Rev Sci Instrum ; 78(10): 103501, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17979413

RESUMEN

This article describes changes of optical properties of retroreflectors installed on the inner wall of the vacuum vessel of the Large Helical Device. They were made of stainless steel and were used for a CO(2) laser polarimeter. The reflectivity for a CO(2) laser beam dropped up to 40% after the start of glow discharge cleanings and main plasma experiments. Then it decreased gradually. The reflectivity in a wavelength range shorter than 10 mum decreased significantly through one experimental campaign (about 4 months). On the other hand the reflectivity in a wavelength range longer than 50 mum was larger than 70%. Decrease in the reflectivity in the central region of mirrors was more significant (the reflectivity for visible beams became almost zero) than that in the edge. The distribution of the reflectivity along the radial direction is expected to be related to the shape of the retroreflector. The parallelism of the reflected beam to an incident one also deteriorated. The changes in the polarization angle and in the ellipticity of reflected light polarization were not observed from the visible to the far infrared range.


Asunto(s)
Rayos Láser , Lentes , Óptica y Fotónica/instrumentación , Refractometría/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Refractometría/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Rev Sci Instrum ; 87(4): 043509, 2016 04.
Artículo en Inglés | MEDLINE | ID: mdl-27131676

RESUMEN

A flywheel motor-generator (MG) for the toroidal field (TF) coils of a small fusion device was developed which utilizes a commercially available squirrel-cage induction motor. Advantages of the MG are comparably-long duration, quick power response, and easy implementation of power control compared with conventional capacitor-type power supply. A 55-kW MG was fabricated, and TF coils of a small fusion device were energized. The duration of the current flat-top was extended to 1 s which is much longer than those of conventional small devices (around 10-100 ms).

3.
Rev Sci Instrum ; 83(10): 10E305, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126965

RESUMEN

Three-dimensional (3D) microwave imaging reflectometry has been developed in the large helical device to visualize fluctuating reflection surface which is caused by the density fluctuations. The plasma is illuminated by the probe wave with four frequencies, which correspond to four radial positions. The imaging optics makes the image of cut-off surface onto the 2D (7 × 7 channels) horn antenna mixer arrays. Multi-channel receivers have been also developed using micro-strip-line technology to handle many channels at reasonable cost. This system is first applied to observe the edge harmonic oscillation (EHO), which is an MHD mode with many harmonics that appears in the edge plasma. A narrow structure along field lines is observed during EHO.

4.
Rev Sci Instrum ; 81(10): 10D915, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033947

RESUMEN

A simultaneous projection/detection system of four different frequencies for microwave imaging reflectometry (MIR) was developed for three-dimensional observation of electron density fluctuations in the Large Helical Device (LHD). The microwave with four frequency components at 60.410, 61.808, 63.008, and 64.610 GHz is projected in a continuous-wave mode to illuminate the target LHD plasma. A two-dimensional horn-antenna mixer array (2D HMA) receives the reflected wave from the plasma as well as the wave from the local oscillator operating at 55.800 GHz. The first intermediate frequency (IF) signals at 4.610, 6.008, 7.208, and 8.810 GHz were confirmed to be obtained by downconversion of these microwaves using the 2D HMA. Each of these first IF components is filtered from each other and downconverted again for the superheterodyne detection. It was confirmed that both the amplitudes and the phases of the detected signals reflect the fluctuations in LHD plasmas.

5.
Rev Sci Instrum ; 81(10): 10D919, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033951

RESUMEN

A combined system of microwave imaging reflectometry and electron cyclotron emission (ECE) imaging has been developed for the Large Helical Device. This system includes a wide-band two-dimensional horn-antenna mixer array (HMA). The HMA consists of horn antennas, waveguides, mixers, and intermediate frequency circuits. The frequency response of the HMA is between 50 and 110 GHz. The ECE signal is selected using a 95 GHz local oscillator and a 93 GHz high-pass filter.