Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Med Dosim ; 46(1): 21-28, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32778521

RESUMEN

PURPOSE: Among patients with brain metastases, hippocampal avoidance whole brain radiation (HA-WBRT) preserves neurocognitive function relative to conventional WBRT but the feasibility of hippocampal sparing in patients with metastases in/near the hippocampus is unknown. We identified the incidence of hippocampal/perihippocampal metastases and evaluated the feasibility of HA-WBRT in such patients. MATERIALS/METHODS: Dosimetric data from 34 patients randomized to HA-WBRT (30 Gy/10 fractions) in a phase III trial (NCT03075072) comparing HA-WBRT to stereotactic radiation in patients with 5 to 20 brain metastases were analyzed. Patients with metastases in/near the hippocampi received HA-WBRT with prioritization of tumor coverage over hippocampal avoidance. Target coverage and hippocampal sparing metrics were compared between patients with targets in/near the hippocampus versus not. RESULTS: In total, 9 of 34 (26%) patients had targets in the hippocampus and an additional 5 of 34 (15%) patients had targets in the hippocampal avoidance zone (HAZ, hippocampus plus 5 mm expansion) but outside the hippocampus. Patients with targets within the hippocampus and those with targets in the HAZ but outside the hippocampus were spared 34% and 73% of the ipsilateral mean biologically equivalent prescription dose, respectively. Of the latter cohort, 88% and 25% met conventional hippocampal sparing metrics of Dmin ≤ 9 Gy and Dmax ≤ 16 Gy, respectively. Among 11 patients with unilateral hippocampal/perihippocampal involvement, the uninvolved/contralateral hippocampus was limited to Dmin ≤ 9 Gy and Dmax ≤ 17 Gy in all cases. CONCLUSIONS: In this study, a substantial percentage of patients with 5 to 20 brain metastases harbored metastases in/near the hippocampus. In such cases, minimizing hippocampal dose while providing tumor coverage was feasible and may translate to neurocognitive protection.


Asunto(s)
Irradiación Craneana , Planificación de la Radioterapia Asistida por Computador , Estudios de Factibilidad , Hipocampo , Humanos , Tratamientos Conservadores del Órgano , Estudios Prospectivos
2.
Artículo en Inglés | MEDLINE | ID: mdl-33305025

RESUMEN

PURPOSE: MR-linacs (MRLs) have enabled the use of stereotactic magnetic resonance (MR) guided online adaptive radiotherapy (SMART) across many cancers. As data emerges to support SMART, uncertainty remains regarding optimal technical parameters, such as optimal patient positioning, immobilization, image quality, and contouring protocols. Prior to clinical implementation of SMART, we conducted a prospective study in healthy volunteers (HVs) to determine optimal technical parameters and to develop and practice a multidisciplinary SMART workflow. METHODS: HVs 18 years or older were eligible to participate in this IRB-approved study. Using a 0.35 T MRL, simulated adaptive treatments were performed by a multi-disciplinary treatment team in HVs. For each scan, image quality parameters were assessed on a 5-point scale (5 = extremely high, 1 = extremely poor). Adaptive recontouring times were compared between HVs and subsequent clinical cases with a t-test. RESULTS: 18 simulated treatments were performed in HVs on MRL. Mean parameters for visibility of target, visibility of nearby organs, and overall image quality were 4.58, 4.62, and 4.62, respectively (range of 4-5 for all measures). In HVs, mean ART was 15.7 min (range 4-35), comparable to mean of 16.1 (range 7-33) in the clinical cases (p = 0.8963). Using HV cases, optimal simulation and contouring guidelines were developed across a range of disease sites and have since been implemented clinically. CONCLUSIONS: Prior to clinical implementation of SMART, scans of HVs on an MRL resulted in acceptable image quality and target visibility across a range of organs with similar ARTs to clinical SMART. We continue to utilize HV scans prior to clinical implementation of SMART in new disease sites and to further optimize target tracking and immobilization. Further study is needed to determine the optimal duration of HV scanning prior to clinical implementation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA