Circ J ; 81(9): 1272-1277, 2017 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-28428489

RESUMEN

BACKGROUND: Shocks delivered by implanted anti-tachyarrhythmia devices, even when appropriate, lower the quality of life and survival. The new SmartShock Technology®(SST) discrimination algorithm was developed to prevent the delivery of inappropriate shock. This prospective, multicenter, observational study compared the rate of inaccurate detection of ventricular tachyarrhythmia using the SST vs. a conventional discrimination algorithm.Methods and Results:Recipients of implantable cardioverter defibrillators (ICD) or cardiac resynchronization therapy defibrillators (CRT-D) equipped with the SST algorithm were enrolled and followed up every 6 months. The tachycardia detection rate was set at ≥150 beats/min with the SST algorithm. The primary endpoint was the time to first inaccurate detection of ventricular tachycardia (VT) with conventional vs. the SST discrimination algorithm, up to 2 years of follow-up. Between March 2012 and September 2013, 185 patients (mean age, 64.0±14.9 years; men, 74%; secondary prevention indication, 49.5%) were enrolled at 14 Japanese medical centers. Inaccurate detection was observed in 32 patients (17.6%) with the conventional, vs. in 19 patients (10.4%) with the SST algorithm. SST significantly lowered the rate of inaccurate detection by dual chamber devices (HR, 0.50; 95% CI: 0.263-0.950; P=0.034). CONCLUSIONS: Compared with previous algorithms, the SST discrimination algorithm significantly lowered the rate of inaccurate detection of VT in recipients of dual-chamber ICD or CRT-D.


Asunto(s)
Algoritmos , Desfibriladores Implantables , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/terapia , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
2.
Int Heart J ; 48(3): 323-36, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17592197

RESUMEN

BACKGROUND: The use of DDIR mode has been limited since the advent of mode switch in the DDDR mode. In patients with AV block, DDDR is necessary to maintain AV synchrony. However, DDIR mode may still be beneficial for patients with intact AV conduction. The aim of this study was to compare the incidence of ventricular pacing and atrial tachyarrhythmia in DDIR and DDDR with mode switch in a randomized, single-blind, crossover study, and discuss the utility of both modes. METHODS AND RESULTS: Twenty-four patients (8 males) with bradycardia-tachycardia syndrome and no signs of AV block (mean age 70.1 +/- -9.1 years) were enrolled and randomized to DDIR or DDDR modes with the leads placed at the right atrial appendage and right ventricular apex. After 12 weeks, patients were switched to the opposite mode. During the study period, atrial high rate episodes and other pacemaker diagnostic data were collected. Significantly less ventricular pacing was observed in DDIR mode (DDIR versus DDDR; 48.9%, 76.5%, P = 0.0002) and atrial high rate episodes were significantly lower in DDIR mode (DDIR versus DDDR; 1.32, 1.85 per day, P < 0.05). CONCLUSION: In patients with sinus node dysfunction and intact AV conduction, DDIR mode may have important implications for simplifying device programming, device longevity, and to avoid atrial tachyarrhythmia.


Asunto(s)
Arritmia Sinusal/terapia , Estimulación Cardíaca Artificial/métodos , Frecuencia Cardíaca/fisiología , Nodo Sinoatrial/fisiopatología , Anciano , Anciano de 80 o más Años , Arritmia Sinusal/fisiopatología , Estudios Cruzados , Progresión de la Enfermedad , Electrocardiografía Ambulatoria , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos , Humanos , Masculino , Persona de Mediana Edad , Método Simple Ciego , Resultado del Tratamiento