Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
J Vasc Interv Radiol ; 34(12): 2224-2232.e3, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37684003

RESUMEN

OBJECTIVES: To identify the most suitable size of imaging-visible embolic agents with balanced safety and efficacy for bariatric arterial embolization (BAE) in a preclinical model. MATERIALS AND METHODS: Twenty-seven pigs were divided into 3 cohorts. In Cohort I, 16 pigs were randomized to receive (n = 4 each) 40-100-µm microspheres in 1 or 2 fundal arteries, 70-340-µm radiopaque microspheres in 2 fundal arteries, or saline. In Cohort II, 3 pigs underwent renal arterial embolization with either custom-made 100-200-µm, 200-250-µm, 200-300-µm, or 300-400-µm radiopaque microspheres or Bead Block 300-500 µm with microsphere distribution assessed histologically. In Cohort III, 8 pigs underwent BAE in 2 fundal arteries with tailored 100-200-µm radiopaque microspheres (n = 5) or saline (n = 3). RESULTS: In Cohort I, no significant differences in weight or ghrelin expression were observed between BAE and control animals. Moderate-to-severe gastric ulcerations were noted in all BAE animals. In Cohort II, renal embolization with 100-200-µm microspheres occluded vessels with a mean diameter of 139 µm ± 31, which is within the lower range of actual diameters of Bead Block 300-500 µm. In Cohort III, BAE with 100-200-µm microspheres resulted in significantly lower weight gain (42.3% ± 5.7% vs 51.6% ± 2.9% at 8 weeks; P = .04), fundal ghrelin cell density (16.1 ± 6.7 vs 23.6 ± 12.6; P = .045), and plasma ghrelin levels (1,709 pg/mL ± 172 vs 4,343 pg/mL ± 1,555; P < .01) compared with controls and superficial gastric ulcers (5/5). CONCLUSIONS: In this preclinical model, tailored 100-200-µm microspheres were shown to be most suitable for BAE in terms of safety and efficacy.


Asunto(s)
Bariatria , Embolización Terapéutica , Animales , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/métodos , Ghrelina , Microesferas , Estómago/irrigación sanguínea , Porcinos
2.
Semin Intervent Radiol ; 36(2): 133-136, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31123386

RESUMEN

The incidence of posttransplant hepatic arterial stenosis (HAS) has been reported in 5 to 10% of orthotopic liver transplants and, left untreated, can lead to hepatic arterial thrombosis. Most vascular complications develop less than 3 months after initial transplant, with thrombosis representing over half of all complications. There has been a trend toward minimally invasive, endovascular techniques for treating HAS with angioplasty and stenting. In one review of endovascular therapies for HAS, primary technical success was achieved in 95% of the interventions. Complication rates following endovascular repair of HAS have been reported to be between 0 and 23% in the literature. The main risk factors for complications include tortuosity of the hepatic artery and history of a second liver transplant. Other associated risk factors include female gender, age greater than 60 years, prior history of transarterial chemoembolization, and multiple arterial graft anastomoses. The case presented here is representative of a complication of balloon rupture and fragmentation in a patient undergoing hepatic arterial stent placement post-liver transplant.