Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Radiology ; 305(2): 341-349, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35852428

RESUMEN

Background Changing iodinated contrast media (ICM) may reduce the risk of recurrent ICM-induced hypersensitivity reactions in patients with a prior reaction. Purpose To perform a systematic review on the effectiveness of ICM change in comparison with no change to prevent recurrent ICM immediate hypersensitivity reactions. Materials and methods Multiple data bases were searched without language restriction between January 1990 and August 2021 to identify comparative studies of any design that included patients with a prior ICM hypersensitivity reaction to low-osmolality ICM and re-exposure to intravascular ICM. The methods used included a duplicate assessment of eligibility, double extraction of quantitative data, validity assessment, and random-effects meta-analysis. The primary outcome was the incidence of all-grade immediate recurrent hypersensitivity reactions. Secondary outcomes were the incidence of severe immediate recurrent hypersensitivity reactions and other adverse events associated with ICM change. Results Six retrospective observational studies at moderate to severe risk of bias assessed 7155 adult patients (4329 in the ICM change group and 2826 in the no-change group). Studies adopted nonstandardized switching methods, and the proportions of the ICM change group ranged between 19% (five of 27 examinations) and 80% (3104 of 3880 examinations). A Bayesian meta-analysis revealed that changing ICM was associated with a reduced risk of recurrent hypersensitivity reaction by 61% (risk ratio = 0.39; 95% credible interval [CrI]: 0.24, 0.58). The wide-ranging estimates of risk reduction were not explained by the risk of bias ratings, the event rates in the no-change group, the index-reaction severity, or the co-administered nonstandard premedication. Rare severe recurrent reactions (five studies with five events) precluded a conclusion (risk ratio = 0.34, favoring ICM change; CrI: 0.01, 3.74). Adverse events associated with ICM change were not reported. Conclusion In observational evidence of limited quality, iodinated contrast media (ICM)-change was associated with a reduced risk of recurrent immediate hypersensitivity reaction in patients with a prior ICM-induced hypersensitivity reaction. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by McDonald in this issue.


Asunto(s)
Hipersensibilidad Inmediata , Hipersensibilidad , Compuestos de Yodo , Adulto , Humanos , Medios de Contraste/efectos adversos , Estudios Retrospectivos , Teorema de Bayes , Compuestos de Yodo/efectos adversos , Hipersensibilidad Inmediata/inducido químicamente , Hipersensibilidad/etiología
2.
Radiology ; 287(3): 1030-1040, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29533722

RESUMEN

Purpose To investigate the relationship between the postoperative prognosis of patients with part-solid non-small cell lung cancer and the solid component size acquired by using three-dimensional (3D) volumetry software on multidetector computed tomographic (CT) images. Materials and Methods A retrospective study by using preoperative multidetector CT data with 0.5-mm section thickness, clinical records, and pathologic reports of 96 patients with primary subsolid non-small cell lung cancer (47 men and 49 women; mean age ± standard deviation, 66 years ± 8) were reviewed. Two radiologists measured the two-dimensional (2D) maximal solid size of each nodule on an axial image (hereafter, 2D MSSA), the 3D maximal solid size on multiplanar reconstructed images (hereafter, 3D MSSMPR), and the 3D solid volume of greater than 0 HU (hereafter, 3D SV0HU) within each nodule. The correlations between the postoperative recurrence and the effects of clinical and pathologic characteristics, 2D MSSA, 3D MSSMPR, and 3D SV0HU as prognostic imaging biomarkers were assessed by using a Cox proportional hazards model. Results For the prediction of postoperative recurrence, the area under the receiver operating characteristics curve was 0.796 (95% confidence interval: 0.692, 0.900) for 2D MSSA, 0.776 (95% confidence interval: 0.667, 0.886) for 3D MSSMPR, and 0.835 (95% confidence interval: 0.749, 0.922) for 3D SV0HU. The optimal cutoff value for 3D SV0HU for predicting tumor recurrence was 0.54 cm3, with a sensitivity of 0.933 (95% confidence interval: 0.679, 0.998) and a specificity of 0.716 (95% confidence interval: 0.605, 0.811) for the recurrence. Significant predictive factors for disease-free survival were 3D SV0HU greater than or equal to 0.54 cm3 (hazard ratio, 6.61; P = .001) and lymphatic and/or vascular invasion derived from histopathologic analysis (hazard ratio, 2.96; P = .040). Conclusion The measurement of 3D SV0HU predicted the postoperative prognosis of patients with part-solid lung cancer more accurately than did 2D MSSA and 3D MSSMPR. © RSNA, 2018.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Imagenología Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Adulto , Anciano , Femenino , Humanos , Pulmón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Pronóstico , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
3.
BMJ Open ; 10(3): e033023, 2020 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-32156762

RESUMEN

INTRODUCTION: Iodinated contrast media are commonly used in medical imaging and can cause hypersensitivity reactions, including rare but severe life-threatening reactions. Although several prophylactic approaches have been proposed for severe reactions, their effects remain unclear. Therefore, we aim to review systematically the preventive effects of pharmacologic and non-pharmacologic interventions and predictors of acute, hypersensitivity reactions. METHODS AND ANALYSIS: We will search the PubMed, EMBASE and Cochrane Central Register of Controlled Trials databases from 1 January 1990 through 31 December 2019 and will examine the bibliographies of eligible studies, pertinent review articles and clinical practice guidelines. We will include prospective and retrospective studies of any design that evaluated the effects of pharmacological and non-pharmacological preventive interventions for adverse reactions of non-ionic iodinated contrast media. Two assessors will independently extract the characteristics of the study and intervention and the quantitative results. Two independent reviewers will assess the risk of bias using standard design-specific validity assessment tools. The primary outcome will be reduction in acute contrast media-induced hypersensitivity reactions. The secondary outcomes will include characteristics associated with the development of contrast media-induced acute hypersensitivity reactions, and adverse events associated with specific preventive interventions. Unique premedication regimens (eg, dose, drug and duration) and non-pharmacological strategies will be analysed separately. Average-risk and high-risk patients will be considered separately. A meta-analysis will be performed if appropriate. ETHICS AND DISSEMINATION: Ethics approval is not applicable, as this will be a secondary analysis of publicly available data. The results of the analysis will be submitted for publication in a peer reviewed journal. PROSPERO REGISTRATION NUMBER: CRD42019134003.


Asunto(s)
Medios de Contraste , Hipersensibilidad a las Drogas , Hipersensibilidad , Femenino , Humanos , Masculino , Medios de Contraste/efectos adversos , Hipersensibilidad a las Drogas/tratamiento farmacológico , Hipersensibilidad a las Drogas/inmunología , Hipersensibilidad a las Drogas/prevención & control , Hipersensibilidad/tratamiento farmacológico , Hipersensibilidad/inmunología , Hipersensibilidad/prevención & control , Premedicación/métodos , Estudios Prospectivos , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Retrospectivos , Revisiones Sistemáticas como Asunto
4.
Nagoya J Med Sci ; 81(1): 41-53, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30962654

RESUMEN

We evaluated the progression of interstitial lung disease (ILD) by three-dimensional curved high-resolution computed tomography (3D-cHRCT) at a constant depth from the chest wall and compare the results to pulmonary function test (PFT) results on a follow-up assessment. We reviewed the patients with ILD who underwent HRCT and concurrent PFTs at least twice from April 2008 to December 2014. Forty-five patients with ILD were enrolled. 3D-cHRCT images of the lung at various depths from the chest wall were reconstructed, and total area (TA), high-attenuation area (HAA) >-500 HU, and %HAA ([HAA/TA] × 100) were calculated. The TA, HAA, and %HAA ratios (follow-up to baseline) were assessed for use in the diagnosis of physiologically progressive ILD (defined as; forced vital capacity [FVC] ratio <0.9 or %diffusing capacity of the lung for carbon monoxide [%DLCO] ratio <0.85 [follow-up to baseline]). Of all ratios obtained from 3D-cHRCT images at 5-30mm depths, the %HAA ratio at 20-mm had the largest area under the receiver operating characteristic curve (0.815, 95 % confidence interval 0.677-0.953). By univariate logistic regression analysis, TA, HAA, and %HAA ratios at 20-mm showed significant correlations with physiologically progressive ILD. 3D-cHRCT imaging performed in parallel with the chest wall offers novel quantitative parameters that are useful for following ILD.


Asunto(s)
Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Enfermedades Pulmonares Intersticiales/diagnóstico , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Imagenología Tridimensional/métodos , Enfermedades Pulmonares Intersticiales/fisiopatología , Masculino , Persona de Mediana Edad , Capacidad de Difusión Pulmonar , Curva ROC , Pruebas de Función Respiratoria , Estudios Retrospectivos , Pared Torácica/diagnóstico por imagen , Pared Torácica/patología , Capacidad Vital/fisiología
5.
Cancer Imaging ; 19(1): 33, 2019 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-31174613

RESUMEN

BACKGROUND: For subsolid non-small cell lung cancers (NSCLCs), solid size (SS), which is the maximal diameter of the solid component, correlates more accurately with tumor prognosis than the total size, which is the maximal diameter of the entire tumor, including ground-glass opacity. We reviewed the propriety of the TNM staging based on the SS for early-stage NSCLCs. METHODS: We retrospectively reviewed the preoperative radiological reports, clinical records, and pathological reports of NSCLC cases in our hospital between 2010 and 2013, and clinical stage (c-Stage) 0 and I tumors were selected. Disease-free survival (DFS), based on survival analysis, was used to assess the tumor characteristics that predicted the prognosis. RESULTS: A total of 247 NSCLC diagnoses in 231 patients (88 women and 143 men; age, 67 ± 7 years) were included in our cohort. They were classified into solid (n = 131) and subsolid (n = 116) nodules. The DFS curves indicated that prognosis was significantly worse in the following order: c-Stage 0, c-Stage IA, and c-Stage IB tumors (p = 0.016). Patients with solid nodules showed a significantly worse prognosis than patients with subsolid nodules (p < 0.001). A multivariate Cox proportional hazards model showed that the significant predictive factors for DFS were c-Stage (hazard ratio, 1.600; p = 0.020) and solid nodules (hazard ratio, 3.077; p = 0.031). CONCLUSIONS: For early-stage NSCLCs, the c-Stage based on the SS in subsolid nodules was useful for predicting postoperative DFS. In addition, whether nodules were solid or subsolid was another independent prognostic factor.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/patología , Neoplasias Pulmonares/patología , Adulto , Anciano , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Femenino , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Análisis de Supervivencia , Tomografía Computarizada por Rayos X
6.
Jpn J Radiol ; 37(6): 437-448, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30891667

RESUMEN

PURPOSE: To determine whether functional near-infrared spectroscopy (fNIRS) allows monitoring fatigue in radiologists during prolonged image interpretation. MATERIALS AND METHODS: Nine radiologists participated as subjects in the present study and continuously interpreted medical images and generated reports for cases for more than 4 h under real clinical work conditions. We measured changes in oxygenated hemoglobin concentrations [oxy-Hb] in the prefrontal cortex using 16-channel fNIRS (OEG16ME, Spectratech) every hour during the Stroop task to evaluate fatigue of radiologists and recorded fatigue scale (FS) as a behavior data. RESULTS: Two subjects showed a subjective feeling of fatigue and an apparent decrease in brain activity after 4 h, so the experiment was completed in 4 h. The remaining seven subjects continued the experiment up to 5 h. FS decreased with time, and a significant reduction was observed between before and the end of image interpretation. Seven out of nine subjects showed a minimum [oxy-Hb] change at the end of prolonged image interpretation. The mean change of [oxy-Hb] at the end of all nine subjects was significantly less than the maximum during image interpretation. CONCLUSION: fNIRS using the change of [oxy-Hb] may be useful for monitoring fatigue in radiologists during image interpretation.


Asunto(s)
Fatiga/diagnóstico , Fatiga/metabolismo , Oxihemoglobinas/metabolismo , Corteza Prefrontal/metabolismo , Radiólogos/estadística & datos numéricos , Carga de Trabajo/estadística & datos numéricos , Adulto , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/estadística & datos numéricos , Masculino , Espectroscopía Infrarroja Corta , Test de Stroop , Tiempo , Carga de Trabajo/psicología , Adulto Joven
7.
Clin Lung Cancer ; 19(1): e37-e45, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28666761

RESUMEN

INTRODUCTION: We aimed to determine the concordance between the clinical stage (c-stage) and pathologic stage (p-stage) for patients with small-size lung cancer. Additionally we searched for prognostic factors other than the TNM stage. PATIENTS AND METHODS: We retrospectively reviewed the preoperative multidetector computed tomography (CT) and positron emission tomography/CT reports, surgical records, and pathologic reports of patients with primary lung cancer ≤ 3 cm. The Union for International Cancer Control TNM seventh edition classification of c-stage and p-stage were compared. The tumors were classified into multiple subgroups by concordance or discordance between the c-stage and p-stage. Disease-free survival (DFS) was assessed using survival analysis to assess the tumor characteristics that were predictive of prognosis. RESULTS: A total of 289 surgically resected primary lung cancers were evaluated. The concordance between c-stage and p-stage was 65.4%, with moderate reproducibility (kappa coefficient, 0.467). The upstaging rate from c-stage I to p-stage II-IV was 9.4%, and these patients had significantly worse DFS than those with a concordant stage I classification (P < .001). The main reason for upstaging was an underestimation of metastases to the hilar lymph nodes (n = 7) or mediastinal lymph nodes (n = 11). A multivariate Cox proportional hazards model showed that the significant predictive factors for DFS were p-stage (hazard ratio, 1.342; P = .003) and maximum standardized uptake value on positron emission tomography/CT (hazard ratio, 12.162; P = .001). CONCLUSION: The concordance rate between c-stage and p-stage for small primary lung cancers had moderate reproducibility. Discordance between c-stage I and p-stage II-IV significantly affected DFS. The maximum standardized uptake value of the primary lesion was an independent prognostic factor, and combining it with c-stage might improve the prediction of therapeutic outcomes.


Asunto(s)
Neoplasias Pulmonares/diagnóstico , Tomografía Computarizada Multidetector/métodos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Anciano , Femenino , Humanos , Neoplasias Pulmonares/mortalidad , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Periodo Posoperatorio , Valor Predictivo de las Pruebas , Pronóstico , Reproducibilidad de los Resultados , Estudios Retrospectivos , Análisis de Supervivencia
8.
PLoS One ; 12(9): e0185532, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28957390

RESUMEN

OBJECTIVES: To quantify the imaging findings of patients with interstitial pneumonia (IP) and emphysema using three-dimensional curved high-resolution computed tomography (3D-cHRCT) at a constant depth from the chest wall, and compare the results to visual assessment of IP and each patient's diffusing capacity of the lungs for carbon monoxide (DLco). METHODS: We retrospectively reviewed the axial CT findings and pulmonary function test results of 95 patients with lung cancer (72 men and 23 women, aged 45-84 years) with or without IP, as follows: non-IP (n = 47), mild IP (n = 31), and moderate IP (n = 17). The 3D-cHRCT images of the lung at a 1-cm depth from the chest wall were reconstructed automatically using original software; total area (TA), high-attenuation area (HAA) >-500 HU, and low-attenuation area (LAA) <-950 HU were calculated on a workstation. The %HAA and %LAA were calculated as follows: [Formula: see text], and [Formula: see text]. RESULTS: The %HAA and %LAA respective values were 3.2±0.9 and 27.7±8.2, 3.9±1.2 and 27.6±5.9, and 6.9±2.2 and 25.4±8.7 in non-IP, mild IP, and moderate IP patients, respectively. There were significant differences in %HAA between the 3 groups of patients (P<0.001), but no differences in %LAA (P = 0.558). Multiple linear regression analysis revealed that %HAA and %LAA were negatively correlated with predicted DLco (standard partial regression coefficient [b*] = -0.453, P<0.001; b* = -0.447, P<0.001, respectively). CONCLUSIONS: The %HAA and %LAA values computed using 3D-cHRCT were significantly correlated with DLco and may be important quantitative parameters for both IP and emphysema.


Asunto(s)
Imagenología Tridimensional , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Pared Torácica/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Proyectos Piloto
9.
Eur J Radiol ; 95: 186-191, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28987666

RESUMEN

PURPOSE: To compare dual-phase dual-energy CT (DE-CT) with FDG-PET/CT for predicting histopathological locoregional invasiveness of non-small cell lung cancers (NSCLCs). MATERIALS AND METHODS: We selected 63 consecutive patients with NSCLC lesions (37 males, 26 females; age range, 44-85 years; mean age, 69 years) who were evaluated preoperatively by both DE-CT and PET/CT at our institution. Postoperative microscopic invasiveness (lymphatic permeation, vascular invasion, and/or pleural involvement) was reviewed, and we defined locoregionally invasive tumors as those that had at least one positive finding of microscopic invasiveness. DE-CT scanning in the arterial and delayed phases was performed after injection of iodinated contrast media using 140-kVp and 80-kVp tube voltages. Three-dimensional iodine-related attenuation of primary tumors in the arterial and delayed phases was quantified automatically using "syngo Dual Energy Lung Nodules" application software, and the ratio of arterial phase to delayed phase enhancement (A/D ratio) was calculated. The A/D ratio and SUVmax on PET/CT were evaluated with respect to postoperative invasiveness by univariate logistic regression analysis. RESULTS: The A/D ratio was significantly correlated with lymphatic permeation, vascular invasion, and pleural involvement (p=0.011, p=0.021, and p=0.010, respectively). In contrast, the SUVmax was significantly correlated with pleural involvement (p=0.020) but not with lymphatic permeation or vascular invasion (p=0.088 and p=0.100, respectively). In the subgroup of patients with lesion diameters ≤2cm, the A/D ratio was significantly correlated with locoregional invasiveness (p=0.040), while the SUVmax was not (p=0.121). CONCLUSION: For the prediction of microscopic invasiveness of NSCLCs, the diagnostic performance of dual-phase DE-CT may be comparable to that of FDG-PET/CT.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Neoplasias Pulmonares/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma de Pulmón de Células no Pequeñas/patología , Femenino , Humanos , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Radiofármacos , Reproducibilidad de los Resultados
10.
PLoS One ; 12(1): e0170309, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28095493

RESUMEN

PURPOSE: We developed an original, computer-aided diagnosis (CAD) software that subtracts the initial thoracic vertebral three-dimensional computed tomography (3D-CT) image from the follow-up 3D-CT image. The aim of this study was to investigate the efficacy of this CAD software during screening for vertebral metastases on follow-up CT images of primary lung cancer patients. MATERIALS AND METHODS: The interpretation experiment included 30 sets of follow-up CT scans in primary lung cancer patients and was performed by two readers (readers A and B), who each had 2.5 years' experience reading CT images. In 395 vertebrae from C6 to L3, 46 vertebral metastases were identified as follows: osteolytic metastases (n = 17), osteoblastic metastases (n = 14), combined osteolytic and osteoblastic metastases (n = 6), and pathological fractures (n = 9). Thirty-six lesions were in the anterior component (vertebral body), and 10 lesions were in the posterior component (vertebral arch, transverse process, and spinous process). The area under the curve (AUC) by receiver operating characteristic (ROC) curve analysis and the sensitivity and specificity for detecting vertebral metastases were compared with and without CAD for each observer. RESULTS: Reader A detected 47 abnormalities on CT images without CAD, and 33 of them were true-positive metastatic lesions. Using CAD, reader A detected 57 abnormalities, and 38 were true positives. The sensitivity increased from 0.717 to 0.826, and on ROC curve analysis, AUC with CAD was significantly higher than that without CAD (0.849 vs. 0.902, p = 0.021). Reader B detected 40 abnormalities on CT images without CAD, and 36 of them were true-positive metastatic lesions. Using CAD, reader B detected 44 abnormalities, and 39 were true positives. The sensitivity increased from 0.783 to 0.848, and AUC with CAD was nonsignificantly higher than that without CAD (0.889 vs. 0.910, p = 0.341). Both readers detected more osteolytic and osteoblastic metastases with CAD than without CAD. CONCLUSION: Our temporal 3D-CT subtraction CAD software easily detected vertebral metastases on the follow-up CT images of lung cancer patients regardless of the osteolytic or osteoblastic nature of the lesions.


Asunto(s)
Neoplasias Óseas/secundario , Imagenología Tridimensional/métodos , Neoplasias Pulmonares/patología , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/patología , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias Óseas/diagnóstico por imagen , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/patología , Femenino , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Curva ROC , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos , Carcinoma Pulmonar de Células Pequeñas/diagnóstico por imagen , Carcinoma Pulmonar de Células Pequeñas/patología , Programas Informáticos
11.
Cancer Imaging ; 16(1): 18, 2016 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-27455976

RESUMEN

BACKGROUND: To investigate the correlation between iodine-related attenuation of dual-energy computed tomography (DE-CT) and the histopathological invasiveness of surgically resected primary non-small cell lung cancers (NSCLCs) ≤ 3 cm in diameter. METHODS: We selected 63 consecutive NSCLC lesions from 60 patients (32 males, 28 females; age range, 39-85 years; mean age, 68 years). After injection of iodinated contrast media, arterial phases were scanned using 140-kVp and 80-kVp tube voltages. Three-dimensional iodine-related attenuation (3D-IRA) of primary tumors at the arterial phase was computed using "lung nodule" application software. The corrected 3D-IRA normalized to the patient's body weight and contrast medium concentration was then calculated. Single-factor analysis of variance (ANOVA) was used for comparison among tumor differentiation grade groups. Univariate and multivariate logistic regression analysis was used for the correlation between locoregional invasive tumor and clinical factors. RESULTS: Resected tumors were histopathologically classified into well-differentiated (G1; n = 24), moderately-differentiated (G2; n = 28), and poorly-differentiated (G3; n = 11) groups by degree of tumor differentiation. The mean ± standard deviation of the 3D-IRA was 56.1 ± 22.6 HU in G1 tumours, 48.5 ± 23.9 HU in G2 tumours, and 28.4 ± 15.8 HU in G3 tumours; significant differences were observed between groups by ANOVA. (p = 0.005). Univariate logistic analysis showed that the 3D-IRA and corrected 3D-IRAs were significantly correlated with locoregional invasive tumors (p = 0.002 and p < 0.001, respectively). Multivariate logistic analysis revealed that only the corrected 3D-IRA was significantly correlated with tumor invasiveness (p = 0.003), while gender, clinical size, and solid/subsolid type were not (p = 0.950, p = 0.057 and p = 0.456, respectively). CONCLUSIONS: The 3D-IRA of small-sized NSCLCs was significantly associated with and invasiveness. Low 3D-IRA tumors tended to have greater invasiveness than high 3D-IRA tumors.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma de Pulmón de Células no Pequeñas/patología , Femenino , Humanos , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Invasividad Neoplásica
12.
Br J Radiol ; 88(1055): 20150224, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26329466

RESUMEN

OBJECTIVE: To investigate the correlation between iodine concentration of dual-energy CT (DECT) and histopathology of surgically resected primary lung cancers. METHODS: We reviewed the medical records, post-operative pathological records and pre-operative DECT images of patients who underwent surgical lung resection for primary lung cancer. After injection of iodinated contrast media, arterial and delayed phases were scanned using 140- and 80-kV tube voltages. Three-dimensional iodine concentration (iodine volume) of primary tumours was calculated using lung nodule application software. RESULTS: A total of 60 patients (37 males and 23 females; age range, 39-84 years; mean age, 69 years) with 62 lung cancers were analysed. The resected tumours were histopathologically classified into well-differentiated (G1; n = 20), moderately differentiated (G2; n = 29), poorly differentiated (G3; n = 9) and undifferentiated (G4; n = 4) groups by degree of tumour differentiation (DTD). The mean ± standard deviation of iodine volume at the delayed phase was 59.6 ± 18.6 HU in G1 tumours, 46.5 ± 11.3 HU in G2 tumours, 34.3 ± 15.0 HU in G3 tumours and 28.8 ± 6.4 HU in G4 tumours; significant differences were observed between groups (p < 0.001). Univariate logistic regression analysis showed that iodine volumes both at the early and delayed phases were significantly correlated with DTD (p = 0.006 and p = 0.001, respectively), whereas gender, body weight and tumour size were not (p = 0.084, p = 0.062 and p = 0.391, respectively). CONCLUSION: The iodine volume of lung cancers was significantly associated with their DTD. High-grade tumours tended to have lower iodine volumes than low-grade tumours. ADVANCES IN KNOWLEDGE: Iodine volume measured by DECT could be a valuable functional imaging method to estimate differentiation of primary lung cancer.


Asunto(s)
Imagenología Tridimensional , Neoplasias Pulmonares/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Yohexol/análogos & derivados , Yopamidol , Neoplasias Pulmonares/patología , Neoplasias Pulmonares/cirugía , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Ácidos Triyodobenzoicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA