 1.5 or 3 Tesla MRI scan. • The automated MRI mode enabled the automatic switch to asynchronous mode in the MRI environment and to initial settings after the MRI scan in all patients.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Humanos , Seguridad de Equipos/métodos , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos
3.
Med Clin (Barc) ; 146(10): 423-8, 2016 May 20.
Artículo en Español | MEDLINE | ID: mdl-26869206

RESUMEN

INTRODUCTION AND OBJECTIVES: Results of cardiac resynchronization therapy (CRT) have been extensively published. However, there is limited data in unselected populations. The objective of the study was to analyse the efficacy and safety of CRT in Catalonia. METHODS: A prospective study was performed of consecutive patients implanted with CRT over one year in 7 university hospitals in Catalonia, representing 90% of the implanted patients. Echocardiographic reverse remodelling was defined as 5 points improvement in left ventricular ejection fraction and clinical responders were defined as patients with an increase>10% of six-minute walk test or one point of New York Heart Association functional class at 12 months. Patients were followed up for one year and hospital admissions and mortality were analyzed. RESULTS: Of the 200 patients included in the study, 99% met the indications of the current CRT clinical guidelines and 68% received CRT with implantable cardioverter-defibrillator. The rate of complications was 12.5%. During follow-up 16 patients (8%) died. Fifty-two percent (104) of the population was considered to respond clinically and 62% (124) presented improved echocardiographic parameters. Compared to the year prior to implant, hospital admissions decreased by 82% (P<.001). CONCLUSIONS: In an unselected population of Catalonia, we observe that CRT was effective and decreased the number of hospital admissions.


Asunto(s)
Arritmias Cardíacas/terapia , Terapia de Resincronización Cardíaca , Anciano , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/mortalidad , Ecocardiografía , Femenino , Estudios de Seguimiento , Hospitalización/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , España , Análisis de Supervivencia , Resultado del Tratamiento