Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 114
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Biochem Biophys Res Commun ; 592: 74-80, 2022 02 12.
Artículo en Inglés | MEDLINE | ID: mdl-35032835

RESUMEN

Crohn's disease is an inflammatory disease of the gut caused by a complex interplay among genetic, microbial, and environmental factors. The intestinal tract is constantly exposed to metals and other trace elements ingested as food. Synchrotron radiation-induced X-ray fluorescence spectroscopy and X-ray absorption fine structure analysis revealed the deposition of nickel particles within Crohn's disease tissue specimens. After nickel particle stimulation, THP-1 cells showed filopodia formation and autophagic vacuoles containing lipid bodies. Nickel particles precipitated colitis in mice bearing mutations of the IBD susceptibility protein A20/TNFAIP3. Nickel particles also exacerbated dextran sulfate sodium-induced colitis in mice harboring myeloid cell-specific Atg5 deficiency. These findings illustrate that nickel particle ingestion may worsen Crohn's disease by perturbing autophagic processes in the intestine, providing new insights into environmental factors in Crohn's disease pathogenesis.


Asunto(s)
Enfermedad de Crohn/patología , Progresión de la Enfermedad , Inflamación/patología , Intestinos/patología , Níquel/toxicidad , Animales , Autofagia/efectos de los fármacos , Proteína 5 Relacionada con la Autofagia/metabolismo , Sulfato de Dextran , Susceptibilidad a Enfermedades , Humanos , Macrófagos/efectos de los fármacos , Macrófagos/patología , Macrófagos/ultraestructura , Ratones Endogámicos C57BL , Células THP-1 , Proteína 3 Inducida por el Factor de Necrosis Tumoral alfa/metabolismo
2.
Biochem Biophys Res Commun ; 542: 17-23, 2021 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-33482469

RESUMEN

Nickel, the most frequent contact allergy cause, is widely used for various metallic materials and medical devices. Autophagy is an intracellular protein degradation system and contributes to metal recycling. However, it is unclear the functions of nickel in autophagy. We here demonstrated that NiCl2 induced microtubule-associated protein 1 light chain 3 (LC3)-II and LC3 puncta, markers of autophagosomes. Bafilomycin A1 (BafA1) treatment did not enhance LC3 puncta under NiCl2 stimulation, suggesting that NiCl2 did not induce autophagic flux. In addition, NiCl2 promotes the accumulation of SQSTM1/p62 and increased SQSTM1/p62 colocalization with lysosomal-associated membrane protein 1 (LAMP1). These data indicated that NiCl2 attenuates autophagic flux. Interestingly, NiCl2 induced the expression of the high-molecular-weight (MW) form of SQSTM1/p62. Inhibition of NiCl2-induced reactive oxygen species (ROS) reduced the high-MW SQSTM1/p62. We also showed that NiCl2-induced ROS activate transglutaminase (TG) activity. We found that transglutaminase 2 (TG2) inhibition reduced high-MW SQSTM1/p62 and SQSTM1/p62 puncta under NiCl2 stimulation, indicating that TG2 regulates SQSTM1/p62 protein homeostasis under NiCl2 stimulation. Our study demonstrated that nickel ion regulates autophagy flux and TG2 restricted nickel-dependent proteostasis.

3.
Sensors (Basel) ; 21(4)2021 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-33671506

RESUMEN

Teeth clenching during exercise is important for sports performance and health. Recently, several mouth guard (MG)-type wearable devices for exercise were studied because they do not disrupt the exercise. In this study, we developed a wearable MG device with force sensors on both sides of the maxillary first molars to monitor teeth clenching. The force sensor output increased linearly up to 70 N. In four simple occlusion tests, the trends exhibited by the outputs of the MG sensor were consistent with those of an electromyogram (EMG), and the MG device featured sufficient temporal resolution to measure the timing of teeth clenching. When the jaw moved, the MG sensor outputs depended on the sensor position. The MG sensor output from the teeth-grinding test agreed with the video-motion analysis results. It was comparatively difficult to use the EMG because it contained a significant noise level. Finally, the usefulness of the MG sensor was confirmed through an exercise tolerance test. This study indicated that the developed wearable MG device is useful for monitoring clenching timing and duration, and the degree of clenching during exercise, which can contribute to explaining the relationship between teeth clenching and sports performance.


Asunto(s)
Bruxismo , Protectores Bucales , Dispositivos Electrónicos Vestibles , Fuerza de la Mordida , Electromiografía , Humanos , Contracción Muscular
4.
Chem Rec ; 19(7): 1157-1165, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30088337

RESUMEN

Surface fluorescence X-ray absorption fine structure (XAFS) spectroscopy using a Laue-type monochromator has been developed to acquire structural information about metals with a very low concentrate on a flat highly oriented pyrolytic graphite (HOPG) surface in the presence of electrolytes. Generally, surface fluorescence XAFS spectroscopy is hindered by strong scattering from the bulk, which often chokes the pulse counting detector. In this work, we show that a bent crystal Laue analyzer (BCLA) can efficiently remove the scattered X-rays from the bulk even in the presence of solution. We applied the technique to submonolayer (∼1014  atoms cm-2 ) Pt on HOPG and successfully obtained high signal/noise in situ XAFS data in combination with back-illuminated fluorescence XAFS (BI-FXAFS) spectroscopy. This technique allows in situ XAFS measurements of flat electrode surfaces to be performed in the presence of electrolytes.

5.
J Bone Miner Metab ; 37(4): 676-684, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30465092

RESUMEN

Medication-related osteonecrosis of the jaw (MRONJ) is a serious adverse effect of antiresorptive agents like bisphosphonates. Abnormal concentrations of various trace metallic elements contained in bone minerals have been associated with MRONJ. In this study, we focused on trace metallic elements contained in the MRONJ sequestrum; their content and distribution were compared to those in osteomyelitis and non-inflammatory bones using inductively coupled plasma atomic emission spectroscopy (ICP-AES) and synchrotron radiation X-ray fluorescence analysis (SR-XRF). On ICP-AES analyses, various trace elements (Co, Cr, Cu, Fe, K, Mg, Ni, Sb, Ti, V, Pb) were significantly more in MRONJ sequestra than non-inflammatory bones. The Cu content was significantly higher in MRONJ sequestra than osteomyelitis and non-inflammatory bones. The Cu content in MRONJ sequestra was high even after decalcification. Additionally, Cu was distributed along the trabecular structures in decalcified MRONJ specimens, as observed using SR-XRF analysis. Therefore, this study was indicative of the characteristic behavior of Cu in MRONJ.


Asunto(s)
Osteonecrosis de los Maxilares Asociada a Difosfonatos/metabolismo , Espectrofotometría Atómica/métodos , Sincrotrones , Oligoelementos/análisis , Adulto , Anciano , Anciano de 80 o más Años , Osteonecrosis de los Maxilares Asociada a Difosfonatos/patología , Femenino , Fluorescencia , Humanos , Masculino , Persona de Mediana Edad , Rayos X
6.
J Adhes Dent ; 21(1): 51-58, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30799471

RESUMEN

PURPOSE: To investigate the efficacy of different ceramic surface cleaning methods after saliva contamination on the resin bond strength to lithium disilicate ceramics. MATERIALS AND METHODS: 300 e.max CAD blocks (Ivoclar Vivadent) were polished with 600-grit silicon carbide paper and divided into five groups with or without human saliva contamination and according to the surface treatment performed (n = 10); control: no pretreatment; MP: Monobond Plus; PA+MP: 37% phosphoric acid (PA) followed by MP; HF+MP: 5% hydrofluoric acid (HF) followed by MP; MEP: Monobond Etch & Prime. The specimens were bonded with one of three resin cements: Variolink Esthetic DC (VE), Multilink Automix (MA) and Speed CEM (SC). After 24-h water storage, tensile bond strength (TBS) was measured. The ceramic surfaces after pretreatment were analyzed using x-ray photoelectron spectroscopy (XPS). RESULTS: XPS analysis showed similar elemental distributions between saliva contamination vs no saliva in PA, HF, and MEP. The TBSs were significantly influenced by surface treatments (p < 0.05). HF+MP and MEP showed statistically non-significantly different bond strengths to saliva-contaminated HF+MP and MEP, but were different from MP and saliva-contaminated MP. The TBSs after 24 h were significantly higher in HF+MP and MEP groups with VE. HF+MP and MEP did not show statistically significant differences among any groups with or without saliva contamination. CONCLUSION: Surface treatments with PA or HF followed by silane or by MEP alone were effective in removing saliva contamination and enhancing the resin bond strength.


Asunto(s)
Recubrimiento Dental Adhesivo , Litio , Cerámica , Porcelana Dental , Humanos , Ensayo de Materiales , Cementos de Resina , Saliva , Propiedades de Superficie , Resistencia a la Tracción
7.
J Adhes Dent ; 20(5): 453-459, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30375581

RESUMEN

PURPOSE: To evaluate the bonding efficacy of 4-META/MMA-TBB resin to highly translucent zirconia subjected to various surface treatments. MATERIALS AND METHODS: Highly translucent zirconia specimens (Zpex Smile, Tosoh; 11.5 mm diameter, 5.0 mm thick) were mechanically pre-treated to improve micromechanical interlocking either by sandblasting with 50-µm Al2O3 particles (Kulzer Japan) or subjecting the specimens to a low-pressure plasma treatment (PM100, Yamato), or evaluated using the as-sintered surfaces as controls. Next, specimens from each condition were primed with an MDP-containing primer (PZ Primer, Sun Medical), while some remained unprimed. All specimens were bonded to stainless rods using 4-META/MMA-TBB resin (Super-Bond, Sun Medical). The specimens were stored in ultrapure water at 37°C for 24 h, after which a portion were subjected to 10,000 thermocycles. For all specimens (n=10/group) the tensile bond strength (TBS) was determined with a universal testing machine. The measured values were statistically analyzed using Weibull analysis. Fractographic analysis was performed using a light microscope and an SEM. RESULTS: After aging, Weibull analysis revealed significantly lower bond strengths for both as-sintered and plasma-treated zirconia without a primer treatment. The fractographic analysis showed that these two conditions resulted in a higher frequency of adhesive failure. CONCLUSION: Chemical pre-treatment with an MDP-containing primer improved bonding efficacy of 4-META/MMA-TBB resin to highly translucent zirconia. In addition, Al2O3 sandblasting resulted in durable bonding of 4-META/MMA-TBB resin to highly translucent zirconia, regardless of chemical pre-treatment.


Asunto(s)
Compuestos de Boro/química , Recubrimiento Dental Adhesivo/métodos , Materiales Dentales/química , Metacrilatos/química , Metilmetacrilatos/química , Circonio/química , Técnicas In Vitro , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Resistencia a la Tracción
8.
J Adhes Dent ; 20(3): 261-268, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29904754

RESUMEN

PURPOSE: To evaluate the influence of different surface treatments of lithium disilicate glass ceramics on the bonding efficacy of three luting composites. MATERIALS AND METHODS: A total of 450 blocks of e.max CAD (Ivoclar Vivadent) ground with 600-grit silicon carbide paper were prepared and divided into three groups (n = 150) according to the composite cements used: Variolink Esthetic DC (VE), Multilink Automix (MA), and SpeedCEM (SC). Each group was further divided into five subgroups (n = 10) according to the surface treatment performed: no treatment (control), Monobond Plus (MP), 37% phosphoric acid and Monobond Plus (PA), < 5% hydrofluoric acid and Monobond Plus (HF), and Monobond Etch & Prime (ME). All treated ceramic specimens were bonded with three composite cements and light cured. After 24-h water storage and 5000 or 10,000 thermocycles, tensile bond strength (TBS) was measured. The specimens underwent failure mode analysis. The results were statistically analyzed using two-way ANOVA and t-tests with Bonferroni correction. RESULTS: The TBSs were significantly influenced by surface treatments (p < 0.05). There were no significant differences in HF and ME among most of the groups. Furthermore, ME showed the highest bond strength with MA after 10,000 thermocycling. Most specimens of the ME groups exhibited cohesive failures, whereas a combination of adhesive failures and mixed failures were observed in control, MP, PA, and HF groups. CONCLUSION: In the surface treatment of lithium disilicate glass ceramics, Monobond Etch & Prime was found to be a possible substitution for the combination of hydrofluoric acid and Monobond Plus.


Asunto(s)
Grabado Ácido Dental , Recubrimiento Dental Adhesivo , Cerámica , Porcelana Dental , Ácido Fluorhídrico , Ensayo de Materiales , Silanos , Propiedades de Superficie , Resistencia a la Tracción
9.
J Formos Med Assoc ; 117(1): 71-79, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28408197

RESUMEN

BACKGROUND/PURPOSE: The application of an appropriate force system is indispensable for successful orthodontic treatments. Second-order moment control is especially important in many clinical situations, so we developed a new force system composed of a straight orthodontic wire and two crimpable hooks of different lengths to produce the second-order moment. The objective of this study was to evaluate this new force system and determine an optimum condition that could be used in clinics. METHODS: We built a premolar extraction model with two teeth according to the concept of a modified orthodontic simulator. This system was activated by applying contractile force from two hooks that generated second-order moment and force. The experimental device incorporated two sensors, and forces and moments were measured along six axes. We changed the contractile force and hook length to elucidate their effects. Three types of commercial wires were tested. RESULTS: The second-order moment was greater on the longer hook side of the model. Vertical force balanced the difference in moments between the two teeth. Greater contractile force generated a greater second-order moment, which reached a limit of 150 g. Excessive contractile force induced more undesired reactions in the other direction. Longer hooks induced greater moment generation, reaching their limit at 10 mm in length. CONCLUSION: The system acted similar to an off-center V-bend and can be applied in clinical practice as an unconventional loop design. We suggest that this force system has the potential for second-order moment control in clinical applications.


Asunto(s)
Soportes Ortodóncicos , Cierre del Espacio Ortodóncico/métodos , Alambres para Ortodoncia , Técnicas de Movimiento Dental/instrumentación , Diente Premolar/cirugía , Fenómenos Biomecánicos , Análisis del Estrés Dental , Humanos , Estrés Mecánico
10.
Phys Chem Chem Phys ; 18(10): 7374-80, 2016 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-26899557

RESUMEN

Of late, battery-driven high-performance gas sensors have gained acceptability in practical usage, whose atomic-scale structure has been revealed by µ-fluorescence X-ray absorption fine structure analysis. We studied the chemical distribution of Pd species in the Pd/Al2O3 catalyst overlayer in the real gas sensor at various degrees of deterioration. In a freshly prepared sensor, all Pd species were in the PdO form; in a heavily deteriorated sensor, Pd/Al2O3 in the external region changed to metallic Pd particles, while the PdO structure in the inner region near the heater remained unchanged. The Pd species distribution was in agreement with the simulated thermal distribution. Temperature control was crucial to maintain the high performance of the gas sensor. The improved sensor allows homogeneous heating and has a lifetime of more than 5 years.

11.
Dent Traumatol ; 32(6): 474-479, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27126657

RESUMEN

PURPOSE: The purpose of this study was to investigate the shock absorption capability of commercial thermoforming mouthguard sheet materials. MATERIALS AND METHODS: Twelve commercial thermoforming mouthguard sheet materials were selected as test materials. The impact test was applied by a free-falling steel ball. When impact forces of approximately 660 N were applied on the commercial thermoforming mouthguard materials, the peak intensities were measured using the load cell sensor. The peak intensity and the time to peak intensity from the onset of the transmitted force were statistically analyzed using one-way anova and Tukey's honest significant difference post hoc test (P < 0.05). RESULTS: Statistical analysis for the peak intensity and the time to peak intensity from the onset of the transmitted force revealed significant differences among the thirteen groups including the control. The peak intensity of the polystyrene-polyolefin copolymer-based material was lower than the peak intensity of the EVA-, polyolefin-based material. Polyolefin-based materials had a tendency of a long duration to reach peak intensity from the onset of the transmitted force. CONCLUSION: These results suggest that all of the commercially available mouthguard sheet materials had high shock-absorbing capabilities.


Asunto(s)
Diseño de Equipo , Protectores Bucales , Ensayo de Materiales , Polivinilos , Acero
12.
Biometals ; 28(1): 11-20, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25522792

RESUMEN

The effects of dissolved elements from metal dental restorations are a major concern in lesions of the oral mucosa, and the evaluation of accumulated metal elements, especially their distribution and chemical state, is essential for determining the precise effects of trace metals. In this study, X-ray fluorescence with synchrotron radiation (SR-XRF) and particle-induced X-ray emission (PIXE) were applied for distribution analysis of the trace metal elements contained in the oral mucosa, and the chemical states of the elements were estimated using X-ray absorption fine structure (XAFS) analysis. Appropriate combination of these analysis techniques, particularly SR-XRF and PIXE, to visualize the distributions of the elements in the oral mucosa allowed for the observation and evaluation of accumulated metal ions and debris. Importantly, the analyses in this study could be carried out using conventional histopathological specimens without damaging the specimens. Therefore, this method would be applicable for the detection of accumulated trace metal elements in biopsy specimens from the oral mucosa.


Asunto(s)
Mucosa Bucal/metabolismo , Espectrometría por Rayos X/métodos , Oligoelementos/análisis , Adulto , Femenino , Humanos , Técnicas In Vitro , Masculino , Persona de Mediana Edad
13.
J Nanobiotechnology ; 12: 51, 2014 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-25467761

RESUMEN

BACKGROUND: Patch tests are often used in the clinical diagnosis of metal allergies. In currently available patch tests, high concentrations of metal salt solutions are used. However, diagnosis accuracy can be influenced not only by acute skin reactions to high concentrations of metal salt, but also by skin reactions to other components present in the patch or to pH changes. In this study, we developed Ni nanoparticles (termed "nanoballs") for use in patch-test solutions. FINDINGS: Highly soluble, spherical Ni nanoballs were prepared using plasma electrolysis. The Ni released from the nanoballs permeated through a dialysis membrane, and the nanoball-containing solution's pH was maintained constant. Ni ions were released slowly at low concentrations in a time-dependent manner, which contrasted the rapid release observed in the case of a commercial patch test. Consequently, in the new test system, reactions caused by high concentrations of metal salts were avoided. CONCLUSIONS: By exploiting the high specific surface area of Ni nanoballs, we obtained an effective dissolution of Ni ions that triggered Ni allergy in the absence of direct contact between the nanoballs and mouse skin. This novel patch system can be applied to other metals and alloys for diagnosing various types of metal-induced contact dermatitis.


Asunto(s)
Nanopartículas/química , Níquel/química , Níquel/inmunología , Pruebas del Parche/instrumentación , Pruebas del Parche/métodos , Animales , Usos Diagnósticos de Compuestos Químicos , Concentración de Iones de Hidrógeno , Ratones Endogámicos C57BL , Nanotecnología/métodos , Níquel/farmacocinética , Piel/inmunología , Espectrometría por Rayos X/métodos
14.
J Nanosci Nanotechnol ; 14(4): 2891-4, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24734706

RESUMEN

In this study, we produced europium-doped yttoria (Y2O3:Eu) nanoparticles and investigated their photoluminescent properties and biocompatibility. The Y2O3:Eu nanoparticles showed excellent photoluminescent properties and cytocompatibility. We also analyzed the photophysical properties of the nanoparticles in PMMA films. When the Y2O3:Eu nanoparticles were incorporated in the polymer film, they showed a strong red emission spectrum, similar to that seen with the particles alone. Energy dispersive X-ray spectroscopy (EDS) measurements indicated that the particles were distributed homogeneously in the PMMA film. Such materials could be applied not only to optoelectronic devices but also to biomedical applications such as bioimaging tools or luminescent medical/dental adhesive materials.

15.
J Prosthet Dent ; 112(6): 1545-52, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25023010

RESUMEN

STATEMENT OF PROBLEM: Attachment wear can decrease the retentive force of 2-implant overdentures (2-IODs). PURPOSE: The purpose of this in vitro study was to investigate the trend of change in retentive force for 6 different bar attachments during dislodgement. MATERIAL AND METHODS: Round and Dolder bars were made of platinum-added gold alloy (PGA), cobalt chromium alloy (Co-Cr), and commercially pure titanium grade IV (Ti). Clips were made of PGA. Retentive force was measured during 7200 dislodging cycles. Simple linear regression analysis was performed in order to investigate the relationship between number of cycles and retentive force (P<.05). Subsequently, wear debris was analyzed, and the surface of the attachments was observed. RESULTS: The retentive force of the Co-Cr round bar attachment (CoCr-R) increased from 57.5 N to 68.3 N and the Ti round bar attachment (Ti-R) from 54.8 N to 59.7 N. However, the retentive force of the PGA round bar attachment (PGA-R) decreased from 69.3 N to 64.0 N. A positive relationship was found between the number of cycles and the retentive force of both CoCr-R and Ti-R. The composition of the wear debris was almost the same as for PGA. For the Dolder bar attachment, no changes were seen in retentive force (between 7.0 N to 12.0 N). CONCLUSIONS: For the round bar attachment, the PGA clip and PGA bar showed wear. The retentive force of PGA-R slightly decreased. The retentive force of CoCr-R and Ti-R tended to increase. For the Dolder bar attachment, all 3 types of bar attachment showed no wear.


Asunto(s)
Materiales Dentales/química , Prótesis Dental de Soporte Implantado , Diseño de Dentadura , Retención de Dentadura/instrumentación , Prótesis de Recubrimiento , Cromo/análisis , Aleaciones de Cromo/química , Cobalto/análisis , Diseño Asistido por Computadora , Cobre/análisis , Alisadura de la Restauración Dental , Oro/análisis , Aleaciones de Oro/química , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Paladio/análisis , Platino (Metal)/análisis , Platino (Metal)/química , Plata/análisis , Espectrometría por Rayos X , Estrés Mecánico , Propiedades de Superficie , Titanio/análisis , Titanio/química , Zinc/análisis
16.
Dent Mater J ; 43(1): 106-111, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38171742

RESUMEN

Cellulose nanofibrils (CNFs) exhibit excellent mechanical properties and are used to reinforce various composites. The effects of incorporating CNFs into commercial mineral trioxide aggregate (MTA) cements (NEX MTA (NEX) and ProRoot® MTA (PR)) on the underwater setting properties, compressive strength, and flowability were estimated in this study. NEX mixed without CNFs disintegrated after water immersion. NEX mixed with CNF-suspended solutions showed good setting properties under water immersion and a similar compressive strength, which was kept in air (100% relative humidity). PR did not degrade after water immersion, regardless of the presence of CNFs, and no significant difference in the compressive strength caused by CNFs incorporation was detected. The relative flowability of the NEX mixture decreased with increasing CNFs content up to 1.0 w/v%. The application of CNF-incorporated MTA in various dental cases is promising because CNFs prevent the water-immersion-dependent collapse of some MTA cements immediately after mixing.


Asunto(s)
Celulosa , Materiales de Obturación del Conducto Radicular , Óxidos , Compuestos de Calcio , Agua , Silicatos , Compuestos de Aluminio , Combinación de Medicamentos
17.
Sci Rep ; 14(1): 11468, 2024 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-38769339

RESUMEN

Diffusing alpha-emitters radiation therapy (Alpha-DaRT) is a unique method, in which interstitial sources carrying 224Ra release a chain of short-lived daughter atoms from their surface. Although DNA damage response (DDR) is crucial to inducing cell death after irradiation, how the DDR occurs during Alpha-DaRT treatment has not yet been explored. In this study, we temporo-spatially characterized DDR such as kinetics of DNA double-strand breaks (DSBs) and cell cycle, in two-dimensional (2D) culture conditions qualitatively mimicking Alpha-DaRT treatments, by employing HeLa cells expressing the Fucci cell cycle-visualizing system. The distribution of the alpha-particle pits detected by a plastic nuclear track detector, CR-39, strongly correlated with γH2AX staining, a marker of DSBs, around the 224Ra source, but the area of G2 arrested cells was more widely spread 24 h from the start of the exposure. Thereafter, close time-lapse observation revealed varying cell cycle kinetics, depending on the distance from the source. A medium containing daughter nuclides prepared from 224Ra sources allowed us to estimate the radiation dose after 24 h of exposure, and determine surviving fractions. The present experimental model revealed for the first time temporo-spatial information of DDR occurring around the source in its early stages.


Asunto(s)
Partículas alfa , Roturas del ADN de Doble Cadena , Humanos , Células HeLa , Roturas del ADN de Doble Cadena/efectos de la radiación , Daño del ADN/efectos de la radiación , Ciclo Celular/efectos de la radiación , Histonas/metabolismo , Técnicas de Cultivo de Célula/métodos
18.
Am J Pathol ; 181(5): 1659-71, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22940071

RESUMEN

Recessive dystrophic epidermolysis bullosa (RDEB) is caused by mutations in the gene encoding type VII collagen (COL7), a major component of anchoring fibrils in the epidermal basement membrane zone. Patients with RDEB present a low oral hygiene index and prevalent tooth abnormalities with caries. We examined the tooth enamel structure of an RDEB patient by scanning electron microscopy. It showed irregular enamel prisms, indicating structural enamel defects. To elucidate the pathomechanisms of enamel defects due to COL7 deficiency, we investigated tooth formation in Col7a1(-/-) and COL7-rescued humanized mice that we have established. The enamel from Col7a1(-/-) mice had normal surface structure. The enamel calcification and chemical composition of Col7a1(-/-) mice were similar to those of the wild type. However, transverse sections of teeth from the Col7a1(-/-) mice showed irregular enamel prisms, which were also observed in the RDEB patient. Furthermore, the Col7a1(-/-) mice teeth had poorly differentiated ameloblasts, lacking normal enamel protein-secreting Tomes' processes, and showed reduced mRNA expression of amelogenin and other enamel-related molecules. These enamel abnormalities were corrected in the COL7-rescued humanized mice expressing a human COL7A1 transgene. These findings suggest that COL7 regulates ameloblast differentiation and is essential for the formation of Tomes' processes. Collectively, COL7 deficiency is thought to disrupt epithelial-mesenchymal interactions, leading to defective ameloblast differentiation and enamel malformation in RDEB patients.


Asunto(s)
Ameloblastos/patología , Diferenciación Celular , Colágeno Tipo VII/deficiencia , Esmalte Dental/crecimiento & desarrollo , Esmalte Dental/patología , Diente/crecimiento & desarrollo , Diente/patología , Ameloblastos/metabolismo , Amelogénesis , Animales , Calcificación Fisiológica , Niño , Colágeno Tipo VII/metabolismo , Esmalte Dental/metabolismo , Esmalte Dental/ultraestructura , Epidermólisis Ampollosa Distrófica/patología , Epidermólisis Ampollosa Distrófica/fisiopatología , Femenino , Regulación del Desarrollo de la Expresión Génica , Humanos , Ratones , Modelos Biológicos , Fenotipo , Diente/metabolismo , Diente/ultraestructura
19.
Dent Mater J ; 42(6): 818-825, 2023 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-37821365

RESUMEN

In this study, fine powders of tristrontium aluminate (S3A) and distrontium cerate (S2Ce) cement were prepared using a dry grinding process, and their mechanical and ion dissolution properties were estimated. Fine cements showed the particles about 10 µm in diameter or smaller with sharp particle size distribution curves. The setting reaction of the fine cements was rapid; therefore, a 0.1% w/v of citric acid solution was used as the retarder. The compressive strengths of the fine cements were improved compared to those of the coarse cements at both 1 and 28 days after mixing at a water/powder ratio (W/P) of 0.4. The dissolution of Sr and Al ions from fine S3A cement was enhanced. However, the relative flowability decreases with fine grinding. Further studies on flowability, handling property are required. Additionally, the biological effects of endodontic cement should be studied both in vitro and in vivo.


Asunto(s)
Cementos Dentales , Estroncio , Cementos de Ionómero Vítreo , Agua , Cementos para Huesos , Fuerza Compresiva , Polvos , Ensayo de Materiales
20.
J Prosthodont Res ; 67(4): 641-646, 2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-37032072

RESUMEN

PURPOSE: We evaluated the effects of build orientation and bar addition between lingual flanges on the accuracy of mandibular denture bases fabricated using a digital light processing (DLP) device. METHODS: Mandibular denture bases with and without a bar at the lingual flanges were virtually designed and assigned to eight build orientations. Six dentures per condition were fabricated using a DLP device with a methacrylate-based photopolymerizable monomer (Dima Print denture base) (n=96). The fabricated denture surfaces were digitized, and intaglio surfaces were obtained. These digitized surfaces were compared via superimposition using graphical software (Artec studio12 profession) to their original designed files, and root mean square estimates were obtained. The trueness of the entire and intaglio data was statistically analyzed non-parametrically. RESULTS: The range of trueness of the entire and intaglio denture bases was 0.15-0.31 mm and 0.11-0.38 mm, respectively. The trueness at 135° and 270° for the entire denture base and that at 270° for the intaglio data without the bar were significantly lower than those for the other build orientations. The trueness at 270° was <0.15 mm irrespective of the conditions. The trueness with the bar of all build orientations, except that of 0° for intaglio data, was significantly smaller than or equal to the trueness without the bar of the corresponding build orientations. CONCLUSIONS: Build orientation and bar addition influenced the accuracy of the complete dentures fabricated using DLP. A build orientation of 270° is recommended for fabricating a mandibular complete denture, irrespective of the bar addition.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA