Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Forensic Sci Med Pathol ; 20(1): 174-177, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36763092

RESUMEN

Forensic pathology increasingly uses postmortem magnetic resonance imaging (PMMRI), particularly in pediatric cases. It should be noted that each (sudden and unexpected) death of an infant or child should have a forensic approach as well. Current postmortem imaging protocols do not focus adequately on forensic queries. First, it is important to demonstrate or rule out bleeding, especially in the brain. Thus, when incorporating PMMRI, a blood sensitive sequence (T2* and/or susceptibility weighted imaging (SWI)) should always be included. Secondly, as intracranial air might mimic small focal intracerebral hemorrhages, PMMRI should be preceded by postmortem CT (PMCT) since air is easily recognizable on CT. This will be illustrated by a case of a deceased 3-week-old baby. Finally, note that postmortem scans will often be interpreted by clinical radiologists, sometimes with no specific training, which makes this case report relevant for a broader audience.


Asunto(s)
Artefactos , Imágenes Post Mortem , Lactante , Humanos , Niño , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Hemorragia Cerebral
2.
Artículo en Inglés | MEDLINE | ID: mdl-38896346

RESUMEN

We aimed to investigate the potential added value of postmortem MRI (PMMRI) in sudden unexpected infant death (SUID) cases referred to our center between September 2020 and June 2023. Ultimately, 19 SUID cases underwent PMMRI alongside standard autopsy procedures, which included technical examinations such as postmortem CT (PMCT). Four radiologists, two with prior PMMRI experience, provided structured reports following consensus. For each case, the responsible forensic medicine specialist documented the cause of death before and after reviewing the PMMRI report. Additionally, they assessed the overall impact of the PMMRI report and had the opportunity to provide written comments. The results of our study indicate that none of the PMMRI reports altered the prior determined cause of death, which included cases of infection, asphyxia, and sudden infant death syndrome (SIDS). However, we observed a moderate impact in one case and a low impact in 10 cases. The moderate impact arose from the PMMRI report identifying hypoxic-ischemic changes, where histologic examination of the brain was perceived as normal. Conversely, in the 10 cases with a low impact, the PMMRI reports supported the autopsy findings, specifically indicating brain injury and intra-alveolar cellular infiltrates. In conclusion, our study suggests that while PMMRI may not be pivotal in determining the cause of death in SUID cases, it could aid in detecting hypoxic-ischemic changes and reinforcing brain and lung observations. However, distinguishing genuine lung pathology from postmortem changes using PMMRI remains challenging. Further research is warranted to clarify the role of PMMRI in forensic SUID investigations.

3.
Am J Forensic Med Pathol ; 42(3): 301-306, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-33833194

RESUMEN

ABSTRACT: Congenital pulmonary airway malformation (CPAM), previously known as congenital cystic airway malformation, is a developmental disorder of the lower respiratory tract. It is subdivided into 5 types based on clinical and pathologic features. Type 3, an adenomatoid type of CPAM, is the second rarest form of CPAM, occurring in approximately 5% of all CPAM cases. This article reports an autopsy of a nearly 11-week-old male infant, found unresponsive in bed with his mother. She had fallen asleep after breastfeeding a few hours prior. Although the autopsy and additional technical examinations did not uncover the exact cause of death, CPAM type 3 was eventually identified on histological examination. Taking into account the context of this case, in which accidental asphyxia/neglect could not be ruled out, it is thought that the presence of CPAM might have contributed to the demise of the infant. As CPAM is a rare congenital disorder, the diagnosis could easily be missed. Therefore, this article aims to raise awareness of this diagnosis and points out the clinical and pathologic features of this disorder.


Asunto(s)
Malformación Adenomatoide Quística Congénita del Pulmón/patología , Muerte Súbita del Lactante/etiología , Humanos , Hallazgos Incidentales , Lactante , Masculino
4.
Int J Legal Med ; 129(1): 159-64, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25030188

RESUMEN

PURPOSE: The aim of this study is to evaluate whether previously reported post-mortem CT findings in drowning can reliably distinguish drowning from asphyxiation by any other manner. MATERIALS AND METHODS: Cases (n = 14) were corpses with cause of death determined as drowning by concordant autopsy findings and physical and circumstantial evidence. Controls (n = 11) were corpses in which the cause of death was defined as asphyxiation by any other manner than submersion in a liquid. Images were evaluated for the presence of fluid in paranasal sinuses, mastoid air cells and lower airways, frothy foam in the upper airways, ground-glass opacity of the lung parenchyma, the height of the right hemi-diaphragm, the interpulmonary distance at the level of the aortic valve, the mean density of intracardiac blood, and gastric and esophageal contents. Descriptive statistics, Fisher's exact test, and Student's t test were used when appropriate. RESULTS: Only the height of the right hemi-diaphragm differed significantly (p = 0.045) between cases (mean 5.4) and controls (mean 4.3). Other findings were not significantly different between both groups. CONCLUSION: Our results indicate that it is not possible to reliably distinguish drowning from non-drowning asphyxiation on CT, because many findings in drowning were also present in non-drowning asphyxiation. CT indicators for drowning as the cause of death should therefore be defined with great caution, keeping in mind that they are not specific to only a single cause of death.


Asunto(s)
Asfixia/diagnóstico , Ahogamiento/diagnóstico , Tomografía Computarizada Multidetector , Válvula Aórtica/diagnóstico por imagen , Estudios de Casos y Controles , Diagnóstico Diferencial , Diafragma/diagnóstico por imagen , Esófago/diagnóstico por imagen , Patologia Forense , Contenido Digestivo/diagnóstico por imagen , Humanos , Pulmón/diagnóstico por imagen , Apófisis Mastoides/citología , Apófisis Mastoides/diagnóstico por imagen , Senos Paranasales/diagnóstico por imagen
5.
J Belg Soc Radiol ; 104(1): 7, 2020 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-32025623

RESUMEN

BACKGROUND: The correlation of diffusion-weighted MRI and tumor aggressiveness has been established for different tumor types, which leads to the question if it could also apply for neuroendocrine tumors (NET). PURPOSE: To investigate the possible correlation between apparent diffusion coefficient (ADC) value on magnetic resonance imaging (MRI) and histopathologic WHO-grades of NET. MATERIAL AND METHODS: Electronic patient records from patients presented at the multidisciplinary neuro-endocrine tumor board between November 2017 and April 2019 were retrospectively reviewed. Patients with both available MR imaging (primary tumor or metastasis) and known WHO tumor grade were included (n = 47). Average and minimum ADC values (avgADC; minADC) were measured by drawing a freehand ROI excluding only the outermost border of the lesion. The largest axial size (primary tumor) or most clearly delineated lesion (metastasis) was used. RESULTS: Forty seven patients met the inclusion criteria (mean age 59 ± 12 SD; 24F/23M). Twenty one patients (45%) were diagnosed with WHO G1 tumor, 17 seventeen with G2 (36%) and nine with G3 (19%) tumor. Twenty eight primary tumors and 19 metastases were measured. A significant difference was found between low-grade (G1+G2) and high-grade (G3) tumors (Mann-Whitney; avgADC: p < 0,001; minADC: p = 0,001). There was a moderate negative correlation between WHO-grade and avgADC/minADC (Spearman; avgADC: -0,606; 95% CI [-0,773; -0,384]; minADC: -0,581; 95% CI [-0.759; -0.353]). CONCLUSION: Our data show a significant difference in both average and minimum ADC values on MRI between low and high grade NET. A moderate negative correlation was found between histopathologic WHO grade and ADC value.

6.
J Thorac Dis ; 11(3): 987-1004, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31019789

RESUMEN

"Lung cancer associated with cystic airspaces" is an uncommon manifestation, in which lung cancer presents on imaging studies with a cystic area with associated consolidation and/or ground glass. With the widespread use of computed tomography (CT), both in clinical practice and for lung cancer screening, these tumors are being more frequently recognized. An association of this entity with smoking has been established with the majority of cases reported being in former and current smokers. The true pathogenesis of the cystic airspace is not yet fully understood. Different causes of this cystic airspace have been described, including a check-valve mechanism obstructing the small airways, lepidic growth of adenocarcinoma on emphysematous lung parenchyma, cyst formation of tumor and tumor growth along the wall of a pre-existing bulla. Adenocarcinoma is the commonest histological type, followed by squamous cell carcinoma. Two classification systems have been described, based on morphological features of the lesion, taking into account both the cystic airspace as well as the morphology of the surrounding consolidation or ground glass. The cystic component may mislead radiologists to a benign etiology and the many different faces on imaging can make early diagnosis challenging. Special attention should be made to focal or diffuse wall thickening and consolidation or ground glass abutting or interspersed with cystic airspaces. Despite their atypical morphology, staging and management currently are still similar to that of other lung cancer types. Although the rarity of this entity will hamper larger studies, numerous aspects regarding this particular lung cancer type still need to be unraveled. This manuscript reviews the CT-imaging findings and gives an overview of available data in the English literature on pathogenesis, histopathology and clinical findings. Differential diagnosis and pitfalls are discussed as well as future directions regarding staging and management.

7.
Cancer Imaging ; 19(1): 78, 2019 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-31783926

RESUMEN

PURPOSE: A newly developed image processing technique fuses conventional windows into a single 'All-In-One' (AIO) window. This study aims to evaluate variability of CT measurement of lesions in thoracic oncology patients on this novel AIO-window. METHODS: Six radiologists with different levels of expertise measured 368 lesions of various size, origin and sharpness. All lesions were measured twice on the AIO-window and twice on the conventional window settings. Intraclass correlation coefficients and Bland-Altman plots were used to assess intra- and interobserver variability. RESULTS: Overall intra-observer agreement for lesion diameters on the AIO-window and conventional window settings was 0.986 (95% Confidence interval (CI): 0.983-0.989) and 0.991 (95% CI 0.989-0.993) respectively. For interobserver agreement this was 0.982 (95% CI 0.979-0.985) (AIO) and 0.979 (95% CI 0.957-0.982) (conventional). For both the AIO and conventional windows, intra- and interobserver agreement were dependent on size, sharpness and reader experience. Measurement variability decreased with increasing lesion size. Regarding sharpness, inter- and intra-observer agreement ranged from 0.986-0.989 (AIO) and 0.985-0.992 (conventional) for well-defined lesions and from 0.978-0.983 (AIO) and 0.974-0.991 (conventional) for ill-defined lesions. CONCLUSIONS: Lesion diameters were consistently smaller on the AIO-window compared to conventional window settings. Overall intra- and interobserver variability rates were similar for the AIO-window and conventional window settings. We conclude that the AIO-window offers a reliable and reproducible alternative for measurement of thoracic lesions.


Asunto(s)
Abdomen/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada Multidetector/métodos , Neoplasias/diagnóstico por imagen , Tórax/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/normas , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector/normas , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA