Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Herzschrittmacherther Elektrophysiol ; 32(2): 244-249, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33977306

RESUMEN

BACKGROUND: Three-dimensional mapping systems and the use of ultra-low dose radiation protocols have supported minimization of radiation dose during left atrial ablation procedures. By using optimal shielding, scattered radiation reaching the operator can be further reduced. This prospective study was designed to determine the remaining operator radiation exposure during left atrial catheter ablations using real-time dosimetry. METHODS: Radiation dose was recorded using real-time digital dosimetry badges outside the lead apron during 201 consecutive left atrial fibrillation ablation procedures. All procedures were performed using the same X­ray system (Siemens Healthineers Artis dBc; Siemens Healthcare AG, Erlangen, Germany) programmed with ultra-low dose radiation settings including a low frame rate (two frames per second), maximum copper filtration, and an optimized detector dose. To reduce scattered radiation to the operators, table-suspended lead curtains, ceiling-suspended leaded plastic shields, and radiation-absorbing shields on the patient were positioned in an overlapping configuration. RESULTS: The 201 procedures included 139 (69%) pulmonary vein isolations (PVI) (20 cryoballoon ablations, 119 radiofrequency ablations, with 35 cases receiving additional ablation of the cavotricuspid isthmus) and 62 (31%) PVI plus further left atrial substrate ablation. Mean radiation dose measured as dose area product for all procedures was 128.09 ± 187.87 cGy ∙ cm2 with a mean fluoroscopy duration of 9.4 ± 8.7 min. Real-time dosimetry showed very low average operator doses of 0.52 ± 0.10 µSv. A subanalysis of 51 (25%) procedures showed that the radiation burden for the operator was highest during pulmonary vein angiography. CONCLUSION: The use of ultra-low dose radiation protocols in combination with optimized shielding results in extremely low scattered radiation reaching the operator.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Fluoroscopía , Alemania , Humanos , Estudios Prospectivos , Venas Pulmonares/cirugía
2.
Int J Cardiol ; 243: 239-243, 2017 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-28592382

RESUMEN

BACKGROUND: After electrical cardioversion (eCV) in patients with atrial fibrillation (AF), the risk for clinically apparent cerebral thromboembolism is increased in the subsequent weeks. To date, there is little evidence on the incidence of acute brain lesions (ABL) detected with cerebral magnetic resonance imaging (MRI) after eCV, in particular in patients treated with the Non-Vitamin K Antagonist oral anticoagulants (NOAC). AIMS: The aim of this pilot study was to evaluate the incidence of MRI-detected ABL, as well as the neuro-cognitive function after eCV in patients with persistent AF using NOACs as compared to phenprocoumon. METHODS AND RESULTS: 50 consecutive patients with persistent AF (mean age 69.6±3.5years, 26 male) were evaluated in this prospective study. Cerebral 3Tesla MRI and neuro-cognitive assessment using the National Institutes of Health Stroke Scale (NIHSS) score and the Montreal Cognitive Assessment Test (MoCA) were performed in all patients within 24h before eCV and after a median follow-up duration of 14days (Q1: 13, Q3: 19days). Patients were treated with an OAC for at least 4weeks after eCV and according to the CHA2DS2-Vasc-score thereafter. Thirty-nine patients were treated with NOACs (Dabigatran 10/50 [20%], Apixaban 21/50 [42%] and Rivaroxaban 8/50 [16]) and 11/50 patients with Phenprocoumon (22%). No patient developed ABL on cerebral MRI at the 2-week follow-up. Neurological as well as cognitive function were similar before and 2weeks after eCV (NIHSS-score: p=0.35; MoCa score: p=0.21). CONCLUSION: Electrical CV in patients with persistent AF, in particular when treated with NOACs, carries a low risk for the development of MRI-detected ABL or neurocognitive decline. CLINICAL TRIALS REGISTRATION: GermanClinicalTrialsRegister number: DRKS00010460.


Asunto(s)
Anticoagulantes/uso terapéutico , Fibrilación Atrial/terapia , Encéfalo/diagnóstico por imagen , Cardioversión Eléctrica/tendencias , Imagen por Resonancia Magnética/tendencias , Pruebas de Estado Mental y Demencia , Anciano , Fibrilación Atrial/fisiopatología , Cardioversión Eléctrica/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Trastornos Neurocognitivos/diagnóstico por imagen , Trastornos Neurocognitivos/etiología , Trastornos Neurocognitivos/psicología , Proyectos Piloto , Estudios Prospectivos
3.
Herzschrittmacherther Elektrophysiol ; 26(3): 303-5, 2015 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-25990265

RESUMEN

This case report describes a 31-year-old man with a sustained wide complex tachycardia with left bundle brunch block morphology after surgical repair of a tetralogy of Fallot. The tachycardia was inducible after orciprenaline administration after ventricular stimulation with one extra beat. In combination with the three-dimensional electroanatomic mapping system and pace mapping technique the origin of the tachycardia was identified at the lateral free wall of the right ventricular outflow tract tachycardia (RVOT) inferior of the pulmonary valve. Successful radiofrequency ablation was performed and the patient is still free from ventricular tachycardia.


Asunto(s)
Procedimientos de Cirugía Plástica/efectos adversos , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Tetralogía de Fallot/cirugía , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/cirugía , Adulto , Humanos , Estudios Longitudinales , Masculino , Taquicardia Ventricular/diagnóstico , Tetralogía de Fallot/complicaciones , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/diagnóstico
4.
Herzschrittmacherther Elektrophysiol ; 26(2): 163-6, 2015 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-25801716

RESUMEN

In this article the cases of two female patients with heart failure (functional class III) and an intrinsic complete left bundle branch block are reported. Both patients have had an implanted cardioverter defibrillator (ICD) connected to a VDD lead for primary prevention of sudden cardiac death. Atrial sensing was good/acceptable with a physiological frequency histogram and normal PQ time. A system upgrade to cardiac resynchronization therapy device (CRT) was planned. The VDD lead was directly connected to the Bivent ICD. The follow up showed stable measurements and a high biventricular pacing rate. Thus, usage of VDD leads for atrial sensing in CRT seems to be possible in a selected patient population.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca/métodos , Electrocardiografía/instrumentación , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/prevención & control , Anciano , Electrocardiografía/métodos , Femenino , Atrios Cardíacos , Humanos , Persona de Mediana Edad , Resultado del Tratamiento
5.
ESC Heart Fail ; 2(3): 194-203, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27708856

RESUMEN

AIMS: Patients with heart failure (HF) commonly suffer from severe impairment of quality of life (QoL). One main goal of HF treatment is improvement of QoL. Physical well-being is an essential component of QoL. To enable assessment of physical well-being in HF patients, we validated the FEW16 questionnaire in a prospective study with patients from the Cardiac Insufficiency Bisoprolol Study in ELDerly. METHODS AND RESULTS: In 127 HF patients (age 73 ± 5.5 years, 72% male, 60% New York Heart Association class II, left ventricular ejection fraction 37 ± 8.5%), we measured physical well-being (FEW16), QoL [36-Item Short-Form Health Survey (SF36)], and depressive symptoms [PRIME MD Patient Health Questionnaire German short version for depression (PHQ-D)] at baseline and two follow-up visits, and correlated FEW16 scores with QoL data and clinical parameters. FEW16 mean scores are 3.04 ± 1.04 at baseline, 3.19 ± 0.94 after 3 months, and 2.77 ± 0.94 after 2-4 years. We assessed data quality, scale assumptions, and construct validity and reliability. Cronbach's alpha for subscales resilience: 0.84; ability to enjoy: 0.80; vitality: 0.88; inner peace: 0.87; total score: 0.95. Intraclass correlation coefficient (ICC) is 0.87 (95% CI 0.84-0.89, ICC (1.4). Pearson's correlations of FEW16 with SF36 and PHQ-D were significant. Six minutes walking distance and heart rate correlated significantly with the FEW16 total score. CONCLUSIONS: The FEW16 showed good reliability, internal consistency, and intraclass correlation. FEW16 scores correlated well with psychological and physical well-being (SF36) and clinical markers of exercise tolerance (6 min walk test and heart rate). Our results indicate a strong correlation of self-reported physical well-being with psychological factors. FEW16 values at baseline predicted the development of several aspects of QoL during beta-blocker up-titration.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA