1.
Ultrasonics ; 43(10): 815-21, 2005 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16054665

RESUMEN

This work describes the results of initial evaluation of a wideband acousto-optic hydrophone probe designed to operate as point receiver in the frequency range up to 100 MHz. The hydrophone was implemented as a tapered fiber optic (FO) probe sensor with a tip diameter of approximately 7 microm. Such small physical dimensions of the sensor eliminate the need for spatial averaging corrections so that true pressure-time (p-t) waveforms can be faithfully recorded. The theoretical considerations that predicted the FO probe sensitivity to be equal to 4.3 mV/MPa are presented along with a brief description of the manufacturing process. The calibration results that verified the theoretically predicted sensitivity are also presented along with a brief description of the improvements being currently implemented to increase this sensitivity level by approximately 20 dB. The results of preliminary measurements indicate that the fiber optic probes will exhibit a uniform frequency response and a zero phase shift in the frequency range considered. These features might be very useful in rapid complex calibration i.e. determining both magnitude and phase response of other hydrophones by the substitution method. Also, because of their robust design and linearity, these fiber optic hydrophones could also meet the challenges posed by high intensity focused ultrasound (HIFU) and other therapeutic applications. Overall, the outcome of this work shows that when fully developed, the FO probes will be well suited for high frequency measurements of ultrasound fields and will be able to complement the data collected by the current finite aperture piezoelectric PVDF hydrophones.


Asunto(s)
Acústica , Óptica y Fotónica , Ultrasonido , Tecnología de Fibra Óptica , Modelos Teóricos , Fibras Ópticas
2.
Ultrasonics ; 49(3): 306-11, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19110289

RESUMEN

The primary objective of this work was to develop and optimize the calibration techniques for ultrasonic hydrophone probes used in acoustic field measurements up to 100 MHz. A dependable, 100 MHz calibration method was necessary to examine the behavior of a sub-millimeter spatial resolution fiber optic (FO) sensor and assess the need for such a sensor as an alternative tool for high frequency characterization of ultrasound fields. Also, it was of interest to investigate the feasibility of using FO probes in high intensity fields such as those employed in HIFU (high intensity focused ultrasound) applications. In addition to the development and validation of a novel, 100 MHz calibration technique the innovative elements of this research include implementation and testing of a prototype FO sensor with an active diameter of about 10 microm that exhibits uniform sensitivity over the considered frequency range and does not require any spatial averaging corrections up to about 75 MHz. The results of the calibration measurements are presented and it is shown that the optimized calibration technique allows the sensitivity of the hydrophone probes to be determined as a virtually continuous function of frequency and is also well suited to verify the uniformity of the FO sensor frequency response. As anticipated, the overall uncertainty of the calibration was dependent on frequency and determined to be about +/-12% (+/-1 dB) up to 40 MHz, +/-20% (+/-1.5 dB) from 40 to 60 MHz and +/-25% (+/-2dB) from 60 to 100 MHz. The outcome of this research indicates that once fully developed and calibrated, the combined acousto-optic system will constitute a universal reference tool in the wide, 100 MHz bandwidth.


Asunto(s)
Algoritmos , Tecnología de Fibra Óptica/instrumentación , Interpretación de Imagen Asistida por Computador/métodos , Dispositivos Ópticos , Transductores , Ultrasonografía/instrumentación , Tecnología de Fibra Óptica/normas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Ultrasonografía/normas , Estados Unidos